• 제목/요약/키워드: Crown inclination

검색결과 47건 처리시간 0.016초

정상 교합자의 치관 경사도에 관한 연구 (A STUDY OF THE CROWN INCLINATION IN NORMAL OCCLUSIONS)

  • 정돈영;손병화;박영철
    • 대한치과교정학회지
    • /
    • 제16권1호
    • /
    • pp.155-165
    • /
    • 1986
  • Recently, straight-wire appliance is widely used with great concern in clinical orthodontic field. The purpose of this study was to collect the information of the straight-wire appliance and to determine the crown inclination in clinical orthodontics. The author analyzed the study model of 78 individuals with normal occlusion. The obtained results were as follows. 1. Mean, maximum value, minimum value and standard deviation of crown inclination of upper and lower teeth were obtained. 2. The lingual crown inclination of upper tooth had constant value from first premolar through second molar, the lingual crown inclination of lower tooth progressively increased from canine through second molar. 3. As Howes' ratio was decreased, the crown inclination of upper incisors was increased. 4. Narrowing the upper arch, the crown inclination of upper incisors was increased.

  • PDF

Relationships between the upper central incisor crown forms and degree of labial inclination, overbite, and overjet in Japanese young adults

  • Kurita, Takeshi;Mizuhashi, Fumi;Sato, Toshihide;Koide, Kaoru
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권6호
    • /
    • pp.338-343
    • /
    • 2020
  • PURPOSE. The present study aimed to investigate the relationships between the crown form of the upper central incisor and their labial inclination, overbite, and overjet. MATERIALS AND METHODS. Maxillary and mandibular casts of 169 healthy dentitions were subjected to 3D dental scanning, and analyzed using CAD software. The crown forms were divided into tapered, square, and ovoid based on the mesiodistal dimensions at 20% of the crown height to that at 40%. The degree of labial inclination of the upper central incisor was defined as the angle between the occlusal plane and the line connecting the incisal edge and tooth cervix. The incisal edges of the right upper and lower central incisor that in contact with lines parallel to the occlusal plane were used to determine the overbite and overjet. One-way ANOVA was performed to compare the labial inclination, overbite, and overjet among the crown forms. RESULTS. The crown forms were classified into three types; crown forms with a 20%/40% dimension ratio of 1.00±0.01 were defined as square, >1.01 as tapered, and <0.99 as ovoid. The labial inclination degree was the greatest in tapered and the least in square. Both overbite and overjet in tapered and ovoid were higher than those in square. CONCLUSION. Upper central incisor crown forms were related to their labial inclination, overbite, and overjet. It was suggested that the labial inclination, overbite, and overjet should be taken into consideration for the prosthetic treatment or restoring the front teeth crowns.

20대 여성 정상교합자에서 임상치관의 순·설측 경사도와 근·원심 경사도에 관한 연구 (A Study on Clinical Crown Angulation and Inclination of Females in the Twenties with Normal Occlusion)

  • 조홍규
    • 대한치과기공학회지
    • /
    • 제35권4호
    • /
    • pp.415-424
    • /
    • 2013
  • Purpose: This study is to present a standard value for clinical crown angulation and inclination required in laboratory process and see if the value can be used for actual laboratory process. Methods: In order to find out a standard value for clinical crown angulation and inclination, this study made a study model of normal occlusion of 21 females in twenties. The clinical crown angulation and inclination of both six-maxillary and six-mandibular anterior teeth are measured by Set-up Model Checker. From the measured value above, the mean and standard deviation of the twelve teeth are obtained, and then the mean of the teeth between right and left side is calculated. Results: Each clinical crown angulation of maxillary central incisor, lateral incisor, and canine is like this; $1.0^{\circ}{\pm}1.3^{\circ}$, $3.0^{\circ}{\pm}1.3^{\circ}$, and $5.0^{\circ}{\pm}1.4^{\circ}$. In case of mandibular, each degree is like this; $0.6^{\circ}{\pm}1.1^{\circ}$, $1.5^{\circ}{\pm}1.1^{\circ}$, and $4.1^{\circ}{\pm}1.1^{\circ}$. Each clinical crown inclination of maxillary central incisor, lateral incisor, and canine is like this; $6.1^{\circ}{\pm}1.8^{\circ}$, $4.5^{\circ}{\pm}1.9^{\circ}$, and $-6.2^{\circ}{\pm}1.4^{\circ}$. In case of mandibular, each degree is like this; $0.3^{\circ}{\pm}1.5^{\circ}$, $0.3^{\circ}{\pm}1.8^{\circ}$, and $-7.5^{\circ}{\pm}1.8^{\circ}$. Conclusion: As the result, the mean value for clinical crown angulation and inclination can be referred to actual laboratory process. However, the mean value is different from those of the precedent study and an unsatisfied one for adopting the standard value.

한국인 정상교합자의 치관경사도에 관한 임상통계학적 연구 (A STATISTICAL STUDY OF CLINICAL CROWN INCLINATION IN KOREAN'S NATURALLY OCCURRING OPTIMAL OCCLUSION)

  • 김종성;진근호;홍성준
    • 대한치과교정학회지
    • /
    • 제22권3호
    • /
    • pp.715-733
    • /
    • 1992
  • The objective of this study was to evaluate some clinical aspect of the crown inclination in Korean's naturally occuring optimal occlusion, and to statistically compare the crown inclination at Andrews' FA points group and another bracket slot level group based on marginal ridges. The materials consisted of study models of 30 patients (14; Korean's males, 16; Korean's females) who have nonorthodontic normal occlusion. The results were as follows; 1. Mean, standard deviation, range of clinical inclination in the Andrews' FA points and another bracket slot level were obtained. 2. Statistically difference between Andrews' FA points group and bracket slot level group based on marginal ridge was non significant (p > 0.05). But standard deviation and range in FA points group was more stability than marginal ridge group. 3. A lingual crown inclination at FA points in the upper posterior teeth existed (canines through molars). 4. The lingual crown inclination at FA points in the lower dentition progressively increased from the incisors through the second molars.

  • PDF

IPS Empress 도재관의 파절강도 : 상악제1소구치에서 교합면 두께와 축면 경사도에 따른 영향 (FRACTURE STRENGTH OF THE IPS EMPRESS CROWN:THE EFFECT OF OCCLUSAL DEPTH AND AXIAL INCLINATION ON UPPER FIRST PREMOLAR CROWNS)

  • 동진근;오상천;김상돈
    • 대한치과보철학회지
    • /
    • 제37권1호
    • /
    • pp.127-133
    • /
    • 1999
  • The purpose of this study was to compare the fracture strength of the IPS Empress ceramic crown according to the occlusal depth (1.5mm, 2.0mm, 2.5mm) and axial inclination ($4^{\circ},\;8^{\circ},\;12^{\circ}$) of the upper first premolar. After 10 metal dies were made fir each group, the IPS Empress ceramic crowns were fabricated and each crown was cemented on each metal die with resin cement. The cemented crowns mounted on the testing jig were inclined 30 degrees and a universal testing machine was used to measure the fracture strength. The results were : 1. The fracture strength of the ceramic crown with 2.5mm depth and $12^{\circ}$ inclination was the highest (630N). Crowns of 1.5mm depth and $4^{\circ}$ inclination had the lowest strength(378N). There were no significant differences of the fracture strength by axial inclination in same occlusal depth group. 2. The fracture mode of the crowns was similar. Most of fracture lines began at the loading area and extended through proximal surface perpendicular to the margin, irrespective of occlusal depth.

  • PDF

Straight Wire Appliance를 위한 한국인 정상교합자의 치관 형태에 관한 연구 (A MORPHOMETRIC STUDY OF TEETH ON THE KOREAN NORMAL OCCLUSION)

  • 이원유;박영철;임경수
    • 대한치과교정학회지
    • /
    • 제28권4호
    • /
    • pp.601-609
    • /
    • 1998
  • 한국인에 적합한 preadjusted bracket을 개발하기 위하여 한국인 성인 정상 교합자 14명을 대상으로 crown angulation, inclination, in and out, molar offset angle을 구했다. 정상 교합자 14명의 cast를 3차원 스케닝한 후 스케닝한 모델을 대상으로 컴퓨터 프로그램을 이용하여 측정하였다. 이는 기존의 모델을 직접 수작업으로 측정할 때보다 정확하고 빨리 측정할 수 있었다. 다음과 같은 결론을 얻었다. 1. 한국인 정상교합자의 각 치아의 치축 경사(angulation), 치관 경사도(inclination), in and out, molar offset angle을 구하였다. 2. 3차원 스케너와 컴퓨터를 이용하여 측정하였기 때문에 보다 정확하고, 빠르게 측정할 수 있었다.

  • PDF

IPS Empress 도재관의 파절강도 : 상악 제1대구치에서 교합면 두께와 축면경사도에 따른 영향 (FRACTURE STRENGTH OF THE IPS EMPRESS CROWN: THE EFFECT OF OCCLUSAL DEPTH AND AXIAL INCLINATION ON UPPER FIRST MOLAR)

  • 최택림;이해형;동진근
    • 대한치과보철학회지
    • /
    • 제39권2호
    • /
    • pp.171-183
    • /
    • 2001
  • The purpose of this study was compare the fracture strength of the IPS Empress ceramic crown according to the occlusal depth (1.5mm, 2.0mm, 2.5mm) and axial inclination ($4^{\circ},\;8^{\circ},\;12^{\circ}$) of the upper first molar. After 10 metal dies were made for each group, the IPS Empress ceramic crowns were fabricated and were cemented with resin cement. The cemented crowns mounted on the testing jig were inclined 30 degrees and a universal testing machine was used to measure the fracture strength. The results of this study were as follows: 1. The fracture strength of the ceramic crown with 2.5mm depth and $8^{\circ}$ inclination was the highest (1393N). Crowns of 1.5mm depth and $4^{\circ}$ inclination had the lowest strength (1015N) 2. There were no significant differences of the fracture strength according to occlusal depth and axial inclination. 3. Most fracture lines began at the loading area and extended through proximal surface perpendicular to the margin, irrespective of occlusal depth. 4. There was positive correlation between the fracture strength and the fracture surface area of crowns.

  • PDF

IPS Empress 도재관의 파절강도 : 상악 견치에서 절단연 삭제량과 축면 경사도에 따른 영향 (FRACTURE STRENGTH OF THE IPS EMPRESS CROWN : THE EFFECTS OF INCISAL REDUCTION AND AXIAL INCLINATION ON UPPER CANINE)

  • 신동국;강한중;박용석;박광수;동진근
    • 대한치과보철학회지
    • /
    • 제43권1호
    • /
    • pp.30-40
    • /
    • 2005
  • Purpose. The purpose of this study was to compare the fracture strength of the IPS Empress ceramic crown according to the incisal reduction (2.0mm, 2.5mm, 3.0mm) and axial inclination ($4^{\circ}$, $8^{\circ}$, $12^{\circ}$) of the upper canine. Material and methods. After 10 metal dies were made for each group, the IPS Empress ceramic crowns were fabricated and each crown was cemented on each metal die with resin cement. The cemented crowns mounted on the testing jig were inclined 30 degrees and the universal testing machine was used to measure the fracture strength. Results. 1. The fracture strength of the ceramic crown with 3.0mm depth and $12^{\circ}$ inclination was the highest (839N) Crowns of 2.0mm depth and $12^{\circ}$ inclination had the lowest strength (559N). 2. There was no significant difference in the fracture strength by axial inclination in the same incisal reduction group. 3. The fracture mode of the crowns was similar. Most of fracture lines began at the loading area and extended through proximal surface perpendicular to the margin irrespective of incisal reduction.

IPS Empress 도재관의 파절강도 : 하악 제2소구치에서 교합면 두께와 축면 경사도에 따른 영향 (FRACTURE STRENGTH OF THE IPS EMPRESS CROWN : THE EFFECT OF OCCLUSAL DEPTH AND AXIAL INCLINATION ON LOWER SECOND PREMOLAR)

  • 김희진;이해형;남영성;동진근
    • 대한치과보철학회지
    • /
    • 제40권5호
    • /
    • pp.441-450
    • /
    • 2002
  • The purpose of this study was compare the fracture strength of the IPS Empress ceramic crown according to the occlusal depth (1.5mm, 2.0mm, 2.5mm) and axial inclination ($4^{\circ},\;8^{\circ},\;12^{\circ}$) of the lower second premolar. After 10 metal dies were made for each group, the IPS Empress ceramic crowns were fabricated and cemented with resin cement. The cemented crowns were mounted on the testing jig with inclination of 30 degrees and the universal testing machine was used to measure the fracture strength. The results of this study were as follows : 1. The fracture strength of the ceramic crown with 2.5mm depth and $12^{\circ}$ inclination was the highest (1284 N). Crowns of 1.5mm depth and $8^{\circ}$ inclination had the lowest strength (951 N). 2. There were no significant differences in the fracture strength by axial inclination of the same occlusal depth group. 3. Most fracture lines began at the loading area and extended through proximal surface perpendicular to the margin, irrespective of occlusal depth.

IPS Empress 도재관의 파절강도: 하악 제1대구치에서 교합면 두께와 축면경사도에 따른 영향 (FRACTURE STRENGTH OF THE IPS EMPRESS CROWN : THE EFFECT OF OCCLUSAL DEPTH AND AXIAL INCLINATION ON LOWER FIRST MOLAR)

  • 김성훈;이진한;김유리;동진근
    • 대한치과보철학회지
    • /
    • 제41권1호
    • /
    • pp.48-60
    • /
    • 2003
  • The purpose of this study was to compare the fracture strength of the IPS Empress ceramic crown according to the occlusal depth (1.5mm, 2.0mm, 2.5mm) and axial inclination ($4^{\circ},\;8^{\circ},\;12^{\circ}$) of the lower First Molar. After 10 metal dies were made for each group, the IPS Empress ceramic crowns were fabricated and cemented with resin cement(Bistite resin cement, Tokuyama Soda Co. LTD., Japan). The cemented crowns were mounted on the testing jig with inclination of 30 degrees and the universal testing machine(Zwick Z020, Zwick, Germany)was used to measure the fracture strength. The results of this study were as follows : 1. The fracture strength of the ceramic crown with 2.5mm depth and $12^{\circ}$ inclination was the highest (1789 N). Crowns of 1.5mm depth and $4^{\circ}$ inclination had the lowest strength (1091 N). 2. There were no significant differences in the fracture strength by axial inclination of the same occlusal depth group. 3. Most fracture lines began at the loading area and extended through proximal surface perpendicular to the margin, irrespective of occlusal depth. Size of fragment was affected by the amount of occlusal reduction.