• 제목/요약/키워드: Curve measurement

검색결과 985건 처리시간 0.028초

입목재적(立木材積) 측정법(測定法)에 관(關)한 연구(硏究) -용재수목(用材樹木)의 재적측정법(材積測定法)을 중심으로 (A study on the method of measurement of the standing-tree volume -Particularly concerning the method of measurement of the timber volume)

  • 이광남
    • 한국산림과학회지
    • /
    • 제3권1호
    • /
    • pp.28-31
    • /
    • 1963
  • Recognizing shortcomings and unreasonable points of the usual methods of measurement of the standing-tree volume, author contrived measurement formula of standing-tree volume which is based on stem-curve equation, $y^2=2px$, resulted from the analysises and experiments on stem-curve by differentiation & integration. The results of this study are as follows ; (1) The following is the formula. $V=1/2g_{1.2}$(h+1.2) V=volume of tree $g_{1.2}$ = sectional area at breast heigh h = height of tree (2) So plain is the form of this formula that this formula is more convenient than usual formulas in measuring. (3) The percentage error of this formula is negative and it is remarkably superior to usual formulas except Pressler's formula, in other words, the higher the tree that is measured is, the more inaccurate become pressler's formula, and the percentage error of the breast-height form factor method is direct proportion to the grossness of the tree that is measured, but the higher the tree that is measured, the lower become percentage error of this formula in geometrical progression.

  • PDF

수소 동위원소 분리를 위한 77 K 극저온 파과 곡선 측정 시스템 제작 (Investigation of Cryogenic Breakthrough Curve Measurement System at 77 K for Hydrogen Isotopologue Separation)

  • 김수환;오현철
    • 한국재료학회지
    • /
    • 제32권1호
    • /
    • pp.36-43
    • /
    • 2022
  • Breakthrough analysis has widely been explored for the dynamic separation of gaseous mixtures in porous materials. In general, breakthrough experiments measure the components of a flowing gas when a gaseous mixture is injected into a column filled with an adsorbent material. In this paper, we report on the design and fabrication of a breakthrough curve measurement device to study the dynamic adsorptive separation of hydrogen isotopologues in porous materials. Using the designed system, an experiment was conducted involving a 1:1 mixture of hydrogen and deuterium passed through a column filled with zeolite 13X (1 g). At room temperature, both hydrogen and deuterium were adsorbed in negligible amounts; however, at a temperature of 77 K, deuterium was preferentially adsorbed over hydrogen. The selectivity was different from that in the existing literature due to the different sample shapes, measurement methods, and column structures, but was at a similar level to that of cryogenic distillation (1.5).

미세부품 영상 측정시 진동에 의한 오차 보상 알고리즘 개발 (Development of Error Compensation Algorithm for Image based Measurement System)

  • 표창률
    • 한국정밀공학회지
    • /
    • 제21권10호
    • /
    • pp.102-108
    • /
    • 2004
  • In this paper, we studied a vibration problem that is critical and common to most precision measurement systems. For micro mechanical part measurements, results obtained from the vision-based precision measurement system may contain errors due to the vibration. In order to defeat this generic problem, for the current study, a PC based image processing technique was used first, to assess the effect of the vibration to the precision measurement and second, to develop an in-situ calibration algorithm that automatically compensate the measurement results in real time. We used a set of stereoscopic CCD cameras to acquire the images for the dimensional measurement and the reference measurement. The mapping function was obtained through the in-situ calibration to compensate the measurement results and the statistical analysis for the actual results is provided in the paper. Based on the current statistical study, it is expected to obtain high precision results for the micro measurement systems.

부화소 정밀도를 가지는 3차원 BGA 검사 알고리즘 (A 3D BGA Inspection Algorithm with Subpixel Accuracy)

  • 김정훈;박성한;심영석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 추계종합학술대회 논문집
    • /
    • pp.507-510
    • /
    • 1999
  • Inspection of BGAs presents several challenges for modem measurement equipment. No only must these systems be fast and accurate, they must deal with the special challenges presented by very small shiny metal spheres. For accurate measurement, we propose an algorithm which fits for estimating the accurate ball height using 2-D curve-fitting algorithm. The real boundary between two adjacent pixels and the real ball diameter are measured with subpixel accuracy Experimental results show that the proposed method calculates the ball height and diameter with subpixel accuracy and is robust in local noise with low measurement error.

  • PDF

단축 인장에 의한 SU-8박막의 기계적 물성 측정 (Measurement of mechanical properties of SU-8 thin film by tensile testing)

  • 백동천;박태상;이순복;이낙규
    • 반도체디스플레이기술학회지
    • /
    • 제3권2호
    • /
    • pp.23-26
    • /
    • 2004
  • Thin film is one of the most general structures used in micro-electro-mechanical systems (MEMS). To measure the mechanical properties of SU-8 film, tensile testing was adopted which offers not only elastic modulus but also yield strength and plastic deformation by load-displacement curve. Tensile testing system was constructed with linear guided servo motor for actuation, load cell for force measurement and dual microscope for strain measurement.

  • PDF

6kW 풍력발전기의 출력곡선 측정 (Power Curve Measurements on the 6kW Wind Turbine)

  • 유능수;남윤수;이정완;조주석
    • 산업기술연구
    • /
    • 제25권B호
    • /
    • pp.149-157
    • /
    • 2005
  • The power performance monitoring system for a small class of wind turbine is established. The wind turbine power performance characteristics are determined by measured power curve and the estimated annual energy production (AEP). The measured power curve is determined by collecting simultaneous measurements of wind speed and power output at the test site under varying wind conditions. In order to determine the power performance characteristics of the wind turbine accurately, the data are of sufficient quantity and quality shall be corrected according to defined criteria. In this study, the 6kW wind turbine made by Germany Inventus GmbH is examined.

  • PDF

대구경 말뚝정재하시험 및 하중전이 측정사례 (Static pile load test and load trasfer measurement for large diameter piles.)

  • 최용규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 말뚝기초 학술발표회
    • /
    • pp.107-141
    • /
    • 2000
  • Large diameter piles can be defined as piles with diameter of at least 0.76 m (2.5 ft). In bridge foundation, large diameter piles have been used as pier foundations and their use has been increased greatly. In this study, static pile load tests for large diameter piles peformed in Kwangan Grande Bridge construction site were introduced. Also, various sensor installation methods for several types of piles (that is, open-ended steel pipe pile, drilled shafts and socketed pipe piles), pipe axial load measuring method, load transfer analysis method and pile load test results (pile-head load - settlement curve, and pile axial load distribution curve along the pile depth) were introduced.

  • PDF

Fan 냉각장치에서 System 저항에 관한 수치해석 (A Numerical Analysis on the System Impedance in a Fan Cooling System)

  • 김동일;복기소;이승규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1424-1429
    • /
    • 2004
  • To seek the fan operating point on a cooling system with fans, it is very important to determine the system impedance and it has been usually examined with the fan tester(wind tunnel) based on ASHRAE standard and AMCA standard. This leads to a large investment in time and cost, because it could not be executed until the system is made actually. Therefore it is necessary to predict the system impedance curve through numerical analysis so that we could reduce the measurement effort. This paper presents how the system impedance curve (pressure drop curve) is computed by CFD in substitute for experiment. In reverse order to the experimental principle of the fan tester, pressure difference was adopted first as inlet and outlet boundary conditions of the system and then flow rate was calculated.

  • PDF

양산천 수위-유량관계 특성에 관한 현장관측 분석 (Analysis of Field Observations on Characteristics of Stage-Discharge Relationshiup for Yangsan River)

  • 이용희;이상배
    • 한국항만학회지
    • /
    • 제14권1호
    • /
    • pp.107-114
    • /
    • 2000
  • Derivation of stage-discharge relationship and characteristics for Yangsan river is presented in this paper. This research has been conducted as the second one after the first trial in 1997. The determination of discharge at a Yangsan river gauging was best made by measuring the flow velocities with a current meter and rod float. The rating curve obtained through 52 stage-discharge measurements on Yangsan river basin in 1999 is represented by Q=15.3540-140.6076H+182.44372H$^2$, which is discovered to be most excellent among other curves in reliability analysis. The observed stage-discharge data for Yangsan river was tested by HEC-RAS program, and reproduction of discharge by the induced curve was investigated and compared with the computational results. The rating curve of Yangsan river shows characteristics of Yangsan river more accurately compared with those separated in terms of water levels.

  • PDF

속이 빈 원통형음극 방전의 전압-전류 곡선에서 음 저항 영역 관찰 (Observation of Negative Resistance Region in Voltage-current Curve of Hollow Cathode Discharge)

  • 이준회;이성직
    • 한국전기전자재료학회논문지
    • /
    • 제18권9호
    • /
    • pp.870-875
    • /
    • 2005
  • We measured the optogalvanic signal and discharge voltage-current(V-I) curve under the two different discharge conditions with different buffer gases, Ar, and Ne. When the Gd was used as a cathode material at low discharge current less than 10mA, a significant change was observed in the current-voltage curve. Time resolved optogalvanic signal measurement were measured by the diode laser of which wavelengths correspond to metastable transition line of these gases (Ar, Ne). From these measurements, we found that the characteristics of the V-I curve strongly depend on the Penning ionization process.