• 제목/요약/키워드: Cylindrical Tube

검색결과 176건 처리시간 0.024초

반응표면법을 이용한 실린더 튜브 고탄성체 성형의 형상 정확도 예측 (Prediction of Shape Accuracy in Elastomer-Forming of a Cylindrical Tube by a Response Surface Method)

  • 김경태;이근안;최석우;이형욱;이용신
    • 소성∙가공
    • /
    • 제17권3호
    • /
    • pp.218-224
    • /
    • 2008
  • A recent trend in automotive parts has been an integration of sub-assemblies with unified shapes. Tube structures also have been integrated to one body structure by using a near net shape forming instead of adopting welding. A cylindrical elastomer-forming process can be utilized to form a steel tube compressed in a radial direction. This process has some advantages compared to a hydro-forming or a swaging process in the viewpoint of a lower investment and a higher productivity. In order to predict a feasible specification of products within a work capability of the elastomer-forming equipment developed previously, effects of geometrical parameters of a tube on its shape accuracy are examined. Two characteristic parameters to account for the shape accuracy are chosen. One is the curvature radius at the corner part and the other is the straight ratio of the formed region. Careful examination of two parameters has led that the shape accuracy can be easily predicted by the regression equation obtained from the response surface method.

배관측 정렬 방법을 이용한 다중레이저 스캐닝 기반의 3차원 배관복원 (A 3-D Tube Reconstruction based on Axis Alignment of Multiple Laser Scanning)

  • 백승해;박순용;김승호
    • 제어로봇시스템학회논문지
    • /
    • 제17권11호
    • /
    • pp.1159-1167
    • /
    • 2011
  • A novel 3D tube scanning technique is proposed. The proposed tube scanning technique is developed for a special tube inspection module which consists of four line-lasers and one camera. Using the scanning module, we can reconstruct the 360 degree shapes of the inner surfaces of a cylindrical tube. From an image frame captured by the camera, we reconstruct a partial tube model based on four laser triangulations. Then by aligning such partial models with respect to a reference tube axis, a complete 3D shape of the tube is reconstructed. The tube axis in each reconstructed frame is aligned with a 3D Euclidean transformation to the reference axis. Several experiments show that the proposed method can align multiple tube axes very accurately and reconstruct 3D shapes of a tube with very low shape distortion.

침지형 생물 반응기 공정에서 플럭스 향상을 위한 공기 세척 효과에 관한 연구 (Control of Membrane Fouling in Submerged Membrane Bioreactor(MBR) using Air Scouring)

  • 신동환;백병도;장인성
    • 대한환경공학회지
    • /
    • 제30권9호
    • /
    • pp.948-954
    • /
    • 2008
  • 침지형 MBR 공정에서 막 오염과 플럭스 감소의 주요 원인인 케이크층에 의한 저항을 저감하기 위하여 분리막 모듈의 외부에 원통형 관을 도입하였다. 도입된 원통형관 안에 노즐과 산기관을 적용하여 공기 주입량에 따른 공기와 액체의 2상흐름(Two phase flow)중 slug 흐름을 유도하여 공기 방울에 의한 막세정의 효과를 비교 분석하였다. 실험결과 동일한 유량의 공기를 공급할 경우 노즐에서 발생한 공기방울이 원통형관으로 유입되면서 효율적인 slug 흐름을 형성으로 산기관을 사용한 공급 방식보다는 막오염 방지에 효과적이었음을 알 수 있었다. 그러나 노즐로 공급되는 공기의 유량을 최적화하지 않는다면 원통형 관의 벽 부분부터 활성슬러지 혼합액이 퇴적하게 되거나 막간에 슬러지가 퇴적되어 관 내부의 급격한 막힘 현상이 발생하여 일정시간이 경과하면, 오히려 산기관보다 급격한 막오염 현상을 나타냄을 알 수 있었다. 또한 원통형 관 내부에 침지된 분리막의 면적의 최적 비율, A$_m$/A$_t$가 비율이 존재하는 것을 확인할 수 있었다. 산기관의 경우에는 A$_m$/A$_t$ 비율이 0.27일 때 최소화된 막오염이 관찰된 반면에, 노즐의 경우에는 A$_m$/A$_t$ 비율이 0.55일 때 막오염이 최소값을 보였다. 따라서 상승하는 공기방울에 의한 막오염 저감효과는 관 내부의 중공사막이 차지하고 있는 비율, A$_m$/A$_t$에 크게 의존하고 있으며, 산기관과 노즐의 경우 그 최적비율은 각각 다름을 알 수 있었다.

단열관을 위한 원통 환상공간 내에서의 복합 열전달 (Conjugate Heat Transfer in Cylindrical Annulus for an Insulated Tube)

  • 강병희;양성환;권순석
    • 설비공학논문집
    • /
    • 제7권4호
    • /
    • pp.633-641
    • /
    • 1995
  • The effect of the gap width on conjugate heat transfer in the cylindrical annulus for an insulated tube has been studied numerically by the finite difference method. The parameters considered here are the Rayleigh number, Ra, the dimensionless insulated wall thickness, $W/D_i$ and the dimensionless gap width, S/W. As S/W increases, the mean wall temperature increases at the inside wall of annulus and decreases at the outside walls of annulus and the insulated tube at $S/W{\leq}0.5$, and then slightly increases at $Re=10^4$, $W/D_i=1.47$. The heat transfer rate decreases at $S/W{\leq}0.5$ and then increases apparently as S/W increases at $Re=10^4$, W/Df=1.47. Therefore, it is considered that $$S/W{\sim_=}0.5$$ is the optimum gap width for the effect of insulation at $Re=10^4$, $W/D_f=1.47$.

  • PDF

액압 성형을 이용한 내부복합파형 고효율 이중관 제조 기술 (Manufacturing of High-Performance Double Layered Tube with Corrugated Internal Pattern via the Hydroforming Process)

  • 한상욱;김대용;문영훈
    • 소성∙가공
    • /
    • 제31권3호
    • /
    • pp.143-150
    • /
    • 2022
  • The purpose of this study was to investigate an innovative hydroforming process for the cost-effective manufacturing of double layered tube with circumferentially corrugated patterns. Conventional double pipe heat exchanger has relatively poor heat transfer efficiency because of the limited contact area resulting from the concentrically arranged simple cylindrical structure. As a promising alternative to enhance heat transfer efficiency, double layered tube with corrugated internal pattern was considered in this study. To fabricate corrugated inner tube, innovative tube hydroforming system was developed. The customized loading paths were established using the simulated forming pressure and contracting stroke at various bar diameters. Experimentally obtained cross-sectional profiles were analyzed to evaluate the reliability and applicability of the hydroformed tube with various patterns. The results demonstrate that the proposed hydroforming process can be a feasible alternative for manufacturing high-performance double-tube heat exchangers.

원형 이중관 내에서 PIV 기법을 이용한 선회유동에 관한 실험적 연구 (An Experimental Study on Swirling Flow in a Cylindrical Annuli by Using PIV Technique)

  • 장태현
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권5호
    • /
    • pp.666-674
    • /
    • 2003
  • An experimental investigation was performed to study the characteristics of turbulent swirling flow in an axisymmetric annuli. The swirl angle measurements were performed by flow visualization technique using smoke and dye liquid along the test tube. Using the Particle Image Velocimetry method, this study found the time-mean velocity distribution and turbulent intensity with swirl for Re = 20.000. 30.000, 50.000. and 70.000 along longitudinal sections and the results appear to be physically reasonable.

비정상유동장에서 모세관점도계의 점도측정 (Viscosity Measurement in the Capillary Tube Viscometer under Unsteady Flow)

  • 박흥준;유상신;서상호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.825-828
    • /
    • 2000
  • The objective of the present study is to develop a new device that the viscous characteristics of fluids are determined by applying the unsteady flow concept to the traditional capillary tube viscometer. The capillary tube viscometer consists of a small cylindrical reservoir, capillary tube, a load celt system oat measures the mass flow rate, interfacers, and computer. Due to the small size of the reservoir the height of liquid in the reservoir decreases as soon as the liquid in the reservoir drains out through the capillary and the mass flow rate in the capillary decreases as the hydrostatic pressure in the reservoir decreases resulting in a decrease of the shear rate in the capillary tube. The instantaneous shear rate and. driving force in the capillary tube are determined by measuring the mass flow rate through the capillary, and the fluid viscosity is determined from the measured flow rate and the driving force.

  • PDF

형상이 다른 수평 원형 전열관의 응축 성능에 관한 연구 (A Study on the Condensation Performance for the Horizontal Heat Transfer Tubes with Various Fin Attached)

  • 한규일;박종운
    • 수산해양교육연구
    • /
    • 제4권1호
    • /
    • pp.47-61
    • /
    • 1992
  • An experimental study was carried out to investigate the condensation performance for the horizontal cylindrical heat transfer tube with various fin attached using R-11 vapor. The heat transfer tube used in this study was supplied by SUNG HYUNG METAL CO., LTD. Four different types of heat transfer tubes (plain tube, SH-CYR tube, thermocor tube and thermoexcel tube) were used. Each tube was surrounded by circular acrylate tube, and R-11 gas heated by boiler flows into the acrylate tube. Cooling water counter-flows in heat transfer tubes. Heat transfer coefficient of the plain tube from measured data was compared with those of three other tubes. The results are summarized as follows: 1. As the cooling water temperature decreased, the liquid film of R-11 turned to droplet drop on the top surface of the horizontal tube. 2. Heat transfer coefficient calculated theoretically was higher than that obtained from the experimental data. 3. As far as the condensation concerns the thermocor tube is the highest, the SH-CYR tube is the second, and the thermoexcel tube is the third excluding the plain tube.

  • PDF

열탄성 구조물의 최적설계 (Design Optimization of Thermo-Elastic Structure)

  • 조희근;박영원
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.381-384
    • /
    • 2000
  • Multi-disciplinary optimization design concept can provide a solution to many engineering problems. In the field of structural analysis, much development of size or topology optimization has been achieved in the application of research. This paper demonstrates an optimum design of a multi-layer cylindrical tube which behaves thermoelastically. A multi-layer cylindrical tube that has several different material properties at each layer is optimized within allowable stress and temperature range when mechanical and thermal loads are applied simultaneously. To analyze these problems using an efficient and precise method, the optimization theories are adopted to perform thermoelastic finite element analysis.

  • PDF

원관내 밸브 디스크 회전각의 변화에 따른 유동특성 (Characteristics of flow for various rotating angle in cylindrical tube)

  • 심요셉;허형석;변동근;서용권
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.75-78
    • /
    • 2002
  • In this paper, flow on the rear region of a butterfly valve was analysed by using numerical and experimental methods. The butterfly-valve disk angle is changed as 0-60 degree and the uniform flow velocity was fixed In this experiment. It was shown that the numerical results are similar to the experimental results. General discussions are given to the flow-pattern change upon the disk angle of the valve.

  • PDF