• Title/Summary/Keyword: Cu matrix

Search Result 443, Processing Time 0.025 seconds

Potentiometric Response of Chitin - based Membrane Electrode to various Metal cations (키틴 막 전극의 양이온에 대한 감응 연구)

  • Choi, Bun-Hong;Yun, Young-Ja
    • Analytical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.235-242
    • /
    • 1998
  • Membrane electrode based on chitin(po1y-[$1{\rightarrow}4$]-${\beta}$-N-acetyl-D-glucosamine) was prepared by mixing uniformly grounded of chitin (100 mesh) with PVC and DOS. We investigated the potential response of chitin membrane electrode to metal ions. It was observed that the response slopes for $Cd^{2+}$(34.9 mV/decade) and $Cu^{2+}$(34.0 mV/decade) were larger than those for other ions in pH 4 acetate buffer. The potentiometric response of chitin electrode to varying pH was nearly constant in the pH range of 2~12.

  • PDF

A Study on the Elimination of Fe Elements in Aluminum Alloy by Electromagnetic Force;Part 2. The Movement of Fe-Contained Intermetallics with Electromagnetic Force in Al-Si-Cu Scrap (전자기력을 이용한 알루미늄 스크랩 중의 Fe 제거에 관한 연구;Part 2. Al-Si-Cu계 합금 스크랩에서 전자기력에 따른 Fe계 금속간화합물의 이동양상)

  • Kim, Jeong-Ho;Noh, Jeong-Hoon;Park, Joon-Pyo;Yoon, Eui-Pak
    • Journal of Korea Foundry Society
    • /
    • v.18 no.3
    • /
    • pp.240-245
    • /
    • 1998
  • In the view point of the environmental conservation and the energy reduction, the recycling of metal scrap is coming as one of the global subjects in the world. In this study, the movement of intermetallics with electromagnetic force in a melt of a scrap of Al-Si-Cu alloy (JIS ADC12), which was widely used in diecasting process, was investigated in order to eliminate the Fe element, which was usually accumulated in a scrap. In this study, we applied electromagnetic method to eliminate Fe element in ADC12 aluminum alloy scrap which contains 1.64wt.% Fe and the effects of electromagnetic force on the particle movement was visualized and confirmed by water modeling and experiment. As a result, the Fe intermetallic compounds are moved to the direction opposite to that of the electromagnetic force as the force applies, thus eliminated from the bulk metal. Therefore, the content of Fe in matrix decreased from 1.64wt.% to 0.45wt.%.

  • PDF

Formation of the precipitates in the Bi-2223/Ag superconducting tapes by post-heat treatment (Bi-2223 초전도 선재의 후열처리 과정에 의한 석출물의 형성)

  • Lee, Sang-Hee;Kim, Cheol-Jin;Chung, Jun-Ki;Yoo, Jae-Moo;Ko, Jae-Woong
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.262-267
    • /
    • 2000
  • To tap the possibility of exploiting the precipitates as flux-pinning center in the Bi-2223 superconducting system, as-received Bi-2223/Ag tapes with the starting composition of Bi$_{1.8}$Pb$_{0.4}$Sr$_2$Ca$_{2.2}$Cu$_3$O$_8$ were post-annealed at various temperature, oxygen partial pressure, and annealing time. The 2$^{nd}$ phases in the annealed specimen were analysed with XRD, SEM, TEM, and EDS. The size and the distribution of the precipitates such as (Ca,Sr)$_2$(Pb,Bi)O$_4$ and Bi$_{0.5}$Pb$_3$Sr$_2$Ca$_2$CuO$_{12+{\delta}}$ (3221) in the Bi-2223 matrix was controllable by varying heat-treatment condition without breaking the connectivity of the 2223 grains. The nano-size precipitates within the 2223 grains are conjectured as working as flux-pinning sites, resulting in increased J$_c$ value.

  • PDF

Performance Evaluation of the Multistage Soil Washing Efficiency for Remediation of Mixed-contaminated Soil with Oil and Heavy Metals (유류/중금속 복합오염토양 정화를 위한 다단 토양세척 효율평가)

  • Kim, Daeho;Park, Kwangjin;Cho, Sungheui;Kim, Chikyung
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.2
    • /
    • pp.33-40
    • /
    • 2017
  • In typical remediation practices, separate washing systems have to be applied to clean up the soils contaminated with both oil and heavy metals. In this study, we evaluated the efficiency of successive two-stage soil washing in removal of mixed-contaminants from soil matrix. Two-stage soil washing experiments were conducted using different combinations of chemical agent: 1) persulfate oxidation, followed by organic acid washing, and 2) Fenton oxidation, followed by inorganic acid washing. Persulfate oxidation-organic acid washing efficiently removed both organic and inorganic contaminants to meet the regulatory soil quality standard. The average removal rates of total petroleum hydrocarbons (TPH), Cu, Pb, and Zn were 88.9%, 82.2%, 77.5%, and 66.3% respectively, (S/L 1:10, reaction time 1 h, persulfate 0.5 M, persulfate:activator 3:1, citric acid 2 M). Fenton oxidation-inorganic acid washing also gave satisfactory performances to give 89%, 80.9%, 87.1%, and 67.7% removal of TPH, Cu, Pb, and Zn, respectively (S/L 1:10, reaction time 1 hr, hydrogen peroxide 0.3 M, hydrogen peroxide:activator 5:1, inorganic acid 1 M).

Study on Joint of Micro Solder Bump for Application of Flexible Electronics (플렉시블 전자기기 응용을 위한 미세 솔더 범프 접합부에 관한 연구)

  • Ko, Yong-Ho;Kim, Min-Su;Kim, Taek-Soo;Bang, Jung-Hwan;Lee, Chang-Woo
    • Journal of Welding and Joining
    • /
    • v.31 no.3
    • /
    • pp.4-10
    • /
    • 2013
  • In electronic industry, the trend of future electronics will be flexible, bendable, wearable electronics. Until now, there is few study on bonding technology and reliability of bonding joint between chip with micro solder bump and flexible substrate. In this study, we investigated joint properties of Si chip with eutectic Sn-58Bi solder bump on Cu pillar bump bonded on flexible substrate finished with ENIG by flip chip process. After flip chip bonding, we observed microstructure of bump joint by SEM and then evaluated properties of bump joint by die shear test, thermal shock test, and bending test. After thermal shock test, we observed that crack initiated between $Cu_6Sn_5IMC$ and Sn-Bi solder and then propagated within Sn-Bi solder and/or interface between IMC and solder. On the other hands, We observed that fracture propated at interface between Ni3Sn4 IMC and solder and/or in solder matrix after bending test.

Quantification of $Cu(In_xGa_{1-x})Se_2$ Solar Cell by SIMS

  • Jang, Jong-Shik;Hwang, Hye-Hyen;Kang, Hee-Jae;Min, Hyung-Sik;Han, Myung-Sub;Suh, Jung-Ki;Cho, Kyung-Haeng;Chung, Yong-Duck;Kim, Je-Ha;Kim, Kyung-Joong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.275-275
    • /
    • 2012
  • The relative composition of $Cu(InGa)Se_2$ solar cells is one of the most important measurement issues. However, quantitative analysis of multi-component alloy films is difficult by surface analysis methods due to severe matrix effect. In this study, quantitative depth profiling analysis of CIGS films was investigated by secondary ion mass spectrometry (SIMS). The compositions were measured by SIMS using the alloy reference relative sensitivity factors derived from the certified compositions and the total counting numbers of each element. The compositions measured by SIMS were linearly proportional to those by inductively coupled plasma-mass spectrometry (ICP-MS) using isotope dilution method. In this study, the quantification measured by ICP-MS method is compared with the composition calculated by SIMS depth profiles with AR-RSFs obtained from the reference. The SIMS depth profile of CIGS thin films according to the manufacturing condition was converted into compositional depth profile.

  • PDF

Effect of Alloying Elements on the Wear Resistance of Austempered Ductile Iron (오스템퍼링 처리한 구상흑연주철(ADI)의 내마모성에 미치는 합금원소의 영향에 관한 연구)

  • Lee, Sang-Hak;Kim, Hong-Beom;Kim, Jong-Chul;Chun, Byung-Wook;Kim, Chang-Gyu;Choi, Chang-Ock
    • Journal of Korea Foundry Society
    • /
    • v.19 no.1
    • /
    • pp.24-32
    • /
    • 1999
  • A series of investigations for Austempered Ductile Iron (ADI) castings were carried out by using the specimens with various chemical compositions and heat treatment conditions. The rolling wear characteristics of alloyed austempered ductile irons under an unlubricated dry rolling condition was evaluated by the Amsler type test with 9.09% sliding ratio. Generally, the wear amount was increased with the austempering temperature and decreased when the hardness of the matrix was higher. The alloying elements also influenced the austempering reaction, the microstructure and the mechanical properties. In this study, the mechanical properties (i.e.) ultimate tensile strength (UTS), hardness, elongation) and the wear resistance are analysed to show the relationship between the alloying elements and the austempering temperatures. Mo, Cu and Ni are alloyed individually or in combination. It has been found that when Cu and Ni alloyed individually to a casting, the wear amount is increased than others with elements alloyed in combination. The amount of rolling wear loss was decreased when Mo was alloyed in cast iron, individually or in combination.

  • PDF

A Study on the Complementary Alloying Design of Wear Resistant CV Graphite Cast Irons (내마모 CV흑연주철의 합금설계)

  • Park, Heung-Il;Kim, Woo-Yeol;Bae, Cha-Hurn;Kim, Myung-Ho
    • Journal of Korea Foundry Society
    • /
    • v.13 no.4
    • /
    • pp.333-341
    • /
    • 1993
  • The effects of alloying elements on the structure and mechanical properties of compacted/vermicular graphite cast irons containing copper, tin and molubdenum for producing pearlite matrix, and also containing phosphorus and boron for increasing wear resistance, were investigated. The Brinell hardness and ultimate tensile strength of the specimens with the range of compositions, [1.5% Cu-0.05% Sn-(0.2-0.4)% Mo-(0.2-0.6)% P-(0.035-0.070)% B], was found to fall within in the following range, depending on their composition; Brinell hardness of BHN 250-315, ultimate tensile strength of $28.1-40.3kg/mm^2$. It was also found within this experiment that CV graphite cast irons possessing higher amount of phosphide eutectic exhibit better wear resistance, but the wear resistance became deteriorate when the area fraction of phosphide eutectics exceed more than 10%. From these experimental results, it could be concluded that the CV graphite cast iron containing 1.5% Cu, 0.05% Sn, 0.4% Mo, 0.2% P and 0.035% B showed good mechanical and wear resistance properties.

  • PDF

Untersuchungen Zur Herstellung Von Neun Messpraparaten Fur Die Rontgenfluoreszenzspektrometrie (X-線 螢光分析에 있어서의 새로운 試料 調制에 關한 硏究)

  • Park, Yung-Kyu
    • Journal of the Korean Chemical Society
    • /
    • v.11 no.4
    • /
    • pp.165-169
    • /
    • 1967
  • Eine neue Methode zur Herstellung von Meßpraparation wird die Bestimmng der Spurenelemente Quecksilber, Kupfer, Blei, Zink, Nickel, Kobalt und Eisen durch Rontgenflureszenzspektrometrie entwickelt. Die Spurenelemente werden aus waßrigen Losungen durch Einleitung von Schwefelwasserstoff mit Aluminiumsulfat als Trager bei pH8 ausgefallt. Die Niederschlage der Metallsulfide werden uber Membranfilter filtriert, mit Gelatine fixiert und ihre Absolutmengen durch Rontgenfluoreszenz analyse bestimmt. Bei der geringen Dicke der auszumessenden Schichten treten Matrixeffekte nicht auf. Durch den Zusatz von Aluminiumsulfat-Trager wird eine gute Reproduzierbarkeit erzielt: Quecksilber, Kupfer, Blei, Zink, Nickel und Kobalt werden bei einer Konzentration von 50 bis 1000 p.p.b. mit einer relativen Standard-abweichung von 5.0% und Eisen bei einer Konzentration von 50∼1000 p.p.d. mit einer relativen Standardabweichung von 6.1% gemessen.

  • PDF

Study on Solvent Extraction Using Salen(NEt2)2 as a Chelating Agent for Determination of Trace Cu(II), Mn(II), and Zn(II) in Water Samples

  • In, Gyo;Kim, Young-Sang;Choi, Jong-Moon
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.5
    • /
    • pp.969-973
    • /
    • 2008
  • Solvent extraction using a Schiff-base, salen$(NEt_2)_2$, as a chelating agent has been conducted on several water samples to study the determination of trace Cu(II), Mn(II) and Zn(II). Experimental conditions for the formation and extraction of metal complexes were optimized with an aqueous solution similar in composition to the samples. The matrix difference between the sample and standard solutions was approximately matched, and the pH of each sample solution was adjusted to 9.5 with $NaHCO_3/NaOH$ buffer. The concentration of salen$(NEt_2)_2$ was $7.3\;{\times}\;10^{-3}$ mol/L, and the complexes were extracted into MIBK solvent followed by the measurement of AAS absorbance. The potential interference of concomitant ions was investigated, but no interference from alkaline and alkali earth ions was shown in this procedure. The given procedure is precise, as judged from the relative standard deviation of less than 5% for five measured data. The recovery of 93-103% shows that this method is quantitative for such trace metal analysis.