• Title/Summary/Keyword: Curve measurement

Search Result 991, Processing Time 0.05 seconds

A Correlation Between Vertical Fixation Disparity and Stereopsis at Near (근거리에서 수직주시시차와 입체시와의 관계)

  • Yoon, Min-Hwa
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.321-327
    • /
    • 2013
  • Purpose: To investigate a correlation between vertical fixation disparity and stereopsis by analyzing distribution of types of vertical fixation disparity. Methods: In this study, RANDOT(R) stereotest partly using random dot was used in stereopsis tests. The vertical fixation disparity in close proximity categorized fixation disparity slope into six types on the basis of the result of measurement in when two thin lines, one for one eye looks, become overlapped as a line by adding into prism with Wesson fixation disparity card while maintaining a distance of 25 cm from patients. Results: In the types of near vertical fixation disparity curve, targeting 43 people, the first type 55.82% was the most distributed, the second type is the least 23.25%, the third type of 4.65%, the fourth type of 4.65%, the fifth type of 6.98%, the sixths types of 4.65% were distributed. The result of a correlation analysis, which shows the degree of linear correlation between two variables, represented that stereopsis is not correlated with Y-intercept (r = -0.07) which show vertical fixation disparity, associated phoria (r = -0.03) and dissociated phoria (r = -0.00), but it was not statistically significant (p>0.05). Fixation disparity slope of vertical fixation disparity (r = 0.36) was shown to have a positive correlation with stereopsis. It has a low positive correlation and a meaningful statistics (p<0.05). The Y-intercept which indicates vertical fixation disparity was also not associated with stereopsis (r = -0.07) and dissociated phoria (r = -0.03), and this was not statistically significant (p>0.05), while it had a high correlation as well as a statistically significant with associated phoria (r = 0.89). There was a negative correlation between Y-intercept and fixation disparity slope of vertical fixation disparity (r = -0.33). It showed a low relationship but statistically valuable (p>0.05). As a result of regression analysis, the stereopsis was changed as 7.631" if vertical fixation disparity changes 1' and the vertical fixation disparity changed as 0.017' if stereopsis changes 1', and the change was statistically significant (p<0.05). Conclusions: The study shows that there is a low correlation between stereopsis and vertical fixation disparity, and it is difficult to determine stereopsis only using vertical fixation disparity. Therefore, it suggests other factors above vertical fixation disparity have greater influence on stereopsis.

Analysis of Correlation with Cross Sectional Area of Flow and Flow Rate Variation of Discharge Measurement Point in the Upper Stream of Seomjin River (섬진강상류 유량측정지점의 유수단면적과 유량변화에 따른 상관관계 분석)

  • Song, KwangDuck;Kim, KapSoon;Lee, DongJin;Ham, SangIn;Kim, DaeYoung;Oh, TaeYoun;Lee, JaeChoon;Lim, ByungJin
    • Korean Journal of Ecology and Environment
    • /
    • v.46 no.1
    • /
    • pp.94-102
    • /
    • 2013
  • This study was carried out to determine the variation of the water level and crosssection area for investigating changes of stream foreland, and to determine the correlation between the average flow velocity and cross-section area so as to understand the hydrological characteristics of the stream. The slope of the cross-sectional area was changed in water levels of 0.6~1.0 m and 1.8~2.0 m. The first change occurred in the low-water level season, and the second change occurred in the high-water level seasons. It is assumed that the changes occurred due to the geological transfigure. The correlation between the cross-sectional area and the average flow velocity was 0.22~0.86 in the exponential equation and 0.20~0.87 in the linear equation. The low water level had a higher correlation than the high water level, and free weirs in the upper stream showed a very low correlation. Therefore, this study provides novel information for the management of water quality in the riverside, using correlation equations of the water level and flow velocity with the cross section area.

A study on optical coherence tomography system using optical fiber (광섬유를 이용한 광영상 단층촬영기에 관한연구)

  • 양승국;박양하;장원석;오상기;김현덕;김기문
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.5-9
    • /
    • 2004
  • In this paper, we studied the OCT(Optical Coherence Tomography) system which it has been extensively studied because of having some advantages such as high resolution cross-sectional images, low cost, and small size configuration. A basic principle of OCT system is Michelson interferometer. The characteristics of light source determine the resolution and the transmission depth. As a results, the light source have a commercial SLD with a central wavelength of 1,285 nm and FWHM(Full Width at Half Maximum) of 35.3 nm. The optical delay line part is necessary to equal of the optical path length with scattered light or reflected light from sample. In order to equal the optical path length, the stage which is attached to reference mirror is moved linearly by step motor And the interferometer is configured with the Michelson interferometer using single mod fiber, the scanner can be focused of the sample by using the reference arm. Also, the 2-dimensional cross-sectional images were measured with scanning the transverse direction of the sample by using step motor. After detecting the internal signal of lateral direction at a paint of sample, scanner is moved to obtain the cross-sectional image of 2-demensional by using step motor. Photodiode has been used which has high detection sensitivity, excellent noise characteristic, and dynamic range from 800 nm to 1,700 nm. It is detected mixed small signal between noise and interference signal with high frequency After filtering and amplifying this signal, only envelope curve of interference signal is detected. And then, cross-sectional image is shown through converting this signal into digitalized signal using A/D converter. The resolution of the OCT system is about 30$\mu\textrm{m}$ which corresponds to the theoretical resolution. Also, the cross-sectional image of ping-pong ball is measured. The OCT system is configured with Michelson interferometer which has a low contrast because of reducing the power of feedback interference light. Such a problem is overcomed by using the improved inteferometer. Also, in order to obtain the cross-sectional image within a short time, it is necessary to reduce the measurement time for improving the optical delay line.

  • PDF

Quantitative determination of inosine 5'-monophosphate dehydrogenase activity in human peripheral blood mononuclear cells by ion-pair reversed-phase high-performance liquid chromatography (이온쌍 역상 HPLC를 이용한 인체 말초혈액단핵구에서 이노신 5'-일인산 탈수소효소 활성의 정량적 측정)

  • Shin, Hye-Jin;Kwon, Soon-Ho;Park, Ji-Myeong;Kwon, Soon-Hyo;Lee, Kyoung-Ryul;Kim, Young-Jin;Lee, Sang-Hoo
    • Analytical Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.531-536
    • /
    • 2010
  • A quantitative analytical method has been established for the measurement of inosine 5'-monophosphate dehydrogenase (IMPDH) activity in human peripheral blood mononuclear cells (PBMCs) by ion-pair reversed-phase high performance liquid chromatography equipped with ultraviolet detection (HPLC/UV). IMPDH is a ${\beta}$-nicotinamide adenine dinucleotide hydrate (NAD+)-dependent dehydrogenase in which the enzyme converts inosine 5'-monophosphate (IMP) into xanthosine 5'-monophosphate (XMP). Its activity was measured by quantifying a HPLC chromatogram corresponding to XMP produced during the incubation of lysed PBMCs with IMP as a substrate and $NAD^+$ as a coenzyme. XMP produced was detected at a wavelength of 260 nm. The mobile phase was composed of a mixture of 37 mM potassium dihydrogen phosphate containing 7 mM tetra-n-butylammonium hydrogen sulfate adjusted to pH 5.5 and methanol (85:15, v/v) with a flow rate of 1 mL/min. The calibration curve was linear ($r^2$=0.999999) in the range of $0.2-50.0\;{\mu}M$ and the limit of quantification (LOQ) was $0.2\;{\mu}M$. The intra- and inter-day precisions were between 0.88-1.47% and 0.85-5.24%, respectively. The intra- and inter-day accuracies were between 98.74-99.99% and 99.95-101.65%, respectively. IMPDH activity in 11 Korean healthy volunteers ranged from 18.29 to 36.60 nmol/h/mg protein (mean = $27.70{\pm}6.28\;nmol/h/mg$ protein).

Histamine Bronchial Provocation Test -Timed Tidal Breathing Technique- (히스타민 기관지유발 검사 -일정시간 흡입법-)

  • Chung, Yeon-Tae;Won, Kyung-Sook;Park, Hae-Shim
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.3
    • /
    • pp.270-276
    • /
    • 1994
  • Background: The measurement of nonspecific bronchial hyperreactivity is valuable for diagnosis and management of bronchial asthma. Methacholine or histamine is used for the pharmacologic provocation test. Usually a methacholine bronchial provocation test is performed by a dosing technique with counted number of breaths. A dosimeter is indispensable in the dosing technique. Recently a timed tidal breathing technique which dose not need an expensive dosimeter was introduced. We measured the degree of nonspecific bronchial hyperreactivity to histamine using a simple timed tidal breathing technique. Method: Forty two healthy volunteers, 12 patients with bronchial asthma(BA), 10 patients with rhinitis(RH) and 10 patients with upper respiratory infection(URI) participated in the study. The subject's nose was clipped and inhalation continued during tidal breathing for 2 minutes via a face mask. $FEV_1$ was measured at 30 seconds, 90 seconds after inhalation and inhalation of next solution was continued until there was a fall in $FEV_1$ of 20%. Histamine PC20 was defined as the concentration at 20% fall of $FEV_1$ and it was obtained from the log dose-response curve by linear interpolation. Results: Inhalation of serial dilution of histamine could be performed in all patients without significant side effects. The geometric mean${\pm}$standard deviation of histamine PC20 in healthy volunteers is $8.27{\pm}2.22mg/ml$, BA group $0.33{\pm}3.02mg/ml$, RH group $0.85{\pm}3.24mg/ml$, and URI group $1.47{\pm}1.98mg/ml$. Conclusion: Histamine bronchial provocation test using timed tidal breath method is a simple and suitable tool for management of patients with bronchial hyperreactivity.

  • PDF

Experimental and clinical studies with impedance audiometry; the increase in air volume in the middle ear air system and the pneumatization of human temporal bones (측두골의 함기도와 중이강의 용적이 고막 임피던스에 미치는 영향에 관한 연구)

  • 민양기
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1977.06a
    • /
    • pp.4.4-5
    • /
    • 1977
  • The vibratory energy introduced into the external ear canal is changed by the mechanical factors of eardrum itself, the motility of ossicles, and the air cushion of tympanic cavity and the like. This study was designed to investigate the volume of middle ear cavity and mastoid air cell system as a factor of determining the accoustic impedance of middle ear system. The author studied how the increase in air volume of middle ear cavity effects on the acoustic impedance of middle ear system with dogs' ears and researched the correlation between the degree of pneumatization of temporal bones and the acoustic impedance of middle ear system by comparing the radiological findings of pneumatization (Law's and Towne's projection) with the acoustic impedance measurements with Madsen ZO 70. The result is as follows: 1 The tympanometric findings in control state revealed the curves of type A, and did not change in its configuration by the increase in the air volume of dogs middle ear system. 2. The static compliance of middle ear revealed a distinct and linear increase in proportion to the increase in air volume of middle ear system; the rate of increase was $0.05{\pm}0.02$ cc of static compliance per cc of air volume. 3. Authenticated in the above result and the tendency to increase in static compliance in proportion to the increase in the degree of pneumatization of temporal bones, there was significant regression equation between the degree of pneumatization of temporal bones (x variable) and the static compliance of middle ear system; $y=0.19x{\pm}0.16{\pm}0.05$ It is suggested that the difference in volume of middle ear system plays an important role in the change of the static compliance of middle ear, and the author concludes that the measurement of static compliance of middle ear has clinical value as diagnostic means of evaluating the degree of pneumatization of temporal bones along with some radiological examination.

  • PDF

Analysis and Uncertainty Estimation of Zearalenone in Cereal-Based Products by LC-MS/MS (LC-MS/MS를 이용한 곡류가공품의 제랄레논 분석과 측정불확도 추정)

  • Choi, Eun Jung;Kang, Sung Tae;Jung, So Young;Shin, Jae Min;Jang, Min Su;Lee, Sang Me;Kim, Jung Hun;Chae, Young Zoo
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.6
    • /
    • pp.658-665
    • /
    • 2012
  • A survey of zearalenone contamination was conducted on cereal-based products by using an immunoaffinity column with LC-MS/MS. The calibration curve showed good lineality, with correlation coefficients ($R^2$) of 0.999 in the concentration range from 1 to 250 ng/mL. The limits of detection and quantification were approximately $0.3{\mu}g/kg$ and $1.0{\mu}g/kg$, respectively. The recoveries in the barley tea, Misutgaru and snack ranged from 73.6-107.8%. Zearalenone was detected in 10 samples (11.2% incidence). The highest zearalenone contamination level was $29.7{\mu}g/kg$ in the Misutgaru. This survey was conducted with uncertainty of measurement. The expanded uncertainty for zearalenone was estimated to be $44.9{\pm}5.0{\mu}g/kg$ (k=2, 95% confidence level) and $128.7{\pm}7.9{\mu}g/kg$ (k=2, 95% confidence level) for barley tea, $30.7{\pm}5.8{\mu}g/kg$ (k=2, 95% confidence level) and $173.7{\pm}14.9{\mu}g/kg$ (k=2.26, 95% confidence level) for Misutgaru, and $37.2{\pm}7.4{\mu}g/kg$ (k=2.31, 95% confidence level) and $151.0{\pm}10.4{\mu}g/kg$ (k=2, 95% confidence level) snack at the level of $41.7{\mu}g/kg$ and $166.7{\mu}g/kg$, respectively.

PREPARATION OF AMORPHOUS CARBON NITRIDE FILMS AND DLC FILMS BY SHIELDED ARC ION PLATING AND THEIR TRIBOLOGICAL PROPERTIES

  • Takai, Osamu
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.3-4
    • /
    • 2000
  • Many researchers are interested in the synthesis and characterization of carbon nitride and diamond-like carbon (DLq because they show excellent mechanical properties such as low friction and high wear resistance and excellent electrical properties such as controllable electical resistivity and good field electron emission. We have deposited amorphous carbon nitride (a-C:N) thin films and DLC thin films by shielded arc ion plating (SAIP) and evaluated the structural and tribological properties. The application of appropriate negative bias on substrates is effective to increase the film hardness and wear resistance. This paper reports on the deposition and tribological OLC films in relation to the substrate bias voltage (Vs). films are compared with those of the OLC films. A high purity sintered graphite target was mounted on a cathode as a carbon source. Nitrogen or argon was introduced into a deposition chamber through each mass flow controller. After the initiation of an arc plasma at 60 A and 1 Pa, the target surface was heated and evaporated by the plasma. Carbon atoms and clusters evaporated from the target were ionized partially and reacted with activated nitrogen species, and a carbon nitride film was deposited onto a Si (100) substrate when we used nitrogen as a reactant gas. The surface of the growing film also reacted with activated nitrogen species. Carbon macropartic1es (0.1 -100 maicro-m) evaporated from the target at the same time were not ionized and did not react fully with nitrogen species. These macroparticles interfered with the formation of the carbon nitride film. Therefore we set a shielding plate made of stainless steel between the target and the substrate to trap the macropartic1es. This shielding method is very effective to prepare smooth a-CN films. We, therefore, call this method "shielded arc ion plating (SAIP)". For the deposition of DLC films we used argon instead of nitrogen. Films of about 150 nm in thickness were deposited onto Si substrates. Their structures, chemical compositions and chemical bonding states were analyzed by using X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy and infrared spectroscopy. Hardness of the films was measured with a nanointender interfaced with an atomic force microscope (AFM). A Berkovich-type diamond tip whose radius was less than 100 nm was used for the measurement. A force-displacement curve of each film was measured at a peak load force of 250 maicro-N. Load, hold and unload times for each indentation were 2.5, 0 and 2.5 s, respectively. Hardness of each film was determined from five force-displacement curves. Wear resistance of the films was analyzed as follows. First, each film surface was scanned with the diamond tip at a constant load force of 20 maicro-N. The tip scanning was repeated 30 times in a 1 urn-square region with 512 lines at a scanning rate of 2 um/ s. After this tip-scanning, the film surface was observed in the AFM mode at a constant force of 5 maicro-N with the same Berkovich-type tip. The hardness of a-CN films was less dependent on Vs. The hardness of the film deposited at Vs=O V in a nitrogen plasma was about 10 GPa and almost similar to that of Si. It slightly increased to 12 - 15 GPa when a bias voltage of -100 - -500 V was applied to the substrate with showing its maximum at Vs=-300 V. The film deposited at Vs=O V was least wear resistant which was consistent with its lowest hardness. The biased films became more wear resistant. Particularly the film deposited at Vs=-300 V showed remarkable wear resistance. Its wear depth was too shallow to be measured with AFM. On the other hand, the DLC film, deposited at Vs=-l00 V in an argon plasma, whose hardness was 35 GPa was obviously worn under the same wear test conditions. The a-C:N films show higher wear resistance than DLC films and are useful for wear resistant coatings on various mechanical and electronic parts.nic parts.

  • PDF

On the Distensibility of the External Carotid Artery of the Rabbit (가토(家兎) 외경동맥(外經動脈)의 신장도(伸張度)에 대(對)하여)

  • Lee, Dong-Il;Choo, Young-Eun
    • The Korean Journal of Physiology
    • /
    • v.7 no.2
    • /
    • pp.49-58
    • /
    • 1973
  • The distensibility of the major arteries has been investigated extensively, but the value expressed as Young Modulus varies widely by the different schools of the investigators, the major reason undoubtedly being the difficulties encountered in the measurement. In the present study, an attempt was made to elucidate the distensibility of the external carotid artery of the rabbit, which was placed in saline immediately after removing from the apparently healthy, normal rabbit without anesthesia. The circular section strip and longitudinal section strip were made from the whole artery, and Young Modulus of the whole artery, circular section and longitudinal section strips was calculated from the length-tension curve of each sample. Also, the similar samples of the artery seperately obtained were placed in ATP solution in the concentration of 0.15 mM and 0.30 mM, and Young Modulus was similary calculated. Experiments were performed at 15,45 and 75 min after the artery was removed from the rabbit, and the results thus obtained are summarized as follows. 1) Young Modulus of the whole external carotid artery of the rabbit in saline was $4.74{\times}10^7dyne/cm^2$ at 15 min, but lower values were obtained at 45 and 75 min, Young Modulus being $4.62{\times}10^7dyne/cm^2\;and\;4.13{\times}10^7dyne/cm^2$, respectively. When the arterial samples were placed in ATP solutions, Young Modulus did not change much throughout the experiment, and lower Young Moduli were obtained in 0.30 mM ATP solution than in 0. 15 mM ATP solution. 2) Young Modulus Of the Circular Section Strip in Saline was $4.11{\times}10^7dyne/Cm^2,\;3.75{\times}10^7dyne/cm^2\;and\;3.90{\times}10^7dyne/cm^2,$ respectively, at 15, 45 and 75 min, the value at 15 min being the highest. However, when the strip was placed in ATP solutions, no appreciable change was observed throughout the experiment, and Young Moduli were lower in 0.30 mM ATP solution than in 0.15 mM ATP solution. 3) Young Modulus of the longitudinal section strip in saline was $2.12{\times}10^7dyne/cm^2,\;2.48{\times}10^7dyne/cm^2\;and\;2.46{\times}10^7dyne/cm^2$, respectively, at 15, 45 and 75 min, Young Modulus being slightly elevated in the latter part of the experiment. A similar tendency was observed when the strip was placed in ATP solutions.

  • PDF

Application of Chlorophyll Fluorescence Parameters for the Detection of Water Stress Ranges in Grafted Watermelon Seedlings (수박접목묘의 건조스트레스 범위 탐지를 위한 엽록소형광 지수의 적용)

  • Shin, Yu Kyeong;Kim, Yong Hyeon;Lee, Jun Gu
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.461-470
    • /
    • 2019
  • This study was carried out to quantify the drought stress in grafted watermelon seedlings non-destructively by using chlorophyll fluorescence (CF) imaging technique rather than the visual judgment. Six-day old watermelon seedlings were grown under uniform irrigation for 3 days, and then given drought stress. Afterward, the sensor for the measurement of water content in plug tray cell unit was used to classify the drought-stress level into nine groups from D1 (53.0%, sufficient moisture state) to D9 (15.7%, extremely dry stress), and the 16 CF parameters were measured. In addition, re-irrigation was performed on the drought stressed seedlings(D5 - D9) to determine the growth and photosynthesis recovery level, which was not confirmed by visual judgment. The kinetic curve patterns of CF in three different drought stressed seedling groups were found to be different for the early detection of drought stress. All the 16 CF parameters decreased continuously with exposure to drought stress and drastically decreased from D5 (32.1%) where the visual judgment was possible. The fluorescence decline ratio (Rfd_Lss) started to decrease from the initial drought stress level (D5 - D6), and the Maximum PSII quantum yield (Fv/Fm) was significantly decreased in the later extreme drought stress range (D7 - D9) by re-irrigation recovery test. Thus, Rfd_Lss and Fv/Fm parameters were finally selected as potent indicators of growth and photosynthesis recovery in the initial and later stages of drought stress. Also, to the differences in the numerical values of the individual chlorophyll fluorescence parameters, the drought stress level was intuitively confirmed through the image. These results indicate that Rfd and Fv/Fm can be considered as potential CF parameters for the detection of low and extremely high drought stress, respectively. Furthermore, Fv/Fm can be considered as the best CF parameters for recovery at re-irrigation.