A pin type current probe using Planar Hall Resistance magnetic sensor (PHR 자기센서를 적용한 탐침형 전류 프로브)

  • Lee, Dae-Sung;Lee, Nam-Young;Hong, Sung-Min;Kim, CheolGi
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.342-348
    • /
    • 2021
  • For the characterization or failure analysis of electronic devices such as PCB (printed circuit boards), the most common method is the measurement of voltage waveforms with an oscilloscope. However, because there are many types of problems that cannot be detected by voltage waveform analysis, several other methods such as X-ray transmission, infrared imaging, or eddy current measurement have been applied for these analyses. However, these methods have also been limited to general analyses because they are partially useful in detecting physical defects, such as disconnections or short circuits. Fundamentally current waveform measurements during the operation of electronic devices need to be performed, however, commercially available current sensors have not yet been developed, particularly for applications in highly integrated PCB products with sub-millimeter fine pitch. In this study, we developed a highly sensitive PHR (planar hall resistance) magnetic sensor for application in highly integrated PCBs. The developed magnetic sensor exhibited sufficient features of an ultra-small size of less than 340 ㎛, magnetic field resolution of 10 nT, and current resolution of 1 mA, which can be applicable for PCB analyses. In this work, we introduce the development process of the magnetic sensing probe and its characteristic results in detail, and aim to extend this pin-type current probe to applications such as current distribution imaging of PCBs.

Synthesis of BaTiO3 Thin Film on Ti Electrode by the Current Pulse Waveform (펄스전류파형을 이용한 Ti 전극위에서 BaTiO3박막의 합성)

  • Kang, Jinwook;Tak, Yongsug
    • Applied Chemistry for Engineering
    • /
    • v.9 no.7
    • /
    • pp.998-1003
    • /
    • 1998
  • $BaTiO_3$ thin film was electrochemically deposited on Ti electrode in a 0.4 M $Ba(OH)_2$ solution of $85^{\circ}C$ using a current pulse waveform. Both $BaTiO_3$ crystallinity and faradaic efficiency for the film formation were enhanced with the increase of cathodic current density and pulse time. Based on the surface analysis and electrochemical studies, it was suggested that, during cathodic pulsed, the surface pH increase due to the reduction of $H_2O$ accelerates the structural changes of Ti oxides which were formed during anodic cycle. Prior to experiments, Ti oxides were intentionally grown in 0.1 M $H_2SO_4$ solution and the effect of initial oxide film thickness on the $BaTiO_3$ film formation was investigated. The migration of $Ti^{+4}$ ions through the oxide film was retarded with the increase of film thickness and it was observed that the crystallization of $BaTiO_3$ was only limited to the defect area of surface oxides.

  • PDF

Analysis on Waveform of Leakage Current of Contaminated EPDM Insulators by Salt Fog (Salt fog에 의한 오손된 EPDM애자의 누설전류 파형 분석)

  • Park, Jae-Jun;Song, Young-Chul;Kim, Jeong-Boo;Lee, You-Min;Lee, Hyun-Dong;Jung, Young-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.36-41
    • /
    • 2003
  • This paper presents the results of power spectra using the fundamental and low frequency harmonic components of leakage current waveform to study aging on contaminated EPDM insulator(was serviced during 1997-2001, region Pohang, korea) under salt fog conditions. Experiments have been conducted in the chamber salt fog and at the 16KVrms. The salt contents adjusted as 0g,25g,50g and 75g per liter of deionized water. The onset of dry-band arcing on polymer insulators could be determined by signal processing the low frequency harmonics components. A correlation has been found between the fundamental and low harmonic components of power spectra on leakage current. Where aging could be associated with an increase in the level of both the fundamental and low frequency harmonics components of leakage current. Surface aging for contaminated EPDM insulators occurred when the fundamental component of leakage current was greater then some level On the other hand, when the polymer insulator approached failure, the fundamental component of leakage current reached relatively high values and low frequency harmonics components of the leakage current trended to decrease. The results suggest that both the fundamental and low frequency harmonics of leakage current can be used as a tool to determine both the beginning of aging and before flashover, end of life EPBM insulator in salt fog.

  • PDF

Study on Restriking Transient Voltage Characteristics and Waveform Patterns of Planar Copper-Carbon Electrodes using Forms (평면형 구리 - 탄소 전극의 형태별 재기전압 특성 및 파형 패턴에 관한 연구)

  • Lim, Jong-Min;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.1-6
    • /
    • 2020
  • In this study, the authors measured voltage and current waveforms in real time during a serial arc discharge. The analysis results of the arc discharge radiation patterns exhibited intermittent discharge, arc growth, creation of a heat generating area, occurrence of plume, and formation of a red heat area, which proceeded in that order. When the serial arc discharge was introduced, the current and voltage waveforms exhibited periodicity as sine waves. It was also observed that a restriking transient voltage occurred when the waveform changed from positive (+) to negative (-) and vice versa. When the discharge proceeded, the amount of heat generated for 1 s and 600 s was approximately 0.317 mJ, and 190 mJ, respectively. The duration of the short circuit was approximately 1.66 ms, and in the case of the voltage waveform, it was evident that the electric potential increased to 49.9 V in the same cycle. Furthermore, when the discharge proceeded, the effective value (RMS value) of the current was approximately 1.72 A with a maximum current of approximately 2.53 A, whereas the effective value of the voltage was approximately 42.8 V with a maximum of approximately 208 V.

Special quality research about action output waveform change by gap (1.0mm and 1.6mm) difference of $CO_2$ laser for skin disease (피부질환을 위한 $CO_2$ 레이저의 공극 (1.0mm 및 1.6mm)차이에 따른 동작출력 파형변화에 관한 특성연구)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.156-158
    • /
    • 2007
  • Laser wave length can have evaporation effect by absorption because outer skin or tissue of focus is consisted of water almost though absorption of water occurs more than 90% almost in formation thickness of very thin floor Can operate outer skin, steam by floor and correct incision of formation is available. Suture surgical operation is avaliable to vein or lymph system and surgical operation region can dry and see as eye and radish bleeding surgical operation is avaliable Specially, stability of tube both end output about pulse by weight very, this research can cause various curative effect because can reduce bulk and control easily current wave style of medical laser using electric power conversion device of high frequency way. If introduce ZVS (Zero Voltage Switching) or ZVZCS (Zero Voltage and Zero Current Switching), is more profitable because can reduce switching damage Because electric power department of proposed medical laser can do stable soft-switching in wide subordinate extent introducing ZVZCS technique by the first help and control department composes microcontroller, output current waveform user have free form make. Result that experiment because design and manufacture, brought result that improve of 20% than existing equipment, and will be bought to get into superior result if supplement as systematic late.

  • PDF

The Arc Fault Determination Method for the Electric Fire Prevention (전기화재 방지를 위한 아크고장 판단기법에 대한 연구)

  • Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.3 no.4
    • /
    • pp.260-265
    • /
    • 2008
  • The arc-fault occurring in the customer system becomes the direct cause of electric fire. However, it is very difficult to identify the arc-fault using the existing fault detection mechanism because the magnitude of the fault current is very small. Accordingly, this paper analyzes the causes of arc fault and designs the basic detection mechanism of arc fault. And then, it proposes an signal processing-based arc-fault determination methodology which can enhance the of accuracy of the arc-fault determination by applying DFT/DWT to the voltage and current waveform. Finally, this paper showed the application methodology of the proposed signal processing based fault determination method by applying and analyzing DFT/DWT to an high voltage in-rush current waveform.

  • PDF

Special quality research about action output waveform change by gap (1.0mm and 1.6mm) difference of $CO_2$ laser for skin disease (피부질환을 위한 $CO_2$ 레이저의 공극차이에 따른 동작출력 변화에 관한 연구)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.52-54
    • /
    • 2007
  • Laser wave length can have evaporation effect by absorption because outer skin or tissue of focus is consisted of water almost though absorption of water occurs more than 90% almost in formation thickness of very thin floor. Can operate outer skin, steam by floor and correct incision of formation is available. Suture surgical operation is available to vein or lymph system and surgical operation region can dry and see as eye and radish bleeding surgical operation is available. Specially, stability of tube both end output about pulse by weight very, this research can cause various curative effect because can reduce bulk and control easily current wave style of medical laser using electric power conversion device of high frequency way. If introduce ZVS (Zero Voltage Switching) or ZVZCS (Zero Voltage and Zero Current Switching), is more profitable because can reduce switching damage. Because electric power department of proposed medical laser can do stable soft-switching in wide subordinate extent introducing ZVZCS technique by the first help and control department composes microcontroller, output current waveform user have free form make. Result that experiment because design and manufacture, brought result that improve of 20% than existing equipment, and will be bought to get into superior result if supplement as systematic late.

  • PDF

A Study on Novel High Performance SRM Drive (새로운 고성능 SRM 운전방식에 관한 연구)

  • 오인석;구인수;박한웅;성세진
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.399-406
    • /
    • 1998
  • This paper proposes an instantaneous torque control method for the high performance SRM drive. In first, we e establish SRM model with the characte1istics of the torque. phase current and rotor position which were measured in t the experimental SRM. Based on this model. the reference torque waveform to minimize torque ripple is obtained by t the control of resultant torque considering phase torque overlap according to the variation of load and speed. And the r reference current waveform for the tracking of reference torque are decided. The control method for tracking the r reference current is used the delta modulation technique. The proposed method is validated by the comparing with S simulation and experimental results.

  • PDF

A Study on Welding Performance Improvement of Inverter Arc Welding Machine using Instantaneous Output Current Control Method

  • Chae, Y.M.;Gu, J.Y.;Gho, J.S.;Mok, H.S.;Choe, G.H.;Won, C.Y;Kim, G.S.
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.1012-1016
    • /
    • 1998
  • According to the adoption of inverter circuit topology for welding machine area, the improvement of welding performance can be achieved. However conventional CO2 inverter arc welding machine uses the constant voltage characteristics. So the metal transfer is performed under unoptimum condition in the sence of spatter generation. In this paper the new control algorithm is proposed for welding machine, which is the instantaneous output current control method using single chip microprocessor. But the optimum waveform of welding current is still uncertain, as a first step for figuring out the optimized waveforms, this study was performed. And as a result of performance test of the proposed system, it was demonstrated that all of the waveform variation parameter could be set individually and the generated spatter is reduced compared to conventional inverter arc welding machine.

  • PDF