• Title/Summary/Keyword: Cylindrical Tube

Search Result 176, Processing Time 0.026 seconds

Acoustic Characteristics of Sand Sediment Slab with Water- and Air-filled Pore

  • Roh Heui-Seol;Lee Kang Il;Yoon Suk Wang
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.223-226
    • /
    • 2001
  • Acoustic pressure transmission coefficient and phase velocity are measured as the functions of water porosity and air porosity in sand sediment slabs with water- and air-filled pores. Pores in the sand sediment slab we modeled as the structure of circular cylindrical tube shape filled with water and air. The first kind(fast) wave and second kind (slow) wave, identified by Biot, in the solid and fluid mixed medium are affected by the presence of water and air pores. Acoustic characteristics of such porous medium in water are also theoretically investigated in terms of the modified Biot-Attenborough (MBA) model, which uses the separate treatment of viscosity effect and thermal effect in non-rigid porous medium with water- and air-filed pores. The information on the fast waves introduces new concepts of the generalized tortuosity factor and dynamic shape factor.

  • PDF

A Study on Characteristic of Ceramic Tube for Ozone Generation (오존발생용 세라믹 방전관 특성에 관한 연구)

  • Cho, Kook-Hee;Kim, Young-Bae;Lee, Hong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1724-1726
    • /
    • 2002
  • A novel ozonizer has been developed using a high-frequency surface discharge and a high purity alumina ceramic as its dielectric component. A thin ceramic layer, cylindrical in form, is adhered by a film-like induction electrode. An ac exciting voltage of frequency to 0.6 kHz from 1.0 kHz and $6{\sim}9kV$ peak-to-peak is applied between the electrodes to produce a stable high-frequency silent discharge for generation of ozone. A substantial reduction of the exciting voltage is also enabled by using a thin alumina ceramic layer. As a result, the ozonizer can easily produce ozone concentration($128g/m^2$ for oxygen) and power efficiency(360g/kWh for oxygen) without using a special enrichment means.

  • PDF

A UBET Analysis of The Warm Forming Process of Magnetron Anode (마그네트론 양극의 온간성형 공정의 UBET해석)

  • 조관형;배원병;김영호;양동열
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.04b
    • /
    • pp.204-208
    • /
    • 1995
  • Copper magnetron anode of a microwave-oven consists of an cylindrical outer-tube and various inner-vanes. The magnetron anode is produced by the complex process ; vane blanking, pipe cutting and sliver-alloy brazing of vanes. Recently, the backward extrusion process for forming vanes has been developed to avoid the complex procedures. The developed process is analyzed by using upper-bound elemental technique(UBET). In the UBET analysis, the upper-bound load, the configuration and the vane-height of final extruded product are determined by minimizing the total power consumption with respect to chosen parameters. To verify theoretical analysis, experiments have been carried out with pure plasticine billets at room temperature, using different web-thickness and number of vanes. The theoretical predictions both for forming load and vane-height are in reasonable agreement with the experimental results.

  • PDF

Two New Marine Sponges of Genus Halichondria (Halichondrida: Halichondriidae) from Korea

  • Kang, Dong-Won;Sim, Chung-Ja
    • Animal Systematics, Evolution and Diversity
    • /
    • v.24 no.2
    • /
    • pp.205-208
    • /
    • 2008
  • Two new marine sponges in family Halichondriidae, Halichondria ulleungensis n. sp. and H. hongdoenesis n. sp. are collected from Ulleungdo Island and Hongdo Island, Korea by SCUBA diving during 2003-2004. H. ulleungensis n. sp. is similar to H. corrugata Diaz, Pomponi and van Soest, 1993 in the type of spicule, but it is different in growth form and choanosomal skeleton. The growth form is encrusting, with numerous erected cylindrical tube, comparing with massive-lobate of H. corrugata. The choanosomal skeleton is confused with loosely arranged oxea tract, comparing with densely tracts with many spicules of H. corrugata. H. hongdoenesis n. sp. is similar to H. surrubicunda Hoshino, 1981 in type of spicule and growth form, but this species has two kinds (thick and thin) of oxea.

Fluroscopic Removal of the Foreign Bodies from Gastroesophagus Using the Magnet (자석을 이용한 식도 위 이물 제거술)

  • Park, Youn-Joon;Lee, Doo-Sun
    • Advances in pediatric surgery
    • /
    • v.13 no.2
    • /
    • pp.112-118
    • /
    • 2007
  • Ingested foreign bodies are common occurrences in the pediatric population. From October 2002 to April 2006, eight patients (6 male, mean age: $30.9{\pm}14.4$ months, range: 7~45 months) who had ingested metallic foreign bodies, such as bar magnets, coin-type magnets, screws, metal beads, and disk batteries, were selected for foreign body removal using a magnetic device under floroscopic control. A 1-cm-long cylindrical magnet (6 mm in diameter) was placed at the end of a 150-cm-long plastic tube from an IV set. The magnet was passed through the mouth into the stomach. Under fluoroscopic control, the magnet was maneuvered so that it attached to the metallic foreign bodies. The forgeign body was then easily removed by retracting the magnet with the metallic object attached. This procedure was successful in six patients of 8 patients. This procedure is a minimally-invasive and may avoid the use of anesthesics, endoscopy or surgery.

  • PDF

A New Approach to Design Method of the Solar Compound Parabolic Concentrator with Tubular Absorber (태양열집속집열기의 설계 방법에 관한 연구)

  • Kim, Seok-Jong;Lim, Sang-Hoon
    • KIEAE Journal
    • /
    • v.2 no.3
    • /
    • pp.33-38
    • /
    • 2002
  • The intermediate range of temperatures($100{\sim}300^{\circ}C$) which can be achieved with CPCs(Compound Parabolic Concentrators) without tracking device provides both economic and thermal advantages for solar collector design. The present paper summarizes critical design considerations for CPC with cylindrical absorber and its optical performance using ray tracing program. Concentration ratios vary as acceptance half angle, ratio of reflector height to aperture width and ratio of reflector area to aperture area. This effects showed that the concentration ratio was increased as acceptance angle but optimum ratio of reflector height to aperture width existed at critical value. As a result of ray tracing, solar ray losses was maximized at acceptance half angle and this problem was solved by increasing absorber tube diameter. The concentrating flux distribution on the absorber surface was uniform but peak flux existed.

Experimental Study on the Partial Oxidation Reforming of CH4/O2 Mixture in Two-Section Porous Media at High Pressure Conditions (고압 분위기에서 CH4/O2 혼합기의 2단 다공체 내 부분산화 개질에 관한 실험적 연구)

  • Guahk, Young Tae;Lee, Dae Keun;Kim, Seung Gon;Ko, Chang-Bog;Park, Jong-Ho
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.73-74
    • /
    • 2015
  • Synthesis gas such as hydrogen and carbon monoxide was produced from $CH_4/oxygen$ mixture using insulated pressurized porous media combustor. Experimentally, two cylindrical SiC foams with the different pore density were piled up in a quartz tube and fully premixed mixture was supplied in the axial direction. After stabilizing fuel-rich flame at the interface of the two foams at several pressure conditions, mole fractions of synthesis gases were measured by gas chromatography. Heat recirculation through the inner foam structure could extend the flow velocity of stable region over the laminar burning velocity. As the pressure increased, the rich flammability limit, $H_2/CO$ ratio, and module M increased.

  • PDF

Electrochemical corrosion behavior of atmospheric-plasma-sprayed copper as a coating material for deep geological disposal canisters

  • Sung-Wook Kim;Gha-Young Kim;Young-Ho Lee;Jun-Hyuk Jang;Chung-Won Lee;Jeong-Hyun Woo;Seok Yoon
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.4032-4038
    • /
    • 2023
  • Cu, which exhibits excellent corrosion resistance in underground environments, has been investigated as a canister material for use in the deep geological disposal of spent nuclear fuels. In this study, the technical viability of atmospheric plasma spraying for producing Cu-coated canisters was investigated. A high-purity Cu film (millimeter scale) was deposited onto a stainless-steel substrate using a plasma gun with a shroud structure. Potentiodynamic polarization studies revealed that the Cu film exhibited a sufficiently low corrosion rate in the groundwater electrolyte. In addition, no pitting corrosion was observed on the Cu film surface after accelerated corrosion studies. A prototype cylindrical Cu film was fabricated on a 1/20 scale on a stainless-steel tube to demonstrate the scalability of atmospheric plasma spraying in producing Cu-coated canisters.

The Evaluation for Attenuation Map using Low Dose in PET/CT System (PET/CT 시스템에서 감쇠지도를 만들기 위한 저선량 CT 평가)

  • Nam, So-Ra;Cho, Hyo-Min;Jung, Ji-Young;Lee, Chang-Lae;Lim, Han-Sang;Park, Hoon-Hee;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.134-138
    • /
    • 2007
  • The current PET/CT system with high quality CT images not only increases diagnostic value by providing anatomic localization, but also shortens the acquisition time for attenuation correction than primary PET system. All commercially available PET/CT system uses the CT scan for attenuation correction instead of the transmission scan using radioactive source such as $^{137}Cs,\;^{68}Ge$. However the CT scan may substantially increase the patient dose. The purpose of this study was to evaluate quality of PET images reconstructed by CT attenuation map using various tube currents. in this study, images were acquired for 3D Hoffman brain phantom and cylindrical phantom using GE DSTe PET/CT system. The emission data were acquired for 10 min using phantoms after injecting 44.03 MBq of $^{18}F-FDG$. The CT images for attenuation map were acquired by changing tube current from 10 mA to 95 mA with fixed exposure time of 8 sec and fixed tube voltage of 140 kVp. The PET images were reconstructed using these CT attenuation maps. Image quality of CT images was evaluated by measuring SD (standard deviation) of cylindrical phantom which was filled with water and $^{18}F-FDG$ solution. The PET images were evaluated by measuring the activity ratio between gray matter and white matter in Hoffman phantom images. SDs of CT images decrease by increasing tube current. When PET images were reconstructed using CT attenuation maps with various tube currents, the activity ratios between gray matter and white matter of PET images were almost same. These results indicated that the quality of the PET images using low dose CT data were comparable to the PET images using general dose CT data. Therefore, the use of low dose CT is recommended than the use of general dose CT, when the diagnostic high quality CT is not required. Further studies may need to be performed for other system, since this study is limited to the GE DSTe system used in this study.

  • PDF

Injection of a Denser Fluid into a Rotating Cylindrical Container Filled with Homogeneous Lighter Fluid (균질의 회전유체에 고밀도유체 주입실험)

  • 나정열;황병준
    • 한국해양학회지
    • /
    • v.30 no.4
    • /
    • pp.355-364
    • /
    • 1995
  • A heavy fluid is injected to a rotating cylindrical container of flat or inclined bottom filled with homogeneous lighter fluid. Continuous flow-in and spreading patterns over the bottom of the container are observed and at the same time upper-layer motions induced by the movement of the heavy fluid are traced by thymol blue solution. Regardless of bottom geometry, the injected denser fluid is deflected toward "western wall" and continuous its path along the boundary with radial spreading which occurs in the bottom boundary layer to make a quite asymmetric flow. When the bottom contains a slope(${\beta}$-plane), increased pressure gradient causes the fluid move faster to produce a stronger Coriolis force. This makes the width of the flow narrower than that of f-plane. But, when the denser flow reaches the southern part of the container, a local-depth of denser fluid increases (much greater than the Ekman-layer depth) such that the spreading velocity along the wall is reduced and the interfacial slope increases to make the upper-layer adjust geographically to have oppositely directed upper-layer motion along the interfacial boundary. The role of the denser fluid in terms of vorticity generation in the upper-layer is such that it produces local topographic effect over the western half of the container and also induces vortex-tube stretching which is especially dominant in the f-plane.

  • PDF