• 제목/요약/키워드: Current Reference Signal

검색결과 206건 처리시간 0.042초

BLDC 전동기를 사용한 전기 스쿠터 개발 (An electric scooter development using BLDC motor)

  • 박성욱;이득기
    • 전기학회논문지P
    • /
    • 제51권4호
    • /
    • pp.219-221
    • /
    • 2002
  • This paper presents an electric scooter development using blushless DC motor. In recent scooters was to develop for sport leisure and short transportation. Most of scooter are used petroleum gas. This gas scooter has disadvantage to pollute the air. Some of scooters have developed by DC motor which require a brush. However brushless motors have higher maximum speed and greater capacity, save maintenance labour and produce less noise. There is also greater freedom in planing the usage of brushless motors. In this paper we develop an electric scooter driving BLDC motor for design smart system and control speed of scooter with current reference signal to apply voltage to motor by means of three phase inverter. Using accelerator device we generate current reference to control speed and send the current to a MICOM by A/D converter. This MICOM produces the voltage signal and hall sensors signal and PWM controller drive three phase inverter to minimize error between the reference and an actual current.

단상 전원 고조파 제거 시스템을 위한 기준전류 생성회로에 대한 연구 (A Study of the Current Reference Signal Generation Circuit for Single-Phase Harmonic Elimination Systems)

  • 정동열;박종연;김상훈;최원호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권7호
    • /
    • pp.335-342
    • /
    • 2005
  • This paper presents a circuit to generate the current reference signal for single-phase harmonic elemination systems. Some of conventional methods for the current reference signal generation based on neural network algorithms. It requires complex circuitry to implement. the simplest method is to use analog filters. but it is difficult to obtain good current reference signals. So, we propose the harmonic detection circuit using GIC(Generalized Impedance Converter) for the purpose of low cost ,simple circuitry and high performance, Simulation and experimental results verify that the proposed circuit has better harmonic detection performance than conventional circuit.

자성체포화를 이용한 DC전류센서 (DC Current sensor using the saturable magnetic cores)

  • 박영태
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.699-702
    • /
    • 2002
  • A DC current sensor is disclosed in which two pairs of saturable cores are provided so as enclose a conductor carrying a direct current to be measured. On each of the saturable cores, a bias winding, a feedback winding and an output winding are wound. Circuit for detection of an asymmetry in the magnetization current, generated by a reference alternating voltage, in a signal-conditioner. The reference alternating voltage is fed to the respective series circuits such that no resultant induction current is induced in the modulating current. The voltages over the resistor form input signals for two peak value detectors, the strength of the output signal of which represents the degree of asymmetry of magnetization current. This paper describes the development a DC current sensor and its signal-conditioner.

  • PDF

멀티레이트 신호처리와 동적 래이턴스 보정에 의한 단일 응답 유발전위 뇌파 추출 (Estimation of single-trial event-related potentials using multirate signal processing latency compensation)

  • 이용희;이두수
    • 전자공학회논문지S
    • /
    • 제34S권12호
    • /
    • pp.60-69
    • /
    • 1997
  • We present an average method based on the multirate signal processing and dynamic allocation average for the purpose of monitoring event-related potentials(ERP) and continuously and dynamically. In the proposed method, first, latency shifts are detected through the cross correlation between a current response and the reference response. Then, the multirate signal processing which is composed of up-sampler, lowpass filter, and down sampler is performed to compensate the latency shifts of the reference response, therefore we obtain the reference response with a peak latencies compenated by those of a current response. Finally, the single response is obtained by averaging the compensated reference response and a current response. In the simulation, the results of quantitative evaluation by simulation and the results using linical data are presented. From the result, the proposed method reflects dynamic time-varying ERP more exactly than previous methods and is also effective in consecutive monitoring of ERP.

  • PDF

IPMSM의 맥동하는 구형파 신호 주입 센서리스 제어를 위한 정지좌표계상에서의 새로운 위치 추정 기법 (A Novel Rotor Position Estimation Method using a Rotation Matrix for a Square-Wave Signal Injected Sensorless Control in IPMSM)

  • 김상일;김래영
    • 전력전자학회논문지
    • /
    • 제21권3호
    • /
    • pp.215-223
    • /
    • 2016
  • In this study, a novel rotor position sensorless estimation method of an interior permanent-magnet synchronous motor is proposed. A square-wave pulsating voltage signal is injected in the estimated synchronous reference frame. This signal is interpreted in the stationary reference frame regardless of the estimated rotor position. Thus, assuming that the position error is nearly zero is unnecessary because the variables in the estimated synchronous reference frame are not used. The rotor position can be exactly calculated from two voltage references and three sampled current feedbacks in the stationary reference frame. The proposed method is easy to implement and helps enhance the bandwidth of the current controller. The validity of the proposed method is verified by simulations and experiments.

능동전력필터의 정밀 기준신호 발생기 (Accurate Current Reference Generator for Active Power Filters)

  • 배병열;전영수;한병문;소용철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(2)
    • /
    • pp.575-578
    • /
    • 2004
  • The performance of an active power filter(APF) depends on the inverter characteristic, the control method, and the accuracy of reference signal generator. The accuracy of reference generator is the most critical item to determine the performance of active power filter. This paper introduces a novel reference signal generator composed of improved adaptive predictive filter. The performance of proposed reference signal generator was first verified through a simulation with MATLAB. Furthermore, the application of feasibility was evaluated through experimenting with a single-phase APF prototype based on the proposed reference generator, which was implemented using the TMS320C31 floating-point signal processor. Both simulations and experimental results confirm that our reference signal generator can be used successfully in practical active power filters.

  • PDF

A Novel Parameter-independent Fictive-axis Approach for the Voltage Oriented Control of Single-phase Inverters

  • Ramirez, Fernando Arturo;Arjona, Marco A.;Hernandez, Concepcion
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.533-541
    • /
    • 2017
  • This paper presents a novel Parameter-Independent Fictive-Axis (PIFA) approach for the Voltage-Oriented Control (VOC) algorithm used in grid-tied single-phase inverters. VOC is based on the transformation of the single-phase grid current into the synchronous reference frame. As a result, an orthogonal current signal is needed. Traditionally, this signal has been obtained from fixed time delays, digital filters or a Hilbert transformation. Nevertheless, these solutions present stability and transient drawbacks. Recently, the Fictive Axis Emulation (FAE) VOC has emerged as an alternative for the generation of the quadrature current signal. FAE requires detailed information of the grid current filter along with its transfer function for signal creation. When the transfer function is not accurate, the direct and quadrature current components present steady-state oscillations as the fictive two-phase system becomes unbalanced. Moreover, the digital implementation of the transfer function imposes an additional computing burden on the VOC. The PIFA VOC presented in this paper, takes advantage of the reference current to create the required orthogonal current, which effectively eliminates the need for the filter transfer function. Moreover, the fictive signal amplitude and phase do not change with a frequency drift, which results in an increased reliability. This yields a fast, linear and stable system that can be installed without fine tuning. To demonstrate the good performance of the PIFA VOC, simulation and experimental results are presented.

소프트웨어 PLL 기반 소형 고속 BLDC의 속도 제어 (Software PLL Based Speed Control of High Speed Miniature BLDC)

  • 박태흡;석승훈;이동희;안진우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.132-135
    • /
    • 2008
  • This paper presents a PLL(Phase Lock Loop) control method for speed control of high speed miniature BLDCM(Brushless DC Motor) using hall sensor. The Proposed PLL based speed control method uses a only phase shift between reference pulse signal according to speed reference and actual pulse signal from hall sensor. It doesn't use any speed calculation, and calculates a direct current reference from phase shift. The current reference is changed to reduce the phase shift between reference and actual pulse. So the actual speed can keep the reference speed. The proposed control scheme is very simple but effective speed control is possible.

  • PDF

권선 단선 고장 DC 모터의 진단 (Diagnosis for Winding Open Fault of DC Motor)

  • 양철오;표연준;김준영;박규남;송명현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2073-2074
    • /
    • 2011
  • In this study, an algorithm for diagnosis of dc motor with winding open fault is suggested. A dc motor used in this paper, is consisted of a permanent magnet field stator, double 16-turn series winding rotating armature with 12-slot, brush and 12-commutator, etc. A current signal of dc motor which has brushes and commutatorswas considered for fault diagnosis. By commutation, this current signal shows different wave form according to the fault condition of the motor. In this study, operation of the data was easily through simplification of the current signal by the signal processing. Computation method is presented reference value($C_{dv}$) for diagnosis of winding open fault and verified through experiments that can be diagnosed using the reference value($C_{dv}$).

  • PDF