• Title/Summary/Keyword: D-optimal Design

Search Result 1,314, Processing Time 0.028 seconds

The development of a new type of functional fresh apple juice using prebiotic fibers, ginger extract, and cardamom essential oil: Antioxidant capacity and chemical analysis

  • Hamed Hassanzadeh;Mohammadyar Hosseini;Yaseen Galali;Babak Ghanbarzadeh
    • Food Science and Preservation
    • /
    • v.30 no.5
    • /
    • pp.743-757
    • /
    • 2023
  • The formulation of a novel functional fresh apple juice enriched with dietary prebiotic fiber (inulin or polydextrose), ginger extract (GE), and cardamom essential oil (CEO) was carried out based on a combined D-optimal design. In the first stage, sensory evaluation was performed to screen and select the optimum sample for further experiments. The sensory evaluation showed that the sample containing inulin 0.25 g/100 g GE and 0.03 g/100 g CEO had the highest organoleptic score. In the second stage, various chemical experiments, including pH, acidity, formalin index, total phenol, flavonoids, antioxidant capacity, and vitamin C content, were evaluated on the selected enriched apple juices. The addition of GE and CEO caused changes in nutritional characteristics, including antioxidant capacity, total phenol, flavonoids, vitamin C, and IC50, from 35 g/100 g, 350 mg GAE/g, 17 mg/L, 370 mg/kg, and 1,800 mg/kg to 45 g/100 g, 460 mg GAE/g, 21 mg/L, 420 mg/kg, and 1,200 mg/kg respectively. The steady shear flow and dynamic oscillatory shear rheological tests were also performed on the screened samples, and results showed that the addition of dietary fiber in apple juices increased the apparent viscosity, storage modulus, loss modulus, and complex viscosity. In general, adding plant extracts and processed essential oil to apple juice increased the nutritional-nutraceutical value and sensory attributes of apple juice.

Development of Thermal Performance Prediction for Large Planar Military Antenna with Multi-Cooling Channels (다중 냉각유로가 적용된 수랭식 군사용 대면적 안테나의 열성능 예측 기술)

  • YeRyun Lee;SungWook Jang;PilGyeong Choi;NohJin Kwak;JunJung Park
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.27 no.1
    • /
    • pp.43-50
    • /
    • 2024
  • Large planar military antenna boasts a range of electrical components, including TRA(Transmit-Receive Assembly), signal processors, etc. which engage in computations and calculations. These processes generate a significant amount of heat, leading to unforeseen consequences for the equipment. To mitigate these adverse effects, it's imperative to implement a cooling system that can effectively reduce heat-related issues. Given the antenna's intricate nature and the multitude of components it houses, a two-step estimation process is necessary. The first step involves a comprehensive model calculation to determine the total flow characteristics, while the second step entails a thermal analysis of individual TRA set. In this study, we depicted an antenna set using simplified 3D models of its components, considering their material and thermal properties. The sequential analysis process facilitated the calculation of branched flow rates, providing insights into the individual TRA. This approach also allowed us to design a cooling system for the TRA set, assessing its thermal stability in high-temperature environments. To ensure the optimal performance of TRA, breaking down the analysis into stages based on the cooling system's structure can assist operators in predicting numerical results more effectively.

A Study on the Determination of Optimal Location and Size for Underground Sluiceway Design (지하방수로 설계를 위한 적정 위치선정 및 규모 결정에 관한 연구)

  • Lee, Jong-Tae;Lim, Taek-Sun;Hur, Sung-Chul;Park, Sang-Sik
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.5
    • /
    • pp.137-145
    • /
    • 2008
  • In this study, to reduce the flood damage caused by flood discharge exceeding project flood, the primary technology was applied to determining the optimal location and size for underground sluiceway. The Jungrang Stream was selected for this study because the stream was overflowed and the embankment section of the stream was destroyed owing to localized torrential rainfall in 1998 and 2001. Considering 200-year frequency storm, the inlets of the underground discharge channel were located at Seoul City limits, the confluence of Danghyun Stream, Wolgye 1-gyo, and the confluence of Mukdong Stream. The outlets were located at the estuary of Jungrang Stream and rightbank of Banpo Bridge in Han River. The transverse discharge according to the variation of overflow depth at the inlet of underground discharge channel was estimated and the effect of inundation reduction was analyzed. To examine the appropriate scale of the underground discharge channel, the 8 operation methods for the management of outlet discharge were compared considering four rules (only storage, the constant discharge rate, the constant discharge volume, and the mixture of the constant discharge rate and discharge volume). As a result, the effect of inundation reduction was most significantly improved when the inlet was located at the confluence of Danghyun Stream. The appropriate size of underground sluiceway for 200-year frequency storm was studied, and as a result, the appropriate diameters of the underground discharge channel were 12 m in case of only storage(Rule D), 9m in 50% of discharge(Rule E), 8 m in constant discharge volume(Rule F), and 7 m in mixture method(Rule G). This investigation process can be applied to design the underground discharge channel when the inundation damage is significant in coastal area due to embankment overflow. The underground discharge channel in Jungrang Stream can also be used as an underground road to link Seoul City to Uijeongbu City during dry season.

Estimation of the Optimal Ratio of Standardized Ileal Digestible Threonine to Lysine for Finishing Barrows Fed Low Crude Protein Diets

  • Xie, Chunyuan;Zhang, Shihai;Zhang, Guijie;Zhang, Fengrui;Chu, Licui;Qiao, Shiyan
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.26 no.8
    • /
    • pp.1172-1180
    • /
    • 2013
  • Two experiments were conducted to determine the standardized ileal digestible (SID) lysine (Lys) requirement and the ideal SID threonine (Thr) to Lys ratio for finishing barrows. In Exp. 1, 120 barrows with an average body weight of $72.8{\pm}3.6$ kg were allotted to one of six dietary treatments in a randomized complete block design conducted for 35 d. Each diet was fed to five pens of pigs containing four barrows. A normal crude protein (CP) diet providing 15.3% CP and 0.71% SID Lys and five low CP diets providing 12% CP with SID Lys concentrations of 0.51, 0.61, 0.71, 0.81 and 0.91% were formulated. Increasing the SID Lys content of the diet resulted in an increase in weight gain (linear effect p = 0.04 and quadratic effect p = 0.08) and an improvement in feed conversion ratio (FCR) (linear effect p = 0.02 and quadratic effect p = 0.02). For weight gain and FCR, the estimated SID Lys requirement of finishing barrows were 0.71 and 0.71% (linear broken-line analysis), 0.79 and 0.78% (quadratic analysis), respectively. Exp. 2 was a 26 d dose-response study using SID Thr to Lys ratios of 0.56, 0.61, 0.67, 0.72 and 0.77. A total of 138 barrows weighing $72.5{\pm}4.4$ kg were randomly allotted to receive one of the five diets. All diets were formulated to contain 0.61% SID Lys (10.5% CP), which is slightly lower than the pig's requirement. Weight gain was quadratically (p = 0.03) affected by SID Thr to Lys ratio while FCR was linearly improved (p = 0.02). The SID Thr to Lys ratios for maximal weight gain and minimal FCR and serum urea nitrogen (SUN) were 0.67, 0.71 and 0.64 using a linear broken-line model and 0.68, 0.78 and 0.70 using a quadratic model, respectively. Based on the estimates obtained from the broken-line and quadratic analysis, we concluded that the dietary SID Lys requirement for both maximum weight gain and minimum FCR was 0.75%, and an optimum SID Thr to Lys ratio was 0.68 to maximize weight gain, 0.75 to optimize FCR and 0.67 to minimize SUN for finishing barrows.

Effect of Roughage Sources on Cellulolytic Bacteria and Rumen Ecology of Beef Cattle

  • Wora-anu, S.;Wanapat, Metha;Wachirapakorn, C.;Nontaso, N.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.11
    • /
    • pp.1705-1712
    • /
    • 2007
  • The effect of different tropical feed sources on rumen ecology, cellulolytic bacteria, feed intake and digestibility of beef cattle was investigated. Four fistulated, castrated male crossbred cattle were randomly allocated to a $4{\times}4$ Latin square design. The treatments were: T1) urea-treated (5%) rice straw (UTS); T2) cassava hay (CH); T3) fresh cassava foliage (FCF); T4) UTS:FCF (1:1 dry matter basis). Animals were fed concentrates at 0.3% of body weight on a DM basis and their respective diets on an ad libitum basis. The experimental period was 21 days. The results revealed that the use of UTS, CH, FCF and UTS:FCF as roughage sources could provide effective fiber and maintain an optimal range of ruminal pH and $NH_3-N$. Total viable and cellulolytic bacterial populations were enhanced (p<0.05) with UTS as the roughage source. Animals fed FCF had a higher rumen propionate production (p<0.05) with a lower cellulolytic bacteria count. Moreover, three predominant cellulolytic bacteria species, namely Fibrobacter succinogenes, Ruminococcus albus and Ruminococcus flavefaciens, were found in all treatment groups. Roughage intake and total DM intake were highest with UTS (2.2 and 2.5% BW, respectively) as the roughage source (p<0.05). Nutrient intake in terms of organic matter intake (OMI) was similar in UTS, CH and UTS:FCF treatments (8.0, 6.8 and 8.7 kg/d, respectively), while crude protein intake (CPI) was enhanced in CH, FCF and UTS:FCF as compared to the UTS treatment (p<0.05). Digestion coefficients of DM and organic matter (OM) were similar among treatments, while the CP digestion coefficients were similar in CH, FCF and UTS:FCF treatments, but were higher (p<0.05) in CH than in UTS. CP and ADF digestible intakes (kg/d) were highest (p<0.05) on the CH and UTS treatments, respectively. It was also observed that feeding FCF as a full-feed resulted in ataxia as well as frequent urination; therefore, FCF should only be fed fresh as part of the feed or be fed wilted. Hence, combined use of FCF and UTS as well as CH and FCF were recommended.

Development of a Core management Algorithm for Optimal Design of AMBIDEXTER Transient Cores (AMBIDEXTER 천이노심 설계최적화를 위한 노심관리 알고리즘 개발)

  • Yu, Geuk-Jong;Sin, Dong-Hun;So, Sun-Gyu;Lee, Yeong-Jun;Kim, Jin-Seong;O, Se-Gi
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2004.10a
    • /
    • pp.99-100
    • /
    • 2004
  • AMBIDEXTER-NEC의 천이노심은 $^{Nat}Th$$^{Nat}U$의 주입만으로 전 출력의 Break-even 노심에 도달하기위한 중간 단계이다. 선행연구에서 수행한 전 출력노심인 평형노심의 핵종수밀도에 도달하기 위해서 평형노심에서의 기저물질, 잠재핵분열성물질, 핵분열물질의 수밀도를 각 SEU-기반, Pu-기반, ADS-기반에서 그대로 유지하여 초기노심을 구성하였다. 또 각 시나리오에 대해 최대첨두출력과 원자로의 안전성을 고려해 Excess Reactivity를 5mk 내에서 초기노심을 결정하였다. 각 노심은 주 핵분열성물질 $^{235}U$, $^{239}Pu$$^{233}U$의 핵반응단면적 특성에 따라 평균 전환율이 각각 0.95, 0.83 및 1 .21 로서 핵연료물질의 적절한 선택만으로도 전환로, 연소로 및 증식로로 설계할 수 있음을 보여준다. 이러한 $Th/^{233}U$, U/Pu 핵연료주기를 사용하는 AMBIDEXTER-NEC 용융염핵연료 원자로의 초기노심에서 시작한 천이노심은 평형노심에장전할 충분한 $^{233}U$ 양을 확보해야 하므로 천이노심의 목표는 평형노심 $^{233}U$의 요구량에 최소한의 기간에 가장 적은 외부주입을 통해 도달하는 것이다. 천이노심에서 임계가 유지되는 AMBIDEXTER-NEC 원자로시스템의 3군 핵종변환 코드인 HELIOS-SQUID-AMBIBURN 체제를 개발하였고 그림 1.에 나타내었다. 이 알고리즘은 각 초기노심 중원소의 미시단면적, 중원소를 제외한 원소들의 거시단면적, 임계도를 만족하는 중성자속 및 외부주입율을 계산하여 SQUID 및 AMBIBURN 입력자료를 제공한다. 또한 일정시간 중원소의 핵종농도, 외부주입율과 중성자속이 일정하다는 가정 하 에 반복수행 하고 SEU-기반과 Pu-기반의 경우에는 각각 핵변환을 거쳐 재순환되는 $^{233}U$$^{239}Pu$의 양을 바로 주입하는 최대재순환 경우와 평형노심 요구 장전량에 이를 때까지 시설 내 저장하는 최소재순환 경우로 상황을 모사하였다. 그림 2 는 각 시나리오별 초기노심에서부터 200FPD까지 단위 용융염 체적당 $^{233}U$의 수밀도 시간변화를 나타낸 것이다. 그림을 보면 50일 이후부터는 수밀도의 변화가 일정한 기울기를 보이고 있고 재처리공정에서 $^{233}Pa$를 분리하는 최소재순환의 경우에는 최대재순환보다 2-3%정도에 지나지않아 그림에서 나타내지않았다. SEU-기반 및 Pu-기반에서 $^{233}U$의 증가율이 각각 2.54E+13, 2.81E+13 #/cc/d 로 Pu 기반이 조금 더 큰 증가율을 나타내고 있지만 평형노심 농도 1.04E+20 #/cc/d 에 도달하기 위해서는 두 경우 모두 매우 긴 시간이 걸릴 것을 예상할 수 있다. 요컨대 250MWth AMBIDEXTER-NEC가 평형노심을 이루기 위해 필요로 하는 $^{233}U$을 생산하는데 제안한 SEU-기반, Pu-기반 시나리오는 천이노심주기기간이 전형적인 원자로 수명 3-40년 보다 매우 큰 것으로 나타났다. 따라서 장전될 $^{233}U$의 확보를 위한 최적옵션은 초기노심부터 ADS와 같은 외부생산시설로부터 전량을 공급 받아 운전하는 것이라 판단된다.

  • PDF

Performance estimation of conical picks with slim design by the linear cutting test (II): depending on skew angle variation (선형절삭시험에 의한 슬림 코니컬커터의 절삭성능 평가(II): Skew Angle 변화에 의한 결과)

  • Choi, Soon-Wook;Chang, Soo-Ho;Lee, Gyu-Phil;Park, Young-Taek
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.6
    • /
    • pp.585-597
    • /
    • 2014
  • In this study, the cutter acting forces were measured by 3-directional load cell at two different skew angles and various S/d ratios during a series of linear cutting tests using a slim conical pick. The analysis for cutting performance were carried out after calculating average values of the measured results. The increase of penetration depth results in the decrease of specific energy. And the variations of the cutter acting forces depending on penetration depth in the case of 6 degree skew angle were smaller than in the case of 0 degree skew angle. From this results, 6 degree skew angle is more effective than 0 degree skew angle in designing optimal specifications of cutting head. In addition, $F_c/F_n$ under the setting of 6 degree skew angle was smaller than under the setting of 0 degree skew angle. However, it should be considered that the increase of cutter acting force in the cutting direction accompanied the increase of driving force in the case of the setting for 6 degree skew angle.

Design of a Wide-Frequency-Range, Low-Power Transceiver with Automatic Impedance-Matching Calibration for TV-White-Space Application

  • Lee, DongSoo;Lee, Juri;Park, Hyung-Gu;Choi, JinWook;Park, SangHyeon;Kim, InSeong;Pu, YoungGun;Kim, JaeYoung;Hwang, Keum Cheol;Yang, Youngoo;Seo, Munkyo;Lee, Kang-Yoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.1
    • /
    • pp.126-142
    • /
    • 2016
  • This paper presents a wide-frequency-range, low-power transceiver with an automatic impedance-matching calibration for TV-white-space (TVWS) application. The wide-range automatic impedance matching calibration (AIMC) is proposed for the Drive Amplifier (DA) and LNA. The optimal $S_{22}$ and $S_{11}$ matching capacitances are selected in the DA and LNA, respectively. Also, the Single Pole Double Throw (SPDT) switch is integrated to share the antenna and matching network between the transmitter and receiver, thereby minimizing the systemic cost. An N-path filter is proposed to reject the large interferers in the TVWS frequency band. The current-driven mixer with a 25% duty LO generator is designed to achieve the high-gain and low-noise figures; also, the frequency synthesizer is designed to generate the wide-range LO signals, and it is used to implement the FSK modulation with a programmable loop bandwidth for multi-rate communication. The TVWS transceiver is implemented in $0.13{\mu}m$, 1-poly, 6-metal CMOS technology. The die area of the transceiver is $4mm{\times}3mm$. The power consumption levels of the transmitter and receiver are 64.35 mW and 39.8 mW, respectively, when the output-power level of the transmitter is +10 dBm at a supply voltage of 3.3 V. The phase noise of the PLL output at Band 2 is -128.3 dBc/Hz with a 1 MHz offset.

An Exploration of Adult Women Health-Behaviors (성인여성의 건강행위에 관한 연구)

  • Kim Myoung Hee;Chon Mi Young
    • Journal of Korean Public Health Nursing
    • /
    • v.16 no.2
    • /
    • pp.239-253
    • /
    • 2002
  • Health care for women regularly focuses on the reproductive system to the exclusion of other health needs. The lack of research focusing on women's common health issues is a major problem to the enhanced optimal level of women's health. Health care providers have to recognize biological and social differences between men and women. This study was conducted to identify the baseline data and their correlation of health perception, health behavior, and health status of adult women for developing nursing intervention. The study was a descriptive correlational design. A convenient sampling method was used for collecting data from 103 adult women, over 18 years of age, during the period from Sep 1 to Nov 30, 2001. The study's subjects were interviewed using a structured questionnaire. The instruments for this study were the health perception scale modified by Lee(1985) based on the tool developed by Ware(1977) and Jenkins (1966), and the health behavior scale by Ko, Kumja(1987). Health status was measured by the short form Cornell Medical Index(CMI) modified by Nam, Hochang(1965). The data were analyzed SPSS PC+, by frequency, mean, t-test, ANOVA, and Pearson correlation coefficients. Also, the Duncan test was utilized for a post hoc test of ANOVA. The results of this study are as follows: 1. The mean score for health perception was 3.02(S.D=0.39) on a 5 point scale. 2. The mean score for health behavior was 3.08(S.D=0.43) on a 5 point scale. 3. The mean score for health status was 18.54 on 58 items. The mean score for physical symptoms of a subscale of health status was 11.30 on 36 items and the mean score for psychological symptoms was 7.37 on 22 items. 4. The relationship of sociodemographic variables to health perception. health behavior, and health status of women.: 1) There were significant differences in the scores of health perception by disease experience(t=-3.37, p=0.00). 2) There were significant differences in the scores of health behavior by age(F=10.52, p=0.00), height(F=4.73, p=0.01), marital status(t=-5.56, p=0.00), educational background(t=2.90, p=0.00), and drinking or non-drinking(t=2.17, p=0.03). 3) There were significant differences in the scores of health status by educational background(t=2.28, p=0.02) and disease experience(t=2.61, p=0.01). 5. Health perception showed significant positive correlation with health behavior(r=0.39, p=0.00). Health perception showed significant negative correlation with health status(r=-0.44, p=0.00), that is, the more women perceived health, the less she complained about unhealthy symptoms. Health behavior had no significant correlation with health status but showed a positive correlation with psychological symptoms of a subscale of health status(r=-0.19, p=0.05). Many of the leading causes of disease are preventable through changes in health perception and behavior. The need to increase individual awareness of relationships among health perception, health behavior, and health status and to enhance knowledge regarding the long-term effects of positive health behaviors, is an important nursing strategy for women's health promotion.

  • PDF

Experimental Study on the Control Characteristics of Each Channel in a Semiconductor Chiller (반도체 공정용 칠러의 채널별 제어특성에 관한 실험적 연구)

  • Kim, Hyeon-Joong;Kwon, Oh-Kyung;Cha, Dong-An;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1285-1292
    • /
    • 2011
  • The characteristics of a semiconductor chiller system with EEV have been experimentally studied. Three experiments on temperature changes (increase and decrease), load variation, and control precision were conducted to investigate the operating characteristics of the semiconductor chiller. The power consumption was 8.9 kW during increase in temperature. The required time was 37.5 min for CH1 and 39.5 min for CH2. Moreover, the time required for falling temperature was 26.5 min. The control precision for partial load operation was relatively low compared to that of a full load operation. In addition, the CH2 equipped with a step motor showed better control precision. The power consumed by the chiller for process cooling water was 1.8 kW, which was one-half of that consumed during the refrigeration cycle. The objective of this study is to provide an optimal control guideline for the semiconductor chiller design.