• 제목/요약/키워드: DC급전

검색결과 109건 처리시간 0.032초

정전압 DC 급전시스템에서의 회생전력 (Regenerated Power in Fixed voltage DC Electric Power Supply System)

  • 정상기;이병송;정락교;박성혁;김국진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2001년도 추계학술대회 논문집
    • /
    • pp.343-349
    • /
    • 2001
  • In this study we examined the method to estimate numerically the amount of the regenerated power and the excess regenerated power produced in the DC electric power supply system for the urban light rail transit system. And their economic feasibilities are also studied. For this study DC electric power supply system is simulated and the numerical analysis of the regenerated power and the excess regenerated power are conducted. The study result on the sample system shows that the facility to consume the excess regenerated power or the inverting equipment to reuse the excess regenerated power in the electric substation is feasible economically.

  • PDF

직류급전시스템의 레일전위와 누설전류 관점에서의 설계 파라미터 연구 (Considering design parameters in terms of rail potential and leakage current in DC feeding system)

  • 한문섭;정호성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.236-241
    • /
    • 2007
  • DC feeding system is mainly floating but the rail potential and the leakage current are created because of long parallelism between rails and ground. Rail potential causes electric shock to human and leakage current causes electrolytic corrosion to nearby the buried metals. Therefore the design technologies to reduce, protect and monitor these effects are important recent DC feeding system. Normally during designing DC feeding system in terms of rail potential and leakage current, there are about 10 parameters. Four design parameters among those is analysed based on propagation theory that is utilized in order to simulate grounding system.

  • PDF

DC 비접지 급전계통 선택차단형 통합보호계전기 시뮬레이터 개발 및 알고리즘 테스트 (Development of a Simulator and Algorithm Test for Selective-breaking Integrated Protective Relay for Ungrounded DC Traction Power Supply System)

  • 안태풍;윤준석;정태영;김인웅;정호성
    • 전기학회논문지
    • /
    • 제61권6호
    • /
    • pp.899-904
    • /
    • 2012
  • In recent years, a lot of research was done for earth fault protection in ungrounded dc power supply system. As a result, selective-breaking integrated protective relaying system is developed in progress and is currently field-testing are planned. Algorithm on a PC using PSCAD done a lot of testing before performing field tests, but in this study developed algorithms and functions needed to determine whether they were operating normally. Therefore, simulated system is similar to the actual situation was required and made. selective-breaking algorithm verification and validation was performed with simulator.

직류급전시스템 회생용 인버터 개발 및 실계통 적용 방안 (A Scheme for Adoption of Regenerative Inverter in DC Transit System)

  • 김주락;한문섭;창상훈;김정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1044-1045
    • /
    • 2008
  • DC transit system has been adopted in the metropolitan area, Korea since 1974. EMU in this system always reiterates that acceleration and retardation. When EMU decelerates using electric breaking, regenerative power occurs. Regenerative power can be consumed in vicinity EMU on the same line or in resistor. If DC transit system has inverter for reusing regenerative power, Energy efficiency in DC transit system will be increased. This paper present the adoption of developed inverter in commercial railway line and the test result procedure of developed inverter is presented.

  • PDF

직류 급전시스템에서의 지락고장에 따른 전압상승 시뮬레이션 (Voltage rising simulation due to the ground fault in DC traction system)

  • 정호성;한문섭;박영;정상기;권삼영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.215-217
    • /
    • 2008
  • DC fraction system can damage human and other facilities due to the rising of rail potential. Therefore the earth fault detection relay protects system using rail potential induced in train operation and ground fault. However the conventional protection system cannot operate due to the fault resistance and might operate unwanted voltage rising due to the other substation ground fault. So this paper models DC traction system using PSCAD/EMTDC and simulates the rail potential rising. We can estimate the rail potential rising in DC traction system through the various simulation.

  • PDF

직류급전계통에서의 레일전위 상승 분석 및 억제 방안 연구 (An Analysis on Rise of Rail Potential And A Study on Control Method for It in DC Feeding System)

  • 민명환;정호성;박영;김형철;신명철
    • 전기학회논문지
    • /
    • 제60권3호
    • /
    • pp.680-685
    • /
    • 2011
  • Nowadays, in metropolitan railroad, DC feeding system is being generally applied. In order to reduce damages of electro-chemical corrosion caused by stray current and leakage current, in DC feeding system, rail is used as negative-polarity return conductor for traction load current. However, it has problem of rail potential increase and there are no adequate measures to prevent it in domestic. In this paper, we presented fundamental theory and related standards about rail potential increase. And then, we analyzed field testing data and simulated a variety of operations by using PSCAD/EMTDC as an analysis program of power system. In addition, voltage control device is suggested to prevent accidents caused by rail potential increase.

Fourier 변환 기반 시정수 추정 알고리즘을 이용한 직류 급전계통 보호 알고리즘 (A Protection Algorithm for DC Railway Systems Using Estimation of Time Constant Based on Fourier Transform)

  • 권영진;최동민;강상희;한문섭;이재경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.14-16
    • /
    • 2004
  • A DC railway system has low feeder voltage, The remote fault current can be smaller than the current of load starting. So it is important to discriminate between the small fault current and the load starting current. The load starting current increases step by step but the fault current increases all at once. As for the load starting current, the time constant of load current at each step is much smaller than that of the fault current. To detect faults in DC railway systems, an algorithm using the time constant calculated by the method of least squares was presented. But, It have a weakness about harmonic to calculate time constant. So in this paper, new protection algorithm for DC railway systems using estimation of time constant based on fourier transform was presented.

  • PDF

SR 컨버터 기반 25[kW]급 DC 계통연계 태양광 PCS 개발 (Development of Series Resonant Converter Based DC Utility Interactive PCS for 25[kW] PV System)

  • 윤여영;김홍성;정재기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 추계학술대회
    • /
    • pp.202-204
    • /
    • 2010
  • 본 논문은 DC 급전시스템에 적용 가능한 25[kW]급 계통연계 태양광 PCS 개발에 관한 것이다. 전력 회로는 넓은 범위의 입력 전압대에서 출력 전류가 조절 가능 하도록 Fixed Frequency Series Resonant Converter(SR Converter)로 구성하였으며, 스위칭 손실을 극소화 시킬 수 있는 ZVZCS 동작을 구현 하였으며, PWM 기법으로는 위상 천이 방식을 사용하였다. 제안한 DC 계통 연계형 태양광 PCS 시스템 동작에 대한 P-sim 시뮬레이션을 수행하였으며, 25[kW] Prototype을 제작하여 시뮬레이션 결과와 비교 실험을 수행하였다

  • PDF

직류 비접지계통에서 절연저항측정장치(IMD)를 이용한 사고검출 알고리즘 (Algorithm of Detecting Ground Fault by Using Insulation Monitoring Device(IMD) in Ungrounded DC System)

  • 김기영;이후동;태동현;노대석
    • 한국산학기술학회논문지
    • /
    • 제21권9호
    • /
    • pp.528-535
    • /
    • 2020
  • 최근 신재생에너지 및 분산전원의 급속한 보급과 직류부하의 증가로 인하여 직류급전에 대한 관심이 높아지고 있으며, 이에 대한 보호협조방식에 대한 연구가 활발히 이루어지고 있다. 그러나 직류급전방식을 사용하는 기존의 직류 부하망과 도시철도 등은 비접지방식인 IT 접지 시스템으로서 지락고장발생 시 고장전류의 경로가 없고, 정상상태 전류에 비하여 큰 차이가 발생하지 않기 때문에 지락고장검출이 어려운 실정이다. 따라서 본 논문에서는 절연저항측정장치(IMD : Insulation Monitoring Device)를 직류 비접지계통의 보호기기로 활용하기 위하여, IMD의 검출원리를 정식화한다. 이를 바탕으로 IMD의 신호주입방식에 의한 출력 값을 웨이블릿변환기법으로 분석하여, 사고검출을 신속하고, 정확하게 판단할 수 있는 검출알고리즘을 제안한다. 또한, 상용전력 계통해석프로그램인 PSCAD/EMTDC를 이용하여, 직류 비접지계통과 IMD를 모델링하고, MATLAB을 이용한 웨이블릿변환 수치해석모델링을 수행한다. 이를 바탕으로 직류 비접지계통의 지락사고를 해석한 결과, 본 논문에서 제안한 IMD의 사고검출 알고리즘의 유효성을 확인하였다.

하이브리드 급전을 위한 다양한 가정용 교류부하의 직류특성연구 (DC Characteristics Analysis of Various AC loads for Hybrid Distribution)

  • 이영진;한동화;최중묵;정병환;김동진;최규하
    • 전력전자학회논문지
    • /
    • 제15권3호
    • /
    • pp.207-217
    • /
    • 2010
  • 현재 디지털 제품의 사용의 증가로 제품 내부의 DC 전원의 사용이 증가하는 가운데 시스템의 구동전압을 공급하기 위해 기기내부에 장착된 AC/DC컨버터로 인한 입력전류의 역률저하 및 고조파 증가, 그리고 AC/DC 컨버터에서 발생하는 변환 손실 등의 문제가 발생한다. 하이브리드 배전시스템은 기존의 AC부하(전동기 부하 및 변압기 부하)와 DC 부하(컴퓨터, TV, LED조명)에 AC 와 DC 전원을 동시에 공급하며, 직류출력 전원(신재생에너지 및 배터리뱅크)과 상용전원에서 전력을 공급받아 사용자에게 DC 및 AC 전력을 공급해주는 시스템으로 상용전원의 효율을 향상시키고 신재생에너지의 사용 편의성을 올리며 가정에 AC와 DC를 동시에 공급하는데 주목적이 있다. 본 논문을 통해 DC 및 AC 동시 배전을 위해 기존 교류부하의 직류특성에 관한 연구를 하며, 하이브리드 배전의 적절한 DC 전압레벨을 선정한다.