• Title/Summary/Keyword: Cutting instruments

Search Result 40, Processing Time 0.022 seconds

A study on evaluation of roundness characteristics about precise machined parts (정밀가공 부품의 진원도 특성 평가에 관한 연구)

  • Oh SangLok;Lee Gab-jo;Kim Jong-Kwan
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.209-215
    • /
    • 2005
  • The dimensions and forms of precise machined parts are different to kinds of machine. It will be variant according to machine wear, tool form, cutting method and cutting condition at the same machine. At that time, the most important things are controlled and measured by appropriate measuring instruments. This paper aims to contribute to improving measurement accuracy through evaluation and consideration about various roundness in the machining company.

  • PDF

Effect of Feedrate and Specimen Shape on Cutting Force and Surface Roughness of Ultrasonic Dental Surgical Instrument (치과용 초음파 수술기의 이송속도 및 시편형상이 절삭반력과 표면거칠기에 미치는 영향)

  • Sang Ho Kim;Seung Han Yang;Joong Ho Lee;Jong Kyun Choi
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.2
    • /
    • pp.109-117
    • /
    • 2023
  • In this study, the effect of the shape of the specimen and the feedrate of the dental ultrasonic surgical instrument on the cutting force and surface roughness of the specimen is analyzed. Experimental specimens were made of SAWBONES artificial bone materials in square and spherical specimens. In addition, the cutting feedrate of the surgical instrument was controlled through the developed moving system. The cutting force generated when cutting the specimen was measured through a force sensor. After the experiment, the cutting surface of the specimen was observed through a three-dimensional optical microscope and the surface roughness was measured. Through one-way ANOVA, the effect of each specimen shape and feed rate on surface roughness was analyzed. As a result of the experiment, the cutting force increased proportionally in the initial feed rate increase stage, but the increase in cutting force decreased as the feed rate continued to increase. Also, the cutting force showed a difference according to the shape of the specimen. The spherical specimen with a relatively small cutting surface area had less cutting force than the square specimen. However, as a result of one-way ANOVA, it was found that the specimen shape and feed rate did not affect the surface roughness. In future studies, it is expected to be used for comparative analysis of ultrasonic surgical instruments and correlation analysis between cutting factors.

Evaluation of the wear of the periodontal curet's cutting edge (치주 큐렛의 절단 연 마모도 평가)

  • Park, Eung-Joon;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.3
    • /
    • pp.575-584
    • /
    • 1997
  • The quality of periodontal instrument cutting edge is a basic element of effective root planing procedure. Using instruments, the sharp edge is changed into blunt or beveled edge. With the blunt instrument, the periodontal treatment can't be carried into accuracy and effective. The study on the wear of periodontal curet is insufficient, there are few publications about the change of sharpness of cutting egde after using instrument and a certen reports were published on the study of scanning electron microscope(SEM) examination. In this study, to declare the number of strokes for sharpening of instruments, the changes of cutting edge is measured by the clinical methods, tactile sensitivity examination and refraction light-white line test after scaling strokes and root planing strokes. SEM test was added for defined the changes of cutting edges. The 7/8 Gracey curets that have been never used was tested. Maxillary molars which were extracted from the School of Dental Medicine, Dankook University was used. Subjected teeth had attachment loss more than 6 mm in bucca-lingual surface and sufficient calculus of a band type in cervical area. The strokes of curet were executed 3, 5, 7, 9, 11, 13 times on scaling stroke and 10, 15, 20, 25, 30, 35 times on root planing stroke. A resident has periodontal experience over 3 years carried out the clinical examinations those tactile sensitivity examination and refraction light-white line test 5 times. The case there being tactile sensitivity certenly is 2, the case being felt tactile sensitivity is 1, and the case there not being tactile sensitivity is 0. The visual examination was recorded as following. The case that refracted white line is not recognised is 2, the case that uncerten is 1, and the case that acknowledged is 0. The results were obtained as follows. 1. After scaling strokes, the tactile sensitivity was reduced after 11 strokes and disappeared in 13 strokes. 2. In tactile sensitivity after root planing procedures, sensitivity was reduced after 25 strokes and disappeared in 35 strokes. 3. In case of visual examination, the detection of refracted white line was increased after 9 strokes of scaling procedures and the accuracy of wear wasn't showed after root planing procedures. 4. In SEM, metal projection was observed on new periodontal curet cutting edge and it was disappeared after scaling procedures. 5. In SEM, the cutting edge was showed changing linear into an aspect of the surface after 5 strokes of scaling procedures and 10 strokes of root planing procedures and showed beveled edge in 11 strokes of scaling procedures, 25 strokes of root planing procedures. The results of 3-type examination indicated that the sharpening of curet should be performed after 11 strokes of scaling procedures and 25 strokes of root planing procedures.

  • PDF

EFFICIENCY OF DENTIN CUTTING AND ROOT -END RETROCAVITY PREPARATION USING ULTRASONIC DIAMOND INSTRUMENTS AND THEIR INFLUENCE ON TOOTH STRUCTURE (초음파 다이아몬드 기구의 상아질 삭제 효과, 치근단 역충전 와동 형성효율 및 치질에의 영향)

  • Lim, Choon-Hee;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.54-67
    • /
    • 1998
  • The purposes of this study were to evaluate the efficiency of dentin cutting and root-end cavity preparation, and to determine the incidence of tooth crack when root-end retrograde cavity preparation was done with. ultrasonic diamond instruments. To evaluate the efficiency of dentin cutting, ultrasonic diamond and stainless steel instruments were applied to 20 exposed bovine dentin surfaces perpendicularly or parallely at the low, and medium power settings for 1 minute ($Miniendo^{TM}$, EIE, CA, U.S.A.). The resultant cavity depth was measured. To evaluate the efficiency of cavity preparation and to investigate the incidence of tooth crack, 165 mesiobuccal, distobuccal and palatal root-ends of extracted human maxillary first molars were resected by 3 mm perpendicularly to the long axis of tooth using a slow speed diamond saw after root canal preparation and filling. Retrocavities were prepared using a ultrasonic diamond instrument or a stainless steel one of the low- or medium power settings of 2 or 6. Time consumed and the number of strokes used for the cavity preparation were measured and the incidence of tooth cracks was evaluated under a stereomicroscope. The results were as follows: Both at the low and medium power settings, and both with perpendicularly- and parallely applied tips to dentin, diamond instruments showed higher dentin cutting efficiency than stainless steel ones did (p<0.01). When tips were applied to dentin perpendicularly, both diamond instrument and stainless steel one showed higher cutting efficiency with medium power setting than with low power one (p<0.01). Both at the low- and medium power settings, both diamond instrument and stainless steel one showed higher cutting efficiency when tips were applied perpendicularly to dentin surface than applied parallely (p<0.01). At the medium power setting, the number of stroke and time consumed were less with diamond instrument than with stainless steel one (p<0.05) for the retrograde cavity preparation. At the low power setting, diamond instrument induced less tooth cracks than stainless steel one did (p<0.01).

  • PDF

Robotics for Advanced Therapeutic Colonoscopy

  • Wong, Jennie YY;Ho, Khek Yu
    • Clinical Endoscopy
    • /
    • v.51 no.6
    • /
    • pp.552-557
    • /
    • 2018
  • Although colonoscopy was originally a diagnostic imaging procedure, it has now expanded to include an increasing range of therapeutic interventions. These procedures require precise maneuvers of instruments, execution of force, efficient transmission of force from the operator to the point of application, and sufficient dexterity in the mobilization of endoscopic surgical instruments. The conventional endoscope is not designed to support technically demanding endoscopic procedures. In case of colonoscopy, the tortuous anatomy of the colon makes inserting, moving, and orientating the endoscope difficult. Exerting excessive pressure can cause looping of the endoscope, pain to the patient, and even perforation of the colon. To mitigate the technical constraints, numerous technically enhanced systems have been developed to enable better control of instruments and precise delivery of force in the execution of surgical tasks such as apposing, grasping, traction, counter-traction, and cutting of tissues. Among the recent developments are highly dexterous robotic master and slave systems, computer-assisted or robotically enhanced conventional endoscopes, and autonomously driven locomotion devices that can effortlessly traverse the colon. Developments in endoscopic instrumentations have overcome technical barriers and opened new horizons for further advancements in therapeutic interventions. This review describes examples of some of these systems in the context of their applications to advanced therapeutic colonoscopy.

Development and Performance of Cutting and Crushing Instrument of Hair to Prevent Blocking U-trap in Home Drainage System (하수구 막힘 방지를 위한 모발 절단 분쇄 장치 개발 및 성능평가)

  • Kim, Donhue
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.6
    • /
    • pp.394-399
    • /
    • 2013
  • The recalcitrant hairs which are accumulated in the U-trap equipped to prevent the stench from the drainage produce the phenomenon of blocking the flow of water through the home drainage pathway. The chemical dissolution solutions commercially manufactured are excessively poured into U-trap to solve this blocking problem. In this study, the specially designed instrument was developed for the experiments to cut and crush the hairs of which main component are the recalcitrant keratin proteins. The performance of the instrument for cutting and crushing hairs was investigated using experimental methods. The cutting and weighing method was used in order to obtain the average length of a large amount of hairs cut by instrument. This method is relatively simple to measure the weight of cutting hairs to obtain the average length of the fibers, the values of average length showed not greater tolerances. Also the average cutting number was defined to evaluate the performance of the cutting and crushing instruments designed for this study. We were able to apply these evaluation methods to provide the criteria to obtain the optimal structure of instrument and proper operation time in the given experimental conditions. These experimental methods and results will provide the good example to design and to analyze the various device that can be used for cutting the fibers. The cutting and crushing instrument developed in this study showed the effective abilities to cutting the hairs. The general using the cuttting and crushing instrument at every home would be helpful to prevent water environmental pollution.

EFFECT OF MICROLEAKAGE OF A SELF-ETCHING PRIMER ADHESIVE ACCORDING TO TYPES OF CUTTING INSTRUMENTS (삭제기구가 자가 산부식 접착제의 미세누출에 미치는 영향)

  • Kim, Yong-Hee;Park, Jae-Gu;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.327-334
    • /
    • 2007
  • The purpose of this study was to evaluate the effect of burs on microleakage of Class V resin restorations when a self-etching primer adhesive was used. Forty Class V cavities were prepared with four different cutting burs on extracted third molars, and divided into one of four equal groups (n = 10); Group 1-plain cut carbide bur (no. 245), Group 2-cross cut carbide bur (no. 557), Group 3-fine diamond bur (TF-21F), Group 4-standard diamond bur (EX-41). The occlusal and gingival margin of cavities was located in enamel and dentin, respectively. Cavities were treated with Clearfil SE Bond and restored with Clearfil AP-X. Specimens were thermocycled, immersed in a 2% methylene blue solution for 24 hours, and bisected longitudinally. They were observed leakages at enamel and dentinal margins. Data were analyzed using Mann-Whitney and Wilcoxon signed ranked test. The results of this study were as follows; 1. At enamel margin, microleakage of group 4 was statistically higher than those of group 1, 2 and 3 (p < 0.01). 2. At dentinal margin, microleakage of group 4 was statistically higher than group 3 (p < 0.01), but group 1 and 2 were not statistically different with group 3 and 4. 3. Enamel microleakage was statistically higher than dentinal microleakage in group 1, 2 and 3 (p < 0.05), but statistical difference between the microleakage of enamel and dentinal margin was not in Group 4. In conclusion, the use of coarse diamond bur showed high microleakage at both enamel and dentinal margin when Clearfil SE Bond was used in class V cavity.

Preference of undergraduate students after first experience on nickel-titanium endodontic instruments

  • Kwak, Sang Won;Cheung, Gary Shun-Pan;Ha, Jung-Hong;Kim, Sung Kyo;Lee, Hyojin;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.3
    • /
    • pp.176-181
    • /
    • 2016
  • Objectives: This study aimed to compare two nickel-titanium systems (rotary vs. reciprocating) for their acceptance by undergraduate students who experienced nickel-titanium (NiTi) instruments for the first time. Materials and Methods: Eighty-one sophomore dental students were first taught on manual root canal preparation with stainless-steel files. After that, they were instructed on the use of ProTaper Universal system (PTU, Dentsply Maillefer), then the WaveOne (WO, Dentsply Maillefer). They practiced with each system on 2 extracted molars, before using those files to shape the buccal or mesial canals of additional first molars. A questionnaire was completed after using each file system, seeking students' perception about 'Ease of use', 'Flexibility', 'Cutting-efficiency', 'Screwing-effect', 'Feeling-safety', and 'Instrumentation-time' of the NiTi files, relative to stainless-steel instrumentation, on a 5-point Likert-type scale. They were also requested to indicate their preference between the two systems. Data was compared between groups using t-test, and with Chi-square test for correlation of each perception value with the preferred choice (p = 0.05). Results: Among the 81 students, 55 indicated their preferred file system as WO and 22 as PTU. All scores were greater than 4 (better) for both systems, compared with stainless-steel files, except for 'Screwing-effect' for PTU. The scores for WO in the categories of 'Flexibility', 'Screwing-effect', and 'Feeling-safety' were significantly higher scores than those of PTU. A significant association between the 'Screwing-effect' and students' preference for WO was observed. Conclusions: Novice operators preferred nickel-titanium instruments to stainless-steel, and majority of them opted for reciprocating file instead of continuous rotating system.

Validation of Instruments to Classify the Frailty of the Elderly in Community (지역사회 거주 노인의 허약선별도구 타당도 평가)

  • Lee, In-Sook;Park, Young-Im;Park, Eun-Ok;Lee, Soon-Hee;Jeong, Ihn-Sook
    • Research in Community and Public Health Nursing
    • /
    • v.22 no.3
    • /
    • pp.302-314
    • /
    • 2011
  • Purpose: This study aimed to validate instruments to classify the frailty of Korean elderly people in community. Methods: For this study, 632 elders were selected from community-based elderly houses and home visiting registries, and data on frailty were collected using three instruments during November, 2008. The Korean Frail Scale (KFS) was composed of 10 domains with the maximum score of 20. The Edmonton Frail Scale (EFS) had 10 domains with the maximum score of 17. The 25_Japan Frail Scale (25_JFS) was composed of 6 domains with the maximum score of 25. Internal consistency was measured with Cronbach's ${\alpha}$. Sensitivity, specificity and area under the curve (AUC) of ROC were measured to see validity with long.term care insurance grade as a gold standard. Results: The Cronbach's ${\alpha}$ was .72 for KFS, .55 for EFS, and .80 for 25_JFS. Sensitivity, specificity, and AUC were 70.0%, 83.2%, and .83, respectively, at cutting point 10.5 for the KFS, 50.0%, 80.9%, and .66, respectively, at 8.5 for EFS, and 80.0%, 85.9%, and .86, respectively, at 12.5 for 25_JFS. Conclusion: KFS and three JFS showed favorable internal consistency and predictive validity. Further longitudinal studies are recommended to confirm predictive validity.

A Study on the Differentiation of Women with Perimenstrual Symptom Severity and Perimenstrual Distress Patterns (월경 전후기 증상 정도 및 월경고통 유형 판별요인)

  • Park, Young-Joo;Ryu, Ho-Shin
    • Women's Health Nursing
    • /
    • v.4 no.1
    • /
    • pp.123-138
    • /
    • 1998
  • The purpose of this study was to describe perimenstrual symptom severity levels and perimenstrual distress patterns of women. The study performed the discriminant analysis in which included seven factors : age, pariety, social support, menstrual socialization(mother's symptom, sister's symptom, and menstrual effect), attitude of sex role and depression. The subjects were 283 women that they were not pregnant or lactating, had at least one period in past three months, would understand the purpose of study and willingly accepted the participation. The data analysis was done by pc-SAS program after data collection from Nov. 20, 1997 to Dec. 18, 1997. The descriptive analysis was done to explore general characteristics of the subjects and the stepwise discriminant analysis was done to verify factors in relation to perimenstrual symptom severity levels(severe vs mild menstrual symptom group) and perimenstrual distress patterns(spasmodic vs congestive menstrual symptom group). The instruments were selected for this study from Interpersonal Support Evaluation List(ISEL) by Cohen and Hoberman(1983), Center for Epidemic Studies Depression(CES-D) by Radloff(1977), and Sex Role Attitude Scale by Yunok Suh(1995), Mother's symptom and sister's symptom measurements by Woods, Mitchell & Lentz(1995), and menstrual effect by Brooks-Gun & Ruble(1980). The major findings of this study are as follows : 1. Of the 283 women, 93 women(32.9%) were assessed to severe perimenstrual symptom group and 190 women(67.1%) were assessed to mild perimenstrual symptom group. Results from the stepwise discriminant analysis showed three factors, such as depression, menstrual effect, and age, significantly related to perimenstrual symptom severity and they explained 20% of the total variance. The linear discriminant equation included three factors related to perimenstrual symptom groups was showed(Z=1.445 depression+0.174 menstrual effect-0.054 age). The cutting score(Z) was 2.809. We classified the severe perimenstrual symptom group by more than the cutting score 2.809 and the mild perimenstrual symptom by less or equal than the cutting score 2.809. The correctedness of posterior probability from discriminant equation was 72% as two perimenstrual symptom group classifications. 2. Of the 264 women, 139 women(52.7%) were assessed to spasmodic perimenstrual distress group and women(47.3%) were assessed to congestive perimenstrual distress group. Results from the stepwise discriminant analysis showed two factors, such as depression, age, significantly related to perimenstrual distress groups and they explained 8% of the total variance. The linear discriminant equation included two factors related to perimenstrual distress group was showed(Z=-0.084 age-0.776 depression). The cutting score(Z) was -3.759. We classified the spasmodic perimenstrual distress group by more than cutting score -3.759 and the congestive perimenstrual distress group by less or equal than cutting score -3.759. The correctedness of posterior probability from discriminant equation was 65% as two perimenstrual distress group classifications.

  • PDF