• Title/Summary/Keyword: Current test

Search Result 7,143, Processing Time 0.038 seconds

Fabrication and Performance test of HTS current lead part of 3MJ SMES (3MJ급 SMES용 HTS 전류리드부의 제작 및 성능평가)

  • 심기덕;조전욱;김해종;배준한;김해준;성기철
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.7-9
    • /
    • 2003
  • A 3MJ class SMES was fabricated last year. And 1000A class current part for the SMES also was designed, fabricated and tested. The current lead was made of metal part(brass) and HTS lead Part. The lead is located in vacuum vessel and cooled down to belows the HTS lead's operating temperature. We made three types of current lead part and tested their performance. In this paper, the basic and conceptual type of current lead will be introduced. The lead was expected to have 1000A current capacity. But the test results was only 480A. After this test, based on the results we revised the shape of the lead and improved the connectivity between cryocooler and lead. In this paper, the design procedure and the results of performance test will be introduced.

  • PDF

Investigation of Large-scale Transmission Tower Grounding Grid with High Amplitude and Uniform Flowing Impulse Current

  • Yang, Shuai;Huang, Jiarui;Wei, Shaodong;Zhou, Wenjun
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.2050-2058
    • /
    • 2018
  • Impulse characteristic of transmission tower grounding grid is needed for lightning protection of transmission line. This paper describes an outdoor experimental test facility established for large-scale grounding grid of transmission tower, made up of four impulse current generators and a circle current return electrode. The amplitude of impulse current is up to 100 kA. The results of the CDEGS simulation and GPR measurement reveal the uniform current distribution in the test arrangement. An impulse test for a square electrode with extended conductors is carried out in condition of three current waveforms with different amplitude. Based on the electrical network model and iterative algorithm method, a calculation model is proposed to simulate the impulse characteristic of large-scale grounding grid considering soil ionization. The curve of impulse resistance against the current amplitude shows the soil ionization both from the simulation and test. Deviation between the simulation and test result is less than 15%.

Design of a Built-In Current Sensor for IDDQ Testing (IDDQ 테스팅을 위한 내장형 전류 감지 회로 설계)

  • Kim, Jeong-Beom;Hong, Sung-Je;Kim, Jong
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.8
    • /
    • pp.49-63
    • /
    • 1997
  • This paper presents a current sensor that detects defects in CMOS integrated circuits using the current testing technique. The current sensor is built in a CMOS integrated circuit to test an abnormal current. The proposed circuit has a very small impact on the performance of the circuit under test during the normal mode. In the testing mode, the proposed circuit detects the abnormal current caused by permanent manufacturing defects and determines whether the circuit under test is defect-free or not. The proposed current sensor is simple and requires no external voltage and current sources. Hence, the circuit has less area and performance degradation, and is more efficient than any previous works. The validity and effectiveness are verified through the HSPICE simulation on circuits with defects.

  • PDF

Change of the Microstructure of ZnO Arrester block by Lightning Surge Current and Ageing test (뇌서지전류와 Ageing에 의한 산화아연형 피뢰기 소자의 미세구조변화)

  • Lee, Bok-Hee;Kang, Sung-Man
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1877-1879
    • /
    • 2000
  • This paper deals with the change of the micro-structure of ZnO associated with lightning surge current and ageing test. In this work, a surge current generator which can produce 8/20 [${\mu}s$], 6 [kA] impulse current is designed and fabricated to simulate the lightning impulse current. The residual voltage and leakage current flowing to ZnO blocks are observed. Also a compensation circuit was used in resistive current measurement. The micro-structures of ZnO arrester block were significantly changed by lightning surge current and accelerated temperature ageing test.

  • PDF

ACSR Inner Corrosion Detection by Eddy Current Test Method (ACSR 가공지선의 부식 검출에 관한 연구)

  • Kang, Ji-Won;Jeong, Jae-Kee;Kang, Yeon-Woog;Kim, Jeong-Boo
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1935-1937
    • /
    • 1996
  • This paper deals with ACSR(Aluminum Conductor Steel Reinforced) inner corrosion detection using a detector which automatically runs on an ACSR transmission line and inspects the inner corrosion of the conductor by utilization of the nondestructive eddy current test. And the relationship between the corrosion grades and the tensile strength can be estimated by means of this test. According to corrosion appearance and development of ACSR, the impedance change of the eddy current coils is theoretically verified. And then specifications And performances of the detector are described. Experimental procedures and desirable test results are reported. In conclusion, this detector can realize the nondestructive detecting of an ACSR inner corrosion. Upgrading the maintenance effciency and improving the reliability of transmission line would be expected by this nondestructive test method.

  • PDF

A Study on Permissible Current of Low Impedance Cable (저임피던스 케이블의 허용전류에 대한 연구)

  • 김동식;박복기;이종찬;이관우;박대희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.513-515
    • /
    • 1999
  • In this study, we evaluated the relation of the test and theory of low impedance cable As the result We could obtained the result in accordance the test with theory in 85 ~ 95% tolerance . Test method measured the relation of the current and temperature of cable jacket in using CT to put in 3 phase AC current simultationiously. The current and temperature of it was calculated in according to JCS- l68D

  • PDF

The Study of the Verification Test for Development of Contacts(50kA) of Making Switch and Back Up Breaker (대용량(50kA)의 Making Switch와 Back Up Breaker 접점 개발에 따른 검증시험의 연구)

  • Kim Sun-Koo;Kim Won-Man;La Dae-Ryeol;Roh Chang-Il;Lee Dong-Jun;Jung Heung-Soo
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.842-844
    • /
    • 2004
  • The Back Up Breaker and Making Switch are very important equipments for the short circuit test facility, and contacts are the most important parts of the above switches. There are very many kind of contacts according to switches characteristic and should be done the verification test before use, especially development contacts. This study describes the class of switches, arc chute, material of whole contacts and essential test for verification. The essential test for verification are dielectric test, mechanical operation test, short-time withstand current test, load current breaking test, and short-circuit making current test etc.

  • PDF

A Study on Failure Analysis of Low Voltage Breakers with Aging (경년열화에 따른 배선용 차단기류의 고장점 분석 연구)

  • Cho, Han-Goo;Lee, Un-Yong;Lee, You-Jung;Lee, Hae-Ki;Kang, Seong-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.501-502
    • /
    • 2006
  • In this paper, new and aging sample of MCCB and ELCB are investigated the main performance test such as short circuit test, mechanical and electrical endurance test, dielectric test and surge current test. The surface conditions of new and aging sample are analyzed by SEM, TGA and DSC. The ELCB occurred badness mainly in short circuit test and surge current test. The badness cause of short circuit test was confirmed due to imperfect contact of contact part.

  • PDF

Evaluation of Springback Angle Change with Applying Electric Current After V-bending Test on AZX311 Magnesium Alloy and Martensitic Steel (AZX311 마그네슘 합금과 마르텐사이트 강의 V-bending 이후 전류 인가에 따른 스프링백 각도 변화 평가)

  • Park, J.W.;Jeong, H.J.;Jin, S.W.;Kim, M.J.;Kim, J.J.;Han, H.N.
    • Transactions of Materials Processing
    • /
    • v.27 no.3
    • /
    • pp.177-183
    • /
    • 2018
  • The influence of electric current on the springback characteristics of AZX311 magnesium alloy and martensitic steel after V-bending test is investigated. Various pulsed electric currents are applied into the specimens followed by a V-bending test, and the changes in the springback angle are measured. In order to evaluate not only the thermal effect but also the athermal effect of electric current on the springback angle, the temperature rises resulting from the applied electric current are measured for all test conditions. As a result, it was found that the springback is significantly decreased as the current density increases. As for the martensitic steel, since the dislocation recovery immoderately occurs at a high electric current density condition of $80A/mm^2$, the optimal current density condition should be required.

Fabrication and Test of a Superconducting Coil for SMES (SMES용 초전도코일 제작 및 특성)

  • 김해종;성기철;조전욱;배준한;김석환;심기덕;이언용;권영길;류경우
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.11
    • /
    • pp.557-562
    • /
    • 2003
  • To develop a stable and compact small-sized superconducting magnetic energy storage (SMES) system, which provides electric power with high quality to sensitive electric loads, we fabricated a SMES coil and tested it. Because such a large-sized superconducting coil quenches far away from its critical current, the recovery current is frequently used as a stability criterion in the coil fabrication. Therefore, we first investigated the recovery current characteristics of the large current conductor, which was used in our SMES coil fabrication. The test results indicate that the recovery currents measured in the conductor are nearly identical to those based on the single wire. This implies that the recovery current is affected by the conductor's cooling condition rather than its size and current capacity. In the SMES coil test the first quench occurred at 1250 A, which is equivalent to the stored energy of about 2 MJ. It corresponds to the quench current density of about $130A/mm^2$ This value is much higher in comparison with that reported in the other work. In addition, the first quench current of the coil agrees well with the measured recovery current of the conductor having similar cooling condition with it. This means that to determine the recovery current of a conductor is, first of all, important in the design and fabrication of a large-sized superconducting coil.