• 제목/요약/키워드: Current transformer (CT)

검색결과 114건 처리시간 0.03초

과단면적 계수를 고려한 철심 변류기 설계 방법 (An Iron-cored CT Design Considering Overdimensioning Factor)

  • 이주훈;강상희;이승재;강용철;배주천;안준기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.834-836
    • /
    • 1998
  • Current transformer (CT) saturation may cause a variety of protective relays to malfunction. The conventional CT is designed that it can carry up to 20 times the rated current. However, the possibility of CT saturation still remains, because the fault current may have substantial amounts of ac and/or de components. This paper presents a iron-cored CT design method to prevent CT saturation. The proposed method employs the overdimensioning factor $(K_{ta})$ considering dc components contained as well as symmetrical ac components in the fault current.

  • PDF

BSO를 이용한 광CT, PT 개발 (Development of Optical CT and PT using BSO Single Crystal)

  • 심건학;이복규;조홍근;김요희;김영수;박해수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 A
    • /
    • pp.491-494
    • /
    • 1992
  • This paper described the development example of optical CT(Current Transformer) and optical PT (Potential Transformer) which is measurement system of current and voltage of electric power line using Electro-Optic effect and Magneto-Optic effect. We designed the optical CT of 22KV class and 154KV class and an optical PT of 22KV class. And now the filed testing is in progress in a KEPCO's substation.

  • PDF

고압계통 변류기 동작 특성 검토 (A Study on Performance of Current Transformer in High Voltage System)

  • 최기열;이덕수;박문빈;김희택;장기풍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.5-7
    • /
    • 2006
  • Current transformers(CTs) whose rating is selected per a full load current of a feeder in high voltage system can be easily saturated due to high fault current that may be several hundred times of the full load current of the feeder. However, the protective relay shall operate properly at the fault without mis-operation under the CT saturation. So, in selecting the CT rating, it is necessary to consider the behaviour of CT and a performance of protection scheme in condition where CT can be saturated. In this paper, a performance of CT and a degree of saturation are studied and verified whether its ratings are proper for the operation of the protective relay.

  • PDF

내삽법 기반의 최소자승법을 이용한 개선된 CT 포화 복원 알고리즘 (An Enhanced Compensation Algorithm for the CT Saturation Using Interpolation-based LSQ(Least Square) Fitting Method)

  • 류기찬;강상희;이봉현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.14-15
    • /
    • 2006
  • A saturation of magnetic flux in the core may occur when a large primary current flows when the iron-cored current transformer is used. This saturation makes the distorted secondary current of the CT. the distorted secondary current may cause the mal-operation or operation time delay of protective relays. CT compensation algorithm using The LSQ(Least Square) fitting method has a problem. It needs to acquire enough data for executing this algorithm without an error. In this paper, an enhanced algorithm using interpolation based LSQ(Least Square) Fitting Method is proposed. The Lagrange Interpolation Method is used for the interpolation and CT is simulated by EMTP. The results show that the proposed algorithm can accurately compensate a distorted secondary current more than existing Algorithm when the saturation severely occurs.

  • PDF

보호계전기용 CT의 여자특성 자동측정 시스템 개발 (Development of an Automatic Excitation Characteristics Measurement System of the Protective Relaying CT)

  • 권성원;김문석;김재영;이성하;정재갑
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.868-869
    • /
    • 2008
  • An automatic excitation characteristics measurement system for the protective relaying current transformer(CT) with accuracy of about 1 % has been developed. The system can be used up to 2 kV and 10 A at power frequency. The developed system can calculate the voltage and current at knee points of $30^{\circ}$ and $45^{\circ}$ tangents in accordance with IEEE standard by the interpolation in log scale. The excitation curve of the CT is plotted in auto-scale simultaneously with measuring rms voltage and current at the secondary of the CT.

  • PDF

상용변압기와 결합된 초전도체 및 상전도체 한류기의 고장전류 및 보호기기 동작특성 (Characteristics of the Fault Current and the Protection for Superconducting and Normal Conducting Limiter combined with a Transformer)

  • 임인규;최효상;정병익
    • 전기학회논문지
    • /
    • 제62권9호
    • /
    • pp.1313-1317
    • /
    • 2013
  • With increasing demand of power, the equipment of power system is enlarging and the absolute capacity is going up. As a result, when a fault occurs, the fault current is consistently increasing. Therefore, I suggested some solution for limiting the fault current more efficiently. This study shows the characteristics of superconducting limiting elements and normal conducting elements combined with a transformer. We performed a short-circuit test about the fault current by using SCR switching control system operated from a CT. When short circuit accidents happened in the secondary side of a transformer, fault currents flowed and a SCR switching control system was operated. It resulted in a decrease of the fault current in the limited elements of third winding connected in parallel. For this test, we used YBCO thin films and normal conducting elements as the limited elements. Within a cycle, a superconducting fault current limiter with YBCO thin films reduced more than 90% of fault current because the resistance of superconducting elements sustainedly grew. On the other hand, the limiter with normal conductors limited as much as a set value because its resistance characteristic was linear. Consequently, in case of the limiter with superconductor, limiting range of the circuit was wide but the range of protective detection was undefined. In contrast, as for the limiter with normal conductors, limiting range and protection duty were appropriate.

DSP를 이용한 변류기 보상 알고리즘 (CT compensating algorithm Based on a Digital Signal Processor)

  • 강용철;이병은;소순홍;황태근;이지훈;차선희;김연희;장성일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.255-257
    • /
    • 2005
  • This paper proposes a compensating algorithm of a measurement torrent transformer (CT) using DSP. The core flux is calculated and then magnetizing current is estimated in accordance with the flux-magnetizing current curve. The core loss current is obtained with the core loss resistance and the secondary voltage. The correct secondary current is estimated by adding the exciting current to the measured secondary current. The performance of the proposed algorithm was tested using EMTP generated data. The experiment on the real CT was conducted using the prototype compensated system based on a digital signal processor. The results indicate that the algorithm can increase the accuracy of the measurement CT significantly.

  • PDF

변류기 2차전류의 포화 여부 판단 알고리즘 (An Algorithm for Detecting CT Saturation)

  • 강용철;옥승훈;강상희
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권6호
    • /
    • pp.275-278
    • /
    • 2001
  • This paper presents an algorithm for detecting current transformer (CT) saturation. At the instants of beginning (or end) of saturation, as a magnetizing inductance of the core is changed significantly, the shapes of the secondary current are also changed significantly though secondary currents are continuous the instants. At the instants, the second-order of third-order difference of the secondary current has big values. Thus, the third difference of the current is used to detect the beginning/end of CT saturation in this paper. If the magnitude of third-order difference of the secondary current is larger than a threshold value, the CT begins of ends saturation at the instants. The proposed detection method is unaffected by the amount of residual flux. The results of various tests with residual flux from -80% to +80% indicate satisfactory performance of the method.

  • PDF

영산변류기 동작 방식을 이용한 2개의 컨버터 병렬 운전 (Parallel Operation of Two Converters using Zero Current Transformer Method)

  • 송승찬;성제진
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권4호
    • /
    • pp.256-264
    • /
    • 2000
  • In the conventional method, two CTs have been used to share the load current equally with two converters. A new simle method to find out the current difference between two converters using only one CT as a ZCT is suggested. Two experimental prototype converters were designed and implemented for the evaluation of the load current sharing. The results of experiment show that the newly proposed ZCT method using only one CT could make a good load current sharing than the conventional method required two CT when operating two converters in parallel.

  • PDF

변류기를 이용한 자가발전 장치의 설계와 특성 (Design and Properties of a Self Generation Equipment using Current Transformer)

  • 변우봉;김현식;김종령;이해연;이준희;지민권;이진;오영우
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.427-428
    • /
    • 2008
  • We have studied design and application about an self generation equipment for underground power transmission cable. The split CT(Current Transformer), which has the applicable underground power transmission cable, was manufactured through electromagnetic simulation of magnetic core. And manufactured the AC-DC converter that supplied stable DC power for PLC modem when current of power line has more than 150A. An self generation equipment using the CT and AC-DC converter get into operation the PLC modem consistently. As a result, the underground power transmission cable was showed the application possibility through the stable communication and network characteristics.

  • PDF