• 제목/요약/키워드: Cycle ratio

검색결과 1,570건 처리시간 0.022초

정기교체 및 최소수리를 고려한 작업주기 횟수 최적화 (Optimal Working Cycles for Minimal Repair Policy)

  • 이진표
    • 품질경영학회지
    • /
    • 제48권1호
    • /
    • pp.201-214
    • /
    • 2020
  • Purpose: The purpose of this paper is to determine an optimal number of cycle times for the replacement under the circumstance where the system is replaced at the periodic time and the multiple number of working cycles whichever occurs first and the system is minimally repaired between the replacements if it fails. Methods: The system is replaced at periodic time () or cycle time, whichever occurs first, and is repaired minimally when it fails between successive replacements. To determine the optimal number of cycle times, the expected total cost rate is optimized with respect to the number of cycle times, where the expected total cost rate is defined as the ratio of the expected total cost between replacements to the expected time between replacements. Results: In this paper, we conduct a sensitivity analysis to find the following results. First, when the expected number of failures per unit time increases, the optimal number of cycle times decreases. Second, when the periodic time for replacement becomes longer, the optimal number of cycle times decreases. Third, when the expected value for exponential distribution of the cycle time increases, the optimal number of cycle times increases. Conclusion: A mathematical model is suggested to find the optimal number of cycle times and numerical examples are provided through the sensitivity analysis on the model parameters to see the patterns for changes of the optimal number of cycle times.

Numerical Study of Important Factors for a Vortex Shedder using Automated Design Cycle

  • Nyein, Su Myat;Xu, He
    • International Journal of Fluid Machinery and Systems
    • /
    • 제8권3호
    • /
    • pp.124-131
    • /
    • 2015
  • The good performance of a vortex shedder is defined by strong and stable vortex generated under the condition of most linearity in Strouhal number and low power loss. In this paper, the flow past a bluff body of circular cylinder with a slit normal to the flow has been analyzed focusing on drag coefficient, linearity of Strouhal number and flow resistance (K-factor). The ANSYS/FLUENT package is used for flow simulation and the integration method of computational code to iSIGHT platform is employed for automated design cycle. This study results the design with (0.20~0.267) blockage ratio and 0.10 slit ratio as the best shedder for vortex flowmeter and this results are in well agreement with the experiment. As the combination of GAMBIT, FLUENT, and iSIGHT substitutes the design parameters automatically according to the input data, this method designs effectively the vortex shedder with less design cycle time and low manufacturing cost eliminating the human intervention bottleneck.

$\mu$-processor를 이용한 폐쇄사이클 디젤추진시스템의 모니터링 및 제어모델에 관한 연구 (A Study of Monitoring and Control Model of Closed Cycle Diesel Propulsion System using Microprocessor)

  • 유춘식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권6호
    • /
    • pp.894-905
    • /
    • 2004
  • The closed cycle diesel propulsion system is free from the problem of the intake air, exhaust gas and their control that are associated with the conventional diesel propulsion system. The system is composed of a main engine, an exhaust cooler. a $CO_2$ scrubber and a $O_2$ mixer. In this paper, a hardware using microprocessor is proposed in order to monitor and control the oxygen and ratio of specific heat for underwater diesel propulsion system. Also simulation is carried out to ascertain the performance of proposed system.

제습냉방시스템에서 요소성능이 시스템성능에 미치는 영향 (Effects of Individual Components on the System Performance in a Desiccant Cooling System)

  • 장영수;이대영
    • 설비공학논문집
    • /
    • 제19권10호
    • /
    • pp.687-694
    • /
    • 2007
  • Cycle simulation is peformed for two types of the desiccant cooling system incorporating a regenerative evaporative cooler. The cooling capacity and COP are evaluated at various effectiveness values of the regenerative evaporative cooler, the desiccant rotor and the sensible heat exchanger. As either of the effectiveness of the regenerative evaporative cooler or the humidity effectiveness of the desiccant rotor increases, both the cooling capacity and COP increase, but the enthalpy leak ratio gives the opposite effect on the system performance. It is found that COP of cycle A mainly depends on the humidity effectiveness of the desiccant rotor, while for cycle B enthalpy leak ratio of desiccant rotor has the major impact on COP. The effect of the sensible heat exchanger on the cooling capacity is small about 1/10 compared with those of other components.

R1234yf와 R134a 냉매의 이젝터를 적용한 냉동사이클 성능에 대한 해석적 연구 (A Numerical Study on the Performance of a Vapor Compression Cycle Equipped with an Ejector Using Refrigerants R1234yf and R134a)

  • 조홍현;박차식
    • 설비공학논문집
    • /
    • 제27권7호
    • /
    • pp.362-368
    • /
    • 2015
  • This paper presents a numerical study on the performance of a vapor compression cycle equipped with an ejector as an expansion device to improve the COP by reducing the expansion loss and compressor work. The simulation is carried out using a model based on the conservation of mass, energy and momentum in the ejector. From the results of the simulation, the vapor compression cycle equipped with an ejector showed a maximum COP improvement of 14.0% when using R134a refrigerant and 16.8% when using R1234yf. In addition, the performance of the system with an ejector represents the increased performance as the temperature difference between condensing and evaporating increased.

G91강 저주파 피로균열 성장에 미치는 온도와 응력비의 영향 (Effects of Temperature and Stress Ratio on Low-Cycle Fatigue Crack Growth of G91 Steel)

  • 김종범;황수경;김범준;이종훈;박창규;이형연;김문기;임병수
    • 대한금속재료학회지
    • /
    • 제50권4호
    • /
    • pp.271-279
    • /
    • 2012
  • 9-12% Cr steels have been used in thermal power plants which repeat start and stop operations. Major factors of fatigue life are temperature, frequency, stress ratio, holding time, microstructure, and environment. Normally, fatigue life decreases at high temperature, low frequency, high stress ratio, and long holding time conditions. A Mod.9Cr-1Mo steel, called G91, was developed at ORNL (Oak Ridge National Laboratory, USA) and was adopted as a high-temperature structural material in the ASME Code in 2004. However, its low-cycle fatigue and fatigue crack growth characteristics have been rarely studied. In this work, we have investigated the low-cycle fatigue crack growth behaviors of G91 steel under various test conditions in terms of temperature and stress ratio. As temperature and stress ratio increase, the crack growth rate becomes faster and striation distance also increases. On the other hand, the number of branch cracks decreases.

저온 지열발전의 출력 극대화를 위한 흡수식 동력 사이클의 시뮬레이션 (Simulation of an Absorption Power Cycle for Maximizing the Power Output of Low-Temperature Geothermal Power Generation)

  • 백영진;김민성;장기창;이영수;윤형기
    • 대한기계학회논문집B
    • /
    • 제34권2호
    • /
    • pp.145-151
    • /
    • 2010
  • 본 연구에서는 지열발전 등과 같은 저온 열원을 에너지원으로 하는 발전에 응용될 수 있는 흡수식 동력 사이클의 출력 최적화를 수행하였다. 이를 위해 정상상태 사이클 시뮬레이션을 수행하여 사이클의 성능을 고찰하였다. 시뮬레이션은 열원과 열침의 입구온도 및 유량을 고정한 상태에서 수행하였으며, 일반적인 발전소의 열원-열침 유량비를 고려하였다. 사이클의 성능은 두 개의 독립변수를 이용하여 나타내었는데, 이는 분리기 입구 암모니아 농도와 터빈 입구 압력이다. 시뮬레이션 결과, $100^{\circ}C$의 지열수와 $20^{\circ}C$의 냉각수(지열수 유량의 5배) 조건에서, 흡수식 동력 사이클을 이용하면 지열수 유량 1 kg/s 당 최대 약 14 kW의 출력을 얻을 수 있음을 보였다.

Duty Cycle 기반의 WSN MAC을 위한 트래픽 환경에 따른 가변 Wakeup Period 기법 제안 (A Study of Variable Wakeup Period for Duty Cycled MAC protocol in WSN)

  • 이재호;엄두섭
    • 전자공학회논문지
    • /
    • 제49권12호
    • /
    • pp.45-55
    • /
    • 2012
  • 센서 네트워크는 센서가 설치된 지역에서 감지된 데이터를 무선으로 전달하는 기술로서, 기존 방식과 달리 에너지 효율이 매우 중요한 성능요소이다. 이러한 특성에 따라 많은 WSN MAC 프로토콜에서는 Wakeup과 Sleep을 반복하여 수행하는 Duty Cycle 기법을 활용하고 있지만, 고정적인 Wakeup 구간의 설정에 따라 획일화된 에너지 성능과 수신 성공률로 인하여 성능이 제한적이다. 본 논문에서는 이러한 Duty Cycle 기반의 MAC 프로토콜을 개선하기 위하여, 채널 환경에 따라 동적으로 Wakeup 구간을 가변화시키는 기법을 제안한다. 제안하는 방식은 트래픽이 높은 환경에서 Wakeup 구간을 증가시켜 수신 성공률을 높이고, 트래픽이 낮은 환경에서 Wakeup 구간을 줄여 에너지 성능을 향상시켰다. 또한 본 논문에서는 제안하는 방식의 성능에 대한 효율적인 평가를 위하여 기존 동기식 및 비동기식 MAC의 결과와 제안방식을 적용한 MAC의 결과를 비교하고 이를 분석하였다.

증기-액 이젝터를 적용한 R134a 냉동사이클의 성능 비교 (Performance comparison of refrigeration cycle using R134a with the vapor-liquid ejector)

  • 윤정인;김청래;손창효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권9호
    • /
    • pp.890-894
    • /
    • 2015
  • 최근 기본 냉동사이클에 이젝터를 적용한 고효율 냉동사이클의 개발에 대한 연구가 활발히 진행 중이다. 이러한 이젝터는 그 적용 위치에 따라 이젝터의 역할 뿐만 아니라 냉동사이클의 성능도 달라진다. 따라서 본 연구에서는 이젝터 적용 위치가 다른 세 가지 냉동사이클을 선정하고, 각 사이클의 성능을 비교 및 분석하였다. 그 결과, 모든 이젝터 적용 냉동사이클의 COP가 기본 냉동사이클에 비해 최대 44% 향상되었다. 특히 본 연구에서 제안하는 이젝터 냉동사이클의 COP가 3.47로 가장 높게 나타났다. 그리고, 기본 냉동사이클과 비교하여 Bergander 사이클, Xing 사이클, 그리고 본 연구에서 제안한 이젝터 냉동사이클의 응축열량이 최대 21% 감소하였다. 따라서, 본 연구로부터 이젝터 적용 냉동사이클에서 이젝터의 압력비, 토출부 건도, 압축비 등은 냉동장치의 성능 향상에 영향을 미치는 중요한 요소이므로 이들에 대한 최적 제어가 대단히 중요하다.

이젝터를 적용한 냉동사이클의 냉매종류별 성능특성 (Performance Characteristics of Refrigeration Cycles with Ejector using Refrigerants)

  • 윤정인;김청래;손창효
    • 동력기계공학회지
    • /
    • 제21권1호
    • /
    • pp.24-29
    • /
    • 2017
  • Studies in liquid-vapor ejector, which performs a great efficiency in refrigeration cycle is highly concerned. This paper is based on basic refrigeration cycle and three ejector refrigeration cycles and the comparison and contrasts about when 6 different refrigerants are applied to such refrigeration cycles. All cycles had a percentage increase of COP from 4 to 74% when ejector was applied, and the source of increasement was the decrease of total work done due to ejector's pressure recovery function. When R-245fa is applied to cycle (d), results showed that COP was the most superior in such cycle, R-245fa showed high volume entrainment ratio in all cycles. Future studies in refrigeration cycles will require more knowledge and experiments on ejector's appliance to refrigeration cycles and the actuation of such functions.