• Title/Summary/Keyword: Current leads

Search Result 874, Processing Time 0.049 seconds

An effect of rail accumulated passing tonnage measurement device which uses a optical fiber sensor rail pad (광섬유센서 레일패드를 이용한 레일누적통과톤수 실측장치의 효용성 분석)

  • Shin, Hyo-Jeong;Park, Eun-Yong;Kong, Sun-Yong;Kim, Bag-Jin
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.91-98
    • /
    • 2009
  • For maintaining railroad, accumulated passing tonnage is a determinant factor of appropriate rail replacement time. Recently, Seoul Metro's rail maintaining system and technology is being improved from previous years, which increasing a standard of rail replacement. Thus, this brings importance of estimating and managing for accumulated passing tonnage. In case of light weighted train such as subway, current method of calculating accumulated passing tonnage has defaults of misrepresenting accumulated passing tonnage data. Because current method is based on the weight of passengers and train., and operation data. In addition, currently there is no mechanical and electronic system that could represent and support the accurate data between heavy and non-heavy traffic area, and accumulated passing tonnage is calculated inaccurately by estimating average value each line. The current method of calculating accumulated passing tonnage misleads to unpredictable data that represent inappropriate rail replacement period, which leads to under or over analyzed replacement period. If accumulated passing tonnage is over estimated, rail replacement leads to waste of budget. Hence, it is necessary to construct reliable actual measurement system to manage rail's life safely and efficiently, and in this study the accumulated passing tonnage measurement device is installed with using rail pad of optical fiber sensors and its effect is analyzed.

  • PDF

A Rotating Flux Pump Employing a Magnetic Circuit and a Stabilized Coated Conductor HTS Stator

  • Jiang, Z.;Bumby, C.W.;Badcock, R.A.;Long, N.J.;Sung, H.J.;Park, M.
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.239-243
    • /
    • 2016
  • High temperature superconductor (HTS) magnet systems usually employ metal current leads which bridge between the cryogenic environment and room temperature. Such current leads are the dominant heat load for these magnet systems due to a combination of electrical resistance and heat conduction. HTS flux pumps enable large currents to be injected into a HTS magnet circuit without this heat load. We present results from an axial-type HTS mechanically rotating flux pump which employs a ferromagnetic circuit and a Cu-stabilized coated conductor (CC) HTS stator. We show the device can be described by a simple circuit model which was previously used to describe barrel-type flux pumps, where the model comprises an internal resistance due to dynamic resistance and a DC voltage source. Unlike previously reported devices, we show the internal resistance and DC voltage in the flux pump are not exactly proportional to frequency, and we ascribe this to the presence of eddy currents. We also show that this axial-type flux pump has superior current injection capability over barrel-type flux pumps which do not incorporate a magnetic circuit.

Optimal design of Current lead considering Natural convection (자연대류를 고려한 전류도입선의 최적설계)

  • Son, B.J.;Seol, S.Y.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.103-108
    • /
    • 2003
  • In this paper, the current lead for superconducting device is studied by numerical method. The current lead is cooled by surrounded $N_{2}$ gas by natural convection. The heat conduction equation for current lead and boundary layer equation for $N_{2}$ gas must be solved simultaneously. The boundary layer equation for $N_{2}$ gas is highly nonlinear for varied temperature of current lead. So the linearization method is adopted for simplicity. Numerical results using natural convection cooling are compared with the conventional cooling methods such as conduction cooling and vapor cooling methods. The main difference of natural convection cooing is the non-zero temperature gradient at the top of current lead for the minimum heat dissipation into superconducting devices. For the optimized conduction-cooling and vapor-cooling current leads, the temperature gradient at the top of current lead is zero. Also, the heat flow at the cold end is much smaller than conduction cooling case.

  • PDF

Fabrication of BSCCO high-Tc superconducting current lead (BSCCO 고온초전도 전류도입선의 제조)

  • 하동우;오상수;류강식;장현만
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.252-255
    • /
    • 1996
  • Superconducting current lead is one of the promising applications of the oxide high-Tc superconductors, because they have the advantage of decreasing heat conduction to low temperature region, comparing with a conventional cooper alloy lead. High critical current density is a key factor for the applications such as current lead. (Bi,Pb)$_2$Sr$_2$Ca$_2$Cu$_3$O$\_$x/ high Tc superconductor haute been investigated in terms of critical current density. Bi-2223 superconducting current lead made by CIP and solid state sintering process. Bi-2223 current lead that heat treated at 836$^{\circ}C$ for 240 h in 1/13 P$\_$O$_2$/ had over 150 A/$\textrm{cm}^2$ of critical current density at 77K. We knew that the superconducting properties of tube type current leads were better than rods type of them. And we investigated the relation of Bi-2223 formation and heat treatment condition by XRD and SEM analysis.

  • PDF

Characteristics of Bi-based High $T_c$ Superconducting Current Lead (Bi계 고온초전도 전류 리드의 특성)

  • 백승명;이병성;김영석;곽민환;김상현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.73-76
    • /
    • 1999
  • We have fabricated and tested a Bi-based high temperature superconducting current lead system. Ag sheathed Bi-2223 mono-filament tapes of $I_c=8.4$ A at 77 K under self-field condition were fabricated using powder-in-tube(P1T) method. Multi-layer current leads can be made by stacking of Ag sheathed Bi-2223 mono-filament wires. The critical current of this 10-layer current lead is about 68 A. The contact resistance across the copper-current lead interface has been studied using current-voltage characteristics. At temperature below critical temperature the resistive contribution of the interface to the total contact resistance dominates. We have measured AC transport losses in a current lead at 77 K, 60 Hz by a transport method.

  • PDF

Influence of Current Distributions on Critical Current Characteristics in a 3-conductor (전류분포가 3본-도체의 임계전류 특성에 미치는 영향)

  • Jo, Young-Ho;Ryu, Kyung-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.792-794
    • /
    • 2003
  • AC loss is an important issue in the design of high-$T_c$ superconducting power cables which consist of a number of Bi-2223 tapes wound on a former. In the cables, the tapes have different critical currents intrinsically. And they are electrically connected to each other and current leads. In this work we have prepared a conductor composed of three Bi-2223 tapes with different critical currents. The critical current characteristics in the conductor have experimentally investigated. The results show that for uniform current distributions the conductor's critical current is proportional to the critical current of the Bi-2223 tape to which a voltage lead is attached. However it depends on the current non-uniformity parameter in the conductor rather than the tape's critical currents for nonuniform current distributions.

  • PDF

Sustainable Luxury Fashion Consumption and the Moderating Role of Guilt

  • Ki, Chungwha;Kim, Youn-Kyung
    • Fashion, Industry and Education
    • /
    • v.14 no.1
    • /
    • pp.18-30
    • /
    • 2016
  • This study explores whether consumers' sustainable luxury purchase (SLP), which refers to luxury consumers' conscientious purchase behavior of "buying luxury for its timeless style and durable quality that leads to extended product usage and less waste," leads to luxury consumer pleasure (LCP). Furthermore, the current study examines whether LCP leads to positive post-purchase behavior reflected by sustainable divestment intention (SDI) and repurchase intention (RI). In addition, by building on Coping Theory, we explore whether luxury consumer guilt (LCG) positively moderates the relationship between LCP and SDI. Our empirical findings of the SEM analysis based on 452 valid responses demonstrate the significant relationships between SLP and LCP, between LCP and SDI, and between LCP and RI. This implies the importance of SLP in creating a favorable consumer response, which further leads to consumers' intentions to make a sustainable divestment and to repurchase luxury. Furthermore, the critical moderating role LCG plays in the relationship between LCP and SDI was supported, stressing the importance of guilt as a trigger of consumers' sustainable divestment behavior.

Reduction of Current Harmonic Occurred form between Uninterruptible Powers Supply and Rectifier Load (정류기 부하와 무정전전원장치 사이에 발생되는 Current Harmonic 저감)

  • 곽철훈;반한식;최규하;목형수
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.41-44
    • /
    • 1999
  • The main purpose of the UPS is to supply independent and stable power to connected equipment. In installing and operating the UPS system, songle module, three phase UPS in more benefit than multi module, songle phase UPS in the point of volume and cost. However, when supplying Rectifier with output power form three phase UPS, by connecting auto-transformer, occurred harmonic and ripple current makes output filter damaged and leads to nonlinear current coasted by unbalance load. Therefor, in this paper the aim of concentring compound-wound transformer and harmonic filter is supplying liner current by reducing harmonic and ripple current and improving unbalance in voltage and distortion in current wave.

  • PDF

Structure Design and Thermal Analysis of Cryogenic Cooling System for a 1500 A, 400 mH Class HTS DC Reactor (1500 A, 400 mH급 초전도 직류 리액터용 극저온 냉각 시스템 구조 설계 및 열 해석)

  • Quan, Dao-Van;Le, Tat-Thang;Sung, Hae-Jin;Park, Min-Won;Yu, In-Keun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.23 no.1
    • /
    • pp.31-41
    • /
    • 2018
  • This paper discusses a structure design and thermal analysis of cryogenic conduction cooling system for a high current HTS DC reactor. Dimensions of the conduction cooling system parts including HTS magnets, bobbin structures, current leads, support bars, and thermal exchangers were calculated and drawn using a 3D CAD program. A finite element method model was built for determining the optimal design parameters and analyzing the thermo-mechanical characteristics. The operating current and inductance of the reactor magnet were 1,500 A, 400 mH, respectively. The thermal load of the HTS DC reactor was analyzed for determining the cooling capacity of the cryo-cooler. Hence, we carried out the operating test of conduction cooling system of the 1st stage area with high current flow. The cooper bars was cooled down to 40 K and HTS leads operated stably. As a experiment result, the total heat load of the 1st stage area is 190 W. The study results can be effectively utilized for the design and fabrication of a commercial HTS DC reactor.

Gate Leakage Current Characteristics of GaAs MESFETS′ with different Temperature (GaAs MESFET의 온도변화에 다른 게이트 누설전류 특성)

  • 원창섭;김시한;안형근;한득영
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.50-53
    • /
    • 2001
  • In this study, gate leakage current mechanism has been analyzed for GaAs MESFET with different temperatures ranging from 27$^{\circ}C$ to 300$^{\circ}C$ . It is expected that the thermionic and field emission at the MS contact will dominate the current flow. Thermal cycle is applied to test the reliability of the device. From the results, it is proved that thermal stress gradually increases the gate leakage current at the same bias conditions and leads to the breakdown and failure mechanism which is critical in the field equipment. Finally the gate contact under the repeated thermal shock has been tested to check the quality of Schottky barrier and the current will be expressed in the analytical from to associate with the electrical characteristics of the device.

  • PDF