• 제목/요약/키워드: Curing mode

검색결과 97건 처리시간 0.023초

Shear bond strength between CAD/CAM denture base resin and denture artificial teeth when bonded with resin cement

  • Han, Sang Yeon;Moon, Yun-Hee;Lee, Jonghyuk
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권5호
    • /
    • pp.251-258
    • /
    • 2020
  • PURPOSE. The bond strengths between resin denture teeth with various compositions and denture base resins including conventional and CAD/CAM purposed materials were evaluated to find influence of each material. MATERIALS AND METHODS. Cylindrical rods (6.0 mm diameter × 8.0 mm length) prepared from pre-polymerized CAD/CAM denture base resin blocks (PMMA Block-pink; Huge Dental Material, Vipi Block-Pink; Vipi Industria) were bonded to the basal surface of resin teeth from three different companies (VITA MFT®; VITA Zahnfabrik, Endura Posterio®; SHOFU Dental, Duracross Physio®; Nissin Dental Products Inc.) using resin cement (Super-Bond C&B; SUN MEDICAL). As a control group, rods from a conventional heat-polymerizing denture base resin (Vertex™ Rapid Simplified; Vertex-Dental B.V. Co.) were attached to the resin teeth using the conventional flasking and curing method. Furthermore, the effect of air abrasion was studied with the highly cross-linked resin teeth (VITA MFT®) groups. The shear bond strengths were measured, and then the fractured surfaces were examined to analyze the mode of failure. RESULTS. The shear bond strengths of the conventional heat-polymerizing PMMA denture resin group and the CAD/CAM denture base resin groups were similar. Air abrasion to VITA MFT® did not improve shear bond strengths. Interfacial failure was the dominant cause of failure for all specimens. CONCLUSION. Shear bond strengths of CAD/CAM denture base materials and resin denture teeth using resin cement are comparable to those of conventional methods.

코어용 레진의 두께가 중합에 미치는 영향 (Influence of Thickness on the Degree of Cure of Composite Resin Core Material)

  • 권병철;박정원
    • Restorative Dentistry and Endodontics
    • /
    • 제31권5호
    • /
    • pp.352-358
    • /
    • 2006
  • 본 연구는 코어용 이중 중합 레진의 중합도에 미치는 두께의 영향과 빛이 감소된 깊은 와동에서 자가 중합에 의한 영향을 조사하고자 하였다. Luxacore Dual과 Luxacore Self (DMG Inc, Hamburg, Germany) 두 종류의 코어용 레진 수복재를 지름 10 mm, 두께가 2, 4, 6, 8 mm 의 Teflon mold에 주입하고 자가중합 시키거나 혹은 $500 mW/cm^2$의 광도로 제조자의 지시에 따라 중합 후 $37^{\circ}C$ 증류수에 24시간동안 저장하였다. 각 시편의 윗면과 아랫면에서 Knoop's hardness를 측정하였다. 결과는 ANOVA로 통계 분석 하였고 Tukey's test로 사후 검정하였다. Luxacore Self와 Luxacore Dual을 자가중합 시킨 군의 중합도는 두께에 따른 영향을 받지 않았다. Luxacore dual을 광중합한 경우 중합은 2 mm, 4 mm와 6 (적층충전) mm군에서는 밑면의 효과적인 중합이 일어났으나 8 (적층충전) mm군, 6, 8 (단일충전) mm군은 밑면에서 불완전한 중합을 보였다 (p < 0.05). 따라서 이 실험 결과에 의하면 4 mm를 초과하는 경우 단일충전보다 적층충전이 더 좋은 것으로 나타났다.

광위상변조기 제작용 Single Channel 및 1$^\circ$ Y-branch Mach-Zehnder간섭기형 Ti:LiNbO$_3$ 도파로 Pigtailing 및 도파실험 (Pigtailing and Guiding Experiments of Single and 1$^\circ$ Y-branch Ti:LiNbO$_3$ Mach-Zehnder Inteferometric Optical Waveguide for fabricating an Optical Phase Modulator)

  • 김성구;정운조;조재철;박계춘;이진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.101-104
    • /
    • 1998
  • We report some methods for measuring a LiNbO$_3$ optical phase modulator bandwidth. Since Mach-Zehnder waveguide type, one of methods for modulation bandwidth measurement, is comparatively simple and useful, it was adapted in this work. In order to confirm this method, the waveguide of single and Mach-Zehnder type were fabricated on the same wafer. The Mach-Zehnder interferometric waveguide and the single channel waveguide were used for the measurement of the phase modulator's driving voltage and bandwidth for device fabrications, respectively. Ti-860$\AA$ in-diffusion was achieved in a wet-bubbling oxygen environment at 105$0^{\circ}C$/8hours. LINbO$_3$ internal chips were pigtailed to PMF(polarization maintaining fiber)/SMF(single mode fiber) using an epoxy curing technique. Examined were optical properties such as an insertion loss, propagation loss and mode size, and the loss mechanism of optical coupling between an optical fiber and a waveguide was considered.

  • PDF

절삭 및 적층 가공법으로 제작한 임시 보철물 레진 블록과 재이 장용 자가중합 레진의 전단결합강도 비교 (Comparison of shear bond strength between various temporary prostheses resin blocks fabricated by subtractive and additive manufacturing methods bonded to self-curing reline resin)

  • 류효민;이진한
    • 대한치과보철학회지
    • /
    • 제61권3호
    • /
    • pp.189-197
    • /
    • 2023
  • 목적. 절삭 및 적층 가공 방식으로 제작한 임시 보철물 레진 블록과 재이장용 자가중합레진의 전단결합강도를 비교 평가하고자 하였다. 재료 및 방법. 레진 블록 시편의 제작방식에 따라 4개의 군으로 나누었고 subtractive manufacturing (SM), additive manufacturing stereolithography apparatus (AMS), additive manufacturing digital light processing (AMD), conventional self-curing (CON)의 방식으로 각 20개씩 레진 시편을 제작하였다. 제작 방식에 따른 레진 블록 시편과 재이장용 자가중합레진의 결합을 위해 시편의 표면에 실리콘 몰드를 이용하여 동일한 위치에 재이장 레진을 주입하여 중합하였다. 만능재료시험기를 이용하여 전단결합강도를 측정하였고 주사전자현미경으로 접착 계면의 파절 양상을 확인하였다. 실험군 간 비교를 위해 일원배치 분산분석과 사후 검정으로 Tukey test를 실시하였다(α = .05). 결과. 전단결합강도는 CON, SM, AMS, AMD군 순으로 높았다. CON군은 AMS군, AMD군과 유의한 차이가 있었고(P < .01) SM군과 유의한 차이가 없었다(P > .05). SM군은 AMD군과 유의한 차이가 있었고(P < .01) AMS군과 유의한 차이가 없었다(P > .05). AMS군은 AMD군과 유의한 차이가 있었다(P < .001). 파절 양상은 CON군, AMS군에서 혼합 파절이 높은 빈도로 나타났으며 SM군, AMD군에서 접착 파절이 높은 빈도로 나타났다. 결론. 절삭 및 적층 가공 방식으로 제작한 임시 보철물 레진 블록과 재이장용 자가중합 레진과의 전단결합강도에서 절삭 가공 방식(SM군)은 CON군보다 낮은 결합강도를 보였지만 유의한 차이를 보이지 않았다. 적층 가공 방식(AMS군, AMD군)은 CON군보다 유의하게 낮은 결합강도를 보였으며, AMD군이 가장 낮은 결합강도를 보였고 AMD군은 SM군과도 유의한 차이를 보였다.

광중합 기전에 따른 복합레진 중합 시 치수강 내 온도변화 (THE TEMPERATURE RISING IN PULP CHAMBER DURING COMPOSITE RESIN POLYMERIZATION)

  • 황동환;이주현;박호원
    • 대한소아치과학회지
    • /
    • 제30권3호
    • /
    • pp.431-438
    • /
    • 2003
  • 수복 치료과정에서 발생하는 온도증가가 치수조직에 미칠 수 있는 위해효과는 치의학의 오랜 관심사였다. 일반적으로, $5.5^{\circ}C$를 초과하는 치수 내 온도변화는 치수조직 에 비가역적인 손상을 야기할 수 있다. 기존의 할로겐 램프 광중합기와 더불어 최근 시판되고 있는 플라즈마 아크 중합기, LED 중합기를 사용하여 복합레진 중합시 치수강 내 온도증가량을 조사하였다. 한 개의 우식이 없는 치아를 대상으로 V급 와동을 형성하였다. 와동 내에 복합레진(Z250, Shade A2)을 충전한 후, 광중합조건을 달리하여 5군(I군: VIP, 20초 (mode 3), II군: VIP, 20초 (mode 6), III군: Flipo, 3초, IV군: Flipo, 5초 (2-step), V군: Lux-O-Max, 40초)으로 분류하고, 각 조건에 맞게 복합레진을 중합시키면서 치수강 내의 온도측정 단자를 통하여 $37.0^{\circ}C$로부터 증가되는 치수강 내 최대 온도증가량을 측정한 결과 다음과 같은 결론을 얻게 되었다. 1. 모든 군에서 치수강 내 최대 온도 증가량은 치수의 변성을 일으키기 시작하는 경계온도인 $5.5^{\circ}C$ 보다 낮았으며, II군에서 치수강 내 최대 온도증가량이 통계적으로 유의하게 가장 높았다(p<0.05). 또한 Lux-O-Max를 조사한 V군은 다른 군보다 낮은 치수강 내 최대 온도증가량을 나타내었다(p<0.05). 2. VIP로 조사한 두 군을 비교할 경우, 조사강도가 높은 II군이 I군보다 치수강 내 최대 온도증가량이 더 높게 증가하였으며(p<0.05), Flipo로 조사한 III군과 IV군 사이에서는 2-step 조사모드로 5초간 조사한 IV군이 3초간 조사한 III군보다 치수강 내 최대 온도증가량이 더 높게 증가하였다(p<0.05). 3. VIP와 Flipo를 비교할 경우, II군이 III, IV군보다 더 높게 증가하였고, IV군이 I군보다 더 높게 증가하였으나(p<0.05), I군과 III군 사이에는 차이를 보이지 않았다.

  • PDF

복합재 보강패널의 분리파손 및 좌굴 후 강도 특성 (Debonding and Postbuckling Failure Characteristics of Composite Stiffened Panels)

  • 김광수;유재석;안재모;장영순;이영무
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 춘계학술발표대회 논문집
    • /
    • pp.59-63
    • /
    • 2005
  • Compression tests were performed for six types of hat stiffened composite panels with different bonding methods and stiffener section shapes. Six panels showed similar behaviors in buckling and post-buckling region before a skin-stiffener separation failure occurred. The skin-stiffener separation failures occurred in the panels with closed type stiffeners regardless of bonding methods, but not in the panels with open type stiffeners. The separation failures not only reduced the postbuckling strength but also changed buckling mode and postbuckling stiffness. All the separation failures were initiated at the stiffener flange edges closest to skin buckling crests. The co-cured or secondary bonded panels with open type stiffeners had the largest structural performance. Because the post-buckling strength and performance of the composite stiffened panels are reduced by the separation failure, it is important to find bonding methods, stiffener types and manufacturing parameters for preventing of the separation failure.

  • PDF

유연기판을 위한 UV/Thermal 하이브리드방식 나노임프린트 시스템 (UV/Thermal Hybrid Nanoimprint System for Flexible Substrates)

  • 임형준;이재종;최기봉;김기홍;안현진;류지형
    • 한국생산제조학회지
    • /
    • 제20권3호
    • /
    • pp.245-250
    • /
    • 2011
  • An UV/thermal hybrid nanoimprint lithography system was designed and implemented for the pattern transfer to flexible substrates. This system can utilize a plate stamp, roll stamp, and film stamp. For all cases of using those stamps, this system is also switchable an UV or thermal nanoimprint lithography mode. This paper shows how to design the heating and UV curing plates and proposes how to change them easily. Because the pressure condition and the speed of the press roller varies by the characteristics of the stamp and substrate, all the parameters related to the nanoimprint lithography have to adjustable. Some transferred patterns are shown in this paper to verify the performance of the hybrid nanoimprint lithography system. The flexible substrates with nano-scale patterns on them will be key components for next generation technologies such as flexible displays, bendable semi-conductors, and solar cells.

레진치와 의치상 레진간의 전단 결합강도에 관한 연구 (THE SHEAR BOND STRENGTH OF RESIN TEETH TO THE DENTURE BASE RESIN)

  • 송영국;정영완;진태호
    • 대한치과보철학회지
    • /
    • 제37권2호
    • /
    • pp.235-241
    • /
    • 1999
  • The bond failure of resin teeth In denture base resin is one of the failure in prosthodontic treatment. The purpose of this study was to evaluate the bond strength of artificial resin teeth to the denture base resins. Specimens were made with heat curing acrylic resins (Vertex Rs, Lucitone 199) and artificial resin teeth (Tiger, Trubyte biotone, Endura, Orthosit, Tubyte bioform IPN) and the bond strength were measured with testing machine(Zwick. Germany) and the mode of bond failure were observed. The results were as follows; 1. The bond strength of Vertex Rs to artificial resin teeth was the highest in Tubyte biotone, and It was the lowest in Tiger and Trubyte bioform IPN. 2. The bond strength of Lucitone 199 to artificial resin teeth were higher in Orthosit and Trubyte bioform IPN than in Tiger and Trubyte biotone. 3. The bond strength of Trubyte biotone to Vertex Rs was higher than to Lucitone 199 and that of the Trubyte bioform IPN to Lucitone 199 was higher than to Vertex Rs. 4. Nearly all bond failures of specimens occured cohesively within the resin teeth.

  • PDF

Characterization and Purification of Acidocin 1B, a Bacteriocin Produced by Lactobacillus acidophilus GP1B

  • Han, Kyoung-Sik;Kim, Young-Hoon;Kim, Sae-Hun;Oh, Se-Jong
    • Journal of Microbiology and Biotechnology
    • /
    • 제17권5호
    • /
    • pp.774-783
    • /
    • 2007
  • In the present study, acidocin 1B, a bacteriocin produced by Lactobacillus acidophilus GP 1B, exhibited profound inhibitory activity against a variety of LAB and pathogens, including Gram-negative bacteria, and its mode of action was to destabilize the cell wall, thereby resulting in bactericidal lysis. Acidocin 1B was found to be heat stable, because it lost no activity when it was heated up to $95^{\circ}C$ for 60 min. It retained approximately 67% of the initial activity after storage for 30 days at $4^{\circ}C$, and 50% of its initial activity after 30 days at $25^{\circ}C$ and $37^{\circ}C$. The molecular mass of acidocin 1B was estimated to be 4,214.65 Da by mass spectrometry. Plasmid curing results indicated that a plasmid, designated as pLA1B, seemed to be responsible for both acidocin 1B production and host immunity, and that the pLA1B could be transformed into competent cells of L. acidophilus ATCC 43121 by electroporation. Our findings indicate that the acidocin 1B and its producer strain may have potential value as a biopreservative in food systems.

광조사 방식이 복합레진 수복물의 변연누출에 미치는 영향 (EFFECT OF LIGHT IRRADIATION MODES ON THE MARGINAL LEAKAGE OF COMPOSITE RESIN RESTORATION)

  • 박은숙;김기옥;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제26권4호
    • /
    • pp.263-272
    • /
    • 2001
  • 저광도 중합법, 펄스 지연 중합법, 초고광도 중합법 등의 광조사 방식이 광중합형 복합레진 수복물에서의 중합수축 응력에 미치는 영향을 알아보기 위해 in vitro에서 미세 누출 실험을 하였다. 80개의 발거된 소구치의 협측면에 5급 와동을 형성하고, 600mW/$cm^2$로 30초간 광조사하는 보통 광도 중합군, 300mW/$cm^2$로 60초간 광조사하는 저광도 중합군, 400mW/$cm^2$로 2초간 광조사하고 5분간 기다린 후 800mW/$cm^2$로 10초간 최종 중합시키는 펄스-지연 중합군, 그리고 1930mW/$cm^2$의 광도로 3초간 광조사하는 초고광도 중합군 등의 4개의 군으로 나누어 hybrid 형의 광중합복합레진을 충전하고 각 군의 방법대로 중합한 후, 변연의 0.5mm 외부에 nail varnish를 도포하고 37$^{\circ}C$, 2% metylene blue 용액에 24시간 동안 침적시켰다. 시편을 아크릴릭 레진에 매몰한 후 수복물의 중앙에서 종절단하여 입체현미경하에서 그 단면을 관찰한 후 법랑질과 상아질 변연으로 나누어 색소의 침투도를 측정하여 다음과 같은 결과를 얻었다. 1. 펄스 지연 중합군의 색소 침투도는 법랑질과 상아질 변연 모두에서 보통광도, 저광도 및 초고광도 중합군과 유의한 차이를 보이지 않았다(p>0.05). 2. 상아질 변연에서 초고광도 중합군은 보통광도 중합군과 저광도 중합군에 비해 유의하게 높은 색소 침투도를 보였다(p<0.05). 3. 법랑질 변연에서의 4개 군의 색소 침투도는 서로 유의한 차이를 보이지 않았다(p>0.05). 4. 모든 군에서 상아질 변연에서의 색소 침투도는 법랑질군에서의 색소 침투도에 비해 유의하게 높았다(p<0.05).

  • PDF