• 제목/요약/키워드: Current Control System

검색결과 5,077건 처리시간 0.04초

상간리액터 없는 병렬연결 듀얼컨버터 시스템의 동작해석과 새로운 전류제어 (Operation Analysis and New Current Control of Parallel Connected Dual Converter System without Interphase Reactors)

  • 지준근
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권7호
    • /
    • pp.488-493
    • /
    • 2000
  • In this paper, a predictive current control of 12-pulse parallel connected dual converter system without interphase reactors(IPR) is presented. Firstly, the characteristics of system without IPR are analyzed and compared with that of system with IPR. And the predictive current control of this system is discussed. Finally the validity of the presented system and the excellence of the predictive current control response is proved through the simulation results and experimental results.

  • PDF

Y 결선된 7상 BLDC 전동기의 구형파 전류 제어를 위한 새로운 전류 제어방식에 관한 연구 (A Study on New Current Control Method for Square Current Wave in Y Connected 7-Phase BLDC Motor Drive System)

  • 문종주;이원;김장목
    • 전기학회논문지
    • /
    • 제65권4호
    • /
    • pp.576-585
    • /
    • 2016
  • The current control methods of Y-connected 7 Phase BLDC motor are sine wave current control and square wave control. The sine wave current control method needs dq axis transformation of $7{\times}7$ matrix for current control and very complex. Also this method is not suitable for multi Phase BLDC motor of trapezoidal back emf wave. Therefore, in Y connected multi phase BLDC motor, the square wave current control methods are required. Generally, in the 3Phase BLDC system, Average current control method is used for current control. The average current is obtained that the summation of absolute value of each phase current magnitude is divided by the number of conduction phase. However, if average current control method is applied to multi-phase system, there is a problem that each phase currents are different. This problem affects unbalance of each phase torque and fluctuation of total torque. This paper proposed each phase current control method of Y connected 7Phase BLDC system. Proposed method is used for PI controller of each phase for each phase current control. This method can perfect square wave current control. Also, configuration of the method is easier than DQ axis transformation. Proposed method is verified through simulation and experiments.

PI 제어기의 내부원리를 이용한 PWM AC-DC 컨버터의 새로운 전류제어 (Novel current control for PWM AC-DC converter using internal principle of PI controller)

  • 허태원;황영민;김영빈;이현우;우정인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.1944-1946
    • /
    • 1998
  • This paper presents a novel current control system to eliminate the steady state control error for PWM AC-DC converter. A general mathematical model of the converter which is represented as a state-space model is established. The state-space model is used for the simulation of converter with the proposed tracking control system of sinusoidal current. In this system, a novel current control which do not require coordinate transformations using internal principle of PI controller is described. It is proved that the steady state deviation reduce to zero through a transfer function of source current control system. Finally, simulations show good source current control characteristics by means of a simplified control system which do not require coordinate transformations.

  • PDF

무손실 공진기를 가지는 전압형 PWM 컨버터의 전원전류 제어에 관한 연구 (A Study on Source Current Control of Voltage Source PWM Converter based on Lossless Resonator)

  • 허태원;신덕웅;김구형;진해중;우정인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.2040-2042
    • /
    • 1997
  • A voltage source PWM converter based on lossless resonator and a source current control system are proposed in this paper. It is proved that steady-state deviation reduces to zero from the transfer function of source current control system, owing to the lossless resonator. The system can be controlled by the feedback control only, because of no need to use a feedforward control in the proposed a source current control system. Therefore, as using lossless resonator, control system can be simply made up. Simulations are described in the case of difference between source current and source current reference.

  • PDF

3차원 전류좌표계 해석법에 의한 DSP 전력분석 제어장치에 관한 연구 (A study on DSP based power analyzing and control system by analysis of 3-dimensional space current co-ordinates)

  • 임영철;정영국;나석환;최찬학;장영학;양승학
    • 대한전기학회논문지
    • /
    • 제45권4호
    • /
    • pp.543-552
    • /
    • 1996
  • The goal of this paper is to developed a DSP based power analyzing and control system by 3-Dimensional (3-D) space current co-ordinates. A developed system is made up of 486-PC and DSP (Digital Signal Processor) board, Active Power Filter, Non-linear thyristor load, and Power analyzing and control program for Windows. Power is analyzed using signal processing techniques based on the correlation between voltage and current waveforms. Since power analysis algorithm is performed by DSP, power analysis is achieved in real-time even under highly dynamic nonlinear loading conditions. Combining control algorithm with power analysis algorithm is performed by DSP, power analysis is achieved in real-time even under highly dynamic nonlinear loading conditions. Combining control algorithm with power analysis algorithm, flexibility of the proposed system which has both power analysis mode and control mode, is greatly enhanced. Non-active power generated while speed of induction motor is controlled by modulating firing angle of thyristor converter, is compensated by Active Power Filter for verifying a developed system. Power analysis results, before/after compensation, are numerically obtained and evaluated. From these results, various graphic screens for time/frequency/3-D current co-ordinate system are displayed on PC. By real-time analysis of power using a developed system, power quality is evaluated, and compared with that of conventional current co-ordinate system. (author). refs., figs. tabs.

  • PDF

전동기 시스템의 미지외란 및 전류 관측기 설계 (Design of Unknown Disturbance and Current Observer for Electric Motor Systems)

  • 이명석;정경모;공경철
    • 제어로봇시스템학회논문지
    • /
    • 제21권7호
    • /
    • pp.615-620
    • /
    • 2015
  • DOB (Disturbance Observer) is an useful control method for estimating the disturbance applied to dynamic systems. Disturbance observer can be used to implement a robust control system to generate a control input for rejecting the disturbance, and it can be also used to estimate the disturbance to obtain information. The system that uses disturbance estimation is investigated for high performance control such as automatic door systems, walking robot and electric power steering system in vehicles. In this paper, a novel disturbance observer which is called disturbance and current observer for estimating load torque in the motor system is proposed. The difference between the DOB for disturbance rejection and DCOB is mathematically verified. Current and angular velocity are required for estimating the load torque of the motor in DOB. However, the DCOB can estimate load torque and current without current sensor. DCOB is designed based on modeling of the motor system. Appropriate Q-filter is selected and the applicability of DCOB is verified by simulation. The estimated disturbance and current of the electric motor can be verified without current sensor, as experiments of the actual motor system.

12펄스 병렬 연결 듀얼 컨버터 시스템의 예측전류제어 (Predictive Current Control of 12-Pulse Parallel Connected Dual Converter System)

  • 이창원;송인호;최창호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.405-408
    • /
    • 1998
  • In this paper, a predictive current control of 12-pulse parallel connected dual converter system with interphase transfromer(IPT) is presented. Firstly, 12-pulse parallel connected dual converter system and the predictive current control of this system is discussed. And the validity of the presented system and the excellence of the predictive current control response is proved through the simyulation and experiment result.

  • PDF

CURRENT CONTROL FOR PWM AC-DC CONVERTER USING SINUSOIDAL TRACKING CONTROLLER

  • Woo, Jung-In;Heo, Tae-Won;Lee, Hyun-Woo;Kim, Choon-Sam;Jung, Yung-Il
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.928-933
    • /
    • 1998
  • This paper presents a novel current control system to eliminate the steady state control error and to improve the transient characteristics for PWM AC-DC converter. A general mathematical model of the converter that is represented as a state-space model is first established. The state-space model is used for the simulation of PWM switching converter with the proposed current control system. The proposed sinusoidal tracking control system that does not require coordinate transformations using principle of the integral controller is described. It is proved that the steady state deviation reduces to zero through a transfer function of source current control system. Finally, it is seen that simulations agree with the experimental results in source current and reference of controlled ac current loop.

  • PDF

원자로 제어봉구동장치 제어시스템의 전력변환기 사이리스터 고장 검출 (Fault Detection for thyristors of Power Converter Module in Control Rod Control System)

  • 김춘경;천종민;이종무;정순현;권순만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.559-562
    • /
    • 2003
  • In this paper, we introduce a new method detecting thyristor faults of the power converter module in Control Rod Control System. When we control the currents in each coil of Control Rod Drive Mechanism by using the current control method, the current value can follow the current reference despite the faults like the missing phase or the diode acting. Comparing the fault current values with the normal current values, the bad transient characteristics of the abnormal current can make the operations of control rods incorrect. In this case, the information from the current trends cannot be enough to detect the fault occurrence in thyristors. Instead of the coil currents, the state of thyristors can be watched by measuring the coil voltages. In the existing system of Westinghouse type, the ripple detector takes charge of this task. But this detector has some shortcomings in the point of time for fault detection, we come to devise a new fault detection method solving the problems which belong to the ripple detector.

  • PDF

전류공유버스를 이용한 병렬 인버터 순시 제어기 설계 (Instantaneous Current Control for Parallel Inverter with a Current Share Bus)

  • 이창석;김시경
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.90-94
    • /
    • 1998
  • The parallel inverter is popularly used because of its fault-tolerance capability, high-current outputs at constant voltages and system modularity. The conventional parallel inverter usually employes active and reactive power control or frequency and voltage droop control. However, these approaches have the disadvantages that the response time of parallel inverter control is slow against load and system parameter variation to calculate active, reactive power, frequency and voltage. This paper describes a novel control scheme for power equalization in parallel connected inverter. The proposed scheme has a fast power balance control response, a simplicity of implementation, and inherent peak current limiting capability since it employes a instantaneous current/voltage control with output voltage and current balance and output voltage regulation. A design procedure for the proposed parallel inverter controller is presented. Futhermore, the proposed control scheme is verified through the simulation in various cases such as the system parameter variation, the control parameter variation and the nonlinear load condition.

  • PDF