• Title/Summary/Keyword: D-optimal Design

Search Result 1,316, Processing Time 0.033 seconds

Development of a High-Resolution Electrocardiography for the Detection of Late Potentials (Late Potential의 검출을 위한 고해상도 심전계의 개발)

  • 우응제;박승훈
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.449-458
    • /
    • 1996
  • Most of the conventional electrocardiowaphs foil to detect signals other than P-QRS-T due to the limited SNR and bandwidth. High-resolution electrocardiography(HRECG) provides better SNR and wider bandwidth for the detection of micro-potentials with higher frequency components such as vontricular late potentials(LP). We have developed a HRECG using uncorrected XYZ lead for the detection of LPs. The overall gain of the amplifier is 4000 and the bandwidth is 0.5-300Hz without using 60Hz notch filter. Three 16-bit A/D converters sample X, Y, and Z signals simultaneously with a sampling frequency of 2000Hz. Sampled data are transmitted to a PC via a DMA-controlled, optically-coupled serial communication channel. In order to further reduce the noise, we implemented a signal averaging algorithm that averaged many instances of aligned beats. The beat alignment was carried out through the use of a template matching technique that finds a location maximizing cross-correlation with a given beat tem- plate. Beat alignment error was reduced to $\pm$0.25ms. FIR high-pass filter with cut-off frequency of 40Hz was applied to remove the low frequency components of the averaged X, Y, and Z signals. QRS onset and end point were determined from the vector magnitude of the sigrlaIL and some parameters needed to detect the existence of LP were estimated. The entire system was designed for the easy application of the future research topics including the optimal lead system, filter design, new parameter extraction, etc. In the developed HRECG, without signal averaging, the noise level was less than 5$\mu$V$_rms RTI$. With signal averaging of at least 100 beats, the noise level was reduced to 0.5$\mu$V$_rms RTI$, which is low enough to detect LPs. The developed HRECG will provide a new advanced functionality to interpretive ECG analyzers.

  • PDF

Digital approach integrating 3D facial scan and a virtual mockup for esthetic restorative treatment: A case report (심미보철 수복을 위한 3차원 안면스캔과 가상 보철물 시각화를 이용한 디지털 치료 증례)

  • Mai, Hai Yen;Choi, Yong-Do;Lee, Du-Hyeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.425-431
    • /
    • 2019
  • This clinical case report describes the digital workflow that combines a face scan, cone beam computed tomography and an intraoral scan to visualize the outcome of prosthodontic treatment in the anterior region. This approach improves communication between clinic, laboratory and patients. A patient with healthy general condition came for a restorative treatment to treat post-traumatic central incisors of maxilla. A virtual patient replica was made by incorporating a face scan, cone beam computed tomography and an intraoral scan. Design mockup of definitive restorations was shown to the patient and modified according to the patient's desire. This digital workflow facilitates the fabrication of optimal esthetic restorations, and enhances the predictability of outcome of restorations.

A Study on the Miniaturization of Angle Head Spindle Case for Cutting in Narrow Spaces (협소 공간 절삭가공용 앵글 헤드 스핀들 케이스 소형화에 대한 연구)

  • Sung, Chul Hoon;Han, Sung Gil;Kim, Sung Hoon;Song, Chul Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.6
    • /
    • pp.98-105
    • /
    • 2019
  • In order to improve the fuel economy and dynamic behavior of automobiles, the weight reduction tendency of automobile parts is obvious. Also, in order to maximize assembly and maintenance convenience, various parts are integrated and modularized. Multi-piece methods require many manufacturing processes and become a factor of lowering the strength of parts. It is advantageous to overcome the disadvantages by integrally manufacturing to reduce the processing steps and ensure the strength of the parts. However, when it is necessary to process in a narrow space inside the part, it is impossible to process with the existing spindle. The angle head spindle is only a component of a machine tool, but it is a core part that requires high technology and is highly utilizable in products requiring high precision machining. Therefore, various and continuous studies needs for angle head spindles in areas such as vibration absorption, operational safety, excellent dimensional stability, and strength. In this paper, we propose an optimal design for angle head spindle by performing structural analysis and shape optimization for angle head spindle gear and case.

Numerical and experimental investigation for monitoring and prediction of performance in the soft actuator

  • Azizkhani, Mohammadbagher;sangsefidi, Alireza;Kadkhodapour, Javad;Anaraki, Ali Pourkamali
    • Structural Engineering and Mechanics
    • /
    • v.77 no.2
    • /
    • pp.167-177
    • /
    • 2021
  • Due to various benefits such as unlimited degrees of freedom, environment adaptability, and safety for humans, engineers have used soft materials with hyperelastic behavior in various industrial, medical, rescue, and other sectors. One of the applications of these materials in the fabrication of bending soft actuators (SA) is that they have eliminated many problems in the actuators such as production cost, mechanical complexity, and design algorithm. However, SA has complexities, such as predicting and monitoring behavior despite the many benefits. The first part of this paper deals with the prediction of SA behavior through mathematical models such as Ogden and Darijani, and its comparison with the results of experiments. At first, by examining different geometric models, the cubic structure was selected as the optimal structure in the investigated models. This geometrical structure at the same pressure showed the most significant bending in the simulation. The simulation results were then compared with experimental, and the final gripper model was designed and manufactured using a 3D printer with silicone rubber as for the polymer part. This geometrical structure is capable of bending up to a 90-degree angle at 70 kPa in less than 2 seconds. The second section is dedicated to monitoring the bending behavior created by the strain sensors with different sensitivity and stretchability. In the fabrication of the sensors, silicon is used as a soft material with hyperelastic behavior and carbon fiber as a conductive material in the soft material substrate. The SA designed in this paper is capable of deforming up to 1000 cycles without changing its characteristics and capable of moving objects weigh up to 1200 g. This SA has the capability of being used in soft robots and artificial hand making for high-speed objects harvesting.

Industrial analysis according to lithography characteristics of digital micromirror device and polygon scanner (Digital Micromirror Device와 Polygon scanner의 Lithography 특성에 따른 산업적 분석)

  • Kim, Ji-Hun;Park, Kyu-Bag;Park, Jung-Rae;Ko, Kang-Ho;Lee, Jeong-woo;Lim, Dong-Wook
    • Design & Manufacturing
    • /
    • v.15 no.4
    • /
    • pp.65-71
    • /
    • 2021
  • In the early days of laser invention, it was simply used as a measuring tool, but as lasers became more common, they became an indispensable processing tool in the industry. Short-wavelength lasers are used to make patterns on wafers used in semiconductors depending on the wavelength, such as CO2 laser, YAG laser, green laser, and UV laser. At first, the hole of the PCB board mainly used for electronic parts was not thin and the hole size was large, so a mechanical drill was used. However, in order to realize product miniaturization and high integration, small hole processing lasers have become essential, and pattern exposure for small hole sizes has become essential. This paper intends to analyze the characteristics through patterns by exposing the PCB substrate through DMD and polygon scanner, which are different optical systems. Since the optical systems are different, the size of the patterns was made the same, and exposure was performed under the optimal conditions for each system. Pattern characteristics were analyzed through a 3D profiler. As a result of the analysis, there was no significant difference in line width between the two systems. However, it was confirmed that dmd had better pattern precision and polygon scanner had better productivity.

Synergetic effect of soluble whey protein hydrolysate and Panax ginseng berry extract on muscle atrophy in hindlimb-immobilized C57BL/6 mice

  • Han, Min Ji;Shin, Ji Eun;Park, Seok Jun;Choung, Se-Young
    • Journal of Ginseng Research
    • /
    • v.46 no.2
    • /
    • pp.283-289
    • /
    • 2022
  • Background: Sarcopenia, defined as loss of muscle mass and strength with age, becomes a public health concern as the elderly population increases. This study aimed to determine whether the mixture of soluble whey protein hydrolysate (WPH) and Panax ginseng berry extract (GBE) has a synergetic effect on sarcopenia and, if so, to identify the relevant mechanisms and optimal mixing ratio. Methods: In the first experiment, C57BL/6 mice were hindlimb immobilized for one-week and then administered WPH 800 mg/kg, GBE 100 mg/kg, WPH 800 mg/kg+ GBE 100 mg/kg mixture, and Fructus Schisandrae extract (SFE) 200 mg/kg for two weeks. In the second experiment, experimental design was same, but mice were administered three different doses of WPH and GBE mixture (WPH 800 mg/kg+ GBE 100 mg/kg, WPH 800 mg/kg+ GBE 90 mg/kg, WPH 1000 mg/kg+ GBE 75 mg/kg). Results: In the first experiment, we confirmed the synergetic effect of WPH and GBE on muscle mass and identified that GBE was more effective on the protein synthesis side, and WPH tended to be slightly more effective for protein degradation. In the second experiment, among three different ratios, the WPH 800 mg/kg+ GBE 100 mg/kg was most effective for muscle mass and strength. The mixtures activated muscle protein synthesis via PI3K/Akt/mTORc1 pathway and inhibited muscle protein degradation via suppressing ubiquitin-proteasome system (UPS) and autophagy-lysosome system (ALS), and these effects were more GBE dose-dependent than WPH. Conclusion: The WPH and GBE mixture having a synergetic effect is a potential agent to prevent sarcopenia.

A Study on the Repair Work for Spindle Key with Damaged Part in Planner Miller by Directed Energy Deposition (DED 방식을 적용한 플래너 밀러의 손상된 스핀들 키 보수 작업에 관한 연구)

  • Lee, Jae-Ho;Song, Jin-Young;Jin, Chul-Kyu;Kim, Chai-Hwan
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.4_2
    • /
    • pp.699-706
    • /
    • 2022
  • In this study, Directed energy deposition (DED) among additive manufacturing is applied to repair damaged spindle key parts of planner miller. The material of the spindle key is SCM415, and the P21 Powder is used. In order to find the optimal deposition conditions for DED equipment, a single-line deposition experiment is conducted to analysis five parameters. The laser power affects the width, and the height is a parameter affected by coaxial gas and powder gas. In addition, laser power, powder feed rate, coaxial gas, and powder gas are parameters that affect dilution. Otimal deposition is that 400 W of laser power, 4.0 g/min of powder feed rate, 6.5 L/min of coaxial gas, 3.0 L/min of powder gas and 4.5 L/min of shield gas. By setting the optimum conditions, a uniform deposition cross section in the form of an ellipse can be obtained. Damage recovery process of spindle key consists of 3D shape design of the base and deposition parts, deposition path creation and deposition process, and post-processing. The hardness of deposited area with P21 powder on the SCM415 spindle key is 336 HV for the surface of the deposition, 260 HV for the boundary area, and 165 HV for the base material.

Strength Analysis of Complex Gear Train for Transmission of 21-Ton Grade Wheel Excavator (21톤급 휠 굴착기용 트랜스미션의 기어 트레인에 대한 강도 해석)

  • Lee, JunHee;Bae, MyungHo;Cho, YonSang
    • Tribology and Lubricants
    • /
    • v.38 no.5
    • /
    • pp.179-184
    • /
    • 2022
  • The power train of transmission for 21-ton grade wheel excavator makes use of a complex gear train composed of a planetary and helical gear system to drive the wheel excavator by transmitting power to the axle. The complex gear train with a shift mode is an important part of the transmission because of strength problems in an extreme environment. To calculate the specifications of the complex gear train and analyze the gear bending and compressive stresses of the complex gear train, this study analyzes gear bending and compressive stresses accurately for the optimal design of the complex gear train with respect to cost and reliability. In this article, the gear bending and compressive stresses of the complex gear train are calculated using the Lewes and Hertz equation. Evaluating the results with the data of the allowable bending and compressive stress from the stress and number of cycles curves of the gears verified the calculated specifications of the complex gear train. A computer structure analysis is performed with the 3D model of the planetary and helical gears to analyze the structure strength of the complex gear train. The results demonstrate that the durability and strength of the complex gear train are safe, because the safety factors of the bending and compressive stresses are more than 1.0.

Verification of External Magnetization based EM Technique for Diagnosing Residual Tensile Stress in Aged PSC Structures (노후 PSC 구조물의 잔여 긴장 응력 진단을 위한 외부 자화 EM 기법 검증)

  • Soon-Jeon Park;Sehwan Park;Jaehoon Choi;Kyo-Young Jeon;Junkyeong Kim
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.4
    • /
    • pp.251-257
    • /
    • 2023
  • This study entailed an investigation of a tensile stress measurement method for prestressed concrete (PSC) tendons by utilizing external magnetization. The target of this study are PS structures that have been constructed and in use. An optimal external magnetization based elasto-magnetic (EM) sensor was designed using finite element analysis considering various factors, such as coil arrangement and size, that could influence the PS tendons inside the PSC girder. The residual tensile stress resulting from the external magnetization of the girder was then determined. Further, theoretical verification was performed using the numerical and material data used in the finite element analysis for sensor design. The calculated values of strength of magnetization at the target location were matched with the finite element analysis results. Thus, the designed sensor and the feasibility of magnetizing the tendons inside the PSC I-girder using an EM sensor were validated.

Analysis of a Two-Phases System of Mass Transfer and Electro-Reduction of Uranium(VI) in Nitric Acid-Hydrazine Media (질산-하이드라이진 매질에서 우라늄(VI)의 물질전달과 전기적 환원을 갖는 이 상계의 해석)

  • Kim, K.W.;Yoo, J.H.;Park, H.S.;Kim, J.D.;Aoyagi, H.;Yoshida, Z.
    • Nuclear Engineering and Technology
    • /
    • v.27 no.2
    • /
    • pp.216-225
    • /
    • 1995
  • Simulation for a dynamic analysis of the electrolytic preparation of U(IV) in two-phases system, which consisted of mass transfer of U(VI) from TBP phase into HNO$_3$ solution and electrolytic re-duction of U(VI) to U(IV) at a cathode in aqueous phase, was carried out in order to establish the most suitable operating condition and best electrode area as basic design data for the system. It was found that maintaining an appropriate mass transfer rate was more significant rather than enlarging the surface area of the cathode for more effective production yield of U(IV). The electrode area and the operation time affected deeply the production composition of U(IV) in the resulting aqueous phase. And optimal electrode areas ore evaluated to meet production criteria of U(IV) of resulting solution in several system conditions. Though about 0.37M HNO$_3$ was preferable to prepare the solution of U(IV), nitric acid concentration should be higher than 0.5M to prevent a hydrolysis of U(IV) in the aqueous phase.

  • PDF