• Title/Summary/Keyword: Cumulative heat

Search Result 73, Processing Time 0.024 seconds

A Study on the Harmonic Characteristics of GHP Cooling/Heating Load in an Institutional Building (교육용 건물의 GHP 냉/난방 부하의 고조파 특성에 관한 연구)

  • Kim, Kyung-Chul;Oh, Kyung-Hoon;Lee, Kyu-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.4
    • /
    • pp.29-38
    • /
    • 2009
  • The GHP(Gas Heat Pump) is an efficient cooling;11eating system in which a compressor is driven by a gas engine and is brodening its application to the facilities such as schools and office buildings. It is difficult to control the GHP system because of slow response, big time constant and time variant system. These nonlinear loads generate harmonic currents and create distortions on the sinusoidal voltage of the power system Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. A cumulative probability approach is the most commonly used method to solve time varying harmonics. This paper provides an in depth analysis on harmonics field measurement of the GHP loads, harmonic assessment by me 61000-3-2, and harmonic simulation and harmonic filter application using EDSA program for the case study system.

Effects of Lonicerae Caulis (LC) on Allergic Contact Dermatitis (ACD) induced by DNCB in mice (인동등(忍冬藤)이 DNCB로 유발된 알레르기성 접촉피부염에 미치는 영향)

  • Lee, Yu-Jin;Lee, Ho-Chan;Choi, Jung-Hwa;Kim, Jong-Han;Park, Soo-Yeon
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.30 no.3
    • /
    • pp.46-61
    • /
    • 2017
  • Objectives : Allergic contact dermatitis(ACD) is a type IV delayed hypersensitivity reaction that results from cumulative exposures and subsequent sensitization to an environmental chemical. Lonicerae Caulis(LC) can clear away heat and relieve toxin, disperse wind and heat, dredge the channel. The present study was designed to investigate the effects of LC on allergic contact dermatitis(ACD) induced by 2,4-dinitrochlorobenzene(DNCB) in mice. Methods : In this experiment, the effects of LC on changes in body weights, ear and dorsum skin thicknesses, ear weights, clinical aspects on the dorsum skin, histopathological changes, spleen/body ratio, cytokines were investigated. In addition, the effects on proliferations of splenocytes were also investigated in vitro and vivo study. Results : LC spread(SPR) group and LC spread and administered(SPR+ADM) group showed diminished ear thicknesses. In SPR+ADM group, ear weights were lowered significantly compared to contact dermatitis control(CTL) group. LC treatment diminished erythema, desquamation and keratosis which were induced by repeated painting of DNCB. In histopathological observation, spongiosis and edema were diminished in SPR and SPR+ADM group. In cytokines, SPR+ADM group were increased in IL-10, and SPR and SPR+ADM group were decreased in TNF-${\alpha}$ compared with control group. Conclusions : These data suggest that LC can decrease symptoms of ACD, then LC is useful to treat patient with ACD.

Integrated Digestion of Thermal Solubilized Sewage Sludge to Improve Anaerobic Digestion Efficiency of Organic Waste (유기성 폐기물의 혐기성 소화효율 향상을 위한 열가용화 하수슬러지의 통합소화)

  • Oh, Kyung Su;Hwang, Jung Ki;Song, Young Ju;Kim, Min Ji;Park, Jun Gyu;Pak, Dae Won
    • Journal of Korean Society on Water Environment
    • /
    • v.38 no.2
    • /
    • pp.95-102
    • /
    • 2022
  • Studies for improving the efficiency of the traditional anaerobic digestion process are being actively conducted. To improve anaerobic digestion efficiency, this study tried to derive the optimal pretreatment conditions and mixing conditions by integrating the heat solubilization pretreatment of sewage sludge, livestock manure, and food waste. The soluble chemical oxygen demand (SCOD) increase rate of sewage sludge before and after heat solubilization pretreatment showed an increased rate of 224.7% compared to the control group at 170℃ and 25 min and showed the most stable increase rate. As a result of the biomethane potential test of sewage sludge before and after heat solubilization pretreatment, the total chemical oxygen demand (TCOD) and SCOD removal rates increased as the heat solubilization temperature increased, but did not increase further at temperatures above 170℃. In the case of methane generation, there was no significant change in the cumulative methane generation from 0.134 to 0.203 Sm3-CH4/kg-COD at 170℃ for 15 min. As a result of the integrated digestion of organic waste, the experimental condition in which 25% of the sewage sludge, 50% of the food waste, and 25% of the livestock manure were mixed showed the highest methane production of 0.3015 m3-CH4/kg-COD, confirming that it was the optimal mixing ratio condition. In addition, under experimental conditions mixed with all three substrates, M4 conditions mixed with 25% sewage sludge, 50% food waste, and 25% livestock manure showed the highest methane generation at 0.2692 Sm3-CH4/kg-COD.

Numerical Simulation of Standing Column Well Ground Heat Pump System Part II: Parametric Study for Evaluation of the Performance of Standing Column Well (단일심정 지열히트펌프의 수치적 모델링 Part II: 단일심정 지열히트펌프의 성능평가를 위한 매개변수 연구)

  • Park, Du-Hee;Kim, Kwang-Kyun;Kwak, Dong-Yeop;Chang, Jae-Hoon;Na, Sang-Min
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.2
    • /
    • pp.45-54
    • /
    • 2010
  • The SCW numerical model described in the companion paper was used to carry out a comprehensive parametric study to evaluate the performance of the SCW. The five ground related parameters, which are porosity, hydraulic conductivity, thermal conductivity, specific heat, geothermal gradient, and five SCW design parameters, which are pumping rate, well depth, well diameter, dip tube diameter, bleeding rate, were used in the study. Two types of numerical simulations were performed. The first type was used to perform short-term (24-hour) simulation, while the second type 14 day simulation. The study results indicate that the parameters that have important influence on the performance of SCW were hydraulic conductivity, thermal conductivity, geothermal gradient, pumping rate, and bleeding rate. The thermal conductivity had the most important influence on the performance of the SCW. With the increase in the geothermal gradient, the performance increased in the heat mode, but decreased in the cooling mode. The hydraulic conductivity influenced the performance when the value was larger than $10^{-4}m/s$. The depth of the well increased the performance, but at the cost of increased cost of boring. The bleeding had an important influence on SCW, greatly enhancing the performance at a limited increased cost of operation. Overall, this study showed that various factors had a cumulative influence on the performance of the SCW, and a numerical simulation can be used to accurately predict the performance of the SCW.

Plastic and Drying Shrinkage Cracking Reduction by the Bubble Sheet Curing (버블시트 피복양생법에 의한 소성 및 건조수축 균열저감)

  • Lee, Joung-Gyo;Han, Cheon-Goo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.3
    • /
    • pp.211-217
    • /
    • 2016
  • In this research, the performance of surface covering technique using a white-colored bubble sheet on reducing the cracking due to the plastic, and drying shrinkages for high rise building construction were evaluated by comparing the exposed surface without any surface treatment. From the results of the experiment conducted during fall season, desired results of decreased numbers, length, maximum width, and area of cracking were obtained without a significant difference on heat of hydration and cumulative temperature. Therefore, it is considered that the surface covering technique using bubble sheet is an appropriate method for preventing plastic and drying shrinkage cracking at fall season concrete construction.

Fatigue Life Evaluation and Optimization for District Heating Pipes Considering Operating Temperature Transition Data (운전이력을 고려한 지역난방 열배관의 피로수명 평가 및 최적화)

  • Ahn M.Y.;Jung S.W.;Lee S.M.;Chang Y.S.;Choi J.B.;Kim Y.J.;Kim S.H.;Kim Y.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.581-584
    • /
    • 2005
  • A district heating(DH) system supplies environmentally-friend heat and is appropriate for reduction of energy consumption and/or air pollutions. The objectives of this paper are to systematize data processing of transition temperature, investigate its effects on fatigue life of DH pipes and optimization for size of DH pipes. A relational database management system as well as reliable fatigue life evaluation procedures is established for Korean DH pipes. Also, since the prototypal evaluation results satisfied both cycle-based and stress-based fatigue criteria. Through the optimum design process, the cross section diminished 18.64% and the CUF diminished 23.35%. So, it can be used as useful information in the future for optimal design, operation and energy saving via setting of efficient condition and stabilization of water temperature.

  • PDF

Evaluation of High Cycle Thermal Fatigue on Mixing Tee in Nuclear Power Plant (원전 Mixing Tee에서의 고주기 열피로 평가)

  • Lee, Sun Ki
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.16 no.1
    • /
    • pp.22-29
    • /
    • 2020
  • In nuclear power plants, there is a risk of thermal fatigue in equipment and piping affecting system soundness because the temperature change of the system accompanies in every operation and shutdown. Therefore, in order to prevent the excess of the fatigue limit during the lifetime of plants, the fatigue limit of each piping material is determined in the designing stage. However, there are many cases where equipment or piping is locally subjected to thermal fatigue that is not considered in the design, resulting in damage to the equipment and piping, and failure during operation. Currently, local thermal fatigue generation mechanisms that are not taken into account in the design stage are gradually being identified. In this paper, the effects of the fluid temperature fluctuations on the piping soundness due to the mixing of hot and cold water, one of the local thermal fatigue generating mechanisms, were evaluated.

ACOUSTIC EMISSION BEHAVIOR DURING STRESS CORROSION CRACKING OF INCONEL 600

  • Sung, Key-Yong;Cho, Sang-Jin;Kim, Bong-Hyun;Kim, In-Sup
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05c
    • /
    • pp.145-150
    • /
    • 1996
  • Acoustic Emission (AE) technique was applied to stress corrosion cracking of Inconel 600 to investigate the AE capability of detecting crack growth and to obtain the relation between AE characteristics and crack mechanism. The specimens were heat-treated in two conditions (600$^{\circ}C$ for 30 hrs or 700 $^{\circ}C$ for 1 hr) and undergone CERT at two extension rates ( 2.5${\times}$10$^{-5}$ or 1.25${\times}$10$^{-4}$(mm/s)). It was found that the AE peak amplitude from plastic deformation was generally smaller than about 48dB (0.25mV), while Intergranular stress corrosion cracking (IGSCC) and ductile fracture produced higher values of 49 to 70dB (0.3mV to 3mV). The slopes of cumulative amplitude distribution (b-values) were linearly dependent on IGSCC susceptibility and the higher the susceptibility, the smaller the b-value. The monitoring of combined AE parameters such as event rate, amplitude, count and energy can provide effective means to clearly identify the transition from crack initiation and small crack growth to rapid growth of dominant cracks.

  • PDF

Optimization of Bar-to-Bar Similar Friction Welding of Crank Shaft for Motor Vehicle and the Weld Fatigue Strength Properties and its AE Evaluation (자동차 크랭크 軸用 鋼材의 棒對棒 同種材 摩擦熔接의 疲勞强度 特性 및 AE 評價)

  • Oh, Sea-Kyoo;Yang, Hyung-Tae;Kim, Hun-Kyoung
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.2 s.32
    • /
    • pp.74-82
    • /
    • 1999
  • Nowadays, the crank shaft motor vehicle has become essential as the important component. The machining precision was asked for manufacturing the shaft. They could be unstable in the quality by the conventional are welding. Both in-process quailty control and high reliability of the weld are the major concerns in applying friction wlding to the economical and qualified mass-production. No reliable nondestructive monitoring method is avaliable at present to determine the real-time evaluation of automatic production quality control for bar-to-bar friction welding of the crank shaft of O.D 24mm for motor vehicle. This paper, so that, presents the experimental examinations and statistical quantitative analysis of the correlation between the cumulative counts of acoustic emission(AE) during plastic deformation periods of the welding and the tensile strength and other properties of the bar-to-bar welded joints of O.D. 24mm shaft as well as the various welding variables, as a new approach which attempts finally to develop real-time quality monitoring system for friction welding, resulting in practical possiblility of real-time quality control more than 100% joint efficiency showing good weld with no micro structural defects.

  • PDF

Development of the Heat-Resistant Functionally Gradient Material with Metal Substrate (금속기지 내열 경사기능 복합재료 개발에 관한 연구)

  • Kim, Bu-Ahn;Nam, Ki-Woo;Cho, Mun-Ho
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.1 s.31
    • /
    • pp.62-69
    • /
    • 1999
  • 67Ni-22Cr-10Al-1Y and $ZrO_2-8Y_2O_3$ were coated on the substrate surface of ST304 and Al2024 by the plasma spraying method. The adgesion of the films varies depending on the substrates and the laminating method. In the case of STS304, the cracks were observed at thermal shock temperature difference ${Delta}T$ of $900^{circ}C$ in the non functionally gradient material(NFGM) and at $1100^{circ}C$ in the functionally gradient material(FGM). The film adhesion of the FGM is better than that of the NFGM in ST304. The cumulative AE count of the FGM of STS304 increased continuously at the bending test. But the NFGM of STS304 showed discontinuity of the AE count. The total AE count for the FGM of STS304 decreased as the number of thermal shock increased, and this tendency was evident as the thermal shock temperature difference increased.

  • PDF