• 제목/요약/키워드: D-zone test

검색결과 220건 처리시간 0.023초

The Fatigue Behavior and Delamination Properties in Fiber Reinforced Aramid Laminates -Case (I) : AFRP/Al Laminates-

  • Song, Sam-Hong;Kim, Cheol-Woong
    • Journal of Mechanical Science and Technology
    • /
    • 제17권3호
    • /
    • pp.343-349
    • /
    • 2003
  • The fuselage-wing intersection suffers from the cyclic bending moment of variable amplitude. Therefore, the influence of cyclic bending moment on the delamination and the fatigue crack propagation behavior in AFRP/Al laminate of fuselage-wing was investigated in this study. The cyclic bending moment fatigue test in AFRP/Al laminate was performed with five levels of bending moment. The shape and size of the delamination Lone formed along the fatigue crack between aluminum sheet and aramid fiber-adhesive layer were measured by an ultrasonic C-scan. The relationships between da/dN and ΔK, between the cyclic bending moment and the delamination zone size, and between the fiber bridging behavior and the delamination zone were studied. As results, fiber failures were not observed in the delamination zone in this study, the fiber bridging modification factor increases and the fatigue crack growth rate decrease and the shape of delamination zone is semi-elliptic with the contour decreasing non-linearly toward the crack tip.

선내 특별 전원 분배구역의 EMI에 관한 연구 (A study on the EMI in special power distribution zone on ship)

  • 박종성;최기도;김종우;조형래
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권6호
    • /
    • pp.730-736
    • /
    • 2014
  • 선박 운항에 필요한 전기 전자 장비에 대한 시험 규격은 IEC-60533 규격을 적용하고 있으나 선교구역, 일반전원 분배구역에 대한 규제치만 제시하고 있으며 특별전원 분배구역에 대한 별도의 규제치가 정립되어 있지 않다. 이로 인하여 특별전원 분배구역에 설치되는 각종 장비 대하여 과도한 사양을 요구하고 있는 실정이다. 본 논문에서는 실선에서 특별전원 분배구역에서의 전원 잡음을 측정하였고 일반전원 분배구역의 규격과 실선에서 측정한 값 들을 비교 분석 하였다. 실제 측정한 실선 한바다 호에서는 저주파 대역 160kHZ대역에서 6~8dB의 차이가 나타났고 고주파 1.97GHz대역에서 약 8.7dB의 차이를 보이고 있다. 또한 한나라 호에서 측정된 측정값은 1MHz, 11MHz, 25MHz에서 4~5dB 정도 ICE-60533의 기준과 차이를 나타내고 있다. 따라서 더 많은 실험을 한 후 자료를 비교 분석하여 특별전원 분배구역의 규격이 지정 되어야 할 것이다.

폴리에틸렌 배관 버트융착부 열용융거리 측정에 대한 연구 (A study for detection of melt flow zone about polyethylene butt fusion joints)

  • 길성희;김영구;조영도;이연재
    • 에너지공학
    • /
    • 제25권4호
    • /
    • pp.103-109
    • /
    • 2016
  • 폴리에틸렌(Polyethylene) 배관은 가요성이 좋고 부식이 되지 않는 등의 장점으로 가스배관 뿐만 아니라 원자력 발전소의 배수관, 석유화학 및 정유사 공정배관 등으로 그 사용범위가 점차 확대되고 있다. 그러나 폴리에틸렌 배관의 연결부를 직접적으로 검사할 수 있는 검사방법이 개발되지 않아서 사용범위를 확대하는데 제한을 받고 있다. 폴리에틸렌 배관의 연결방법은 전기융착 방법과 버트융착 방법으로 구분할 수 있는데 이 중에서 가장 많이 사용하는 방법은 버트융착이다. 버트융착은 배관과 배관을 열판에 맞닿게 하고 일정한 온도 및 압력을 가한 후 열판을 제거하고 용융된 배관의 말단부를 서로 연결하는 방법으로서 별도의 연결구가 필요하지 않아 가장 많이 사용하고 있는 연결방법이다. 버트융착 시에 열판으로부터 열이 용융된 후 압력을 가하면 용융부는 비드를 형성하는 부분과 연결부를 형성하는 부분으로 분리되고 냉각과정을 거쳐 버트융착부가 된다. 본 연구는 연결부를 형성하는 부분에서 열판으로부터 열이 전파되어 용융된 거리를 측정하고 이 결과를 연결부에 대한 건전성 평가 방법 중의 하나로 제시하고자 한다. 외경 225mm, 두께 20.5mm의 중밀도 폴리에틸렌 가스용 1호관의 초음파 속도를 측정한 결과 2,200m/s 였다. 열용융 거리를 측정하기 위하여 열판으로부터 열이 전파되어 폴리에틸렌을 가열하는 시간을 0%~130%까지 변화시켜 시험편을 제작하였다. 또한 정상적인 가열시간(100%의 가열)을 제공하고 스크레핑 처리를 하지 않은 시험편과 토양을 삽입한 시험편 그리고 자갈을 삽입한 시험편과 비닐류를 삽입한 시험편을 제작하였다. 총 20개의 시험편에 대한 열용융 거리를 측정하기 위하여 3.5MHz 및 5.0MHz 센서를 이용하였으며 1개의 시험편에 대하여 총 3곳에서 초음파 탐상을 실시하였다. 열용융 신호를 명확하게 구분하기 위하여 모든 탐상 결과에 대하여 동일한 post image processing을 수행하였고 이미지 레벨, contrast, sharpen 및 threshold를 적용하였으며 결과 탐상은 가장 직관적으로 파악할 수 있는 gray scale로 표현하였다. 탐상 결과 가열시간이 짧은 시험편일수록 융착이 이루어지지 않아 멀티플 에코가 반사되는 영역이 증가하였으며 이 부분을 최대한 배제할 수 있는 위치에서 데이터를 획득하였다. 정상적인 가열시간의 80%인 168초의 시간을 가한 시험편부터 열용융 거리에 대한 반사신호가 뚜렷이 구분되었으며 이 시험편부터 거리 측정을 실시하였다. 가열시간이 정상가열시간의 7%인 15초의 가열시간을 가한 시험편부터 더 낮은 가열시간을 가한 시험편의 경우 융착이 이루어지지 않아서 3곳 모두 데이터 영상을 획득할 수 없었다. 위 실험 결과로 위상배열초음파를 통해 폴리에틸렌 배관 버트융착부에서 열이 용융되어 전파된 거리 측정이 가능함을 확인하였으며 또한 열이 용융되어 전파된 거리 측정을 통해 정상적인 융착과 불완전 융착을 구분할 수 있음을 확인할 수 있었다.

조선강재의 최적 용접조건에 관한 연구 (Study on Optimal Welding Condition for Shipbuilding Steel Materials)

  • 김옥환
    • 한국기계가공학회지
    • /
    • 제10권6호
    • /
    • pp.128-133
    • /
    • 2011
  • In this study, the steel material for shipbuilding(LR-A class) was used, and FCAW was taken advantage of 3G attitude and they are welded by different welding ways. As a result of analyzing wave with welding monitoring system, the stable values are obtained which are the first floor(electronic current 164~182 A, voltage 24 V), the second floor(electronic current 174~190 A, voltage 22~25 V), the third floor(electronic current 158~188 A, voltage 22~25 V), and fourth floor(electronic current 172~184 A, voltage 22~25 V), at this time, the stable wave standard deviation and changing coefficient could be obtained. When the welding testing through nondestructive inspection was analyzed know defect of welding, there was no defect of welding in A, D, E, but some porosities in B, and slag conclusion near the surface in C, because the length of arc was not accurate, and the electronic current and voltage was not stable. After observing the change of heat affect zone through micro testing, each organization of floor formed as Grain Refinement, so welding part was fine, the distance of heat affect zone is getting wider up to change the values of the electronic current and voltage. As a result of degree of hardness testing, the hardness orders were the heat affect zone(HAZ), Welding Zone(WZ), and Base Metal(BM). When the distribution of degree of hardness is observed. B is the highest degree of hardness The reason why heat effect zone is higher than welding zone and base metal, welding zone is boiled over melting point($1539^{\circ}C$) and it starts to melt after the result of analysis through metal microscope, so we can know that delicate tissue is created at the welding zone. Therefore, in order to get the optimal conditions of the welding, the proper current of the welding and voltage is needed. Furthermore the precise work of welding is required.

내진철골모멘트접합부 패널존의 전단좌굴 방지를 위한 패널존 상대강도 (Relative Panel Zone Strength in Seismic Steel Moment Connections for Prevention of Panel Zone Shear Buckling)

  • 김소연;이철호
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.845-850
    • /
    • 2007
  • The empirical AISC panel zone thickness provision$(t_z\geq(d_z+w_z)$/90) to prevent the cyclic shear buckling of the panel zone was proposed based on the test data of Krawinkler et al. (1971) and Bertero et al. (1973) However, no published records of the equation development or any other background information appear to be available. The calibrated finite element analysis results of this study indicated that the AISC provision was not reasonable. In this study, through including the effects of the column axial force and the aspect ratio of the panel zone, a new equation for the relative strength between the beam and the panel zone was proposed such that the proposed equation can prevent the panel zone shear buckling and reduce the potential fracture associated with the kinking of the column flanges.

  • PDF

포도구균의 Erythromycin 유도성 Clindamycin 내성검출을 위한 간편한 디스크 확산법의 유용성 (An Easy Method of Disk Diffusion Antibiotic Susceptibility Test for Detection of Erythromycin-induced Resistance to Clindamycin in Staphylococci)

  • 주세익;이현;임규상;김의종
    • 대한임상검사과학회지
    • /
    • 제38권1호
    • /
    • pp.38-44
    • /
    • 2006
  • A simple and easy modification of AST by disk diffusion was tested for the detection of induced clindamycin resistant Staphylococci and their antimicrobial susceptibility at the same time. The incidence of inducible clindamycin resistant staphylococci in blood culture and their MIC characterization at Seoul National University Hospital was analyzed by an AST contained disk approximation test (D-zone test) and Etest, respectively. Of the total 309 staphylococcal isolates, 139 (45%) isolates presented constitutive resistance to ERY and CLI (ERY-R, CLI-R phenotype), and 59 were ERY-I/R and CLI-S phenotypes. Of the 59 isolates, 19 (32%) isolates were inducible resistant to CLI. The incidence was higher in S. aureus (66.7%) than coagulase-negative staphylococci (CNS, 26.0%). Especially, methicillin-resistant staphylococci (MRSA, 100%; MRCNS, 45.5%) presented higher inducibility than methicillin susceptible (MSSA, 50%; MSCNS, 20%). For most of the inducible clindamycin resistant staphylococci (15 of 19 isolates), their ERY MIC were high (>$128_{\mu}g/mL$) and were methicillin resistant. The remaining 4 isolates were methicillin susceptible and their ERY MIC were of intermediate concentrations ($1-4_{\mu}g/mL$). We concluded that suscetibility testing of staphylococci, especially methicillin resistant, should include the D-zone test.

  • PDF

가스터빈 연소기 기본형상 결정을 위한 성능실험 (An experimental study for preliminary design of gas turbine combustor)

  • 안국영;김한석;조은성;배진호
    • 대한기계학회논문집B
    • /
    • 제22권6호
    • /
    • pp.840-848
    • /
    • 1998
  • The preliminary design and performance test were carried out for determining dimensions of gas turbine combustor. The combustor design program was developed and applied to design our combustor, and the specific dimensions for swirler, dome and liner holes were determined by the semiempirical manner. Based on the first performance test data, the swirl angle governing the combustion characteristics of primary combustor zone was determined as 40 deg.. Using the second performance test data, the swirler dimensions were readjusted by 24 mm i.d., 34 mm o.d., and swirl angle of 45 deg.. The geometry of liner holes were determined by considering the flame stability and recirculation zone size. It was found that flame can be more easily stabilized by adjusting the swirler dimensions rather than liner holes. The geometry of swirler and liner holes were readjusted by using the final performance test data with dilution holes. Also, the combustor performance and emission characteristics were evaluated by analysis of exhaust gases.

CFRD Bedding Zone의 축조재료에 대한 투수성 평가 (Evaluation of Permeability on Construction Material in CFRD Bedding Zone)

  • 한상현;여규권
    • 지질공학
    • /
    • 제19권4호
    • /
    • pp.493-499
    • /
    • 2009
  • 우리나라는 암석자원이 풍부하기 때문에 콘크리트표면 차수벽형 석괴댐(CFRD)의 시공이 증가하고 있는 실정이다. 콘크리트표면 차수벽형 석괴댐에서의 표층부 기초지반인 Bedding Zone 구간은 콘크리트 차수벽을 균등하게 지지할 수 있는 지지력과 콘크리트 차수벽의 누수시 세립토의 유실을 억제할 수 있는 차수성을 유지하여야 한다. 따라서 Bedding Zone 구간의 차수성 확보 여부가 댐의 안정성을 좌우하는 주요 요인이 될 수 있다. 본 연구에서는 기존의 시방서에 제시된 Zone-1 구간의 설계입도분포를 만족하는 시험재료를 선정한 후, 차수성을 평가하기 위하여 실내시험을 실시하였다. 시험 분석 결과 투수계수, 건조단위중량 및 흙의 입도분포에 따른 차수효과의 상관관계를 제시하였다. 특히, 투수계수와 건조단위중량의 상관관계, No. 4체 중량통과백분율과 투수계수 관계가 제시되었고, 또한 시간경과에 따른 투수계수의 변화도 제시되었다.

순수 티타늄 판재의 피로균열 전파거동에 관한 연구 (A Study on Fatigue Crack Propagation Behavior with Pure-Ti Plate)

  • 오세욱;김태형;김득진;임만배
    • 한국해양공학회지
    • /
    • 제9권1호
    • /
    • pp.92-100
    • /
    • 1995
  • The effect of different anisotropy and stress ratio on fatigue crack propagation behavior was investigated under various stress ratio(R=-0.4, -0.2, 0.2, 0.2, 0.4) using pure titanium sheet used in aerospace, chemical and food industry. The rack closure behavior under constant load amplitude fatigue crack propagation test was examined. Fatigue crack propagation rate da/dN was estimated in terms of effective stress intensity factor range, $\Delta$K$_{eff}$, regardless of various stress ratio but was influenced by anisotropy. Also, it was found that the effect of anisotropy was considerably decreased but still not negligible when he da/dN was evaluated by a conventional parameter, $\Delta$$K_{eff}$/E and when the modified da/dN.$\sqrt{\varepsilon}_f$ was evaluated by $\Delta$$K_{eff}$/E. On the other hand, da/dN could be evaluated uniquely by effective new parameter, $\Delta$K$_{eff}$/$sigma_{ys}$, regardless of anisotropy, as int he following equation da/dN=C''[\frac{{\Delta}K_{eff}}{{\sigma}_{ys}}]^{n''}. And effective stress intensity factor range ratio, U was estimated by the following equation with respect to the ratio of reversed plastic zone size, $\Delta r_{p}$ to monotonic plastic zone size, $r_p$ regardless of stress ratio and anisotropy. U=-4.45$(\Delta r_{p}/r_{p})^{2}$+4.1$(\Delta r_{p}/r_{p})$+0.245_{p})$+0.245

  • PDF

Cohesive Zone Model을 이용한 동력조향 유압실린더의 스틸-알루미늄 접착부 설계 (Joint Design of Steel-Aluminum Power Steering Cylinder by using FE Analysis with Cohesive Zone Model)

  • 이찬주;이상곤;고대철;;이종만;김병민
    • 소성∙가공
    • /
    • 제18권5호
    • /
    • pp.385-391
    • /
    • 2009
  • An adhesively bonded power steering cylinder with a steel tube and an aluminum bracket was developed to reduce the weight of steering systems. To achieve the joint strength between the steel tube and of the aluminum bracket, the shape aluminum bracket re-designed by using the FE-analysis. Fracture behavior of the adhesive layer was considered by a cohesive zone model(CZM), which is based on the two-parameter fracture phenomenon with critical stress and fracture toughness. From the result of FE-analysis with CZM, re-designed power steering cylinder satisfied the desired joint strength for axial and torsion modes. And its joint strength was verified by the fracture test in each mode.