• Title/Summary/Keyword: Current Cancelation

Search Result 16, Processing Time 0.024 seconds

3 Dimensional Mobile Phone Internal Antenna Using the Helix Element (헤릭스를 이용한 3차원 구조의 휴대폰 내장형 안테나)

  • Hong, Min-Gi;Son, Tae-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.8
    • /
    • pp.906-912
    • /
    • 2008
  • We designed and implemented a 3-dimensional structure internal antenna which has volume less than 1.5 cc for mobile phone to improve efficiency and gain. Multiple bending for the resonance of small internal antenna derives reduction of gain due to cancellation of antenna current. In this study, the current cancelation was reduced by the minimization of antenna bending. And the helix element was applied for the purpose both compensation of short antenna length and action of radiation element. For the verification of this study, a 1.5 cc volume 3D antenna which was fabricated by the press method applied to the dual band mobile phone. Measurement showed that efficiencies and gains under the slide down and up were 27.73 %, 0.29 dBi for the GSM band and 46.84 %, 2.27 dBi for the USPCS band, and had good performance under the small antenna volume. H-plane radiation pattern showed omnidirectional for the both band.

Design and Control of Interleaved Boost converter for Multi-string PV Inverter (멀티스트링 태양광 인버터용 인터리브드 부스트 컨버터의 설계 및 제어)

  • Kang, Young-Ju;Cha, Han-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.3
    • /
    • pp.538-543
    • /
    • 2011
  • In this paper, design and control of an interleaved boost converter for multi-string PV Inverter are discussed. Interleaved Boost converter can reduce current ripples at input and output side by cancelling an each phase of inductor currents. Therefore, it contributes to increase efficiency and downsize the whole system volume, cost. One of the advantages of the multi-string system is easy to expand power capacity by connecting the converter modules in parallel. In order to reduce current ripples, the inductor currents on each phase are controlled independently in the converter module, and communication between the converter modules is required for further ripple current reduction. Current control algorithm for the balance of the each phase ripple currents and synchronization of the converter modules based on communication are proposed and implemented in the DSP programming. 10kW prototype of the multi-string converter module is assembled and experimental results are presented to verify the proposed ripple current reduction methods.

Harmonic Analysis of Thrust Force depended on 2 Phase 8 Pole HB Type LPM Drive Method (2상8극 HB형 LPM의 구동방식에 따른 추력의 고조파 해석)

  • Kim, Sung-Heon;Lee, Eun-Woong;Kim, Il-Jung;Lee, Dong-Ju
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.228-231
    • /
    • 1996
  • In this paper, we calculate the thrust force by the permeance method. we analyze the thrust force vs. displacement and harmonic components of static thrust characteristics of LPM. Microstep reference current for cancelation of the dominent harmonic component is obtained by the analytical method.

  • PDF

Analysis of Operational Modes in Integrated Three-Phase Flux-Lock Type Superconducting Fault Current Limiting (일체화된 삼상 자속구속형 고온초전도 전류제한기의 동작모드 분석)

  • Park, Chung-Ryul;Du, Ho-Ik;Choi, Hyo-Sang;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.186-187
    • /
    • 2006
  • The development of SFCL (Superconducting Fault Current Limiter) is getting more important as the power demand is increased rapidly. Up to now, several kinds of SFCL have been proposed and it is expected that they will be applied to appropriate position considering their own properties. Amongst those proposed SFCL, flux-lock type SFCL using the magnetic cancelation for current limiting has the advantages of overcoming the technical difficulties that other types of SFCLs have. In this paper, the integrated three-phase flux-lock type SFCL was fabricated and its operational modes were investigated through the short circuit tests. The operational mode were to divided into four mode according to the variation of the currents flowing into the secondary winding connected the superconducting elements and the speed of the quench generation. It was expected that the improvement of current limiting characteristics of the SFCL could be possible through control of the operational mode.

  • PDF

Analysis of Shielding Effectiveness and Estimation of Shielding Factor in Conductive and Magnetic Shields (도전성 및 자성 차폐체의 차폐효과 해석과 차폐인수 산정)

  • Kang, Dae-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.10
    • /
    • pp.30-40
    • /
    • 2013
  • In this study the method based on flux linkage in cell was introduced in calculation of eddy currents by cell method. According to this method eddy current distribution and the loss can be evaluated and since the shielding effectiveness by flux cancelation of eddy current can be analyzed, this method is applicable to design of conductive shield. And also the formula of shielding factor were so deduced as to be applicable to finite-width infinite-length shielding sheets and infinite-length underground cable shield. These formula are adaptable to magnetic materials as well as conductive materials. As the results of calculation in model shields are follows. In case of finite-width infinite-length shielding sheet, shielding effectiveness increases with increasing of conductivity. In case of infinite-length underground cable shield, the effectiveness become higher with increasing of permeability. Especially the effectiveness is very high in materials with both high conductivity and permeability in underground cable shield.

A High Efficient, Two-Stage Interleaved Synchronous Buck CMOS DC-DC Converter (고효율 2단 인터리브 동기정류형 벅 컨버터)

  • Park, Jong-Ha;Kim, Hoon;Kim, Hee-Jun
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1069-1070
    • /
    • 2008
  • This paper presents a high efficient two-stage interleaved synchronous buck CMOS DC-DC converter. The proposed circuit has a fixed duty cycle as 0.5 by an added buck converter. And it causes the best ripple cancelation of the output current ripple. The proposed circuit was simulated by HSPICE with a standard CMOS $0.35{\mu}m$ process parameter.

  • PDF

Article - 환기.방재측면에서의 초장대.대심도 터널에 관한 고찰

  • Lee, Hang
    • Journal of the Korea Construction Safety Engineering Association
    • /
    • s.54
    • /
    • pp.41-55
    • /
    • 2011
  • The current railway projects under plan, design, or construction have been designed as 'very long and deep underground tunnel'. Therefore, it is reasonable that the standards for preventing disaster in such conditions should be intensified in order to avoid repeating the same failure which happened in Daegu subway disaster, Although we consent to the opinion that nothing can compete with human being's life, it is very difficult to protect the life from all of potential disasters perfectly in railway fields because the excessive standards can result in excess construction cost, which can bring about cancelation of the project itself eventually. Therefore optimized disaster design standard is required to negotiate the conflict between economical cost and social tolerance limitation simultaneously.

  • PDF

dB-Linear CMOS Variable Gain Amplifier for GPS Receiver (dB-선형적 특성을 가진 GPS 수신기를 위한 CMOS 가변 이득 증폭기)

  • Jo, Jun-Gi;Yoo, Chang-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.7
    • /
    • pp.23-29
    • /
    • 2011
  • A dB-linearity improved variable gain amplifier (VGA) for GPS receiver is presented. The Proposed dB-linear current generator has improved dB-linearity error of ${\pm}0.15$dB. The VGA for GPS is designed using proposed dB-linear current generator and composed of 3 stage amplifiers. The IF frequency is assumed as 4MHz and the linearity requirement of the VGA for GPS receiver is defined as 24dBm of IIP3 using cascaded IIP3 equation and the VGA satisfies 24dBm when minimum gain mode. The DC-offset voltage is eliminated using DC-offset cancelation loop. The gain range is from -8dB to 52dB and the dB-linearity error satisfies ${\pm}0.2$dB. The 3-dB frequency has range of 35MHz~106MHz for the gain range. The VGA is designed using 0.18${\mu}m$ CMOS process. The power consumption is 3mW with 1.8V supply voltage.

Fabrication of a Subminiature 3 Dimensional Antenna for the Mobile Phone Handset (이동 통신 단말기용 초소형 3차원 안테나 제작)

  • Hong, Min-Gi;Son, Tae-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.12
    • /
    • pp.1455-1461
    • /
    • 2008
  • We implemented a subminiature internal antenna that is around 1 cc volume for the mobile phone. The fundamental type of studied antenna is IFA(Inverted F Antenna), and this antenna is designed to be improved efficiency and gain due to minimum current cancellation by the avoidance of multiple bending pattern. For the implementation of multiple band, helix is applied to compensate for short antenna length for low frequency band, and a 3 dimensional pattern is used for high frequency band. We made two kinds of 3D structure antenna. One is a 1 cc volume antenna for GSM/DCS band on the bare board set, and the other is a 1.5 cc volume for the GSM/USPCS mobile phone set. Measurements showed good gain performance that average gain of two antenna on each band are $-3.46{\sim}-0.45\;dBi$ and $-4.80{\sim}-3.29\;dBi$ respectively.

Semisubmersible platforms with Steel Catenary Risers for Western Australia and Gulf of Mexico

  • Zou, Jun
    • Ocean Systems Engineering
    • /
    • v.2 no.2
    • /
    • pp.99-113
    • /
    • 2012
  • Steel Catenary Risers (SCR) are the simplest and often the most economic solution compared to other riser types such as flexible pipe, riser towers, top tensioned risers, etc. The top of a SCR is connected to the host platform riser porch. The other end of the SCR connects to flowlines from subsea wells. The riser touchdown point (TDP), which is the location along the riser where contact with the sea floor first occurs, exhibits complex behaviors and often results in compression and fatigue related issues. Heave dynamic responses of semisubmersibles in extreme and operating sea states are crucial for feasibility of SCR application. Recent full field measurement results of a deep draft semisubmersible in Hurricane Gustav displayed the considerable discrepancies in heave responses characteristics between the measured and the simulated results. The adequacy and accuracy of the simulated results from recognized commercial software should be examined. This finding raised the awareness of shortcomings of current commercial software and potential risk in mega investment loss and environmental pollutions due to SCR failures. One main objective of this paper is to attempt to assess the importance and necessity of accounting for viscous effects during design and analysis by employing indicator of viscous parameter. Since viscous effects increase with nearly third power of significant wave height, thus newly increased metocean criteria per API in central Gulf of Mexico (GoM) and even more severe environmental conditions in Western Australia (WA) call for fundamental enhancements of the existing analysis tools to ensure reliable and robust design. Furthermore, another aim of this paper is to address the impacts of metocean criteria and design philosophy on semisubmersible hull sizing in WA and GoM.