• Title/Summary/Keyword: Current detection

Search Result 2,501, Processing Time 0.028 seconds

The Design & Manufacture and Characteristic Analysis of Eddy Current Sensor for Bolt Hole Defect Evaluation (볼트 홀 결함 평가용 와전류 센서 설계제작 및 특성분석)

  • Ahn, Y.S.;Gil, D.S.;Park, S.G.
    • Journal of Power System Engineering
    • /
    • v.15 no.4
    • /
    • pp.37-41
    • /
    • 2011
  • This paper introduces the special eddy current sensor and its characteristic for bolt hole defect evaluation in gas turbine rotor. In the past, Fluorescent penetration inspection method was used for qualitative defect evaluation in gas turbine rotor bolt hole. This method can defect the bolt hole defect but can not evaluate the defect size. Nowadays, eddy current method is used quantitative defect evaluation due to advanced sensor design technology. And eddy current method is more time and cost saving than the old method. We developed bolt shape eddy current sensor for the rotor bolt hole defect detection and evaluation. The eddy current sensor moves to the bolt hole guided by screw nut and detects the defect on the bolt hole. The bolt hole mock-up and artificial defects were made and used for the signal detection & resolution analysis of eddy current sensor. The results show that signal detection capability is enough to detect 0.2 mm depth defect. And the resolution capability is enough to differentiate 02, 0.5, 1.0 and 2.0 mm depth defect.

Fault Detection and Isolation of Parallel Operation of Two Converters Using Zero Current Transformer Method (영상변류기 동작 방식을 이용한 2개의 컨버터 병렬 운전시 고장 탐지 및 분리)

  • 손승찬;성세진
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.409-416
    • /
    • 2000
  • In case of operating two converters in parallel with ZCT operation method using one current sensor for fault tolerance by system characteristics, identifying fault detection and isolation is difficult of which converter is fault since the ZCT output is a difference of two converters' supply current when a converter has fault. This thesis suggest a fault detection and isolation method of converter in case of operating two converters in parallel for fault tolerant system and verified this suggested method through an experiment.

  • PDF

The Study on The Complex Composition By SFCL and Power Equipments for Fault Detection in HVDC Line (HVDC 선로 내 초전도 한류기와 전력기기들의 복합 구성을 통한 고장 검출에 관한 연구)

  • Kim, Myong-Hyon;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.1113-1118
    • /
    • 2018
  • Protection in HVDC(High Voltage Direct Current) have the very fast velocity of fault detection. Because Fault in HVDC has the fast propagation, large currents, high interruption cost. The focus to velocity caused possibility of errors like a detection error like a high impedance fault. In this paper, Proposed complex composition for get the reliability and velocity. That used SFCL(Super Conducting Fault Current Limiter), Protection Zone and DTS(Distributed Temperature Sensing). The SFCL was detect the fault by quench and DTS&Protection Zone were perceive the detect by variation too. To examine the proposed method, PSCAD/EMTDC simulated. The results of simulation, proposed methods could the detect of fault to whole HVDC line. And that improved the reliability of fault clearing.

The Implementation of the system-on-board controllable the electrical fires due to ground fault, arc fault and overload (누전, 아크, 과부하에 의한 전기화재 제어 시스템 보드의 구현)

  • Kim, Byung-Cheul;Chun, Joong-Chang
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.2
    • /
    • pp.419-424
    • /
    • 2011
  • The system-on-board detectable and controllable the electrical fires due to ground fault(GF), arc fault and overload is implemented. The system IC for controlling and preventing the electrical fires is available to this system. The GF detection circuit for detecting the electrical leakage current, the arc fault detection circuit and the overload detection circuit controllable the input voltage for flowing the overload current are designed. The GF detection circuit and the arc fault detection circuit are good operated to the electrical leakage current and the arc signal, respectively. It is confirmed that the overload detection circuit has shown no erratic operation with the noise or the load variation and is only operated at the overload condition.

A Study on the Detection Technique of the Flame and Series arc by Poor Contact (접촉 불량에 의한 불꽃 및 직렬아크의 검출 기법에 관한 연구)

  • Woo, Kim Hyun;Hyun, Baek Dong
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.24-30
    • /
    • 2012
  • This study is on the method of the detection for flame and series arc which can be happened at poor contact point added a vibration in part of contact point of low voltage line. In general, the causes of electric fire are over current, short circuit, poor contact, ect. The over-current or short circuit among those causes is detected by measuring a instant current value, but poor contact is difficult to detect by measuring a excessive value of the voltage and current and a distortion of waveforms. And therefore, in this paper, it is studied on the optimal technique of the arc judgement using fuzzy logic and MDET (Multi Dimension Estimation Technique). And it carries out the simulation for arc detection and the experiment for controller and load test. In result, the controller and detection algoristhm, is classified with normal wave and abnormal arc wave without relation with each loads and so the controller can detect a series arc successfully.

Tool Fracture Detection in Milling Process (II) -Part 2: Tool Fracture Detection in Rough Milling Using Spindle Motor Current- (밀링 공정시 공구 파손 검출 (II) -제 2 편: 주축모터 전류를 이용한 밀링의 황삭 가공 중 공구파손 검출-)

  • 김기대;이강희;주종남
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.5
    • /
    • pp.110-119
    • /
    • 1998
  • Dynamic cutting force variations in milling process were measured indirectly using spindle motor current. Magnitude of the spindle motor current is independent of cutting direction. Quasi-static sensitivity of the spindle motor current is higher than that of the feed motor current. Dynamic sensitivity of the spindle motor current is lower but cutting force was correctly represented by spindle RMS current in rough milling. In rough milling, chipping and tool fracture were well detected by the proposed tool fracture index using spindle motor current.

  • PDF

Islanding Detection by Harmonic Current Injection Method for Utility Interactive Photovoltaic System (고조파 주입에 의한 계통연계형 태양광발전시스템의 고립운전 검출)

  • 고재석;채영민;강병희;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.199-210
    • /
    • 2003
  • In this paper, the new Islanding detection method is studied for utility interactive photovoltaic system(UIPVS). It describes the brief of UIPV system and the features of islanding phenomenon. The new islanding detection method for improving the detection characteristics, HCIM(Harmonic Current Injection Method), is proposed and analyzed. The impedance curve of AC load is derived from the complex power equation for testing Islanding detection features. The proposed detection method and the derivation of islanding condition we verified by the simulation with ACSL and the laboratorial experiments.

A New Efficient Impulse Noise Detection based on Rank Estimation

  • Oh, Jin-Sung;Kim, You-Nam
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.3
    • /
    • pp.173-178
    • /
    • 2008
  • In this paper, we present a new impulsive noise detection technique. To remove the impulse noise without detail loss, only corrupted pixels must be filtered. In order to identify the corrupted pixels, a new impulse detector based on rank and value estimations of the current pixel is proposed. Based on the rank and value estimations of the current pixel, the new proposed method provides excellent statistics for detecting an impulse noise while reducing the probability of detecting image details as impulses. The proposed detection is efficient and can be used with any noise removal filter. Simulation results show that the proposed method significantly outperforms many other well-known detection techniques in terms of image restoration and noise detection.

  • PDF

A Study of the Current Reference Signal Generation Circuit for Single-Phase Harmonic Elimination Systems (단상 전원 고조파 제거 시스템을 위한 기준전류 생성회로에 대한 연구)

  • Jung Done-youl;Park Chong-yeon;Kim Sang-hun;Choi Won-ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.7
    • /
    • pp.335-342
    • /
    • 2005
  • This paper presents a circuit to generate the current reference signal for single-phase harmonic elemination systems. Some of conventional methods for the current reference signal generation based on neural network algorithms. It requires complex circuitry to implement. the simplest method is to use analog filters. but it is difficult to obtain good current reference signals. So, we propose the harmonic detection circuit using GIC(Generalized Impedance Converter) for the purpose of low cost ,simple circuitry and high performance, Simulation and experimental results verify that the proposed circuit has better harmonic detection performance than conventional circuit.

A Study on the Detection of the Chatter Using Current Signal in Turning (선삭가공시 전류신호를 이용한 채터 검출에 관한 연구)

  • 서한원;유기현;오석형;서남석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.947-951
    • /
    • 1997
  • Recently, the necessity of the detection of abnormal machining process is being emphasized in order to improve the machining accuracy and reduce the cost in unmanned operating system. The vibration by chatter generated in cutting processes within machine tools is a relative motion between tools and workpieces. So, if the chatter occurs, the surface roughness and accuracy of workpieces will be deteriorate and it leads to the rapid wear of tools. The author intended to use the I /sab/RMS (current of root mean square) of current sigals and the movimg C.V. (coefficient of variation) of each phase for the detection method of chatter.

  • PDF