• Title/Summary/Keyword: Current Regulation

Search Result 1,502, Processing Time 0.04 seconds

Homeostatic Regulation of Glucose Metabolism by the Central Nervous System

  • Jong Han Choi;Min-Seon Kim
    • Endocrinology and Metabolism
    • /
    • v.37 no.1
    • /
    • pp.9-25
    • /
    • 2022
  • Evidence for involvement of the central nervous system (CNS) in the regulation of glucose metabolism dates back to the 19th century, although the majority of the research on glucose metabolism has focused on the peripheral metabolic organs. Due to recent advances in neuroscience, it has now become clear that the CNS is indeed vital for maintaining glucose homeostasis. To achieve normoglycemia, specific populations of neurons and glia in the hypothalamus sense changes in the blood concentrations of glucose and of glucoregulatory hormones such as insulin, leptin, glucagon-like peptide 1, and glucagon. This information is integrated and transmitted to other areas of the brain where it eventually modulates various processes in glucose metabolism (i.e., hepatic glucose production, glucose uptake in the brown adipose tissue and skeletal muscle, pancreatic insulin and glucagon secretion, renal glucose reabsorption, etc.). Errors in these processes lead to hyper- or hypoglycemia. We here review the current understanding of the brain regulation of glucose metabolism.

A Study on the Appropriateness of Regulatory Impact Analysis(RIA) on Technological Regulation: With the Focus on the Technological Regulation Impact Assessment (기술규제 규제영향분석의 적절성에 대한 연구: 기술규제영향평가 차원에서)

  • Lee, Ji-Eun;Kim, Tae-Yun
    • Journal of Technology Innovation
    • /
    • v.25 no.3
    • /
    • pp.233-263
    • /
    • 2017
  • The purpose of this study is to examine the appropriateness of Regulatory Impact Analysis(RIA) in terms of the technological regulation impact assessment in order to confirm whether the current RIA process reflects the important characteristics of technological regulation. This paper develops a logical framework for analysis of technological regulation and evaluates the appropriateness of the RIA statements submitted by the government departments. From the viewpoint of [technological feasibility of regulation], [synthesis of domestic technological norms], [synthesis of international technological norms], as a result of evaluating the contents of the actual RIA statement on the basis of objective facts, feasibility of alternative analysis, and expert judgment, only 23.4% of the RIA statements were judged "appropriate", and there were no particular differences among the government. As a result of reviewing the appropriateness of RIA statements according to regulatory attributes, the appropriateness of RIA statements on technological regulation with social regulatory and indirect regulatory attributes was rather high. In sum, the level of Korean RIA statements is insufficient to carry out the practical meaning of technological regulation impact assessment. That is, as each government department adopts technological regulation, the understanding of the technological properties of the regulation may not be complete. The RIA statement that does not adequately reflect the technological rationale, hinders the careful review of other regulatory alternatives by exaggerating the feasibility of the technology regulation, at the same time leads to the serious problems that impede the acquisition of competitiveness of companies and the public in the global competition system.

A Comparative Study on the Regulation of Explosive Noise in Demolition Work at Home and abroad (국내외 철거작업시 발파소음 규제에 대한 비교 연구)

  • Ki-Taek Oh
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.4
    • /
    • pp.984-992
    • /
    • 2023
  • Purpose: The core problem of this study is that there are no specific noise regulation standards for domestic blasting work. Currently, the domestic blasting work noise regulation standard has not been established separately, and the noise regulation standard of 80 decibels is corrected by 10 decibels to 70 decibels, which is the daily living noise standard. In contrast, many foreign countries have separate noise regulation standards specifically tailored to blasting work. Accordingly, it is intended to present international reasonable blasting noise standards by comparing domestic and foreign blasting work noise regulation standards. Mmethod: This study can be inferred as a comparative analysis of domestic and foreign noise regulation standards. Data on the current noise regulation standards during domestic blasting and noise regulation standards during blasting operations in the United States, the United Kingdom, Australia, Japan, and China are collected and analyzed. Results: According to the study, the noise regulation value during blasting work at domestic construction sites was not separately established, so it was not properly tailored to the specific and characteristics of blasting noise. In the case of overseas, a realistic noise regulation value was established so that a safer, more efficient and eco-friendly blasting method could be applied to the noise regulation value uniformly during blasting work. Conclusion: In this study, it is hoped that noise regulations will be established during reasonable blasting work, as shown in domestic and international comparative studies, and will be widely adopted without interfering with the introduction of efficient, economical, and eco-friendly blasting methods by complying well with blasting safety standards.

A Study on the Health Benefits Labeling for Livestock Products (축산물의 유용성 표시에 대한 고찰)

  • Jang, Ae-Ra;Chae, Hyun-Seok;Yoo, Young-Mo;Ham, Jun-Sang;Jeong, Seok-Geun;Lee, Seung-Gyu;Ahn, Chong-Nam;Kim, Dong-Hoon;Lee, Sung-Ki;Lee, Eui-Soo
    • Food Science of Animal Resources
    • /
    • v.29 no.5
    • /
    • pp.599-611
    • /
    • 2009
  • This article concerns the labeling guideline for health benefits of livestock products. In recent years, livestock products with health benefits have emerged as a key market for livestock product industries. However, the current labeling regulation for functional foods severely prohibits livestock product industries from attaching most of the health benefits claims to the products. Also, manufacturers have some difficulties in labeling the health benefits of certain livestock products because of a lack of guidelines on health benefit claims for livestock products. Therefore, some livestock product industries and scientists have strongly demanded a revision of labeling regulation, Appended Chart No. 14 provided by Article 52 (2) of Enforcement Regulation of the Processing of Livestock Products Act, so they could mark the health benefits on their products. To support the 'revision of labeling regulation', the goals of this article were as follows; 1) to assess the current situation on nutrition labeling and nutrition claims on foods, 2) to determine the current situation on health claim regulatory systems used in foreign countries (CODEX, USA, Japan, EU, and Australia/New Zealand), 3) to assess the current situation on the health claim or health benefit claim regulations for functional foods, conventional foods, and livestock products in Korea, and 4) to determine the need for complement in health benefit claim for livestock products. In conclusion, guidelines for the use of health benefit claims on livestock products should be prepared as soon as possible and the guidelines should be viable and easy for manufacturers and control authorities to understand. Also, nutrient profiles should be developed to identify whether the livestock products are eligible to bear health benefit claims and to help consumers make the right choices.

Current Control for Three Phase PWM Converter Using LQ Controller with Conditional Integrator (조건부 적분기를 가지는 LQ 제어기를 이용한 3상 PWM 컨버터의 전류제어)

  • 김홍성;전윤석;조영준;목형수;최규하;김한성
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.345-351
    • /
    • 1997
  • In this paper, controller for PWM converter considering unsymetrical input voltage is designed and current controller using LQ controller with conditional integrator is proposed. And the proposed current controller is compared with other current controller-predictive controller, decoupling PI controller. As simulation results, LQ controller with Conditional Integrator shows the improved performance for DC link voltage regulation through transient test of load variation. And when unsymeritrical input voltage is applied to converter with conventional current controller considering only symetrical input voltage, input current is distorted but it is showed that current controller considering unsymetrical input has robust control characteristics under phase voltage unbalance.

  • PDF

Parallel Connected High Frequency AC Link Inverters Based on Full Digital Control

  • Sha, Deshang;Guo, Zhiqiang;Deng, Kai;Liao, Xiaozhong
    • Journal of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.595-603
    • /
    • 2012
  • This paper presents a full digital control strategy for parallel connected modular inverter systems. Each modular inverter is a high frequency (HF) AC link inverter which is composed of a HF inverter and a HF transformer followed by a cycloconverter. To achieve equal sharing of the load current and to suppress the circulating currents among the modules, a three-loop control strategy, consisting of a common output voltage regulation (OVR) loop, individual circulating current suppression (CCS) loops and individual inner current tracking (ICT) loops, is proposed. The ICT loops are implemented with predictive current control from which high precision current tracking can be obtained. The effectiveness of the proposed control strategy is verified by simulation and experimental results from parallel connected two full-bridge HF AC link inverter modules.

A Study on Open-frame Type DC-DC Converter Module for Low-Voltage High-Current Applications (저전압 대전류용 개방형 DC-DC 컨버터 모듈에 관한 연구)

  • 안태영;황선민;조인호
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.4
    • /
    • pp.183-190
    • /
    • 2003
  • We report the performance of an open-frame type low-voltage high-current DC-DC converter module developed using an active clamp forward converter circuit and current doubler rectifier. The converter module is designed with the specifications of an 1.8V output voltage, 25A output current, and 36-75V input voltage. The synchronous rectifier is used to reduce the conduction fuss at high current level and current-mode control is adapted to enhance the flexibility in the system configuration. A prototype converter module is successfully implemented within 10mm height and half brick size (58${\times}$61mm), and recorded an 84% efficiency and 4% voltage regulation for the entire input voltage range, thereby demonstrating its application potentials to future telecommunication electronics.

A Study on Open-frame Type DC-DC Converter Module for Low-Voltage High-Current Applications (저전압 대전류용 개방형 DC-DC 컨버터 모듈에 관한 연구)

  • 안태영;황선민;조인호
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.4
    • /
    • pp.183-183
    • /
    • 2003
  • We report the performance of an open-frame type low-voltage high-current DC-DC converter module developed using an active clamp forward converter circuit and current doubler rectifier. The converter module is designed with the specifications of an 1.8V output voltage, 25A output current, and 36-75V input voltage. The synchronous rectifier is used to reduce the conduction fuss at high current level and current-mode control is adapted to enhance the flexibility in the system configuration. A prototype converter module is successfully implemented within 10mm height and half brick size (58×61mm), and recorded an 84% efficiency and 4% voltage regulation for the entire input voltage range, thereby demonstrating its application potentials to future telecommunication electronics.

Current Controlled PWM Inverter Using Reduced-Order State Observer (최소 차원 상태 관측기를 사용한 전류 제어형 PWM 인버터에 관한 연구)

  • Kim, J.S.;Lee, C.D.;Park, O.S.;Choi, S.Y.;Kim, Y.C.;Woo, J.I.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.300-302
    • /
    • 1995
  • This paper describes a current control method for a single-phase PWM inverter. The proposed PWM inverter utilizes the instantaneous control method which is based on the real-time digital feedback control and the microprocessor-based deadbeat control. For the deadbeat current controller, the system's order becomes a high order and increases computation delay time. Therefore, The delay time produces current ripple. To minimize the current ripple, a new method based on deadbeat control theory for current regulation is proposed. It is constructed by a reduced-order state observer which predicts the output current in next sampling instant.

  • PDF

Current Controlled PWM for Multilevel Voltage-Source Inverters with Variable and Constant Switching Frequency Regulation Techniques: A Review

  • Gawande, S.P.;Ramteke, M.R.
    • Journal of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.302-314
    • /
    • 2014
  • Due to advancements in power electronics and inverter topologies, the current controlled multilevel voltage-source pulse width modulated (PWM) inverter is usually preferred for accurate control, quick response and high dynamic performance. A multilevel topology approach is found to be best suited for overcoming many problems arising from the use of high power converters. This paper presents a comprehensive review and comparative study of several current control (CC) techniques for multilevel inverters with a special emphasis on various approaches of the hysteresis current controller. Since the hysteresis CC technique poses a problem of variable switching frequency, a ramp-comparator controller and a predictive controller to attain constant switching frequency are described along with its quantitative comparison. Furthermore, various methods have been reviewed to achieve hysteresis current control PWM with constant switching frequency operation. This paper complies various guidelines to choose a particular method suitable for application at a given power level, switching frequency and dynamic response.