• 제목/요약/키워드: Cytologic/histologic correlation

검색결과 23건 처리시간 0.021초

자궁경부질 도말 검사 정도 관리과정으로서의 세포 및 조직진단의 비교 분석과 10% 무작위 재선별과의 비교 분석 (Quality Improvement Methods in Cervico-vaginal Cytology; Cytologic/Histologic Correlation vs. 10% Random Rescreening)

  • 윤길숙;허주령;손경희;김온자;공경엽
    • 대한세포병리학회지
    • /
    • 제9권2호
    • /
    • pp.129-137
    • /
    • 1998
  • Although the success of the Papanicolaou test as a screening tool of cervical cancer is evident, there still exists $2{\sim}5%$ of discrepancy rate by both human and machine. To improve the qualilty of cervico-vaginal cytology, the authors compared cervicovaginal smear with cervical biopsy diagnoses, and analysed the causes of discrepancies. Among 30,922 cervicovaginal smears from June 1996 to April 1997 at our hospital, there were 271 cases of cervicovaginal smear with subsequent cervical punch or LEEP cone biopsies within several months. The biopsies and smears from a total of 98 discordant cases were reviewed. The discrepancy was attributed to sampling errors in 43 cases(43.9%), and to cytologic diagnosis in 49 cases(50.0%). Among these, 43 cases were interpretative errors(categories A;19, B;16 and C;8) whereas six cases were screening errors(categories B:2 and C:4). Among cervical biopsy cases, errors were present in four. As for 10% random rescreening, cytotechnologists reviewed 3,196 of 30,922 smears during the same period, There were 43 cases of screening error(categories A;27, B;16). Cytologic/histologic correlation was superior to 10% random rescreening of negative cases. The most effective method for quality improvement in cervicovaginal cytology was to implement both quality control(rescreening) and qualify assurance(cytologic/histologic correlation) programs.

  • PDF

Papanicolaou smear에서 자궁내막암의 세포학적 진단의 의의 : 조직유형, 분화도 및 병기와의 관련성 (Significance of Cytologic Detection of Endometrial Carcinoma in Papanicolaou Smear: The Relevance of Histologic Type, Grade and Stage)

  • 홍성란;김희숙;박종숙
    • 대한세포병리학회지
    • /
    • 제4권2호
    • /
    • pp.93-99
    • /
    • 1993
  • The cytologic detection of endometrial carcinoma in Papanicolaou(Pap) smear according to histologic type, grade and stage was studied in 49 patients. The smears of patients who had histologically confirmed were retrospectively evaluated by the Bethesda System. The cytologic diagnosis of endometrial carcinoma was made in 61% (39/49) of patients, atypical glandular cells of undetermined significance (AGCUS) in 16% (8/49) and within normal limits in 23% (11/49). The positive rate for AGCUS and carcinoma was correlated to the histologic type, grade and stage. The cytologic grade revealed a good correlation with histologic grade, too. In conclusion, the presence of cancer cells in Pap smear suggests the tumor in high grade and high stage. Additionally, cytologic detection of AGCUS or carcinoma needs a further diagnostic evaluation. The Pap smear is a valuable method to screen for endometrial carcinoma.

  • PDF

유방 병변 256례의 세침흡인 세포학적 진단 및 조직학적 진단과의 비교연구 (Comparison of Fine Needle Aspiration Cytologic Diagnoses and Histologic Diagnoses in 256 Breast Lesions)

  • 강미선;정수진;윤혜경
    • 대한세포병리학회지
    • /
    • 제8권2호
    • /
    • pp.120-128
    • /
    • 1997
  • Fine needle aspiration cytology of breast lesion is well known as a simple, economic and effective diagnostic modality. For the evaluation of cytohistologic correlation, 256 cases of cytologic smears and subsequent histologic sections during 2-year period from Jan. 1995 to Dec. 1996 were reviewed. 1. Fifteen cases(5.9%) were proven as insufficient for evaluation, and 13 of them were fibrocystic change histologically. One case of carcinoma exhibiting sufficient amount of aspirates with no malignant cells on smear was regarded as inadequate. 2. Cytohistologic correlation of 240 cases revealed sensitivity 87.0%, specificity 100.0%, positive predictive value 100.0%, negative predictive value 97.0%, false positive rate 0.0% and false negative rate 13.0%. Total diagnostic accuracy is 95.7%. 3. Total 6 cases of negative were due to small amount of aspirates containing scantiness of malignant cells in two and underestimation in four. 4. Diagnostic concordance rates of fibrocystic change and fibroadenoma were 95.5% and 80.0%, respectively. Diagnostic discrepancies were noted in 7 cases of fibrocystic change and 6 cases of fibroadenoma, however, cytologic discrimination of two entities was not easy in seven of them. 5. In a case of phyllodes tumor and a case of duct ectasia, the discrepancy was due to targeting error. Other three cases(lymphoma, adenomyoepithelioma and granulomatous mastitis) were misinterpreted because of poor acquaintance with those entities. Diagnostic accuracy of fine needle aspiration cytology of breast lesions are relatively high. However, good technique on aspiration and adequate interpretation are necessary to reduce the false negative rate and the discrepancy between cytologic and histologic diagnoses.

  • PDF

세침 흡인 세포학적 검사로 진단된 지방육종 -3 예 보고- (Fine Needle Aspiration Cytology of Liposarcoma - Report of 3 cases -)

  • 고은석;진소영;권태정;이동화
    • 대한세포병리학회지
    • /
    • 제1권2호
    • /
    • pp.139-146
    • /
    • 1990
  • The application of fine needle aspiration (FNA) cytology to the soft tissue tumors had been neglected. In recent years, however, FNA has been used increasingly in the preoperative diagnosis of these tumors due to its usefulness and accuracy. We present 3 cases of liposarcoma, myxoid, myxoid with round cell, and pleomorphic, diagnosed by FNA cytology with histologic confirmation. Good correlation between histologic and FNA cytologic findings was found. Although the cytologic appearances of liposarcomas varied with histologic type, the main criterion was the presence of atypical multivacuolated lipoblast with characteristically scalloped nuclei.

  • PDF

세침흡인 검사물을 이용한 유방암세포 에스트로젠수용체 분석 : 동결절편조직과의 비교 (Estrogen Receptor Analysis in Fine Needle Aspirates and Frozen Sections from Human Breast Carcinomas)

  • 공경엽;안세현;박건춘;최기영;유은실;이인철
    • 대한세포병리학회지
    • /
    • 제5권1호
    • /
    • pp.10-14
    • /
    • 1994
  • The expression of sex steroid hormone receptors by neoplastic cells is an important predictor of response to hormone therapy. Thus, the selection of treatment modality is often based on the identification of receptors in tumor tissue. Various monoclonal antibodies of high specificity are now available for analyzing the estrogen receptor (ER). With these antibodies, biochemical enzyme immunoassay and immunohistochemistry using histologic sections have been used for ER analysis. We used fine needle aspirates from 15 human primary breast carinomas for the analysis of ERs. The semiquantitative receptor values obtained in cytologic specimens were correlated well with those from histologic specimens. The results of ER in fine needle aspirates were concordant with ER in histologic specimens(r=0.94). Only three cases showed a little difference in staining intensity and proportion of positive cells. Our results showed a good correlation between the receptor values determined in cytologic smears and those determined in tissue sections. It is suggested that measurement of the ER in cytologic smears may be a reliable technique which can be performed on aspiration cytologic samples.

  • PDF

자궁경부 세포도말 검사에시 미세침윤성 편평세포암종의 세포학적 분석 (The Cytologic Analysis of Microinvasive Squamous Cell Carcinoma of the Uterine Cervix on Cervical Smear)

  • 최현주;박인애
    • 대한세포병리학회지
    • /
    • 제12권1호
    • /
    • pp.31-37
    • /
    • 2001
  • Whlie cytologic characteristics of squamous dysplasia, carcinoma in situ, and invasive squamous cell carcinoma of the uterine cervix are well documented, relatively few studios have dealt with the cellular features of microinvasive carcinoma. In order to describe the cellular characteristics of microinvasive squamous cell carcinoma, we retrospectively reviewed 45 cervovaginal smears(15 carcinoma in situ, 15 microinvasive cancer, 15 invasive cancer) which were confirmed by histologic examination of specimens obtained by hysterectomy at the Seoul National University Hospital during S years from 1995 to 1999. The cytologic features about tumor diathesis, inflammatory background, ceil arrangement, anisonucleosis, nuclear membrane irregularity, nuclear chromatin pattern, and nucleoli were observed. The cytologlc characteristics of microinvasive squamous cell carcinoma of the uterine cervix are syncytial pattern, mild tumor diathesis, the irregularity of nuclear membrane, irregularly distributed nuclear chromatin, and occurrence of micronucleoli. But, correlation between the depth of Invasion and the cytologic feature had limited value.

  • PDF

폐장 결절성 병변에 대한 경흉 세침천자 세포학적검사 결과의 분석 (Analysis of Transthoracic Fine Needle Aspiration Cytologic Diagnoses of Pulmonary Nodules)

  • 박찬금;이중달
    • 대한세포병리학회지
    • /
    • 제6권2호
    • /
    • pp.133-139
    • /
    • 1995
  • To evaluate the sensitivity and specificity of transthoracic fine needle aspiration cytology(TFNAC) in the preoperative diagnosis of pulmonary nodules, a retrospective analysis was carried out on a consecutive series of 200 TFNACs. They included 186 primary malignant tumors, 66 squamous cell carcinomas, 65 adenocarcinomas, 36 small cell carcinomas, 7 large ceil carcinomas, 4 carcinomas, 8 others, 9 metastatic tumors, and 5 benign tumors. On cytohistologic correlation of malignant pulmonary tumors, the procedure had a sensitivity of 97.3% and a specificity of 100%. A 86.6% correct correlation between the cytologic and histologic diagnoses was achieved. Five out of the 7 undifferentiated large cell carcinomas, 10 out of the 65 adenocarcinomas, 2 out of the 36 small cell carcinomas, and 2 out of the 66 squamous cell carcinomas were turned out to be mistyped in cytologic diagnosis. We concluded that TFNAC is a highly sensitive and specific preoperative diagnostic procedure in the investigation of patients with discrete pulmonary nodules in whom the specific ceil type of the malignant neoplasm has important implications in treatment modality and prognosis.

  • PDF

기관지경검사에서 객담세포검사의 암양성률에 대한 연구 (Cytologic examination sputum and bronchial secretion bronchofiberscopic sampling procedures in lung cancer)

  • 김송명
    • Journal of Chest Surgery
    • /
    • 제16권1호
    • /
    • pp.138-145
    • /
    • 1983
  • The value of exfoliative sputum cytology in diagnosis of lung cancer has been accepted with bronchoscopic technique and results has been much improved by foreign investigators, but there was not presented accurate reports for sputum cytologic evaluation in Korea. We tried to find indicators of cytologic tests result in our hospital. During the period between May, 1980 and August, 1982, 400 patients, tested at Department of Thoracic and Cardiovascular Surgery of Kosin Medical College, had diagnostic bronchofiberscopic examination, and the cytologic study of sputum and bronchial secretions were performed. The sputum or bronchial secretion during bronchofiberscopic examination were obtained with various methods and the name of specimen were labeled as I, ASPIRATION SPUTUM, which was collected initially endobronchial sputum as introducing of scope, II, WASHING SPUTUM, which was collected washing bronchial secretion, III, BRUSHING SPUTUM, which was washing solution of brushing instrument and endobronchial sputum after brushing of lesions, IV, POST-SCOPIC SPUTUM, which was expectorated sputum as soon as removing of scopic instrument, V, ALL SPUTUM CYTOLOGY & CELL BLOCK, which was collected all specimen of above procedures. The diagnostic results of bronchofiberscopic examination was disclosed 174 cases [43.5%] of proved lung cancer, 47 cases [11.8%] of suspected lung cancer in grossly, and 179 cases [44.8%] of others finding except cancer. Patient with bronchofiberscopically grossly evidence of lung cancer which were not confirmed histologically or cytologically were excluded from this cytologic study. Histologic and cytologic correlation in proven lung cancer, 174 cases was revealed that number of cytologic positive patients were 45 cases [38.7%] among the 117 cases of proved squamous cell carcinoma, 12 cases [38.7%] among hislogically unknown cancer 34 cases and 6 cases [33.3%] among small cell undifferentiated carcinoma 18 Gases. Total cytologic positive result was presented as 67 cases [38.3%]. The other type of lung cancer, histologically, could not comparison because of small cases. The sequence of positive cytologic result in I-V specimen were disclosed as II, WASHING SPUTUM 57.6%, and V, ALL SPUTUM & CELL BLOCK 41.4%. The I, III & IV result were 28.6%, 22.2% and 26.1% respectively.

  • PDF

종격동의 점액성 지방육종의 세침흡인 세포학적 소견 -1예 보고- (Fine Needle Aspiration Cytology of Myxoid Liposarcoma of the Mediastinum -A case report -)

  • 주희재;정순희;김호근
    • 대한세포병리학회지
    • /
    • 제1권2호
    • /
    • pp.185-190
    • /
    • 1990
  • The cytologic findings in fine needle aspiration of a case of myxoid liposarcoma of the mediastinum are described. The smear and cell block of the aspirate revealed solid clusters with background of amorphous material and scattered single tumor cells. The clusters were moderately cellular and consisted of atypical lipoblasts in varying stages of differentiation and delicate plexiform capillaries. Good correlation was found between the histologic and cytologic findings in the fine needle aspirates. The differential diagnosis between myxoid liposarcoma and other myxoid soft tissue tumors is discussed.

  • PDF