• Title/Summary/Keyword: Customized implant

Search Result 96, Processing Time 0.027 seconds

Comparison of fit accuracy and torque maintenance of zirconia and titanium abutments for internal tri-channel and external-hex implant connections

  • Siadat, Hakimeh;Beyabanaki, Elaheh;Mousavi, Niloufar;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.271-277
    • /
    • 2017
  • PURPOSE. This in vitro study aimed to evaluate the effect of implant connection design (external vs. internal) on the fit discrepancy and torque loss of zirconia and titanium abutments. MATERIALS AND METHODS. Two regular platform dental implants, one with external connection ($Br{\aa}nemark$, Nobel Biocare AB) and the other with internal connection (Noble Replace, Nobel Biocare AB), were selected. Seven titanium and seven customized zirconia abutments were used for each connection design. Measurements of geometry, marginal discrepancy, and rotational freedom were done using video measuring machine. To measure the torque loss, each abutment was torqued to 35 Ncm and then opened by means of a digital torque wrench. Data were analyzed with two-way ANOVA and t-test at ${\alpha}=0.05$ of significance. RESULTS. There were significant differences in the geometrical measurements and rotational freedom between abutments of two connection groups (P<.001). Also, the results showed significant differences between titanium abutments of internal and external connection implants in terms of rotational freedom (P<.001). Not only customized internal abutments but also customized external abutments did not have the exact geometry of prefabricated abutments (P<.001). However, neither connection type (P=.15) nor abutment material (P=.38) affected torque loss. CONCLUSION. Abutments with internal connection showed less rotational freedom. However, better marginal fit was observed in externally connected abutments. Also, customized abutments with either connection could not duplicate the exact geometry of their corresponding prefabricated abutment. However, neither abutment connection nor material affected torque loss values.

Clinical case of implant restoration using customized healing abutment (맞춤형 치유 지대주를 이용한 임플란트 수복 증례)

  • Park, Jung-Wan;Hong, Min-Ho;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.222-227
    • /
    • 2015
  • Aesthetic impression is emphasized in the recent field of implant restoration. However, there is limitation of creating proper shape of soft tissue as well as cervical emergence profile due to the use of pre-existing healing abutment in the process of initial post-operative soft tissue healing period. Designing the shape of abutment into the final customized abutment instead of its original shape helped to achieve more aesthetic implant restoration by applying healing abutment which could minimize the malposition and recession of soft tissue. In this study, soft tissue healing was promoted using the post-operative customized healing abutment and thereby obtained the result of more aesthetic and functional restoration by minimizing displacement of soft tissue in the process of applying final customized abutment.

Reconstruction of upper anterior by implant using customized zirconia abutment and all ceramics: a clinical report (맞춤형 지르코니아 지대주와 완전도재관을 이용한 상악 전치부 임플란트 보철 수복)

  • Kim, Ja-Yeong;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.81-92
    • /
    • 2014
  • It is so hard to obtain optimal anterior esthetics in the implant prosthesis. This is not only because of hard and soft tissue problem such as alveolar bone resorption and interdental papilla loss but also because of prosthetic limitation related to marginal exposure of metal abutment and metal ceramics and low transillumination. In this case, guided soft tissue healing is obtained using a long term provisional restoration with soft and hard tissue augmentation or immediate implantation. Then, this healed tissue is transferred to final master model using a customized impression coping and the implant is restored with a customized zirconia abutment and a all ceramics. This case presents satisfying result esthetically and functionally.

Maxillary anterior single implant prosthesis ; a clinical case

  • Kim Seung-June;Kwon Kung-Rock;Lee Sung-Bok;Woo Yi-Hyung;Choi Dae-Gyun;Choi Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.3
    • /
    • pp.306-312
    • /
    • 2001
  • Achieving an aesthetic implant-supported restoration in the single tooth missing case can be challenging when the implant site is in e anterior region. The objective of this report is to focus on presurgical evaluation of implant site and systematic development of related prosthetic modalities. An accurate diagnostic evaluation, a systematically developed pesurgical plan, and knowledge and clinical skill of the various related therapeutic modalities are indispensible. Collection of patient's information, appropriate abutment selection, soft tissue contour, implant axis, and occlusion need to be discussed for aesthetic clinical outcome. For aesthetic restoration, such as surgical guide stent for precise implant positioning customized provisional restoration for development of optimal periimplant soft tissue contours, and fabrication customized abutment (mesiostructure) for veriable emergence profile, are recommended.

  • PDF

Considerations and clinical appliances of various abutments in implant prostheses (임플란트 보철 치료에서 지대주 선택시 고려사항과 임상적 적용)

  • Park, Sungwoo;Kim, Sunjai;Chang, Jae-Seung
    • The Journal of the Korean dental association
    • /
    • v.54 no.3
    • /
    • pp.191-197
    • /
    • 2016
  • In the past, restoration of implant crown, ready-made abutment produced by implant manufacturer could only be used. Using straight, angled abutment, there was a limit in adaptation multiple implants. Recently, with the development of implant and CAD/CAM technology, CAD/CAM customized abutment use has become possible which is different from the past when restoration was possible with only prefabricated abutment. Not only it makes emergence profile possible which is similar to natural teeth, but also it makes insertion path possible on CAD in multiple implant restorations. However, on anterior teeth which dental esthetics is very important, another restorations which are formed with natural colored gingiva area could be required. Titanium-based zirconia prostheses which have titanium connection and zirconia structure from 1mm above fixture platform are alternative. Therefore, the purpose of this review is to analyze the characteristics, advantages and disadvantages of the abutment which is used in multiple implant restorations, and to choose right abutment when clinical trials.

  • PDF

Rehabilitation of edentulous maxilla with implant-supported milled bar overdenture using CAD/CAM customized abutment: A case report (CAD/CAM 맞춤형 지대주를 이용한 milled-bar 피개의치 증례)

  • Ji, Woon;Chang, Jae-Seung;Kwon, Joo-Hyun;Kim, Sunjai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.146-151
    • /
    • 2016
  • In patients with fully edentulous maxilla, fabrication of implant-supported overdenture can be a viable treatment option, when a minimum of six implants were strategically placed. Among several attachment systems used for implant-supported overdentures, milled-bars prevent rotational movement of denture, thus showing great stability, and have the advantage of splinting multiple implants with each other. In this case report, a milled-bar supported overdenture was fabricated for a patient suffering from condition of fully edentulous maxilla with severe ridge resorption in the anterior residual ridge. Seven implants composed of three different systems were effectively utilized by CAD/CAM customized abutment and cement-retained milled bar.

Radiographic evaluation of computer aided design/computer aided manufacturing (CAD/CAM) customized abutment of implant (CAD/CAM으로 제작된 임플란트 맞춤형 지대주의 방사선학적 평가)

  • Yun, Tae-Gyeong;Lee, Gyeong-Je;Chung, Chae-Heon;Kim, Hee-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.258-263
    • /
    • 2017
  • Purpose: In this study, the retrospective radiographic study is executed to evaluate amount of bone loss of various conditions in patients using customized abutment for 4 years of follow-up. Materials and methods: The subjects of this study were implant fixed dental prosthesis using CAD/CAM customized abutments. CAD/CAM customized abutment and fixed dental prosthesis were manufactured by the Prosthodontics Department of Chosun University Dental Hospital from August 1, 2011 to July 31, 2012. Radiological assessments were performed on the patients who were treated by the fixed prosthodontics. After each treatment, a retrospective study was performed for a total of 4 years at 3 months, 6 months, 1 year, 2 years, 3 years, and 4 years. Results: As a result of the study, the customized abutment using CAD/CAM showed less bone loss than the results of existing research. There was no statistically significant differences at alveolar bone loss between splinting group and non-splinting group (respectively 0.27 mm, 0.5 mm). Also, there were statistically significant differences at alveolar bone loss in mx. anterior, mx. posterior, mn. anterior and mn. posterior part (respectively 1.37 mm, 0.39 mm, 0.00 mm, 0.30 mm). Conclusion: The customized abutment using CAD/CAM showed less bone loss than the results of existing research, there were statistically significant differences at alveolar bone loss in implant positions.

Clinical accuracy of impression technique using digital superimposition of customized abutment with subgingival margin: A case report (치은연하 변연을 가지는 맞춤형 지대주에서 디지털 중첩기술을 이용한 인상채득술의 임상 적용 증례)

  • Kim, Jin-Wan;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Lee, Hyeonjong;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.2
    • /
    • pp.169-175
    • /
    • 2020
  • Traditionally, gingival retraction has been performed to obtain customized abutment impressions with subgingival margins of the implant supported prosthesis. However, gingival retraction may have side effects such as gingival recession and bleed, leading to an inaccurate impression. In order to prevent these problems, in this case, the new technique has been introduced; a customized abutment which is designed for superimposition is used. Before the connection of the abutment to the implant fixture, pre-scanned shape data are stored, and then the optical impression without gingival retraction is obtained after connecting to the fixture. The suprastructure is fabricated by superimposing the two data. This technique showed the clinical efficacy of fabricating the implant supported prosthesis with subgingival margin, which satisfied the aesthetics, convenience, and clinically acceptable marginal and internal fit.

Esthetic reconstruction of upper central incisor using immediate Frialit-2 implant placement, immediate temporary crown fabrication and IPS Empress 2 crown (즉시 Frialit-2 implant 식립, 즉시 임시치관 제작 그리고 IPS Empress 2 crown을 이용한 상악중절치의 심미적 수복)

  • Kim, Yu-Lee;Oh, Sang-Chun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.1
    • /
    • pp.43-48
    • /
    • 2003
  • During the past several years, significant advances have occurred in the utilization of osseointegrated implants for the treatment of partially edentulous patients. One of the biggest purposes for treating of these patients is the high demand for improved esthetics, especially in the anterior region. For this esthetics, the new trend in dental implants is the immediate placement and immediate superstructure fabrication. The refined surgical technique, the skillful soft tissue management, and the proper prosthetic coordination are the main factors to achieve natural looking of implant supported prosthesis. The customized provisional restoration and the customized impression coping are recommended for the optimal peri-implant soft tissue contour. The basic concept of Frialit 2 system was the immediate replacement of a tooth with root-analog fixture after extraction. This system guarantees an ideal result in function and esthetics. The ceramic abutment system offers improved quality in the respect of esthetics, fitness, translucency, and biocompatibility. In this clinical report, the final restoration made with IPS Empress 2 crown on the CeraBase abutmen of Frialit 2 system allowed the reproduction of the natural vitality of tooth and adjacent gingiva.

Comparison of removal torque between prefabricated and customized abutment screw (기성품과 맞춤형 임플란트 지대주 나사의 풀림 토크 비교)

  • Jamiyandorj, Otgonbold;Kim, Jee-Hwan;Kim, Mu-Seong;Park, Young-Bum;Shim, June-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.243-248
    • /
    • 2012
  • Purpose: The purpose of this study is to compare the removal torque between prefabricated and customized implant abutment screw. Materials and methods: Three types of implant system (Osstem, Astra, Zimmer) were used. For each system, prefabricated abutment screw (control group) and customized abutment screw (test group) were used to connect the fixture and the abutment (n = 6). Digital torque gauze was used to control the tightening torque and the screws were tightened under each manufacturer's recommendation. 10 minutes after the connection the same tightening torque was applied, and 5 minutes after the second connection, the removal torque was measured. This procedure was repeated 10 times. In the cyclic loading test, 10 minutes after the first connection to the 6 groups (n = 3), the same tightening torque was applied, and a total of 1,000,000 time loading was applied at 30 degree angle to long axis with 50 N load. Repeated measures of ANOVA test (${\alpha}$=.05) was used as statistics to evaluate the effect of repeated loading number on the removal torque. Independent t-test was used to evaluate the difference in removal torque after cyclic loading. Results: The removal torque significantly decreased as the number of loading repetition increased (P<.05). In the 10 time repetition test, there was no significant difference between the prefabricated and customized implant abutment screw of the 3 implant system (P<.05). Also in the cyclic loading test, there was no significant difference between the prefabricated and customized implant abutment screw of the 3 implant system (P<.05). Conclusion: Within the limitation of this study, there was no significant difference in the removal torque between the prefabricated abutment screw and customized abutment screws.