• Title/Summary/Keyword: Current-unbalance

Search Result 263, Processing Time 0.027 seconds

Series-Active and Shunt-Pasive Type Power Filter Compensating Harmonic Currents and Unbalanced Voltages of Source (직렬형 능동필터와 수동형 병렬필터를 이용한 전원불평형 및 고조파 전류 보상)

  • Lee G-Myoung;Lee Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.565-568
    • /
    • 2001
  • A novel control scheme compensating for source voltage unbalance and harmonic current for series active power filters is proposed, where the references for voltage unbalance and current harmonic and phase angle is derived from the positive sequence component of the source voltage obtained simply through digital all-pass filters, which makes the whole control algorithm simpler than other methods using p-q theory. In addition, the harmonic component of source current is compensated by harmonic component of load voltage and therefore fundamental component of source current is considered as separated terms for the control issue. The validity of the proposed scheme has been verified by experimental results.

  • PDF

A Study on the Effect of Cab Signal through Unbalance of the Traction Return Current (귀선전류의 불평형에 따른 차상신호에 미치는 영향에 관한 연구)

  • Lee, Tae-Hoon;Park, Ki-Bum;Sung, Soon-Uk
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1694-1700
    • /
    • 2007
  • In the electrified section, both of return current and signal current are flowing in the same rail in common. But signal current shall be allowed to flow in the specific track circuit and not in the other circuit while the traction return current shall come back to power sub-station. This paper presents measuring system that use both sensor and antenna. The aim of the system is to achieve the difference in current between the two rails and the presence of trimming capacitors. In order to improve the transmission level, trimming capacitors are connected between the two rails at constant spacing. To maintain the balance of traction return current, rails of both sides may be jointed by the so-called SVPMM. The traction return current is sometimes unbalanced owing to the ill-contact of SVPMM. In this paper, we propose a diagnosis method based on a short-circuited current(Icc), trimming capacitors and traction return current measured by Korail inspection vehicles. Whether Icc is good or bad depends not only on the presence of trimming capacitors but also on the unbalance of the traction return current.

  • PDF

Control of HVDC-MMC Considering the Switching Device's Current Capacity and Circulating Current under Unbalanced Voltage Conditions (불평형 전압 조건에서 스위칭 소자의 전류 용량과 순환전류를 고려한 HVDC-MMC 제어기법)

  • Moon, Ji-Woo;Pae, Deuk-Woo;Park, Jung-Woo;Kang, Dea-Wook;Yoo, Dong-Wook;Kim, Jang-Mok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.270-278
    • /
    • 2013
  • This paper proposes a control method for high voltage direct current(HVDC) with modular multilevel converter (MMC) under unbalanced voltage conditions considering the submodule(SM)'s current capacity and circulating current. It is aimed to propose a control method in which the current peak value does not exceed the maximum value of HVDC-MMC by considering the current capacity of the SM under unbalance voltage conditions. And it analyzes the effect of the unbalanced voltage on circulating currents in MMC and then proposes a control method considering each component of circulating currents under unbalanced voltages. The effectiveness of the proposed controlling method is verified through simulation results using PSCAD/EMTDC.

Design of a Photovoltaic PCS with Compensation Control of Reactive Power and Unbalance Current in Three-phase systems (3상 시스템의 무효전력, 불평형 전류 보상 기능을 갖는 태양광 전력변환장치 설계)

  • Park, Sang-Min;Kim, Chang-Soon;Le, Dinh Vuong;Park, Minwon;Yu, In-Keun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.21 no.3
    • /
    • pp.29-33
    • /
    • 2016
  • Development of the distributed energy resources such as photovoltaic, wind, and fuel cell has increased rapidly due to the rising demand for clean energy utilization. On the other hand, the distribution system became complex and has problems such as degradation of power factor and current unbalance caused by power converters, reactive power and unbalanced loads. To solve these problems, this paper proposes a 3-phase 4-leg type power conditioning system with compensation control algorithm for the reactive power and unbalance current in distribution system using photovoltaic resource. It is simulated in PSCAD/EMTDC and the effectiveness is confirmed.

Behavior of a Balance Shaft regarding Unbalance Mass Distribution (밸런스 샤프트 불평형 질량의 분포에 따른 동적 거동 연구)

  • Kim, Chan-Jung;Bae, Chul-Yong;Lee, Bong-Hyun;Kwon, Sung-Jin;Kim, Hyun-Chul;Lee, Dong-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.101-106
    • /
    • 2006
  • Balance shaft has a key role in reducing a engine vibration in a vehicle and widely applied for current models. Since balance shaft module consists many sub-component and each part has its own operational characteristics, some different analysis backgrounds should be integrated into one sub-part in balance shaft module and this is the main obstacles in making a design process. Moreover, the balancing shaft is rotating in high speed and such condition requires large safety factors in a design process owing to a lot of unexpected problems with the overwhelming rotation. Balance shaft is the core-component generating the intended unbalance as well as cancelling the unbalance force or moment by the engine module. So, the balance shaft should meet the high fatigue resistance not to mention of NVH performance. In this paper, a design strategy focused on balance shaft is developed to build a optimal model considering a engine vibration. Putting the unbalance mass distribution as main design parameter, some candidate model is verifed with structural and fatigue analysis and most appropriate model is proposed here.

  • PDF

Control of a 3-Phase VR Type Self-Bearing Step Motor (3상 가변형 셀프 베어링 스텝모터의 제어)

  • Kim, Dae-Gon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.12
    • /
    • pp.1974-1980
    • /
    • 2001
  • The control algorithm of a new type self-bearing step motor is presented. The motor actuator is used for both motor and bearing functionality without any redundant coil windings or redundant electromagnets. The self$.$bearing step motor layout and its control method are described. A linearized farce-current-displacement relationship is derived. As the result of the unbalance response approach, the constant torque production is possible fur the supply current regulation algorithm. And even if the bearing functionality is added in the motor functionality, no additional current for bearing functionality is possible, and this leads to minimize the net power loss. Also, the unbalance response shows the independent bearing force and motor torque.

A study on MPPT control using the balace/unbalance control (평형/불평형 제어를 이용한 MPPT제어에 과한 연구)

  • K., T.K.;K., G.H.;C., K.J.;P., J.W.;Matsui, M.;L., H.W.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.334-336
    • /
    • 2005
  • This paper proposes a simple MPPT control scheme of a Current- Control-Loop Error system Based that can be obtains a lot of advantage to compare with another digital control method, P&O and IncCond algorithm, that is applied mostly a PV system. An existent method is needed an expensive processor such as DSP that calculated to change the measure power of a using current and voltage sensor at the once. But, a proposed method is easy to solve the cost reduction and power unbalance problems that it is used by control scheme to limit error of a current control of common sensor. This proposed algorithm had verified through a simulation and an experiment on battery charger using PIC that is the microprocessor of a low price.

  • PDF

Analysis of Volatage and Current Waveform Distortion Characteristics at Office Buildings (사무용 빌딩에서의 전압 및 전류파형 왜곡특성 분석)

  • Yoo, Jae-Geun;Lee, Sang-lck;Jeon, Jeong-Chay;Jeong, Jong-Wook;Lim, Young-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.155-161
    • /
    • 2005
  • Nonlinear electronic loads used at office buildings distort the voltage and current waveform that cause the overheating of transformer losses, ELB(Electrical Leakage Breaker) tripping, and so on. This paper analyzed waveform distortion characteristics at several once buildings by comparing with magnitude of voltage and current harmonics, crest factor of voltage and current, phase voltage and current unbalance. As a consequence, severe current waveform distortion in phase and neutral line by harmonics and high current unbalance rates by unbalanced using of single loads among the three phases are investigated. The results of the study can be used in making decisions regarding reasonable and economical operating of loads at office buildings.

Design and Implementation of Solar PV for Power Quality Enhancement in Three-Phase Four-Wire Distribution System

  • Guna Sekar, T.;Anita, R.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.75-82
    • /
    • 2015
  • This paper presents a new technique for enhancing power quality by reducing harmonics in the neutral conductor. Three-Phase Four-Wire (3P4W) system is commonly used where single and three phase loads are connected to Point of Common Coupling (PCC). Due to unbalance loads, the 3P4W distribution system becomes unbalance and current flows in the neutral conductor. If loads are non-linear, then the harmonic content of current will flow in neutral conductor. The neutral current that may flow towards transformer neutral point is compensated by using a series active filter. In order to reduce the harmonic content, the series active filter is connected in series with the neutral conductor by which neutral and phase current harmonics are reduced significantly. In this paper, solar PV based inverter circuit is proposed for compensating neutral current harmonics. The simulation is carried out in MATLAB/SIMULINK and also an experimental setup is developed to verify the effectiveness of the proposed method.

Droop Control Scheme of a Three-phase Inverter for Grid Voltage Unbalance Compensation

  • Liu, Hongpeng;Zhou, Jiajie;Wang, Wei;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1245-1254
    • /
    • 2018
  • The stability of a grid-connected system (GCS) has become a critical issue with the increasing utilization of renewable energy sources. Under grid faults, however, a grid-connected inverter cannot work efficiently by using only the traditional droop control. In addition, the unbalance factor of voltage/current at the common coupling point (PCC) may increase significantly. To ensure the stable operation of a GCS under grid faults, the capability to compensate for grid imbalance should be integrated. To solve the aforementioned problem, an improved voltage-type grid-connected control strategy is proposed in this study. A negative sequence conductance compensation loop based on a positive sequence power droop control is added to maintain PCC voltage balance and reduce grid current imbalance, thereby meeting PCC power quality requirements. Moreover, a stable analysis is presented based on the small signal model. Simulation and experimental results verify the aforementioned expectations, and consequently, the effectiveness of the proposed control scheme.