• Title/Summary/Keyword: Current test

Search Result 7,171, Processing Time 0.036 seconds

반도체 소자의 DC 특성 검사를 위한 DC parameter test 회로설계에 관한 연구

  • 이상신;전병준;김준식
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2003.05a
    • /
    • pp.51-54
    • /
    • 2003
  • 반도체 산업의 발전에 따라 생산과정에서의 반도체 소자의 특성을 검사하고, 오류를 검출하는 작업을 효율성 있게 하여 생산성을 향상시키는 것이 더욱 중요시 되고 있다. 이러한 흐름에 맞추어 반도체 test장비에 VFCS(voltage forcing current sensing)와 CFVS(current forcing voltage sensing)를 test 할 수 있게 개발하였다.

  • PDF

A Study of Optimizing Cathodic Protection in Comparison of Design Methodologies

  • Choi, Young-Kwan;Choi, Sang-Yule;Shin, Myong-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.11
    • /
    • pp.23-29
    • /
    • 2010
  • The principal factor determining an optimum design method for cathodic protection is finding the protection current for preventing the corrosion of existing, already laid pipe. Some factors currently used to test designs include the sizes and lengths of pipes, soil resistivity, and the coating damage rate. We believe this method and current formulae are not optimum due to the uncertainty of determining the coating damage rate and the corrosion protection current's density. This paper analyzes the amount of protection current obtained by performing a temporary current test using data describing existing laid pipe. We then propose determining the corrosion protection current by using the temporary current test after modifying the formula. In addition, we suggest a way to choose optimized cathodic protection and the process of design by executing the design and taking account of such factors as a site condition of 34km-long non-protected water supply pipe lines (stages I and II) in ${\bigcirc}{\bigcirc}$ region, climate, interferences, and durability.

HEMP Effect Analysis for Equipment Using Comparison of Norms between HEMP Filter Residual Current and Conducted Susceptibility Criteria (HEMP 필터 잔류 전류와 전도 내성 기준의 특성인자 비교를 통한 장비의 HEMP 영향성 분석)

  • Kwon, Joon-Hyuck;Song, Ki-Hwan;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.2
    • /
    • pp.199-207
    • /
    • 2014
  • Although High-altitude electromagnetic pulse(HEMP) protection filter meets the requirements of pulsed current injection(PCI) acceptance test, the equipment under test which has low electromagnetic susceptibility level can be damaged during PCI verification test that is performed on operating condition of equipment. This paper proposed the HEMP effect analysis method using comparison of norms between residual current of HEMP filter and transient electromagnetic conducted susceptibility criteria of equipment, as an alternative method under the condition that performing PCI verification test is limited in HEMP hardened facilities. PCI acceptance test of HEMP filter, transient electromagnetic conducted susceptibility test, and PCI verification test are performed and test results are analyzed.

A Study on the Improvement of ZnO Varistor for Distribution Class Surge Arrester(18kV, 5kA) (배전급 피뢰기(18kV, 5kA)용 산화아연바리스타의 성능향상에 관한 연구)

  • Yoo, Deok-Son;Yoon, Han-Soo;Kim, Suk-Soo;Choi, Yeon-Gyu;Jang, Sung-Do
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.744-746
    • /
    • 2003
  • A ZnO varistor with reference voltage 250V/mm was fabricated through the control of particle size in slurry and the variation of sintering conditions. It was found that to measure the flatness of the V-I characteristic curve in the small-current region and the flatness of the V-I characteristic curve in a large-current region was improved nonlinearity of the fabricated ZnO varistor. According to the IEC 60099-4 was measured the accelerated aging test and high current test of the distribution class surge varistor which is excellent in respect to the property of ZnO varistor.

  • PDF

Comparison of Small Current Interruption Capability Depending on the Type of Interrupter (차단부 형태에 따른 소전류 차단성능 비교)

  • Song, Ki-Dong;Chong, Jin-Kyo;Kim, Hong-Kyu
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.7
    • /
    • pp.362-368
    • /
    • 2006
  • This paper presents the results of a small capacitive current interruption test for the three types of interrupter which are called 'serial type', 'parallel/separated type' and 'puffer type' according to the arrangement of the thermal expansion chamber and the puffer cylinder. After the preconditioning test the small current interruption capability of the 'puffer type' decreased, on the contrary, that of the hybrid interrupters increased. A number of reignition have been occurred in the 'serial type' hybrid interrupter and the change of small current interruption capability after preconditioning test is mainly influenced by the structure of interrupter. Finally it has been proved that the 'parallel/separated type' hybrid interrupter has the best interruption performance through the verification tests.

A Development of the Algorithm to Detect the Fault of the Induction Motor Using Motor Current Signature Analysis (전류분석을 이용한 유도 전동기의 결함분석 알고리듬 개발)

  • 신대철;정병훈
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.8
    • /
    • pp.675-683
    • /
    • 2004
  • The motor current signature provides an important source of the information for the faults diagnosis of three-phase induction motor. The theoretical principles behind the generation of unique signal characteristics, which are indicative of failure mechanisms, are Presented. The fault detection techniques that can be used to diagnose mechanical Problems, stator and rotor winding failure mechanisms, and air-gap eccentricity are described. A theoretical analysis is presented which predicts the presence of unique signature patterns in the current that are only characteristics of the fault. The predictions are verified by experimental results from a special fault Producing test rig and on-site tests in a steel company. And this study have made new diagnostic algorithm for the operating induction motors with the test results. These developments are including the use of monitoring and analysis of electric current to diagnose mechanical and electrical problems and gave the precise test results automatically.

Design of a Built-In Current Sensor for CMOS IC Testing (CMOS 집적회로의 테스팅을 위한 새로운 내장형 전류감지 회로의 설계)

  • Hong, Seung-Ho;Kim, Jeong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2003.11b
    • /
    • pp.271-274
    • /
    • 2003
  • This paper presents a Built-in Current Sensor that detect defects in CMOS integrated circuits using the current testing technique. This scheme employs a cross-coupled connected PMOS transistors, it is used as a current comparator. Our proposed scheme is a negligible impart on the performance of the circuit undo. test (CUT). In addition, in the normal mode of the CUT not dissipation extra power, high speed detection time and applicable deep submicron process. The validity and effectiveness are verified through the HSPICE simulation on circuits with defects. The entire area of the test chip is $116{\times}65{\mu}m^2$. The BICS occupies only $41{\times}17{\mu}m^2$ of area in the test chip. The area overhead of a BICS versus the entire chip is about 9.2%. The chip was fabricated with Hynix $0.35{\mu}m$ 2-poly 4-metal N-well CMOS technology.

  • PDF

The transient grounding impedance measurment of large grid grounding electrodes (대규모 그리드 접지전극의 과도접지임피던스의 측정)

  • Jeon, Byung-Wook;Lee, Su-Bong;Li, Feng;Lee, Seung-Ju;Jung, Dong-Cheol;Lee, Bok-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.69-72
    • /
    • 2008
  • This paper presents the transient and conventional grounding impedance behaviors of large grid grounding system associated with the injection point of impulse current The measurement methods consider two possible errors in the grounding-system impedances: (1) ground mutual resistance due to current flow through ground from the ground electrode to be measured to the current auxiliary, (2) ac mutual coupling between the current test lead and the potential test lead The test circuit was set to reduce the error factors. The transient grounding impedance depends on the rise time and injection point of impulse current It is effective that grounding conductor is connected to the center of the large grid grounding system.

  • PDF

The Inductance Computation of IPMSM using Current Vector Control Test (전류벡터제어시험법에 의한 IPMSM의 인덕턴스 산정)

  • Cho, Gyu-Won;Lee, Jung-Gyu;Kim, Gyu-Tak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1807-1812
    • /
    • 2012
  • In this paper, the d, q-axis inductance of IPMSM(Interior Permanent Magnet Synchronous Motor) was calculated by the FEA(Finite Element Analysis). And the CVCT(Current Vector Control Test) was performed, and compared with FEA. Therefore the inductance experiment according to the variation of the current phase angle was performed. However, the error was generated in the fundamental wave detection of the voltage and current waveform. So, error has largely effect on the result of computation, it has to note specially. In addition, by using the calculated inductance, the torque calculation was performed and this result was compared through the dynamometer experiment.

Evaluation of Long Duration Current Impulse Withstand Characteristics of ZnO Blocks for High Voltage Surge Arresters (초고압 피뢰기용 ZnO 소자의 장시간 방전내량 특성 평가)

  • Cho, Han-Goo;Yun, Han-Soo;Kim, Seok-Soo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.4
    • /
    • pp.398-403
    • /
    • 2006
  • This paper describes the evaluation of the long duration current impulse withstand characteristics of ZnO blocks for high voltage surge arresters. Four ZnO varistors were manufactured with the general ceramic production method and the long duration current impulse withstand test, electrical uniformity evaluation test and microstructure observation were performed. All varistors exhibited high density, which was in the range of $5.42{\sim}5.46g/cm^3$. In the electrical properties, the reference voltage of samples was in the range of $5.11{\sim}5.25\;kV$ and the residual voltage was in the range of $8.314{\sim}8.523\;kV$. In the long duration current impulse withstand test, sample No.2 and No.3 failed at the 2nd and 4th shot of series impulse currents, respectively, but the rest survived 18 shots during the test. Before and after this test, the variation ratio of the residual voltage of samples survived was below 0.5 %, which was in the acceptance range of 5 %. According to the results of the test, it is thought that if the soldering method is improved, ZnO varistors would be possible to apply to the high voltage arresters like the station class and transmission line arresters in the near future.