• Title/Summary/Keyword: Current transformer

Search Result 1,366, Processing Time 0.027 seconds

A Study on the Diagnosis Method of Transformers Using Multi-channel Wireless Communication Network (다채널 무선 통신망을 이용한 변압기 진단 기법에 관한 연구)

  • Kim, Dong-Hyun;Choi, Joon-Ho;Moon, Jong-Fil;Kim, Jae-Chul;Yun, Yong-Han;Jeong, Yeon-Hae
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.461-463
    • /
    • 2000
  • As increasing the accident of distribution transformers, we need to manage them efficiently. This paper proposes the method for transformer's management using multi-channel wireless data communication. The Data Acquisition System(DAS) was developed to manage transformers and the HDLC protocol applied to the system. Additionally, it will be feasible to diagnose distribution transformers by checking load conditions such as hot spot temperature, ambient temperature, load current, etc. and using adequate algorithm.

  • PDF

Commercial Tool Based Modeling and Simulation Analysis of a Grid-Connected for 120kW Photovoltaic Generation System (상용툴을 이용한 120kW급 계통연계형 태양광발전시스템의 모델링 및 모의 해석)

  • Hwang, J.H.;Ahn, K.S.;Kim, Y.S.;Lim, H.C.;Oh, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.519-520
    • /
    • 2006
  • In this paper, to evaluate the grid-connected 120kW class Photovoltaic(PV) system performance, as a consisted of solar cells, PCS, 150kVA transformer station. The paper address modeling and analysis of a grid-connected 120kW class photovoltaic generation system(PV system) PSCAD/EMTD and Psim. A PWM voltage source inverter(VIS) and its current control scheme have been implemented. A P&O(Perturbation and Observation) MPPT algorithms technique modeling has been simulated and analysed.

  • PDF

Isolated PFC Converter Based on an ADAB Structure with Harmonic Modulation for EV Chargers

  • Choi, Seung-Won;Kim, Yoon-Jae;Lee, Il-Oun;Lee, Jun-Young
    • Journal of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.383-394
    • /
    • 2018
  • This paper presents an isolated power factor correction converter for general-purpose electric vehicle chargers with a wide output voltage range. The converter is based on an asymmetrical dual active bridge structure so that the voltage stress of switching devices can be eliminated by transferring the transformer leakage inductance to the circuit parameters. Harmonic and output controls are performed by secondary switches, and primary switches are only operated at a fixed frequency with a 50% duty ratio. A harmonic modulation technique is also adopted to obtain a near-unity power factor without input current monitoring. The feasibility of the proposed charger is verified with a 3.3 kW prototype.

Parallel Operation of Trans-Z-Source Network Full-Bridge DC-DC Converter for Wide Input Voltage Range

  • Lee, Hyeong-Min;Kim, Heung-Geun;Cha, Hon-Nyong
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.2
    • /
    • pp.98-104
    • /
    • 2012
  • This paper presents a novel transformer isolated parallel connected full-bridge dc-dc converter using recently developed trans-Z-source network. Unlike the traditional voltage -fed or current-fed converters, the proposed converter can be open- and short-circuited without damaging switching devices. Therefore, the desired buck and boost function can be achieved and the converter reliability can be greatly improved. A 6 kW prototype dc-dc converter is built and tested to verify performances of the proposed converter.

A Development of Measurement System for Diathesis-Diagnosis (체질 진단을 위한 센서 시스템의 개발)

  • Jung, Yong-Rae;Kim, Seong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.260-263
    • /
    • 2001
  • This paper is to develop the sensing system for opening-force measurement such as O-Ring muscular meridian. We designed to overcome the functional limit that the conventional force-sensor can measure just the closing-force. Therefore, the new sensor can meet a variety of application as well as O-Ring test. The structure of the new sensor is an actuator-type system using an electromagnet. That is made up of mechanical system, electromagnet, current transformer and computer interface circuit. Driving software and user interface program of the new sensor system also is explained in this paper.

  • PDF

Characteristics of RFCT for Partial Discharge Measurement in the Stator Winding of Rotating Machines (회전기 고정자 권선의 부분방전 측정용 RFCT 특성)

  • Kang, Dong-Sik;Yoon, Dae-Hee;Hwang, Don-Ha;Kim, Yong-Joo;Chang, Ki-Chan;Song, Sang-Ock
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1616-1618
    • /
    • 2001
  • In recent the on-line partial discharge (PD) measurement using sensors, such as EMC, SSC, RTD and RFCT, as an indicator of stator winding insulation condition has been developed. RFCT sensor was placed arounding a grounding lead of surge capacitor to detecting PD. Trend of PD magnitude/phase angle/pulse number over time are useful parameter to diagnosis aging state. We have developed Radio Frequency Current Transformer(RFCT) sensor which is suitable for PD diagnostic measurement in 6.6kV rotating machines. In this paper, we describe the characteristics of RFCT sensor, such as frequency and PD magnitude using 6.6 kV model stator winding in Lab.

  • PDF

The Effect of Interface Activation Substances in Reduction Phenomena of Streaming Electrification for Transformer Oil (변압기유의 유동대전 감소현상에 미치는 계면활성제의 효과)

  • Kim, Yong-Woon;Lee, Duck-Chool;Watanabe, Shigeo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07e
    • /
    • pp.48-51
    • /
    • 2000
  • The purpose of this study is to find the way to reduce the electrostatics by interface activation substances added in the insulating oil with concentration[ppm]. As results, The streaming current, surface tension and viscosity of the samples added nonionic and hermaphrodic substances are decreased but the conductivity is increased at higher point than the 1[ppm](c.m.c.), the other side the same phenomena of the samples added cationic and anionic substances are discovered at the 10[ppm].

  • PDF

A Study on Synthetic Failure-finding Method for Electrical and Thermal Degradation of Polymer Insulator by Surface Discharge

  • Lee, Kang-Won;Jang, Dong-Uk;Park, Cheol-Hyun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.3
    • /
    • pp.143-146
    • /
    • 2007
  • Polymer insulators are used widely in variable fields for high voltage insulation and separating people from high voltage charging parts for safety and also supporting overhead power line in electric railway. But it may be broken down by tracking path resulting from continuous surface discharge. This paper has investigated synthetically both the characteristics of electrical aging using precision CT(current transformer) and the thermal aging using thermography method. Electrical aging was analyzed for time-frequency region and thermal aging was illustrated by image processing method. This synthetic method may be an appropriate one to evaluate the surface degradation of polymer insulator.

Modeling of inductive power collector for PRT system (PRT 시스템에 적합한 유도 전력 집전 장치의 모델링)

  • Han Kyung-Hee;Lee Byung-Song
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.794-799
    • /
    • 2005
  • In this paper, the inductive power collector using electromagnetic induction for the PRT(Personal Rapid Transit) system is suggested and some ideas for power collector design to improve the power transfer performance are presented. The proposed the inductive power collector is used for the PRT system, which has a large air-gap and demands a large electrical power capability. But, low output power is generated due to a loosely coupled characteristic of the large air-gap. Therefore, double layer construction of secondary winding. which was divided in half to increase both output current and output voltage was suggested. Also, model of power collector and parallel winding structure are presented, in addition, the performance of inductive power collector to alignment condition between the primary power line and the inductive power transformer was verified by computer simulation of 2kW model.

  • PDF

A Study of PBD and BD Voltage Characteristics in the Simulate Electrode System of Solenoid Type High Temperature Superconducting Coils (솔레노이드형 고온초전도코일 모의전극계에서 부분 및 완전파괴전압특성 연구)

  • 석복렬
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.94-98
    • /
    • 2002
  • The Partial breakdown (PBD) and complete breakdown (BD) voltage characteristics in a composite insulation system of glass fiber reinforced plastics (GFRP) and liquid nitrogen are investigated to find the PBB and BD characteristics in solenoid type high temperature superconducting (HTS) coils at quench. The electrode system used is made from a coaxial spiral coil-to-cylindrical electrode with an insulation barrier and spacers, and is immersed in liquid nitrogen. A heater is mounted inside the coil electrode to generate boiling which occurs on quenched superconducting coils. The experimental results show that: (1) breakdown voltages are affected severely by the risetime of the applied voltage and the PBD inception voltage, (2) two kinds of BD mechanisms are found depending on the shape of the spacer, length of cooling channel and heater power.