• Title/Summary/Keyword: Curve detection

Search Result 861, Processing Time 0.039 seconds

Vitamin C Quantification of Korean Momordica charantia by Cultivar, Harvest Time, and Maturity (국내산 여주의 지역별, 수확시기별, 숙기별 Vitamin C 함량)

  • Jeong, Yun Sook;Lee, Sang Hoon;Song, Jin;Hwang, Kyung-A;Noh, Geon Min;Hwang, In Guk
    • The Korean Journal of Food And Nutrition
    • /
    • v.29 no.4
    • /
    • pp.474-479
    • /
    • 2016
  • This study aimed to investigate the concentration of vitamin C in Momordica charantia (MC) by cultivar, harvest time, and maturity. The methods for determining vitamin C levels were validated by measuring their linearity, specificity, limit of detection (LOD), limit of quantification (LOQ), precision, and accuracy using HPLC. Results showed high linearity in the calibration curve, with a coefficient of correlation ($R^2$) of 0.9994. The LOD and LOQ values for vitamin C were 0.05 and $0.16{\mu}g/mL$, respectively. The relative standard deviations (RSDs) for intra- and inter-day precision of vitamin C measurements were 2.34 and 1.34%, respectively. Depending on cultivar, the concentration of vitamin C in MC varied from 20.75~107.31 mg/100 g, fresh weight, with an average level $68.85{\pm}25.57mg/100g$, FW. When MC was analyzed by harvest time, the 20150612 MC showed the highest amount of vitamin C ($113.20{\pm}1.89mg/100g$, FW). On the other hand, the highest vitamin C content by maturity was $48.59{\pm}0.87mg/100g$, FW (15 day old MC). This information on the comparative vitamin C levels of MC might be useful to food scientists and should be explored for functional food development.

Significance of Serum Ferritin in Multiple Trauma Patients with Acute Respiratory Distress Syndrome (다발성 외상 환자에서 발생되는 급성 호흡 곤란 증후군의 예측 인자로서 혈청 페리틴의 의의)

  • Ji, Yae-Sub;Kim, Nak-Hee;Jung, Ho-Geun;Ha, Dong-Yeup;Jung, Ki-Hoon
    • Journal of Trauma and Injury
    • /
    • v.20 no.2
    • /
    • pp.57-64
    • /
    • 2007
  • Purpose: Clinically, acute respiratory distress syndrome (ARDS) occurs within 72 hours after acute exposure of risk factors. Because of its high fatality rate once ARDS progresses, early detection and management are essential to reduce the mortality rate. Accordingly, studies on early changes of ARDS were started, and serum ferritin, as well the as injury severity score (ISS), which has been addressed in previous studies, thought to be an early predictive indicator for ARDSMethods: From March 2003 to March 2005, we investigated 50 trauma patients who were admitted to the intensive care unit in Dongguk University Medical Center, Gyeongju. The patients were characterized according to age, sex, ISS, onset of ARDS, time onset of ARDS, serum ferritin level (posttraumatic $1^{st}\;&\;2^{nd}$ day), amount of transfused blood, and death. Abdominal computed topography was performed as an early diagnostic tool to evaluate the onset of ARDS according to its diagnostic criteria. The serum ferritin was measured by using a $VIDAS^{(R)}$ Ferritin (bioMeriux, Marcy-1' Etoile, France) kit with an enzyme-linked fluorescent assay method. For statistical analysis, Windows SPSS 13.0 and MedCalc were used to confirm the probability of obtaining a predictive measure from the receiver operating characteristics (ROC) curve. Results: The ISS varied from 14 to 66 (mean: 33.8) whereas the onset of ARDS could be predicted with the score above 30 (sensitivity: 90.0%, specificity: 60.0%, p<0.05). On the posttraumatic $1^{st}$ day, the serum ferritin levels were measured to be from 31 mg/dL to 1,200 mg/dL (mean: 456 mg/dL), and the onset of ARDS could be predicted when the value was over 340 mg/dL (sensitivity: 80.0%, specificity: 65.0%, p<0.05). On the posttraumatic $2^{nd}$ day, the serum ferritin levels were measured to be from 73 mg/dL to 1,200 mg/dL (mean: 404 mg/dL), and the onset of ARDS could be predicted when the value was over 627 mg/dL (sensitivity: 60.0%, specificity: 92.5%, p<0.05). The serum ferritin levels and the ISS were significantly higher on the posttraumatic $1^{st}$ and $2^{nd}$ day in the ARDS group, suggesting that they are suitable indices predicting the onset of ARDS, however relationship between the serum ferritin levels and the ISS was not statistically significant. Conclusion: In this study, we discovered increasing serum ferritin levels in multiple- trauma patients on the posttraumatic $1^{st}$ & $2^{nd}$ day and concluded that both the serum ferritin level and the ISS were good predictors of ARDS. Although they do not show statistically significant relationship to each other, they can be used as independent predictive measures for ARDS. Since ARDS causes high mortality, further studies, including the types of surgery and the methods of anesthesia on a large number of patients are essential to predict the chance of ARDS earlier and to reduce the incidence of death.

Vitamin C Quantification of Korean Sweet Potatoes by Cultivar and Cooking Method (국내산 고구마의 품종 및 조리방법별 비타민 C 함량)

  • Hwang, In Guk;Byun, Jae Yoon;Kim, Kyung Mi;Chung, Mi Nam;Yoo, Seon Mi
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.6
    • /
    • pp.955-961
    • /
    • 2014
  • This study was carried out to investigate the amounts of vitamin C in 22 sweet potato cultivars cultivated in Korea as well as evaluate the effects of cooking methods on vitamin C contents. Methods for determining vitamin C was validated by determining linearity, specificity, limit of detection (LOD), limit of quantification (LOQ), precision, and accuracy using HPLC. Results showed high linearity in the calibration curve with a coefficient of correlation ($R^2$) of 0.9999. The LOD and LOQ values for ascorbic acid (AA) were 0.03 and $0.10{\mu}g/mL$, respectively. The relative standard deviations (RSDs) for intra- and inter-day precision of AA were less than 5%. The recovery rates of AA and dehydroascorbic acid (DHA) were in the range from 98.21~98.64 and 98.28~100.68%, respectively. Depending on cultivar, contents of AA, DHA, and total ascorbic acid (TA) in sweet potatoes varied in the range from 37.76 (Sinyulmi)~89.25 (Juhwangmin), 23.37 (Sinjami)~63.94 (Sinyulmi), and 68.52 (Sinjami)~115.95 (Juhwangmin) mg/100 g, respectively, and their average levels were $56.98{\pm}12.53$, $36.46{\pm}9.03$, and $93.44{\pm}12.00mg/100g$, respectively. The average TA levels were also dependent on flesh color, whish was significantly higher in general sweet potato and orange sweet potato than in purple sweet potato. Steaming, baking, and frying processes significantly reduced AA (10.61~58.41%), DHA (2.57~52.81%), and TA (14.54~49.92%) contents in sweet potatoes. The highest reduction of AA, DHA, and TA contents was observed after baking, followed by steaming and frying. We expect that the basic information provided by this study will be useful to plant breeders and food scientists.

Use of Real-Time PCR and Internal Standard Addition Method for Identifying Mixed Ratio of Chicken Meat in Sausages (Real-Time PCR과 Internal Standard Addition법을 이용한 돼지고기 소시지에 혼합된 닭고기의 정량)

  • Lee, Namrye;Joo, Jae-Young;Yeo, Yong-Heon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.9
    • /
    • pp.1097-1105
    • /
    • 2017
  • This study examined how much chicken meat was in sausage made with pork. Both real-time polymerase chain reaction (PCR) and internal standard addition were used. Fifty ng of chicken DNA was added to the sausages as an internal standard. The addition of standard DNA increased the amplification efficiency of PCR and confirmed the possibility of quantitative analysis. A QIAamp DNA Micro Kit was used to improve the DNA recovery and amplification efficiency. The density of template DNA and primer were suitable for $3.0{\sim}5.0{\mu}L$ and $0.5{\mu}L$, respectively. Each DNA of pig and chicken was diluted in 10-fold from steps 50 ng to 0.05 ng. The detection limit of both pig and chicken meat was more than 0.05 ng and the correlation coefficient of the standard curve was at least 0.98. The result of the quantitative analysis after heat treatment of 3 samples of pigs and chickens mixed at 70:30 showed a 5.7% difference (64.3:35.7) between the expected value and measured value. The quantitative value was changed by affecting the DNA according to the heat treatment ($70^{\circ}C$, 10 min). An analysis of the pork and chicken content in sausages showed that it was difficult to detect chicken meat and the quantitative value of DNA according to the Ct value was very low. On the other hand, when adding standard material (50 ng of chicken DNA) to the sausages, the Ct value decreased gradually with increasing chicken mixing ratio. Thus, the mixing ratio of chicken in sausages could be estimated.

N-terminal Pro-B-type Natriuretic Peptide as a Predictive Risk Factor in Fontan Operation (Fontan 수술시 위험 예측인자로서의 N-Terminal Pro-B-type Natriuretic Peptide의 유용성)

  • Jang, Gi Young;Lee, Jae Young;Kim, Soo Jin;Shim, Woo Sup
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.12
    • /
    • pp.1362-1369
    • /
    • 2005
  • Purpose : This study aimed to investigate the correlation between the plasma level of N-terminal pro-B-type natriuretic peptide(pro-BNP) and several known risk factors influencing outcomes after Fontan operations, and to assess whether pro-BNP levels can be used as predictive risk factors in Fontan operations. Methods : Plasma pro-BNP concentrations were measured in 35 patients with complex cardiac anomalies before catheterization. Cardiac catheterization was performed in all subjects. Mean right atrium pressure, mean pulmonary artery pressure(PAP), and ventricular end-diastolic pressure(EDP) were obtained. Cardiac output and pulmonary vascular resistance were calculated by Fick method. Results : Plasma pro-BNP levels exhibited statistically significant positive correlations with mean PAP(r=0.70, P<0.001), pulmonary vascular resistance(r=0.57, P<0.001), RVEDP(r=0.63, P<0.001), LVEDP(r=0.74, P<0.001), and cardiothoracic ratio(r=0.71, P<0.001). The area under the ROC curve using pro-BNP level to differentiate risk groups in Fontan operations was high : 0.868(95 percent CI, 0.712-1.023, P<0.01). The cutoff value of pro-BNP concentrations for the detection of risk groups in Fontan operations was determined to be 332.4 pg/mL(sensitivity 83.3 percent, specificity 82.7 percent). Conclusion : These data suggest that plasma pro-BNP levels may be used as a predictive risk factor in Fontan operations, and as a guide to determine the mode of therapy during follow-up after Fontan operations.

The Clinical Usefulness of Cystatin C in Evaluating Renal Function in Children with Various Renal Diseases (다양한 신질환을 가진 소아에서 Cystatin C 검사의 임상적 유용성)

  • Kim, Khi-Joo;Kim, Joung-A;Shin, Jae-Il;Hwang, You-Sik;Cheung, Il-Chun;Lim, Jong-Baeck;Lee, Jae-Seung
    • Childhood Kidney Diseases
    • /
    • v.11 no.2
    • /
    • pp.161-167
    • /
    • 2007
  • Purpose : GFR(glomerular filtration rate) is a fundamental parameter in detecting renal impairment and predicts the progression of renal disease. Because serum creatinine has several disadvantages, serum cystatin C has been recently proposed as a new endogenous marker for GFR. We compared serum cystatin C with creatinine and creatinine clearance to investigate the clinical usefulness of cystatin C. Methods : We retrospectively analyzed 46 patients(60 case numbers) who had various renal diseases and classified them into 3 groups according to creatinine clearance(Group 1 : CrCl <40 mL/min/$1.73m^2$, Group 2 : CrCl 40-60 mL/min/$1.73m^2$, Group 3 CrCl >60 mL/min/$1.73m^2$). We measured serum creatinine, cystatin C and creatinine clearance and also analyzed the correlations among them. Results : Serum cystatin C and creatinine showed a similar correlation to creatinine clearance (r=0.685, r=0.640, respectively) and showed similar diagnostic accuracy in detecting decreased GFR(AUC, cystatin C 0.829 vs. creatinine 0.826, P=0.848). Serum cystatin C showed a greater sensitivity for detecting a decreased GFR than creatinine in Group 2 and 3(Group 1 : 100% vs. 100%, Group 2 : 70% vs. 35%, Group 3 : 46% vs. 15%). Conclusions : Serum cystatin C could be a useful endogenous marker for GFR and would be superior to serum creatinine in early detection of renal impairment in pediatric patients with renal diseases.

  • PDF

Diagnostic Value of Serum Procalcitonin in Febrile Infants Under 6 Months of Age for the Detection of Bacterial Infections (발열이 있는 6개월 미만의 영아에서 세균성 감염에 대한 procalcitonin의 진단적 가치)

  • Kim, Nam Hyo;Kim, Ji Hee;Lee, Taek Jin
    • Pediatric Infection and Vaccine
    • /
    • v.16 no.2
    • /
    • pp.142-149
    • /
    • 2009
  • Purpose : The aim of this study was to determine the diagnostic value of serum procalcitonin (PCT) compared with that of C-reactive protein (CRP) and the total white blood cell count (WBC) in predicting bacterial infections in febrile infants<6 months of age. Methods : A prospective study was performed with infants <6 months of age who were admitted to the Department of Pediatrics with a fever of uncertain source between July and September 2008. Spinal taps were performed according to clinical symptoms and physical examination. Serum PCT levels were measured using an enzyme-linked fluorescent assay. Results : Seventy-one infants (mean age, 2.62 months) were studied. Twenty-six infants (36.6%) had urinary tract infections (UTIs), and 22 infants (31.0%) had viral meningitis. The remaining infants had acute pharyngitis (n=1), herpangina (n=1), upper respiratory tract infections (n=7), acute bronchiolitis (n=8), acute gastroenteritis (n=4), and bacteremia (n=2). The median WBC and CRP levels were significantly higher in infants with UTIs than in infants with viral meningitis. However, there were no differences in the median PCT levels between the groups (0.14 ng/mL vs. 0.11 ng/mL, P=0.419). The area under the receiver operating characteristic curve was 0.792 (95% CI, 0.65-0.896) for WBC, 0.77 (95% CI, 0.626-0.879) for CRP, and 0.568 (95% CI, 0.417-0.710) for PCT. An elevated WBC count (>11,920/${\mu}L$) and an increased CRP level (>1.06mg/dL) were significant predictors of UTIs based on multiple logistic regression analysis. Conclusion : Serum PCT concentrations should be interpreted with caution in infants <6 months of age with a fever of uncertain source.

  • PDF

A study on optical coherence tomography system using optical fiber (광섬유를 이용한 광영상 단층촬영기에 관한연구)

  • 양승국;박양하;장원석;오상기;김현덕;김기문
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.5-9
    • /
    • 2004
  • In this paper, we studied the OCT(Optical Coherence Tomography) system which it has been extensively studied because of having some advantages such as high resolution cross-sectional images, low cost, and small size configuration. A basic principle of OCT system is Michelson interferometer. The characteristics of light source determine the resolution and the transmission depth. As a results, the light source have a commercial SLD with a central wavelength of 1,285 nm and FWHM(Full Width at Half Maximum) of 35.3 nm. The optical delay line part is necessary to equal of the optical path length with scattered light or reflected light from sample. In order to equal the optical path length, the stage which is attached to reference mirror is moved linearly by step motor And the interferometer is configured with the Michelson interferometer using single mod fiber, the scanner can be focused of the sample by using the reference arm. Also, the 2-dimensional cross-sectional images were measured with scanning the transverse direction of the sample by using step motor. After detecting the internal signal of lateral direction at a paint of sample, scanner is moved to obtain the cross-sectional image of 2-demensional by using step motor. Photodiode has been used which has high detection sensitivity, excellent noise characteristic, and dynamic range from 800 nm to 1,700 nm. It is detected mixed small signal between noise and interference signal with high frequency After filtering and amplifying this signal, only envelope curve of interference signal is detected. And then, cross-sectional image is shown through converting this signal into digitalized signal using A/D converter. The resolution of the OCT system is about 30$\mu\textrm{m}$ which corresponds to the theoretical resolution. Also, the cross-sectional image of ping-pong ball is measured. The OCT system is configured with Michelson interferometer which has a low contrast because of reducing the power of feedback interference light. Such a problem is overcomed by using the improved inteferometer. Also, in order to obtain the cross-sectional image within a short time, it is necessary to reduce the measurement time for improving the optical delay line.

  • PDF

Quantitative determination of inosine 5'-monophosphate dehydrogenase activity in human peripheral blood mononuclear cells by ion-pair reversed-phase high-performance liquid chromatography (이온쌍 역상 HPLC를 이용한 인체 말초혈액단핵구에서 이노신 5'-일인산 탈수소효소 활성의 정량적 측정)

  • Shin, Hye-Jin;Kwon, Soon-Ho;Park, Ji-Myeong;Kwon, Soon-Hyo;Lee, Kyoung-Ryul;Kim, Young-Jin;Lee, Sang-Hoo
    • Analytical Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.531-536
    • /
    • 2010
  • A quantitative analytical method has been established for the measurement of inosine 5'-monophosphate dehydrogenase (IMPDH) activity in human peripheral blood mononuclear cells (PBMCs) by ion-pair reversed-phase high performance liquid chromatography equipped with ultraviolet detection (HPLC/UV). IMPDH is a ${\beta}$-nicotinamide adenine dinucleotide hydrate (NAD+)-dependent dehydrogenase in which the enzyme converts inosine 5'-monophosphate (IMP) into xanthosine 5'-monophosphate (XMP). Its activity was measured by quantifying a HPLC chromatogram corresponding to XMP produced during the incubation of lysed PBMCs with IMP as a substrate and $NAD^+$ as a coenzyme. XMP produced was detected at a wavelength of 260 nm. The mobile phase was composed of a mixture of 37 mM potassium dihydrogen phosphate containing 7 mM tetra-n-butylammonium hydrogen sulfate adjusted to pH 5.5 and methanol (85:15, v/v) with a flow rate of 1 mL/min. The calibration curve was linear ($r^2$=0.999999) in the range of $0.2-50.0\;{\mu}M$ and the limit of quantification (LOQ) was $0.2\;{\mu}M$. The intra- and inter-day precisions were between 0.88-1.47% and 0.85-5.24%, respectively. The intra- and inter-day accuracies were between 98.74-99.99% and 99.95-101.65%, respectively. IMPDH activity in 11 Korean healthy volunteers ranged from 18.29 to 36.60 nmol/h/mg protein (mean = $27.70{\pm}6.28\;nmol/h/mg$ protein).

Monitoring of Pesticides in the Yeongsan and Seomjin River Basin (영산강 및 섬진강 수계 중 농약 분포 조사)

  • Lee, Young-Jun;Choi, Jeong-Heui;Kim, Sang Don;Jung, Hee-Jung;Lee, Hyung-Jin;Shim, Jae-Han
    • Korean Journal of Environmental Agriculture
    • /
    • v.34 no.4
    • /
    • pp.274-281
    • /
    • 2015
  • BACKGROUND: A lasting release of low levels of persistence chemicals including pesticides and pharmaceuticals into river has a bad influence on aquatic ecosystems and humans. The present study monitored pesticide residues in the Yeongsan and Seomjin river basins and their tributaries as a fundamental study for water quality standard of pesticides.METHODS AND RESULTS: Nine pesticides(aldicarb, carbaryl, carbofuran, chlorpyrifos, 2,4-D, MCPA, methomyl, metolachlor, and molinate) were determined from water samples using SPE-Oasis HLB(pH 2) and LC/MS/MS. Validation of the method was conducted through matrix-matched internal calibration curve, method detection limit(MDL), limit of quantification(LOQ), accuracy, precision, and recovery. MDLs of all pesticides satisfied the GV/10 values. Linearity(r2) was 0.9965- 0.9999, and a percentage of accuracy, precision, and recovery was 89.4-113.6%, 3.1-14.0%, and 90.8-106.2%, respectively. All pesticides exclusive of aldicarb were determined in the river samples, and there was a connection between the positive monitoring results and agricultural use of the pesticides.CONCLUSION: Monitoring outcomes of the present study implied that pesticides were a possible non-point pollutant source in the Yeongsan and Seomjin river basins and tributaries. Therefore, it is required to produce and accumulate more monitoring results on pesticides in river waters to set water quality standards, finally to preserve aquatic ecosystems.