• Title/Summary/Keyword: Cumulative histogram

Search Result 59, Processing Time 0.033 seconds

Efficient Video Retrieval Scheme with Luminance Projection Model (휘도투시모델을 적용한 효율적인 비디오 검색기법)

  • Kim, Sang Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8649-8653
    • /
    • 2015
  • A number of video indexing and retrieval algorithms have been proposed to manage large video databases efficiently. The video similarity measure is one of most important technical factor for video content management system. In this paper, we propose the luminance characteristics model to measure the video similarity efficiently. Most algorithms for video indexing have been commonly used histograms, edges, or motion features, whereas in this paper, the proposed algorithm is employed an efficient similarity measure using the luminance projection. To index the video sequences effectively and to reduce the computational complexity, we calculate video similarity using the key frames extracted by the cumulative measure, and compare the set of key frames using the modified Hausdorff distance. Experimental results show that the proposed luminance projection model yields the remarkable improved accuracy and performance than the conventional algorithm such as the histogram comparison method, with the low computational complexity.

Probability Density Function of the Tidal Residuals in the Korean Coast (한반도 연안 조위편차의 확률밀도함수)

  • Cho, Hong-Yeon;Kang, Ju-Whan
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.24 no.1
    • /
    • pp.1-9
    • /
    • 2012
  • Tidal residual is being an important factor by the influence of the climate change in terms of the coastal safety and defense. It is one of the most important factor for the determination of the reference sea level in order to check the safety and performance of the coastal structures in company with the typhoon intensity variation. The probability density function (pdf) of tidal residuals in the Korean coasts have a non-ignorable skewness and high kurtosis. It is highly restricted to the application of the normal pdf assumption as an approximated pdf of tidal residuals. In this study, the pdf of tidal residuals estimated using the Kernel function is suggested as a more reliable and accurate pdf of tidal residuals than the normal function. This suggested pdf shows a good agreement with the empirical cumulative distribution function and histogram. It also gives the more accurate estimation result on the extreme values in comparison with the results based on the normal pdf assumption.

A Design of Economic CUSUM Control Chart Incorporating Quality Loss Function (품질손실을 고려한 경제적 CUSUM 관리도)

  • Kim, Jungdae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.4
    • /
    • pp.203-212
    • /
    • 2018
  • Quality requirements of manufactured products or parts are given in the form of specification limits on the quality characteristics of individual units. If a product is to meet the customer's fitness for use criteria, it should be produced by a process which is stable or repeatable. In other words, it must be capable of operating with little variability around the target value or nominal value of the product's quality characteristic. In order to maintain and improve product quality, we need to apply statistical process control techniques such as histogram, check sheet, Pareto chart, cause and effect diagram, or control charts. Among those techniques, the most important one is control charting. The cumulative sum (CUSUM) control charts have been used in statistical process control (SPC) in industries for monitoring process shifts and supporting online measurement. The objective of this research is to apply Taguchi's quality loss function concept to cost based CUSUM control chart design. In this study, a modified quality loss function was developed to reflect quality loss situation where general quadratic loss curve is not appropriate. This research also provided a methodology for the design of CUSUM charts using Taguchi quality loss function concept based on the minimum cost per hour criterion. The new model differs from previous models in that the model assumes that quality loss is incurred even in the incontrol period. This model was compared with other cost based CUSUM models by Wu and Goel, According to numerical sensitivity analysis, the proposed model results in longer average run length in in-control period compared to the other two models.

Verification of Clinical Usefulness of Jaw Tracking in IMRT (IMRT에 있어 Jaw Tracking 의 임상적 유용성 검증)

  • Kim, Jin-young;Kim, Ki-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.105-109
    • /
    • 2020
  • Intensity-modulated radiotherapy(IMRT) has disadvantages such as increasing the low doses of irradiation to normal tissues and accumulated dose for the whole volume by leakage and transmission of the Multi Leaf Collimator (MLC). The accumulated dose and low dose may increase the occurrence of secondary malignant neoplasms. For this reasons, the jaw tracking function of the TrueBeam (Varian Medical Systems, Palo Alto, CA) was developed to reduce the leakage and transmission dose of the MLC with existing linear accelerators. But quantitative analysis of the dose reduction has not been verified. Therefore, in the present study, we intended to verify the clinical possibility of utilizing the jaw tracking function in brain tumor with comparison of treatment plans. To accomplish this, 3 types of original treatment plans were made using Eclipse11 (Varian Medical Systems, Palo Alto, CA): 1) beyond 2 cm distance from the Organs At Risk (OARs); 2) within 2 cm distance from the OARs; and 3) intersecting with the OARs. Jaw tracking treatment plans were also made with copies of the original treatment planning using Smart LMC Version 11.0.31 (Varian Medical Systems, Palo Alto, CA). A comparison between the 2 types of treatment planning methods was performed using the difference of the mean dose and maximum dose to the OARs in cumulative Dose Volume Histogram (DVH). In the DVH comparison, the maximum difference of 0.5 % was observed between the planning methods in the case of over 2 cm distance, and the maximum of 0.6 % was obtained for within the 2 cm distance. For the case intersecting with the OAR, the maximum difference of 2 % was achieved. According to these results, it could be realized that the differences of mean dose and maximum dose to the OARs was larger when the OARs and PTV were closer. Therefore, treatment plans with the jaw tracking function consistently affected the dose reduction and the clinical possibility could be verified.

The Comparison of DVH between Multiple arc FSRT and Conformal FSRT (Multiple arc FSRT와 Conformal FSRT의 DVH 비교)

  • Kim Ki-Hwan;Kim Jun-Sang;Jang JiYoung;Kim Jae-Sung;Kim Seong-Ho;Song Chang-Joon;Park Min-Kyu;Cho Moon-June
    • Radiation Oncology Journal
    • /
    • v.17 no.3
    • /
    • pp.261-267
    • /
    • 1999
  • Purpose : In FSRT (Fractionated stereotactic radiotherapy) planning, we studied the usefulness between multiple arc FSRT and conformal FSRT by comparing tumor shape and DVH (dose volume histogram). Materials and Methods In Chungnam Univ. hospital, we had treated the sixteen patients with FSRT from Aug. 1997 to Dec. 1998. In choosing multiple arc FSRT or conformal FSRT, we had considered If (irregular factor) after calculating tumor volume and surface area. We had considered multiple arc FSRT if tumor shape was similar to sphere or the value of If was less than 1.25, conformal FSRT if tumor shape was very irregular or If was more than 1.3. For evaluation of treatment planning, we had considered the appropriate DVH for tumor volume and for critical organs. Results : The errors between reference point and the coordinates point on AP, Lat radiography were less than 1 mm before treatment. We had planned $3\~$5 arcs for multiple arc FSRT, $5\~6$ports for conformal FSRT. The mean dose distribution of tumor volume of cumulative DVH between multiple arc FSRT and conformal FSRT was 90.6, 85%, respectively. The dose of critical organs irradiated was less than $5\%$ maximum dose of cumulative DVH. Conclusion : We had obtained the similar value between multiple arc FSRT and conformal FSRT, so that we had appropriate treatment planning of FSRT for multiple arc FSRT and conformal FSRT according to tumor shape and size.

  • PDF

Development of a Korean Sexual Satisfaction Scale (한국 성인의 성만족 측정도구 개발)

  • Lee Byung-Sook;Koh Hyo-Jung;Kim Myung-Ae;Im Shin-Hwa
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.9 no.2
    • /
    • pp.190-200
    • /
    • 2002
  • Purpose; The purpose of this study was to develop an instrument to measure sexual satisfaction in Korean adults. Method: Development of items for the instrument was done by a collecting, reorganizing, reducing and selecting process based on the literature. A total of 19 items were selected in this process. For evaluation of the appropriateness of the 19 items, questionnaires were given to an expert group consisting of 18 professionals (7 men and 11 women). Eighteen items having a response of 70% in 'very good' item or 'good' item were included as items for the instrument. With these 18 items, a 5 point Likert scale was developed, and reliability and validity tests of the scale were done. The subjects for the test were 1,127 Korean adults living in 11 areas in Korea, Data were collected from Dec. 1, 2000 to Feb. 28, 2001 and analyzed with SPSS/PC+ 10.0 program. Item analysis and factor analysis were used to assess the reliability and validity of the scale. Chronbach alpha and corrected item-total correlation were obtained to verify internal consistency, and principal component analysis with the varimax rotation was used to identify structure validity of the developed tool. Result: Reliability of the scale was .9503 and corrected item-total correlations of the items were distributed from .5208 to 7899. As a result of the factor analysis, the items were categorized into three factors. The cumulative variance of the three factors was 67.1%, and all of the variances of the factors were above 5%. Because factor 1 (8 items) indicated a special feeling of psychological satisfaction with sexual activity, it was named 'psychological factor'. Factor 2 (8 items) indicated a feeling of satisfaction in the interaction with sexual partner through communication and variation, therefore it was named 'interactional factor'. Factor 3 (2 items) was about the frequency and duration of sexual intercourse and indicated physical dimensions of satisfaction, so it was named 'physical factor'. The average score for sexual satisfaction of the 1,127 subjects was 65.32 (${\pm}12.71$), and histogram of the score showed a normal distribution with skewness - .425. Conclusion: Finally, a Korean Sexual Satisfaction Scale(KSSS) was accepted as a 5 point Likert scale with 18 items after the statistical test for reliability and validity. In conclusion, KSSS is a useful instrument which is valid and reliable can be used to understand the sexuality of Korean adults.

  • PDF

Dosimetric and clinical review on the application of TOMO_edge mode (토모테라피 Edge 모드를 이용한 임상적 유용성 고찰)

  • Kim, Lizzy
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.177-182
    • /
    • 2014
  • Purpose : The goal of this study was to compare and analysis the dose distribution and treatment time between Tomotherapy planning with fixed jaw(FJ) and dynamic jaw(DJ). Materials and Methods : Seven patients were selected in the study including five common clinical cases(brain, head and neck(HN), lung, prostate, spine). 1) Helical Tomotherapy plans with FJ and DJ were generated with the same planning parameters such as Modulation factor, Pitch and Field width. 2) Tomo_edge plans with a larger field width were generated to compare to conventional HT delivery with fixed jaw. Dosimetric evaluation indices for target coverage are Dmin, Conformity index(CI) and for whole body including target are $V_{10%}$, $V_{25%}$, $V_{50%}$, $V_{75%}$ using Dose-volume histogram(DVH). Also, Treatment time and Cumulative MU were used for clinical review on Tomo_edge. Results : In case of using the same field width of Tomotherapy planning with FJ and DJ, the averaged variations were $V_{10%}$: -11.91%, $V_{25%}$: -7.6%, $V_{50%}$ :-4.75%, $V_{75%}$: -1.04%. Tomo_edge with a larger field width provides the averaged variations for target coverage: Dmin: -0.72%, CI: -1.25% and also shows the tendency of a sharp $V_{x%}$ decline in low dose area. The clinical improvements in the larger field width with DJ were observed in the treatment time, ranging from -51.21% to -15.11, and the Cumulative MU decrease, ranging from -57.74% to -15.31%. Conclusion : Target coverage achieved by FJ and DJ with the same field width has little differences. But integral doses on whole body efficiently decreased. Compared to the conventional HT delivery, Tomo_edge with a larger field width presents a little worse target coverage. However, it provides faster treatment delivery and improved cranial-caudal target dose conformity. Therefore, Tomo_edge mode is efficient in improving the treatment time and integral dose while maintaining comparable plan quality in clinic.

Clinical Application of Dose Reconstruction Based on Full-Scope Monte Carlo Calculations: Composite Dose Reconstruction on a Deformed Phantom (몬테칼로 계산을 통한 흡수선량 재구성의 임상적 응용: 변형된 팬텀에서의 총제적 선량재구성)

  • Yeo, Inhwan;Xu, Qianyi;Chen, Yan;Jung, Jae Won;Kim, Jong Oh
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.139-142
    • /
    • 2014
  • The purpose of this study was to develop a system of clinical application of reconstructed dose that includes dose reconstruction, reconstructed dose registration between fractions of treatment, and dose-volume-histogram generation and to demonstrate the system on a deformable prostate phantom. To achieve this purpose, a deformable prostate phantom was embedded into a 20 cm-deep and 40 cm-wide water phantom. The phantom was CT scanned and the anatomical models of prostate, seminal vesicles, and rectum were contoured. A coplanar 4-field intensity modulated radiation therapy (IMRT) plan was used for this study. Organ deformation was simulated by inserting a "transrectal" balloon containing 20 ml of water. A new CT scan was obtained and the deformed structures were contoured. Dose responses in phantoms and electronic portal imaging device (EPID) were calculated by using the XVMC Monte Carlo code. The IMRT plan was delivered to the two phantoms and integrated EPID images were respectively acquired. Dose reconstruction was performed on these images using the calculated responses. The deformed phantom was registered to the original phantom using an in-house developed software based on the Demons algorithm. The transfer matrix for each voxel was obtained and used to correlate the two sets of the reconstructed dose to generate a cumulative reconstructed dose on the original phantom. Forwardly calculated planning dose in the original phantom was compared to the cumulative reconstructed dose from EPID in the original phantom. The prescribed 200 cGy isodose lines showed little difference with respect to the "prostate" and "seminal vesicles", but appreciable difference (3%) was observed at the dose level greater than 210 cGy. In the rectum, the reconstructed dose showed lower volume coverage by a few percent than the plan dose in the dose range of 150 to 200 cGy. Through this study, the system of clinical application of reconstructed dose was successfully developed and demonstrated. The organ deformation simulated in this study resulted in small but observable dose changes in the target and critical structure.

Comparison of Anisotropic Analytic Algorithm Plan and Acuros XB Plan for Lung Stereotactic Ablative Radiotherapy Using Flattening Filter-Free Beams (비편평화여과기 빔을 이용한 폐 정위절제방사선치료를 위한 AAA와 Acuros XB 계산 알고리즘의 치료계획 비교)

  • Chung, Jin-Beom;Eom, Keun-Yong;Kim, In-Ah;Kim, Jae-Sung;Lee, Jeong-Woo;Hong, Semie;Kim, Yon-Lae;Park, Byung-Moon;Kang, Sang-Won;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.210-217
    • /
    • 2014
  • This study investigated the dosimetric effects of different dose calculation algorithm for lung stereotactic ablative radiotherapy (SABR) using flattening filter-free (FFF) beams. A total of 10 patients with lung cancer who were treated with SABR were evaluated. All treatment plans were created using an Acuros XB (AXB) of an Eclipse treatment planning system. An additional plans for comparison of different alagorithm recalcuated with anisotropic analytic algorithm (AAA) algorithm. To address both algorithms, the cumulative dose-volume histogram (DVH) was analyzed for the planning target volume (PTV) and organs at risk (OARs). Technical parameters, such as the computation times and total monitor units (MUs), were also evaluated. A comparison analysis of DVHs from these plans revealed the PTV for AXB estimated a higher maximum dose (5.2%) and lower minimum dose (4.2%) than that of the AAA. The highest dose difference observed 7.06% for the PTV $V_{105%}$. The maximum dose to the lung was also slightly larger in the AXB plans. The percentate volumes of the ipsilateral lung ($V_5$, $V_{10}$, $V_{20}$) receiving 5, 10, and 20 Gy were also larger in AXB plans than for AAA plans. However, these parameters were comparable between both AAA and AXB plans for the contralateral lung. The differences of the maximum dose for the spinal cord and heart were also small. The computation time of AXB plans was 13.7% shorter than that of AAA plans. The average MUs were 3.47% larger for AXB plans than for AAA plans. The results of this study suggest that AXB algorithm can provide advantages such as accurate dose calculations and reduced computation time in lung SABR plan using FFF beams, especially for volumetric modulated arc therapy technique.