• Title/Summary/Keyword: Curve detection

Search Result 858, Processing Time 0.029 seconds

A study on the discriminant analysis of node deployment based on cable type Wi-Fi in indoor (케이블형 Wi-Fi 기반 실내 공간의 노드 배치 판별 분석에 관한 연구)

  • Zin, Hyeon-Cheol;Kim, Won-Yeol;Kim, Jong-Chan;Kim, Yoon-Sik;Seo, Dong-Hoan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.836-841
    • /
    • 2016
  • An indoor positioning system using Wi-Fi is essential to produce a radio map that combines the indoor space of two or more dimensions, the information of node positions, and etc. in processing for constructing the radio map, the measurement of the received signal strength indicator(RSSI) and the confirmation of node placement information counsume substantial time. Especially, when the installed wireless environment is changed or a new space is created, easy installation of the node and fast indoor radio mapping are needed to provide indoor location-based services. In this paper, to reduce the time consumption, we propose an algorithm to distinguish the straight and curve lines of a corridor section by RSSI visualization and Sobel filter-based edge detection that enable accurate node deployment and space analysis using cable-type Wi-Fi node installed at a 3 m interval. Because the cable type Wi-Fi is connected by a same power line, it has an advantage that the installation order of nodes at regular intervals could be confirmed accurately. To be able to analyze specific sections in space based on this advantage, the distribution of the signal was confirmed and analyzed by Sobel filter based edge detection and total RSSI distribution(TRD) computation through a visualization process based on the measured RSSI. As a result to compare the raw data with the performance of the proposed algorithm, the signal intensity of proposed algorithm is improved by 13.73 % in the curve section. Besides, the characteristics of the straight and the curve line were enhanced as the signal intensity of the straight line decreased by an average of 34.16 %.

Print-Scan Resilient Curve Watermarking using B-Spline Curve Model and its 2D Mesh-Spectral Transform (B-스프라인 곡선 모델링 및 메시-스펙트럼 변환을 이용한 프린트-스캔에 강인한 곡선 워터마킹)

  • Kim, Ji-Young;Lee, Hae-Yeoun;Im, Dong-Hyuck;Ryu, Seung-Jin;Choi, Jung-Ho;Lee, Heung-Kyu
    • The KIPS Transactions:PartB
    • /
    • v.15B no.4
    • /
    • pp.307-314
    • /
    • 2008
  • This paper presents a new robust watermarking method for curves that uses informed-detection. To embed watermarks, the presented algorithm parameterizes a curve using the B-spline model and acquires the control points of the B-spline model. For these control points, 2D mesh are created by applying Delaunay triangulation and then the mesh spectral analysis is performed to calculate the mesh spectral coefficients where watermark messages are embedded in a spread spectrum way. The watermarked coefficients are inversely transformed to the coordinates of the control points and the watermarked curve is reconstructed by calculating B-spline model with the control points. To detect the embedded watermark, we apply curve matching algorithm using inflection points of curve. After curve registration, we calculate the difference between the original and watermarked mesh spectral coefficients with the same process for embedding. By calculating correlation coefficients between the detected and candidate watermark, we decide which watermark was embedded. The experimental results prove the proposed scheme is more robust than previous watermarking schemes against print-scan process as well as geometrical distortions.

Performance Evaluation of Several Radon Detectors in the Standard Chamber and Dwellings (라돈 표준실과 가옥 내에서 일부 라돈검출기에 대한 성능 평가)

  • Yoon, Seok-Won;Kim, Yong-Jae;Chang, Byung-Uck;Byun, Jong-In;Yun, Ju-Yong
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.4
    • /
    • pp.173-181
    • /
    • 2008
  • To ensure the performance of radon detectors, three passive radon detectors ($RadTrak^{(R)}$, $Radopot^{(R)}$, and $E-PERM^{(R)}$)have been reviewed. The difference ratios of RadTrak and Radopot tested in the radon standard chamber were -13.2% and -6.0%, respectively, which were in good accordance within 20% of the value measured by $AlphaGUARD^{(R)}$. To ensure the performance of the long term measurement, the 3 detectors were installed at the same position of approximately one hundred of dwellings for one year. The correlation curve between RadTrak and Radopot shows good agreement with a correlation coefficient ($R^2$) of 0.91. However, The correlation curve between E-PERM and Radopot shows bad agreement ($R^2$ = 0.021). In addition, the distribution map of annual mean indoor gamma dose rate measured with E-PERM was not in accordance with the distribution map of outdoor gamma dose rate measured by Portable Ion Chamber. According to the results, some requisites for the selection of the radon passive detectors in the large-scale indoor radon survey were discussed.

Detection Characteristics of TL, ESR and DNA Comet for Irradiated Soybeans (열발광, 전자스핀공명 및 DNA Comet 분석에 의한 대두의 방사선 조사 여부 검지 특성)

  • Lee, Eun-Young;Jeong, Jae-Young;Noh, Jung-Eun;Jo, Deok-Jo;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.18-23
    • /
    • 2002
  • The detection characteristics of gamma-irradiated $(0{\sim}4\;kGy)$ soybeans produced in Korea and China were investigated by thermoluminescene (TL), electron spin resonance (ESR), and DNA comet assay. The TL glow curves were shown at around $200^{\circ}C$ for irradiated soybeans, while that at $280^{\circ}C$ for the non-irradiated one. The normalization with a re-irradiation step at 1 kGy could verify the above detection results. The Korean soybean showed higher glow curves than Chinese did. The ESR spectroscopy for husks of irradiated soybeans revealed specific signals (g = 2.02374, 1.98715) derived from cellulose radical, which intensities were proportional to irradiation does, with the higher peaks in Chinese sample than Korean one. The DNA comet for the non-irradiated sample showed no or little tails, while those for irradiated samples above 0.5 kGy were remarkably changed in their length, size, and concentration, thus resulting in distinguishing non-irradiated from irradiated samples. As a result, TL, ESR, and DNA comet determinations were found suitable for the detection of irradiated soybean at 0.5 kGy or more, and negligible differences were observed between Korean and Chinese origins in their detection characteristics.

Forensic Decision of Median Filtering Image Using a Coefficient of Variation of Fourier Transform (Fourier 변환 변이계수를 이용한 미디언 필터링 영상의 포렌식 판정)

  • RHEE, Kang Hyeon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.8
    • /
    • pp.67-73
    • /
    • 2015
  • In a distribution of digital image, there is a serious problem that is the image alteration by a forger. For the problem solution, this paper proposes the forensic decision algorithm of a median filtering (MF) image using the feature vector based on a coefficient of variation (c.v.) of Fourier transform. In the proposed algorithm, we compute Fourier transform (FT) coefficients of row and column line respectively of an image first, then c.v. between neighboring lines is computed. Subsquently, 10 Dim. feature vector is defined for the MF detection. On the experiment of MF detection, the proposed scheme is compared to MFR (Median Filter Residual) and Rhee's MF detection schemes that have the same 10 Dim. feature vector both. As a result, the performance is excellent at Unaltered, JPEG (QF=90), Down scaling (0.9) and Up scaling (1.1) images, and it showed good performance at Gaussian filtering ($3{\times}3$) image. However, in the performance evaluation of all measured items of the proposed scheme, AUC (Area Under ROC (Receiver Operating Characteristic) Curve) by the sensitivity and 1-specificity approached to 1 thus, it is confirmed that the grade of the performance evaluation is rated as 'Excellent (A)'.

Influence of kilovoltage- peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants

  • Fontenele, Rocharles Cavalcante;Nascimento, Eduarda Helena Leandro;Imbelloni-Vasconcelos, Ana Catarina;Martins, Luciano Augusto Cano;Pontual, Andrea dos Anjos;Ramos-Perez, Flavia Maria Moraes;Freitas, Deborah Queiroz
    • Imaging Science in Dentistry
    • /
    • v.52 no.3
    • /
    • pp.267-273
    • /
    • 2022
  • Purpose: The aim of this study was to assess the influence of kilovoltage- peak (kVp) and the metal artifact reduction (MAR) tool on the detection of buccal and lingual peri-implant dehiscence in the presence of titanium-zirconia (Ti-Zr) and zirconia (Zr) implants in cone-beam computed tomography (CBCT) images. Materials and Methods: Twenty implant sites were created in the posterior region of human mandibles, including control sites (without dehiscence) and experimental sites (with dehiscence). Individually, a Ti-Zr or Zr implant was placed in each implant site. CBCT scans were performed using a Picasso Trio device, with variation in the kVp setting (70 or 90 kVp) and whether the MAR tool was used. Three oral radiologists scored the detection of dehiscence using a 5-point scale. The area under the receiver operating characteristic (ROC) curve, sensitivity, and specificity were calculated and compared by multi-way analysis of variance (α=0.05). Results: The kVp, cortical plate involved (buccal or lingual cortices), and MAR did not influence any diagnostic values (P>0.05). The material of the implant did not influence the ROC curve values(P>0.05). In contrast, the sensitivity and specificity were statistically significantly influenced by the implant material (P<0.05) with Zr implants showing higher sensitivity values and lower specificity values than Ti-Zr implants. Conclusion: The detection of peri-implant dehiscence was not influenced by kVp, use of the MAR tool, or the cortical plate. Greater sensitivity and lower specificity were shown for the detection of peri-implant dehiscence in the presence of a Zr implant.

Assessment of the Object Detection Ability of Interproximal Caries on Primary Teeth in Periapical Radiographs Using Deep Learning Algorithms (유치의 치근단 방사선 사진에서 딥 러닝 알고리즘을 이용한 모델의 인접면 우식증 객체 탐지 능력의 평가)

  • Hongju Jeon;Seonmi Kim;Namki Choi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.3
    • /
    • pp.263-276
    • /
    • 2023
  • The purpose of this study was to evaluate the performance of a model using You Only Look Once (YOLO) for object detection of proximal caries in periapical radiographs of children. A total of 2016 periapical radiographs in primary dentition were selected from the M6 database as a learning material group, of which 1143 were labeled as proximal caries by an experienced dentist using an annotation tool. After converting the annotations into a training dataset, YOLO was trained on the dataset using a single convolutional neural network (CNN) model. Accuracy, recall, specificity, precision, negative predictive value (NPV), F1-score, Precision-Recall curve, and AP (area under curve) were calculated for evaluation of the object detection model's performance in the 187 test datasets. The results showed that the CNN-based object detection model performed well in detecting proximal caries, with a diagnostic accuracy of 0.95, a recall of 0.94, a specificity of 0.97, a precision of 0.82, a NPV of 0.96, and an F1-score of 0.81. The AP was 0.83. This model could be a valuable tool for dentists in detecting carious lesions in periapical radiographs.

Evaluation of Cancer Detection Efficiency by Means of Hybrid and Inverse Filter in Chest Radiography (디지털 흉부 방사선 영상에서 Hybrid Filter와 Inverse Filter를 적용한 종양의 검출능 평가)

  • Kim, Youn-Young;Kim, Tae-Young;Kim, Hyun-Ji;Park, Min-Seock;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.319-326
    • /
    • 2013
  • The purpose of this study is to evaluate usefulness of Hybrid image and Inverse image about detection of tumor shadow in chest radiography using ROC analysis. Original images of 60 cases are selected from Standards digital image date base issued by the Japanese Society of Radiological Technology. Through computer language of C, Inverse images of 60 cases and Hybrid image of 30 cases are made. The continues reading experiment was conducted. In the case of inverse image were observed by 5 radiographer and 2 radiologist. In the case of In case of Hybrid image were observed by 3 student radiographer and 2 experienced radiographer. ROC curve are constructed using ROCKIT Program made by Metz. In Inverse image, a Az of average ROC curve was increases from 0.742 of original image to 0.775 of inverse image. In normal cases, the effect of the detrimental is same to that of the beneficial, however In abnormal cases, the beneficial effect is greater than detrimental effect. However in Hybrid image, a Az of average ROC curve was decreases from 0.5253 of original image to 0.4868 of Hybrid image. In Normal cases, the effect of the detrimental is greater than that of the Beneficial, however In abnormal cases, the Beneficial effect is greater than detrimental effect. The inverse image can be more positively considered for the detecting of tumor than the hybrid image.

Application of PSL-TL Combined Detection Method on irradiated Composite Seasoning Products and Spices (방사선 조사 복합조미식품과 향신료의 확인을 위한 PSL-TL의 적용)

  • Chung, Hyung-Wook;Park, Sung-Kug;Han, Sang-Bae;Choi, Dong-Mi;Lee, Dong-Ha
    • Journal of Food Hygiene and Safety
    • /
    • v.23 no.3
    • /
    • pp.206-211
    • /
    • 2008
  • Photostimulated luminescence(PSL)-Thermoluminescence(TL) combined analysis was applied to detect whether composite seasoning products and spices were irradiated or not. Samples were irradiated with $^{60}Co$ at $0{\sim}7$ kGy. A total of 12 different samples(6 of composite seasoning products and 6 of spices) was examined. Depending on the PSL results, TL analysis was performed. In case of both PSL positive(${\geq}5,000$ counts) and intermediate($700{\sim}5000$ counts), TL analysis had to be performed to confirm the result of PSL. Using TL, the shape of the glow curve(Glow 1) made it possible to identify the irradiated samples. In addition, The TL glow ratio(Glow 1/Glow 2) obtained by normalization was less than 0.1 for the non-irradiated samples and ${\geq}0.29$ for irradiated ones, respectively.

Bioconjugation by dual heterobifunctional coupling method: Use of the conjugates for the detection of dopamine (서로 다른 두 작용기를 이용한 결합법에 의한 접합체: 도파민 면역분석법)

  • Ryu, Ji-Eun;Rhee Paeng, In-Sook
    • Analytical Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.537-543
    • /
    • 2010
  • Dopamine (DA) is an important neurotransmitter molecule of catecholamines. Its deficiency could lead to brain disorder such as Parkinson's disease and schizophrenia. Therefore, it is necessary to establish a suitable analytical technique with sensitivity and simplicity. A competitive enzyme-linked immunosorbent assay for DA has been optimized and characterized. Assay sensitivity is controlled by two factors in competitive immunoassay. One is a nature and concentration of competitor, and the other is those of binder, antibody. Thus, optimization was performed: BSA-DA conjugate and antibody-avidin conjugate were prepared by dual heterobifunctional coupling method using SATA and SMCC. Assay condition was optimized with $6.66\;{\mu}gmL^{-1}$ of BSA-DA and $4.17{\times}10^{-10}\;M$ of antibody-avidin conjugate. A dose-response curve was constructed, and a limit of detection and a dynamic range for DA were accomplished to $2.3{\times}10^{-2}\;{\mu}g\;mL^{-1}$ and four orders of magnitude ($1.0{\times}10^{-7}\;M$ to $1.0{\times}10^{-3}\;M$), respectively. Calibration curve was constructed on dynamic range and least-squares regression of this data gave the following relationship: absorbance = -0.1098 log[DA]+0.0353 ($R^2$ = 0.9956).