• Title/Summary/Keyword: Current harmonics

Search Result 897, Processing Time 0.022 seconds

Neutral Current Compensation Using Single Phase Active Power Filter in Three-Phase Four-Wire Electric Distribution Systems (3상 4선식 배전계통에서 단상 능동필터를 이용한 중성선 전류의 보상)

  • Choi, See-Young;Kim, Byung-Seob;Song, Jong-Hwhan
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1046-1048
    • /
    • 2002
  • The increase of triplen harmonics in three-phase four-wire systems leads to overloaded neutral conductor, common-mode noise problems, derating of transformers, and so on. Various compensator has been designed to prevent the problems associated with the triplen harmonics. But these can not protect distribution system effectively because the triplen harmonic source is distributed extensively and distribution system type is diverse. This paper explain the operation and installation of single phase active power filter to eliminate triplen harmonics and then it is verified by simulation.

  • PDF

A study on Active Power Filter Available for DC-Link Boost and Power Factor Control (DC전압 충전 및 전원 역률 보상이 가능한 APF에 관한 연구)

  • Lee, Woo-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.1
    • /
    • pp.53-60
    • /
    • 2013
  • In this paper, a control algorithm for active power filter (APF), which compensates for the harmonics and power factor, boosting the DC-link voltage is proposed. The proposed scheme employs a pulse-width-modulation (PWM) voltage-source inverter. A simple algorithm to detect the load current harmonics is also proposed. The APF and charging circuit are implemented in one inverter system. Finally, the validity of the proposed scheme is investigated with simulated and experimental results for a prototype APF system rated at 3kVA.

Comparison of Efficiency for Different Switching Tables in Six-Phase Induction Motor DTC Drive

  • Taheri, Asghar;Rahmati, Abdolreza;Kaboli, Shahriyar
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.128-135
    • /
    • 2012
  • In this paper, different switching tables proposed for the Direct Torque Controlled (DTC) of a six-phase induction machine are simulated and implemented. A six-phase induction motor has 64 space voltage vectors which result in increased complexity in the selecting of inverters switching. The unsuitable selection of a switching table leads to large harmonics especially at low speed and it also reduces drive efficiency. A six-phase induction machine has large zero sequence harmonic currents of the order $6{\kappa}{\pm}1$. These harmonic currents are varied in various techniques. Decreasing this loss is essential in a six-phase induction machine. The main purpose of this paper is to improve the ST-DTC of six-phase induction machines to reduce the voltage and current harmonics and the torque pulsation. Selecting a suitable method for minimizing these harmonics is very important.

New Controller for Power Factor and Harmonics Compensation of Single-Phase PWM Converter without AC Voltage Sensor (단상 PWM 컨버터의 역률 및 고조파 보상을 위한 교류전압 검출기가 없는 새로운 제어기)

  • Jon, Y.S.;Baek, S.T.;Kim, H.J.;Han, B.M.
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.161-165
    • /
    • 2003
  • In this paper, A new controller for power factor and harmonics compensation of a single-phase PWM converter is described. The proposed controller requires only the dc voltage sensor and the at current sensor to compensate the power factor and harmonics. Detail simulation model with EMTBC (Electro-Magnetic Transient program for DC transmission) including power circuit and controller was developed to verify the operation of proposed controller. The application feasibility of the proposed controller was verified through experimental works with a prototype. The proposed controller has a simple structure in the point of hardware implementation, and shows excellent performance in normal operation as well as in sudden load change.

  • PDF

Modeling of Power Networks by ATP-Draw for Harmonics Propagation Study

  • Ali, Shehab Abdulwadood
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.6
    • /
    • pp.283-290
    • /
    • 2013
  • This paper illustrates the possibilities of using the program ATP-Draw (Alternative Transient Program) for the modeling of power networks to study power quality problems with highly detailed analyses. The Program ATP-Draw is one of the most widespread and oldest programs. A unique characteristic of this program is its public domain and the existence of forums and study committees where new application cases and modification are presented and shared publicly. In this paper, to study the propagation of harmonics through a power network, a part of an industrial power network was modeled. The network contains different types of electric components, such as transformers, transmission lines, cables and loads, and there is a source of harmonics that injects $3^{rd}$, $5^{th}$, $7^{th}$, $9^{th}$ and $11^{th}$ harmonic currents into the network, causing a distortion of the wave form of the currents and voltages through the power network.

A Study on the Harmonics Reduction using Phase Shifting Transformer in a Electric Power Distribution System (배전계통에서 위상조정 변압기를 사용한 고조파 저감에 관한 연구)

  • 김경철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.2
    • /
    • pp.38-44
    • /
    • 2002
  • The increasing use of non-linear loads such as power electronics draw highly distorted currents from the utility system High harmonics current, and voltages will cause equipment damage and disturb the plant operation. The application of phase shifting transformers can be a very cost-effective method of harmonic treatment where multiple harmonic sources ice in operation. In this paper simulation results used the EDSA harmonics analysis program verifying the effects of a phase shifting transformer for harmonic elimination are presented.

A New Harmonics Reducing Type High Factor Single-Phase Rectifier Circuit (새로운 고조파 저감형 고역율 단상정류 회로)

  • Kim, Chil-Yong;Mun, Sang-Pil;Cho, Man-Chul;Shu, Ki-Young;Kwon, Soon-Kurl
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.468-472
    • /
    • 2007
  • For small capacity rectifier circuits such as these for consumer electronics and appliances, capacitor input type rectifier circuits are generally used. Consequently, various harmonics generated within the power system become a serious problem. Various studies of this effect have been presented previously. The absence of switching devices makes systems more tolerant to over-load, and brings low radio noise benefits. We propose a power factor correction scheme using a LC resonant in commercial frequency without switching devices. In this method, It makes a sinusoidal wave by widening conduction period using the current resonance in commercial frequency, Hence, the harmonic characteristics can be significantly improved, where the lower order harmonics, such as the fifth and seventh orders are much reduced. The result are confirmed by the theoretical and expermental implementations

  • PDF

Low-Frequency Harmonic Eliminations on DC/AC Sides of a 3 Phase-Controlled Converter (3상 제어컨버터의 노치법에 의한 출력과 입출력의 저고조파 제거)

  • 홍성태;권순결;이현우;서기영;임근희
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.6
    • /
    • pp.906-915
    • /
    • 1994
  • Line-Current harmonics resulting from ac to dc power conversion interfere with power system operation and reduce power factor, hence resulting in increasing power source unnecessarily. This study describes a 3 phase phase-controlled converter eliminating low frequency harmonics in the output by inserting notches. Notch points are calculated by Newton-raphson method, The impacts of the choppings on ac and dc sides are analyzed in the steady state. Potential applications of the study are dc motor controls, high power dc power supplies for telecommunications, static var compensators and HVDC.

  • PDF

Development of Control Algorithm of D-STATCON(Distribution STATic-CONden: Compensations of Voltage Flicker and Harmonics (전압 플리커 및 고조파 보상을 위한 배전용 STATCON의 제어알고리즘 개발)

  • Jeon, Y.S.;Oh, K.I.;Lee, K.S.;Choo, J.B.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1282-1286
    • /
    • 1999
  • This paper presents the DQ transfomation and space vector modulation method to develop a control algorithm of distribution STATCON(STATic CONdenser) for line voltage regulation, dc link voltage regulation and harmonics compensation. The Performance analysis of a PI with ramp comparision and synchronous reference frame current controller is carried out. Based on these analysis, the control performances are desirable to compensate the harmonics and to regulate de link and line voltage of Distribution line.

  • PDF

A Software-Based Controller Eliminating Low Frequency Harmonics from a $3{\varphi}$ Phase Controlled Converter (3상 위상제어 컨버터의 저고조파 제거를 위한 제어기)

  • 홍성태;배영호;권순결;이현우;서기영
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.9
    • /
    • pp.178-185
    • /
    • 1994
  • This study describes a software-based conrol methodology eliminating low-frequency harmonics from a 3.phi. phase-controlled converter. The converter topology used in the study is capable of the phase current lagging and dealying with respect to the phase voltage. Low order harmonics are eliminated in the dc output voltage by introducing notches. The good agreements between the simulation and experimental resuls show the validity of the proposed scheme. The use of the software-based control scheme results in a simple and flexible realization of the system.

  • PDF