• 제목/요약/키워드: Cyclic Loading Test

검색결과 811건 처리시간 0.026초

THE ASSESSMENT OF ABUTMENT SCREW STABILITY BETWEEN THE EXTERNAL AND INTERNAL HEXAGONAL JOINT UNDER CYCLIC LOADING

  • Lee, Tae-Sik;Han, Jung-Suk;Yang, Jae-Ho;Lee, Jae-Bong;Kim, Sung-Hun
    • 대한치과보철학회지
    • /
    • 제46권6호
    • /
    • pp.561-568
    • /
    • 2008
  • STATEMENT OF PROBLEM: Currently, many implant systems are developed and divided into two types according to their joint connection: external or internal connection. Regardless of the connection type, screw loosening is the biggest problem in implant-supported restoration. PURPOSE: The purpose of this study is to assess the difference in stability of abutment screws between the external and internal hexagonal connection types under cyclic loading. MATERIAL AND METHODS: Each of the 15 samples of external implants and internal abutments were tightened to 30 N/cm with a digital torque gauge, and cemented with a hemispherical metal cap. Each unit was then mounted in a $30^{\circ}$ inclined jig. Then each group was divided into 2 sub-groups based on different periods of cyclic loading with the loading machine (30 N/ cm - 300 N/cm,14 Hz: first group $1{\times}10^6$, $5{\times}10^6$ cyclic loading; second group $3{\times}10^6$, $3{\times}10^6$ for a total cyclic loading of $6{\times}10^6$) The removal torque value of the screw before and after cyclic loading was checked. SPSS statistical software for Windows was used for statistical analysis. Group means were calculated and compared by ANOVA, independent t-test, and paired t-test with ${\alpha}$=0.05. RESULTS: In the external hexagonal connection, the difference between the removal torque value of the abutment screw before loading, the value after $1{\tims}10^6$ cyclic loading, and the value after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading was not significant. The difference between the removal torque value after $3{\times}10^6$ cyclic loading and after $3{\times}10^6$, and additional $3{\times}10^6$ cyclic loading was not significant. In the internal hexagonal connection, the difference between the removal torque value before loading and the value after $1{\times}10^6$ cyclic loading was not significant, but the value after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading was reduced and the difference was significant (P < .05). In addition, in the internal hexagonal connection, the difference between the removal torque value after $3{\times}10^6$ cyclic loading and the value after $3{\times}10^6$, and additional $3{\times}10^6$ cyclic loading was not significant. CONCLUSION: The external hexagonal connection was more stable than the internal hexagonal connection after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading (t = 10.834, P < .001). There was no significant difference between the two systems after $3{\times}10^6$, and additional $3{\times}10^6$ cycles.

이축방향 교번반복하중을 받는 구형 철근콘크리트교각의 거동특성 시험 (Bi-Axial Alternate Cyclic Loading Test of Rectangular Reinforced Concrete Columns)

  • 김재관;김익현;이재호;김남식
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.323-328
    • /
    • 2001
  • The behavior of bridge column under multi-directional loading as well as uni-directional loading need to be studied because bridge columns will be subjected to the multi-directional cyclic loading during a strong earthquake. To evaluate the capacity of columns, uni-axial cyclic loading tests and bi-axial alternate cyclic loading tests were carried out. The number of cycles of alternate bi-axial loading were determined considering the ratio of natural frequencies in two orthogonal directions. From the test results, strength degradation and ductility reduction were observed in biaxial loading conditions. Their rates were found to be more rapid in the loading pattern that was determined considering the different natural frequencies.

  • PDF

Shear strength behaviour of coral gravelly sand subjected to monotonic and cyclic loading

  • Vu, Anh-Tuan
    • Geomechanics and Engineering
    • /
    • 제25권2호
    • /
    • pp.89-98
    • /
    • 2021
  • The paper presents an experimental study on the strength behaviour of a coral gravelly sand from Vietnam subjected to monotonic and cyclic loading. A series of direct shear tests were carried out to investigate the shear strength behaviour and the factors affecting the shear strength of the sand such as relative density, cyclic load, amplitude of the cyclic load and loading rate. The study results indicate that the shear strength parameters of the coral gravelly sand include not only internal friction angle but also apparent cohesion. These parameters vary with the relative density, cyclic load, the amplitude of the cyclic load and loading rate. The shear strength increases with the increase of the relative density. The shear strength increases after subjecting to cyclic loading. The amplitude of the cyclic load affects the shear strength of coral gravelly sand, the shear strength increases as the amplitude of the cyclic load increases. The loading rate has insignificantly effect on the shear strength of the coral gravelly sand.

정지토압계수 측정에 관한 연구 II (A Study on Measuring the Coefficient of Earth Pressure at Rest II)

  • 송무효
    • 한국해양공학회지
    • /
    • 제18권6호
    • /
    • pp.58-69
    • /
    • 2004
  • In order to investigate the characteristics of the lateral earth pressure at rest, under hysteretic $K_o-loading/unloading$ conditions, seven types of multi-cyclic models have been studied, using dry sand. For this study, the new type of $K_o-oedometer$ apparatus was developed, and the horizontal pressure was accurately measured. The multi-cyclic models consist of primarily 3 cases: (i) $K_o-test$ under the same loading / unloading condition, (ii) multi-cyclic loading / unloading $K_o-test$ exceeding the maximum pre-vertical stress, and (iii) multi-cyclic loading / unloading $K_o-test$ within the maximum pre-vertical stress. Results fromthe multi-cyclic model indicated that a single-cyclic model could be extended if the exponents for the unloading condition $(\alpha\;and\;\alpha^*)$ and the reloading coefficients $(m_r,\;and\;m_r^{\ast})$ were primarily dependent upon the type of model, number of cycles, and the relative density.

외부긴장 CFRP판용 정착부의 반복하중 실험 (Cyclic Loading Test of Anchorage System for Externally Prestressed CFRP Plate)

  • 정우태;박종섭;박영환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.262-265
    • /
    • 2006
  • This paper presents results on static and cyclic loading tests of anchorage system for externally prestressed CFRP plate. A total of 6 specimens have been tested. The specimens can be classified into the concrete surface specimens and the concrete near surface mounted specimens. Static test results before and after cyclic loading test reveal that anchorage system for externally prestressed CFRP plate has static capacity more than CFRP tensile strength.

  • PDF

Experimental study on the fatigue performance of aluminum foam sandwich with 304 stainless steel face-sheet

  • Yan, Chang;Jing, Chuanhe;Song, Xuding
    • Steel and Composite Structures
    • /
    • 제39권3호
    • /
    • pp.229-241
    • /
    • 2021
  • This work focused on aluminum foam sandwich (AFS) with different foam core densities and different face-sheet thicknesses subjected to constant amplitude three-point bending cyclic loading to study its fatigue performance. The experiments were conducted out by a high frequency fatigue test machine named GPS-100. The experimental results showed that the fatigue life of AFS decreased with the increasing loading level and the structure was sensitive to cyclic loading, especially when the loading level was under 20%. S-N curves of nine groups of AFS specimens were obtained and the fatigue life of AFS followed three-parameter lognormal distribution well. AFS under low cyclic loading showed pronounced cyclic hardening and the static strength after fatigue test increased. For the same loading level, effects of foam core density and face-sheet thickness on the fatigue life of AFS structure were trade-off and for the same loading value, the fatigue life of AFS increased with aluminum foam core density or face-sheet thickness monotonously. Core shear was the main failure mode in the present study.

SM490 TMC 강재의 반복소성모델의 정식화 및 유한요소해석 (Formulation of Cyclic Plasticity Model and FE Analysis for SM490 TMC)

  • 장갑철;장경호
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 가을 학술발표회 논문집
    • /
    • pp.84-89
    • /
    • 2004
  • In this paper, cyclic plasticity model of SM490 TMC was formulated by basing on monotonic loading test and cyclic loading test. For exact description of cyclic performance and plastic deformation capacity of steel member using SM490 TMC, formulated cyclic plasticity model and finite deformation theory were applied to 3-dimensional elastic-plastic FE analysis. Cyclic plastic behavior of pipe-section steel column using SM490 TMC was clarified by carrying out numerical analysis. Also, in order to clarifying seismic performance of pipe-section steel column using SM490 TMC, analysis results were compared with analysis results of pipe-section steel column using SM490. A comparison of analysis results shows that SM490 TMC pipe-section steel column has a better cyclic performance for strength and energy dissipation than SM490 pipe-section steel column under cyclic loading

  • PDF

Single piles under cyclic lateral loads - Full scale tests and numerical modelling

  • Hocine Haouari;Ali Bouafia
    • Geomechanics and Engineering
    • /
    • 제32권1호
    • /
    • pp.21-34
    • /
    • 2023
  • In order to analyze the effect of the cyclic lateral loading on the response of a pile-soil system, a full-scale single steel pile was subjected to one-way cyclic loading. The test pile was driven into a bi-layered soil consisting of a normally consolidated saturated clay overlying a silty sandy layer, the site being submerged by water up to one meter above the mudline in order to reproduce the conditions of an offshore pile foundation. The aim of this paper is to present the main results of interpretation of the cyclic lateral tests in terms of pile deflections, bending moment, and cyclic P-Y curves. From these latter an absolute secant reaction modulus EAS,N was derived and a simple calculation model of the test single pile is proposed based on this modulus. Two applications of the proposed model are carried out, one with a 2D finite element modelling, and the second with a load transfer curves-based method.

점성토의 진동삼축시험시 대변형률영역에서의 주파수 의존성 (Frequency Dependence in Large Strain Range During Cyclic Triaxial Tests of Clay)

  • 김용성
    • 한국농공학회논문집
    • /
    • 제48권5호
    • /
    • pp.63-71
    • /
    • 2006
  • In the present study, the dynamic deformation characteristics of clay, including the effect of loading rate in large strain ranges, were examined by performing undrained cyclic triaxial test. The test results showed that the loading rate to failure decreased with increasing loading amplitude and decreasing loading frequency. While the stress-strain relationships was not affected by loading frequency, excess pore pressure was affected significantly with the change in loading frequency. The change for 0.1 Hz was larger for than that of 0.01 Hz, resulting in inclined effective stress paths. Furthermore, the lower the frequency was, the higher the excess pore pressure was in the first loading.

$K_o$-재하/제하에 의한 건조모래의 거동(II): 다주기 시험 (Behaviour of Dry Sand under $K_o$-Loading / Unloading Conditions(II) : Hysteretic Test)

  • 정성교;정진교
    • 한국지반공학회지:지반
    • /
    • 제11권1호
    • /
    • pp.23-40
    • /
    • 1995
  • 다주기 Ko-재하/제하 시에 수평응력의 변화특성을 관찰하기 위하여 7종류의 시험모형을 선 정하였고, Ko조건을 크게 만족할 수 있도록 특별히 고안한압밀링 형태의 Ko-시험기를 제작하여 실내 건조된 모래에 대하여 실험을 수행하였다. 시험모형은 동일한 재하/제하 응력의 반복, 최대선행응력을 초과하는 반복 재하/제하, 그리고 최대선행 연직응력 내의 반복 재하/제하 Ko시험으로 구분된다. 실험결과에서 다주기 이력모형도 역시 기존의 단주기 이력모형을 확대하여 사용할 수 있음을 보였다. 여기서, 제하시의 지수 (a 및 a*)와 재재하 시의 계수(mr 및 mr*)는 응력이력의 형태, 반복회수 및 상대밀도에 따라 주로 지배되었다.

  • PDF