• 제목/요약/키워드: Current density

검색결과 5,630건 처리시간 0.035초

플라즈마 삽입전극의 전류에 미치는 밀도 구배의 영향 (Influence of the Density Gradient on the Current of the Electrode Immersed in the Non-uniform Plasma)

  • 황휘동;구치욱;정경재;최재명;김곤호;고광철
    • 한국전기전자재료학회논문지
    • /
    • 제24권6호
    • /
    • pp.504-509
    • /
    • 2011
  • The conducting current of non-uniform plasma immersed electrode consists of ion current and secondary electron emission current caused by the impinging ion current. The ion current is determined by the ion dose passing through the sheath in front of electrode and the ion distribution in front of the electrode plays an important role in the secondary electron emission. The investigation of the distributed plasma and secondary electron effect on electrode ion current was carried out as the stainless steel electrode plugged with quartz tube was immersed in the inductively coupled Ar plasma using the antenna powered by 1 kw and the density profile was measured. After that, the negative voltage was applied by 1 kV~6 kV to measure the conduction current for the analysis of ion current.

전기화학적 가속 부식 평가법에서 강재의 부식 손상에 미치는 인가전류밀도의 영향 (Effect of Applied Current Density on the Corrosion Damage of Steel with Accelerated Electrochemical Test)

  • 이정형;박일초;박재철;김성종
    • 한국표면공학회지
    • /
    • 제49권5호
    • /
    • pp.423-430
    • /
    • 2016
  • In this study, we investigated the corrosion damage characteristics of steel for offshore wind turbine tower substructure using an accelerated electrochemical test. The galvanostatic corrosion test method was employed with a conventional 3 electrode cell in natural sea water, and the steel specimen was served as a working electrode to induce corrosion in an accelerated manner. Surface and cross-sectional image of the damaged area were obtained by optical microscope and scanning electron microscope. The weight of the specimens was measured to determine the gravimetric change before and after corrosion test. The result revealed that the steel tended to suffer uniform corrosion rather than localized corrosion due to active dissolution reaction under the constant current regime. With increasing galvanostatic current density, the damage depth and surface roughness of surface was increased, showing approximately 25 times difference in damage depth between the lowest current density ($1mA/cm^2$) and the highest current density ($200mA/cm^2$). The gravimetric observation showed that the weight loss was proportionally increased with increment of current density that has 75 times different according by experimental conditions. Consequently, uniform corrosion of the steel specimen was conveniently induced by the electrochemically accelerated corrosion technique, and it was possible to control the extent of the corrosion damage by varying the current density.

알카리 수용액에서 Mg-Al 합금의 양극산화시 전류밀도와 양극산화 시간의 효과 (Effects of Time and Current Density in Anodizing of Mg-Al Alloy in Alkaline Solution)

  • 장석기;김성종;김정일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권1호
    • /
    • pp.107-115
    • /
    • 2005
  • The effects on the formation of anodic oxide films on Mg-Al alloy (AZ91) in 1M-NaOH solution was investigated using parameters of current density and time during anodizing The general tendency has been confirmed that the increase of anodizing time improves the corrosion resistance. It is considered that the formation of anodic oxide film was increased by increasing the applied current and the anodizing time to generate active dissolution reaction In anodizing at constant current density. passivity potentials shifted to noble direction with increasing current densities. It was confirmed that oxygen quantify in anodic oxide films increased with anodizing time. The compact films above 4 $mA/cm^2$ were formed with the shape of an island in grooves at early stage and then grew with combination of the islands

양극산화에 의한 다공성 알루미나 막의 기체투과 특성 (Gas Permeation Characteristics of Porous Alumina Membrane Prepared by Anodic Oxidation)

  • 함영민
    • 환경위생공학
    • /
    • 제13권3호
    • /
    • pp.72-78
    • /
    • 1998
  • For investigation into gas permeation characteristics, the porous alumina membrane with asymmetrical structure, having upper layer with 10 nanometer under of pore diameter and lower layer with 36 nanometer of pore diameter, was prepared by anodic oxidation using DC power supply of constant current mode in an aqueous solution of sulfuric acid. The aluminium plate was pre-treated with thermal oxidation, chemical polishing and electrochemical polishing before anodic oxidation. Because the pore size depended upon the electrolyte, electrolyte concentration, temperature, current density, and so on, the the membranes were prepared by controling the current density, as a very low current density for upper layer of membrane and a high current density for lower layer of membrane. By control of current quantity, the thicknesses of upper layer of membranes were about $6{\;}{\mu}m$ and the total thicknesses of membranes were about $80-90{\;}{\mu}m$. We found that the mechanism of gas permeation depended on model of the Knudsen flow for the membrane prepared at each condition.

  • PDF

Corrosion Rate of Buried Pipeline by Alternating Current

  • Song, H.S.;Kim, Y.G.;Lee, S.M.;Kho, Y.T.;Park, Y.S.
    • Corrosion Science and Technology
    • /
    • 제4권1호
    • /
    • pp.1-7
    • /
    • 2005
  • An alternating current (AC) corrosion on buried pipeline has been studied using coupon and ER probe. Coupons and ER probes were applied to the sites from high value of AC voltage to low value based on the survey of AC voltages on buried gas transmission pipeline over the country. Parameters such as AC current density of coupon, AC voltage, cathodic protection potential, soil resistivity and frequency were monitored continually. Corrosion induced by AC was observed even under cathodically protected condition that met cathodic protection criterion (; below -850 mV vs. CSE). Corrosion rate was affected mainly not by AC voltage but by both of frequency and AC current density. An experimental corrosion rate relation could be obtained according to effective AC current density, in which AC corrosion rate increased linearly with effective AC current density, and its slope was 0.619 in coupon method and 0.885 in ER probes.

Investigation of Relationship between Etch Current and Morphology and Porosity of Porous Silicon

  • 장승현
    • 통합자연과학논문집
    • /
    • 제3권4호
    • /
    • pp.210-214
    • /
    • 2010
  • Relationship between etch current and morphology and porosity of porous silicon (PS) has been investigated. The gravimetric method is applied to measured the porosity of PS. As the current density increase, the silicon dissolution rate increases, resulting in a higher porosity and etching rate. The result shows that linear dependence of PS porosity and etching rate as a function of current density. The morphology of porous silicon was investigated by using cold field emission scanning electron micrograph (FE-SEM). The size of pores formed during anodization is predominantly controlled by the current density, with an increase in the pore size corresponding to an increase in the current density.

Sulfate 용액을 이용하여 전기도금 한 FCCL용 Cu 필름의 특성에 미치는 전류밀도와 pH의 영향 (Effect of Current Density and Solution pH on Properties of Electrodeposited Cu Thin Films from Sulfate Baths for FCCL Applications)

  • 신동율;박덕용;구본급
    • 한국표면공학회지
    • /
    • 제42권4호
    • /
    • pp.145-151
    • /
    • 2009
  • Nanocrystalline Cu thin films for FCCL were electrodeposited from sulfate baths to investigate systematically the influences of current density, solution pH on current efficiency, residual stress, surface morphology, and microstructure of thin Cu films. Current efficiencies were measured to be approximately 100%, irrespective of the applied current density and solution pH. But these influenced residual stress, surface morphology, XRD pattern, and grain size of electrodeposited Cu thin film. The residual stress decreased with decreasing the surface roughness, but increased with increasing the fcc(111) peak strength of XRD patterns.

전류 전처리의 경피 투과도에 미치는 효과 (Current Pretreatment of Skin and Its Effect on the Permeability)

  • 이정화;오승열
    • Journal of Pharmaceutical Investigation
    • /
    • 제35권2호
    • /
    • pp.81-87
    • /
    • 2005
  • We have prepared karaya gum patches containing ketoprofen and investigated the effect of short-time current pretreatment of skin on the permeability. Hairless mouse skin was treated with current before the patch was mounted on the skin. The effect of current density and current duration on the flux of ketoprofen was studied. The possibility of additive effect with penetration enhancer (PGML) was also investigated. Iontophoretic pretreatment of skin increased the passive flux up to 3 folds at 0.4 $mA/cm^2$ current density, when the matrix contained no PGML. As the duration of current-pretreatment and current density increased, flux increased. PGML increased the average passive flux markedly, about 6 to 12 folds, depending on the concentration in the patch. Current pretreatment further increased the flux from this PGML containing patch, exhibiting additive effect. These results indicate that short-duration current pretreatment of skin can be an useful method for the enhancement of ketoprofen permeability through skin.

전류밀도와 전기삼투 현상이 전기투석 공정의 탈염성능에 미치는 영향 (Effect of Current Density and Electroosmotic Phenomena on the Desalination Performance of the Electrodialysis Process)

  • 천은서;최재환
    • 공업화학
    • /
    • 제34권3호
    • /
    • pp.272-278
    • /
    • 2023
  • 이 연구에서는 전류밀도와 전기삼투 현상이 전기투석(electrodialysis, ED)의 탈염성능에 미치는 영향을 분석하였다. 농축액의 농도를 10~200 g/L로 변화시키면서 정전압 조건에서 ED 실험을 진행하였다. ED 운전과정에서 스택에 공급되는 전류밀도와 전하량, 희석액과 농축액의 농도, 그리고 전기삼투에 의한 물 이동량을 측정하여 탈염성능을 분석하였다. 농축액의 농도가 증가함에 따라 이온교환막의 선택성이 감소하여 전류효율이 감소하였다. 또한 전류효율은 스택에 공급되는 전류밀도에 영향을 받는 것으로 나타났다. 전류밀도가 15 mA/cm2 이상에서는 역 확산이 억제되어 전류효율이 증가하였다. ED 운전과정에서 전기삼투에 의한 물 이동량을 분석하였다. 물 이동량은 농축액과 희석액의 농도비에 비례하여 증가하는 것을 알 수 있었다. 농도비가 100 이상에서는 삼투압에 의한 물 이동량이 급격히 증가하여 200 g/L 이상의 농축액을 얻는데 한계가 있는 것으로 나타났다.

이온토포레시스를 이용한 케토프로펜의 경피전달 (Iontophoretic Transport of Ketoprofen)

  • 김정애;오승열
    • Journal of Pharmaceutical Investigation
    • /
    • 제34권4호
    • /
    • pp.275-281
    • /
    • 2004
  • We have studied the effect of polarity, current density, current duration, crosslinking density, swelling ratio, and permeation enhancers on the transdermal flux of ketoprofen from acrylamide hydrogel. Hydrogel was prepared by free radical crosslinking polymerization of acrylamide. Drug loading was made just before transport experiment by soaking the hydrogel in solution containing drug. In vitro flux study using hairless mouse skin was performed at $36.5^{\circ}C$ using side-by-side diffusion cell, and the drug was analysed using HPLC/UV system. The result showed that, compared to passive flux, the total amount of drug transported increased about 18 folds by the application of $0.4\;mA/cm^2$ cathodal current. Anodal delivery with same current density also increased the total amount of drug transported about 13 folds. It seemed that the increase in flux was due to the electrorepulsion and the increase in passive permeability of the skin by the current application. Flux increased as current density, the duration of current application and loading amount (swelling duration) increased. As the cross linking density of the hydrogel increased, flux clearly decreased. The effect of hydrophilic enhancers (urea, N-methyl pyrrolidone, Tween 20) and some hydrophobic enhancers (propylene glycol monolaurate and isopropyl myristate) was minimal. However, about 3 folds increase in flux was observed when 5% oleic acid was used. Overall, these results provide some useful information on the design of an optimized iontophoretic delivery system of ketoprofen.