• 제목/요약/키워드: Current Control System

검색결과 5,085건 처리시간 0.032초

SAW 용접시 다중 토치를 이용한 용접부 적응제어에 관한 연구 (A Study on Adaptive Control to Fill Weld Groove by Using Multi-Torches in SAW)

  • 문형순;정문영;배강열
    • Journal of Welding and Joining
    • /
    • 제17권6호
    • /
    • pp.90-99
    • /
    • 1999
  • Significant portion of the total manufacturing time for a pipe fabrication process is spent on the welding following primary machining and fit-up processes. To achieve a reliable weld bead appearance, automatic seam tracking and adaptive control to fill the groove are urgently needed. For the seam tracking in welding processes, the vision sensors have been successfully applied. However, the adaptive filling control of the multi-torches system for the appropriate welded area has not been implemented in the area of SAW(submerged arc welding) by now. The term adaptive control is often used to describe recent advances in welding process control by strictly this only applies to a system which is able to cope with dynamic changes in system performance. In welding applications, the term adaptive control may not imply the conventional control theory definition but may be used in the more descriptive sense to explain the need for the process to adapt to the changing welding conditions. This paper proposed various types of methodologies for obtaining a good bead appearance based on multi-torches welding system with the vision system in SAW. The methodologies for adaptive filling control used welding current/voltage, arc voltage/welding current/wire feed speed combination and welding speed by using vision sensor. It was shown that the algorithm for welding current/voltage combination and welding speed revealed sound weld bead appearance compared with that of voltage/current combination.

  • PDF

항공관제용 정전류조정(CCR) 인버터 시스템의 개발 (A Constant Current Regulated Inverter System for Lighting and Beaconing of Aerodromes)

  • 손진근;박종찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.141-146
    • /
    • 2006
  • According as level of industry develops day after day, electricity load system of industry requires high level control, effectiveness and high efficiency. Among supply and control unit of suitable power supply in these load characteristic, inverter systems of constant current regulate is used widely control of lighting and electric heating system. Therefore, in this paper proposed an inverter systems with constant current regulation and power factor correction (PFC) circuit for Lighting and Beaconing of Aerodromes. The effectiveness of the proposed system confirmed through experimental results of CCR.

  • PDF

자율분산 역 제어시스템 모의시험 연구 (A study on the simulation test of Autonomous station control system)

  • 김영훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.2045-2050
    • /
    • 2008
  • The Autonomous station control system by applying the concepts of autonomous decentralized system is a system which can solve the problems of the current central control system. The Autonomous station control system tester developed in order to test for Autonomous station control system. The main function of tester is a time-deadline test, a schedule broadcast test, a route control test and a version-up test, etc. In the paper, we build the reliability of the Autonomous station control system by testing the Autonomous station control system tester. Also, the test enable the on-line test without the system interruption and verify the function of the Autonomous station control system developed by applying the concepts of Autonomous decentralized system to the current Central control system.

  • PDF

An Effective Control Scheme for Battery Charger System in Electric Vehicles

  • Nguyen, Cong-Long;Lee, Hong-Hee
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.232-233
    • /
    • 2012
  • This paper presents an effective control scheme for an electric vehicle battery charger where a symmetrical bridgeless power factor-corrected converter and a buck converter are cascaded. Both converters have been popular in industries because of their high efficiency, low cost, and compact size, hence combining these converters makes the overall battery charging system strongly efficient. Moreover, this charger topology can operate at universal input voltage and attain a desired battery current and voltage without ripple. In order to achieve a unity input power factor and zero input current harmonic distortion, the proposed control scheme adopts duty ratio feed-forward control technique in both current and voltage control loop. Additionally, in the current loop, its reference is created by a phase-locked loop (PLL) block, leading to a pure sinusoidal input current although the input voltage waveform is being distorted. The feasibility and practical value of the proposed approach are verified by simulation and experiment with an 110V/60Hz ac line input and 1.5kW-72V dc output of the battery charging system.

  • PDF

부하 전류식 전류형 인버터-유도전동기 시스템의 속도제어에 관한 연구 (A Study on the Speed Control of LCCSI-Induction Motor System)

  • 임재열;이승철;정승기;송중호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.283-286
    • /
    • 1994
  • A speed control system of the induction motor drives by the load commutated current source inverter is studied in this paper. In general, since the rotating equipments such as pumps, fans and blowers do not require necessarily the accurate speed control performance, a voltage control and a speed sensorless vector control systems are mainly used for this application. In this paper, a new control scheme which has better performance than the voltage control system and simpler control structures than the vector control system is presented. This new proposed method controls the angle of the current vector using the relationship between the inverter output voltage and current, as well as uses the simple method to compensate the effect of the output capacitors.

  • PDF

열차 추진제어장치의 알고리즘에 관한 연구 (A Study of Control Algorithm for Propulsion System)

  • 최재호;김형철
    • 한국철도학회논문집
    • /
    • 제10권1호
    • /
    • pp.51-56
    • /
    • 2007
  • In this paper, control schemes are developed for a propulsion system(Converter/Inverter) in electrical train. A robust controller for PWM converter is proposed. The converter controller consists of a PI controller for DC output voltage and a current controller using error-space approach for maintaining the sinusoidal current waveform and unity power factor. This proposed method is based on characteristic ratio assignment(CRA) method which has the advantage to design the optimal gain to meet the referenced response and overshoot within the limit range. Inverter system is controlled by vector control and slip frequency control. At low speed region, vector control scheme is applied to control instantaneous torque and slip frequency control is performed under overmodulation region and one pulse mode. Because output voltage of converter contains harmonics ripple at twice input ac line frequency, control scheme is developed to reduce the pulsating torque current. The performance of propulsion system will be verified by simulation and prototype experimental results.

KSTAR 전류전송제어시스템의 원격운전을 위한 EPICS 기반 제어계 구축 (Implementation of EPICS based control system for KSTAR Current Lead System)

  • 김명규;백설희;김국희;박미경
    • 한국진공학회지
    • /
    • 제17권1호
    • /
    • pp.58-66
    • /
    • 2008
  • KSTAR 전류전송제어시스템은 네트워크기반의 실시간 분산제어시스템으로 EPICS (Experimental Physics and Industrial Control System)를 미들웨어로 채용하여 구축하였다. 전류전송제어시스템은 초전도자석시스템에 전류를 전송하기 위한 시스템으로서 전류전송과 동시에 초전도자석이 초전도상태를 유지하기 위한 냉매의 전송도 담당하고 있다. 주제어실에서의 원격운전을 위하여 EPICS IOC(Input Output Controller) 서버를 현장에 설치하였고 이를 통하여 전류전송제어시스템은 고유의 이름(PV)에 적절한 조작 및 감시 명령을 부여하여 주제어실의 운전화면을 통하여 시스템의 감시 및 조작이 가능하도록 하였다. EPICS와 PLC의 통신을 위하여 ether-ip 드라이버를 이용하여 EPICS IOC를 구축하였으며, 시험 결과 안정성 및 운용성 측면에서 만족할 만한 결과를 획득하였다.

유도전동기 벡터제어 시스템의 시간지연 보상 (Time Delay Compensation of Induction Motor Vector Control System)

  • 박철우;최연호;임성운;윤경섭;권우현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.231-231
    • /
    • 2000
  • It is proposed that a novel method which can compensate the time delay occurs in overall system, when voltage and current is measured, owing to LPF, hysteresis control inverter and microprocessor program computation time. The Proposed scheme estimates the time delay using the difference between Q-axis stator current command and time delayed Q-axis stator current in synchronous reference frame, and compensates the time delay of voltage and current using angular displacement of DQ transformation. The proposed scheme compensates accurately the time delay occurs in overall system. Therefore performance of vector control system is improved highly and it is verified by simulation and experiment.

  • PDF

A Decentralized Optimal Load Current Sharing Method for Power Line Loss Minimization in MT-HVDC Systems

  • Liu, Yiqi;Song, Wenlong;Li, Ningning;Bai, Linquan;Ji, Yanchao
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2315-2326
    • /
    • 2016
  • This paper discusses the elimination of DC voltage deviation and the enhancement of load current sharing accuracy in multi-terminal high voltage direct current (MT-HVDC) systems. In order to minimize the power line losses in different parallel network topologies and to insure the stable operation of systems, a decentralized control method based on a modified droop control is presented in this paper. Averaging the DC output voltage and averaging the output current of two neighboring converters are employed to reduce the congestion of the communication network in a control system, and the decentralized control method is implemented. By minimizing the power loss of the cable, the optimal load current sharing proportion is derived in order to achieve rational current sharing among different converters. The validity of the proposed method using a low bandwidth communication (LBC) network for different topologies is verified. The influence of the parameters of the power cable on the control system stability is analyzed in detail. Finally, transient response simulations and experiments are performed to demonstrate the feasibility of the proposed control strategy for a MT-HVDC system.

브러시리스 전동기의 저속 서어보 시스템 (Low Speed Servo System for Brushless Motor)

  • 이운영;이공원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.162-164
    • /
    • 1994
  • This paper proposes a servo control system of brushless motor at a low and high speed range. The control system is composed of the PI controller for high-speed control and the modified PI controller for low-speed control and the current controller using the hysteresis current control PWM method. The speed control performance is shown by the computer simulation.

  • PDF