배전시스템 고조파 모델링에 관한 연구 (Harmonics Modelling for Distribution System)

  • 한형주;왕용필;정형환;성병화;박희철;박인표
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.205-207
    • /
    • 2005
  • In this paper, the Point of Common Coupling (PCC) is selected to analyze harmonic characteristic of distribution system by IEC 61000 - 3 - 6 in Electromagnetic Compatibility(EMC). Harmonic voltage and current were measured at the PCC of real distribution system. Harmonic distribution, nonlinear load component and Total Harmonic Distortion(THD) were verified by measurement. The effective and accurate modelling of real distribution system were proved through a analysis of harmonic impedance, voltage and current in steady-state. Harmonic transfer characteristic in distribution system were summarized and investigated through a analysis of harmonic voltage and harmonic current in harmonic current source.

  • PDF

6고조파 주입 PWM을 이용한 3상 승압형 컨버터 고조파저감 (Harmonic Reduction in Three-Phase Boost Converter with Six Harmonic Injected PWM)

  • 이정훈;김재문;안정준;이정호;원충연;정동효
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.327-332
    • /
    • 1999
  • In this paper, six harmonic injection PWM method for reducing total harmonic distortion in single switch three phase discontinuous conduction mode boost converter is presented. In the proposed method, periodic six harmonic voltage is injected in the control circuit to vary the duty ratio of the converter switch within a line cycle so that the fifth order harmonic of the input current is reduced. Experimental results are verified by converter operating at 400V/6kW with three phase 140V~220V input.

  • PDF

푸리에 변환을 이용한 다중 재폐로방식에서의 사고전류 특징 추출 (Feature Extraction of Fault Current using Fourier Transform in the Multi-Shot Reclosing Scheme)

  • 오정환;윤상윤;김재철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권2호
    • /
    • pp.50-55
    • /
    • 2000
  • This paper presents the feature extraction of fault currents related to the multi-shot reclosing scheme in the power distribution system. In order to get the fault current waveform, we have measured the fault currents by the fault recorders which have been installed at the secondary side of 154/22.9[kV] substation transformer. These waveforms are classified into temporary and permanent fault. For the classified waveforms, Fourier transform is used to extract the feature of the fault current waveforms. After the waveforms are analyzed by using Fourier transform, the magnitude spectrum and the relative variation of THD (Total Harmonic Distortion) are calculated. And then the relative variation of THD is great in the temporary faults, and is small in the permanent faults.

  • PDF

단상 전압 소스 인버터의 고조파 왜곡 보상을 위한 비례 다중 공진 제어기에 관한 연구 (A study on proportional multiple-resonance controller for harmonic distortion compensation of single phase VSIs)

  • 곽봉우
    • 전기전자학회논문지
    • /
    • 제27권3호
    • /
    • pp.319-326
    • /
    • 2023
  • 본 논문에서는 단상 전압 소스 인버터 (VSIs)의 강인한 출력 전압 제어를 위한 디지털 제어기 구현과 총 고조파 왜곡(T.H.D.v) 분석을 포함한 시뮬레이션 및 실험 결과를 제시한다. 일반적으로 VSI는 내부 루프의 전류 제어기에 비례 적분(PI) 제어기를 사용하고 외부 루프의 전압 제어기에 비례 공진 (PR) 제어기가 사용된다. 그러나, 비선형 부하에서 여전히 3차, 5차 및 7차와 같은 고차 고조파 왜곡이 발생한다. 따라서 본 논문에서는 고조파 왜곡을 억제하기 위해 홀수 고조파 주파수에 대한 공진 제어기를 포함한 비례 다중 공진 (PMR) 제어기를 제안한다. VSI 플랜트용 컨트롤러의 주파수 응답을 분석하고 PMR 컨트롤러를 설계합니다. 시뮬레이션을 통해 PI와 PMR을 전압 제어기로 사용할 때 출력 전압의 총 고조파 왜곡 특성을 비교 검증합니다. 선형 및 비선형 하중 조건이 모두 고려되었습니다. 마지막으로 PMR 제어기를 3kW급 VSIs 프로토 타입에 적용하여 그 유효성을 입증하였다.

The Iron loss Estimation of IPMSM According to Current Phase Angle

  • Cho, Gyu-Won;Kim, Dong-Yeong;Kim, Gyu-Tak
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1345-1351
    • /
    • 2013
  • Variable iron loss as function of current phase angle of Interior Permanent Magnet Synchronous Motor(IPMSM) was calculated through Curve Fitting Method(CFM). Also, a magnetic flux density distribution of iron core according to current phase angle was analyzed, and an iron loss calculation was performed including harmonic distortion. The experiment was performed by production of non-magnetizing model for the separation of mechanical loss, and the iron loss was calculated by the measurement of input using power analyzer and output power using dynamometer. Some error was generated between experimental results and calculation value, but an iron loss diminution according to current phase angle followed a same pattern. So, errors were generated by measurement, vibration, noise, harmonic distortion loss, etc.

풍력 유도발전기의 여자 축전지에 따른 고주파 증폭에 관한 기술 동향 (Technical Trend on Excitation Capacitors on Harmonic Amplification of Wind Induction Generator)

  • 노상필;박정석;이영길;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1976-1977
    • /
    • 2007
  • This paper introduce the electrical quantities of a three-phase-connected wind induction generator (WIG) under sudden connection of static loads. An intelligent power-system recorder/monitor is employed to measure threephase voltages and currents of the studied system at WIG's terminals and load's terminals for 5 minutes. A laboratory 300 W wound-rotor induction machine driven by a blushless DC motor is utilized as the studied WIG. Since the generated harmonic currents are randomly varied, total harmonic distortion (THD) of current using cumulative probability density function is employed to determine the penetration of harmonic distortion. The results show that the harmonic currents generated by the studied WIG may be severely amplified to a high level by the connected self-excited capacitance at the stator's terminals.

  • PDF

Design of DC Side Voltage and Compensation Analysis of THD for Shunt Power Quality Controller under System Load of Rectifier with R-L Load

  • Zhao, Guopeng;Han, Minxiao
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.30-40
    • /
    • 2015
  • For a shunt power quality controller (SPQC) the DC side voltage value which is closely related to the compensation performance is a significant parameter. Buy so far, very little discussion has been conducted on this in a quantitative manner by previous publications. In this paper, a method to design the DC side voltage of SPQC is presented according to the compensation performance in the single-phase system and the three-phase system respectively. First, for the reactive current and the harmonic current compensation, a required minimal value of the DC side voltage with a zero total harmonic distortion (THD) of the source current and a unit power factor is obtained for a typical load, through the equivalent circuit analysis and the Fourier Transform analytical expressions. Second, when the DC side voltage of SPQC is lower than the above-obtained minimal value, the quantitative relationship between the DC side voltage and the THD after compensation is also elaborated using the curve diagram. Hardware experimental results verify the design method.

Robust Active LED Driver with High Power Factor and Low Total Harmonic Distortion Compatible with a Rapid-Start Ballast

  • Park, Chang-Byung;Choi, Bo-Hwan;Cheon, Jun-Pil;Rim, Chun-Taek
    • Journal of Power Electronics
    • /
    • 제14권2호
    • /
    • pp.226-236
    • /
    • 2014
  • A new active LED driver with high power factor (PF) and low total harmonic distortion (THD) compatible with a rapid-start ballast is proposed. An LC input filter is attached to the ballast to increase PF and reduce THD. A boost converter is then installed to regulate the LED current, where an unstable operating region has been newly identified. The unstable region is successfully stabilized by feedback control with two zeroes. The extremely high overall system of the 10th order is completely analyzed by the newly introduced phasor transformed circuits in static and dynamic analyses. Although a small DC capacitor is utilized, the flicker percentage of the LED is drastically mitigated to 1% by the fast controller. The proposed LED driver that employs a simple controller with a start-up circuit is verified by extensive experiments whose results are in good agreement with the design.

FPGA Implementation of Diode Clamped Multilevel Inverter for Speed Control of Induction Motor

  • Kuppuswamy, C.L.;Raghavendiran, T.A.
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.362-371
    • /
    • 2018
  • This work proposes FPGA implementation of Carrier Disposition PWM for closed loop seven level diode clamped multilevel inverter in speed control of induction motor. VLSI architecture for carrier Disposition have been introduced through which PWM signals are fed to the neutral point seven level diode clamped multilevel using which the speed of the induction motor is controlled. This proposed VLSI architecture makes the power circuit to work better with reduced stresses across the switches and a very low voltage and current total harmonic distortion (THD). The output voltages, currents, torque & speed characteristics for seven level neutral point diode clamped multilevel inverter for AC drive was studied. It has observed the proposed scheme introduces less distortion and harmonics. The results were validated using real time results.

반복제어기를 적용한 단상 계통연계형 인버터의 전력품질 개선 (Improvement of Power Quality of Single-phase Utility Interactive Inverter using Repetitive Controller)

  • 김재한;목형수;최규하;이진우;정교범;이정민;조영훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.11-14
    • /
    • 2007
  • In recent years, installation of the new and renewable energy system is rapidly increasing. Because the new and renewable energy system is a practical distributed generation system to save energy resources and to keep environments clean. Conventional single-phase utility interactive inverter controls output current by using PI current controller. However, this method is insufficient to suppress harmonic current resulted from nonlinear loads in grid line. In this paper, in order to suppress periodic waveform distortion and improve THD(Total Harmonic Distortion), new type current controller added a parallel repetitive controller is proposed and then performance of the proposed controller was verified with computer simulation.

  • PDF