• Title/Summary/Keyword: Cycle Simulation

Search Result 1,644, Processing Time 0.024 seconds

An Analysis on the Cycle Time of a Symmetric Poling System with Nonexhaustive Service (비고갈 서비스 하에서의 대칭적 폴링시스템의 순환시간에 대한 분석)

  • 이명용;강석호
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.17 no.1
    • /
    • pp.77-84
    • /
    • 1992
  • Queueing models with service can be applied in the area of performance studies of polling systems in data communication and switching systems. We provide a new approach for analysis on the cycle time of the multiqueue system consisting of statistically identical stations where at most one message is served for any station in a polling cycle. We assume an independent Posson arrival at each station. The message service time and switchover time are assumed to be constant. Based on the dependence between the stations, cycle time distribution is derived. Then, this result is validated by a computer simulation.

  • PDF

A Study on the Optimal Design of JIT Kanban System under Uncertain Environment (불확실한 환경하에서의 JIT 간판 시스템 최적설계에 관한 연구)

  • 김용범;김우열
    • Journal of the military operations research society of Korea
    • /
    • v.24 no.1
    • /
    • pp.176-188
    • /
    • 1998
  • In this paper, it is identified that the optimal level of each performance measures (service and inventory level) is not sensitive to an uncertain environment under JIT Kanban system designed by Moeeni. Moreover, it is proposed that the optimal design method considering multiple performance characteristics is the optimal level decision method according to the relative importance differences of each performance when there exist multiple performance characteristics. The result from the simulation analysis shows that the number of Kanban for stage 3 (final process) and stage 2 is increased at the service level. It is found that the expected loss is minimal when the cycle time decreases and the container size increases. However, the stage 1 is not affected by the number and cycle time of Kanban. It is thus important to consider carefully the cycle time and the container size of the Kanban to satisfy the demand in right time. In case of inventory level, the working inventory level decreases when the container size is decreased and the working inventory level also decreases slightly when the cycle time of the Kankban is increased in stage 1 and 2.

  • PDF

Performance and Parameter Comparison between single stage and Two-Stage Compression/Absorption Heat Pump System (단단 및 2단 압축/흡수 히트펌스시스템의 성능 및 중요인자비교 분석)

  • Tian, Huaizhang;Park, Seong-Ryong
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.451-456
    • /
    • 2005
  • The mathematical model for the heat exchangers of absorber and desorber is made in the elementary control volume method and the thermodynamic properties of working fluid. water/ammonia mixture. are calculated by some fundamental subroutines in RefProp 7.0 and flash subroutines made by authors The simulation results show that two-stage cycle has higher COP than single stage if temperature lift is high: the performance of single stage compression cycle can be improved by increase of absorber pressure. but the performance of two-stage compression cycle can not be improved in this way : the compressor discharging temperature of two-stage compression is much lower than that of single stage cycle. which is very important to the safety operation of CA heat pump. Major parameter comparison between the cycles at their optimal configurations is also given.

  • PDF

Real Time Traffic Signal Plan using Neural Network

  • Choi Myeong-Bok;Hong You-Sik
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.5 no.4
    • /
    • pp.360-366
    • /
    • 2005
  • In the past, when there were few vehicles on the road, the T.O.D.(Time of Day) traffic signal worked very well. The T.O.D. signal operates on a preset signal cycling which cycles on the basis of the average number of average passenger cars in the memory device of an electric signal unit. Now days, with increasing many vehicles on restricted roads, the conventional traffic light creates startup-delay time and end-lag-time. The conventional traffic light loses the function of optimal cycle. And so, $30-45\%$ of conventional traffic cycle is not matched to the present traffic cycle. In this paper we proposes electro sensitive traffic light using fuzzy look up table method which will reduce the average vehicle waiting time and improve average vehicle speed. Computer simulation results prove that reducing the average vehicle waiting time which proposed considering passing vehicle length for optimal traffic cycle is better than fixed signal method which doesn't consider vehicle length.

Optimal Traffic Information using Fuzzy Neural Network

  • Hong, You-Sik;Lee, Choul--Ki
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.3 no.1
    • /
    • pp.105-111
    • /
    • 2003
  • This paper is researching the storing of 40 different kinds of conditions. Such as, car speed, delay in starting time and the volume of cars in traffic. Through the use of a central nervous networking system or AI, using 10 different intersecting roads. We will improve the green traffic light. And allow more cars to easily flow through the intersections. Now days, with increasing many vehicles on restricted roads, the conventional traffic light creates prove startup-delay time and end-lag-time. The conventional traffic light loses the function of optimal cycle. And so, 30-45% of conventional traffic cycle is not matched to the present traffic cycle. In this paper proposes electro sensitive traffic light using fuzzy look up table method which will reduce the average vehicle waiting time and improve average vehicle speed. Computer simulation results prove that reducing the average vehicle waiting time which proposed considering passing vehicle length for optimal traffic cycle is better than fixed signal method which dosen't consider vehicle length.

A study on the energy efficient operation of economizer cycle control (외기냉방제어의 효율적인 운영에 관한 연구)

  • Lee, H.W.;Leigh, S.B.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.545-551
    • /
    • 1997
  • As the cooling energy requirement in an office building increases due to the increased internal heat gains, the effort to minimize the energy consumption through efficient operation of existing HVAC systems will be beneficial. In this study, one of the energy conserving efforts in an office building, operational strategies of Economizer Cycle Control have been investigated through DOE-2.1E computer simulation. The findings can be summarized : 1) Economizer Cycle Control saves energy throughout the year, 2) Econo-Limit-T must be applied seasonally based on the outside and return air conditions, 3) use of Enthalpy control is more energy efficient than that of Temperature control.

  • PDF

Adaptive current-steering analog duty cycle corrector with digital duty error detection (디지털 감지기를 통해 전류 특성을 조절하는 아날로그 듀티 사이클 보정 회로)

  • Choi, Hyun-Su;Kim, Chan-Kyung;Kong, Bai-Sun;Jun, Young-Hyun
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.465-466
    • /
    • 2006
  • In this paper, novel analog duty cycle corrector (DCC) with a digital duty error detector is proposed. The digital duty error detector measures the duty error of the clock and converts it into a digital code. This digital code is then used to accurately correct the duty ratio by adaptively steering the charge-pump current. The proposed duty cycle corrector was implemented using an 80nm DRAM process with 1.8V supply voltage. The simulation result shows that the proposed duty cycle corrector improves the settling time up to $70{\sim}80%$ at 500MHz clock frequency for the same duty correction accuracy as the conventional analog DCC.

  • PDF

Soft-Switching Half-Bridge Converter using Secondary Switches for Output Control and Conduction Loss Reduction (출력제어와 도통손실 감소를 위해 2차측 스위치를 사용한 소프트스위칭 하프브리지 컨버터)

  • 김영필;김진우;김태웅;이성백
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.103-106
    • /
    • 2001
  • In this paper, a soft switching half-bridge converter using secondary switches for output control and conduction loss reduction is proposed. The conventional half-bridge converter must be fixed on duty cycle for soft switching. The proposed converter was consisted of two added switches in series of the secondary rectifier diodes. The main switches with constant duty cycle are operated ZVS. The secondary switches are operated ZV-ZCS. Especially, the primary switches were fixed duty cycle for maximum voltage conversion ratio. Output of converter is controlled by duty cycle or phase-shifted time of secondary switches. The conduction loss of the proposed converter can be reduced by the secondary switches. The operation characteristic, analysis, simulation and experimental results of the proposed converter are presented.

  • PDF

Development and Validation of Hourly Based Sim-CYCLE Fine in a Temperate C3//C4 Coexisting Grassland

  • Lee, G.Z.;Lee, P.Z.;Kim, W.S;Oikawa, T.
    • The Korean Journal of Ecology
    • /
    • v.28 no.6
    • /
    • pp.353-363
    • /
    • 2005
  • We developed a local-scale ecophysiological model, Sim-CYCLE Fine by modifying Sim-CYCLE which was developed for a global scale simulation. Sim-CYCLE fine is able to simulate not only carbon fluxes but also plant growth with various time-steps from an hour to a month. The model outputs of $CO_2$ flux and biomass/LAI were highly reliable; we validated the model results with measurements from the eddy covariance technique and the harvest method ($R^2$ values of around 0.9 for both). The results suggested that the phonology and the seasonal dynamics of the $C_3/C4$ plant communities affected significantly the carbon fluxes and the plant growth during the plant growing season.

Modelling of a High Efficiency Refrigeration System with Heat Storage for Reverse Cycle Hot Gas Defrost

  • Ardiyansyah, Ardiyansyah;Choi, Kwang-Il;Oh, Jong-Taek;Oh, Hoo-Kyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.15 no.4
    • /
    • pp.175-181
    • /
    • 2007
  • A computer model of a high efficiency refrigeration system equipped with heat storage for reverse cycle-hot gas defrost (the stored heat is used during defrost cycle of the system) is presented. The model was developed based on both theoretical and empirical equations for the compressor, evaporator, condenser and the heat storage equipment. Simulations of the prototype system were carried out to investigate refrigeration system performance under various operating conditions during refrigeration cycles. The simulations of the evaporator during defrost cycles at 30 and $40^{\circ}C$ hot gas refrigerant temperature were also performed which resulted on shorter defrost time but only slight increase in defrost efficiency. These information on energy efficiency and the defrost time required are important in order to avoid excessive parasitic load and temperature rise of the refrigerated room.