A COMPARISON OF THE FIDELITY BETWEEN VARIOUS CORES FABRICATED WITH CAD/CAM SYSTEMS

  • Park, Sun-Hee;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.269-279
    • /
    • 2008
  • STATEMENT OF PROBLEM: Recently, various all-ceramic crowns fabricated with CAD/CAM systems have come into wide use in dental clinic. However, there are only few domestic studies on CAD/CAM restorations. PURPOSE: Purpose of this study was to compare the fidelity (absolute marginal discrepancy and internal gap) between various cores fabricated with different CAD/CAM systems (Procera system, Lava system, Cerec inLab system) and conventional metal cast core. MATERIALS AND METHODS: 10 cores per each system were fabricated. The absolute marginal discrepancies were measured using measuring microscope and digital counter. The internal gaps were calculated using a silicone paste. The results were statistically analyzed using the one-way ANOVA test and Tukey's HSD test. RESULTS: Within the limits of this study the results were as follows. 1. The absolute marginal discrepancies were $32.5{\pm}3.7\;{\mu}m$ for metal cast core, $72.2{\pm}7.0\;{\mu}m$ for Procera core, $40.8{\pm}5.4\;{\mu}m$ for Lava core, and $55.3{\pm}8.7\;{\mu}m$ for Cerec inLab core. The internal gaps were $38.4{\pm}5.7\;{\mu}m$ for metal cast core, $71.4{\pm}5.3\;{\mu}m$ for Procera core, $45.9{\pm}7.3\;{\mu}m$ for Lava core, and $51.8{\pm}6.2\;{\mu}m$ for Cerec inLab core. 2. The fidelity of metal cast core showed the smallest gaps, followed by Lava core, Cerec inLab core, and Procera core. CONCLUSION: The fidelities of 4 core groups were all within the clinically acceptable range ($120\;{\mu}m$).

Verification of a computer-aided replica technique for evaluating prosthesis adaptation using statistical agreement analysis

  • Mai, Hang-Nga;Lee, Kyeong Eun;Lee, Kyu-Bok;Jeong, Seung-Mi;Lee, Seok-Jae;Lee, Cheong-Hee;An, Seo-Young;Lee, Du-Hyeong
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.5
    • /
    • pp.358-363
    • /
    • 2017
  • PURPOSE. The purpose of this study was to evaluate the reliability of computer-aided replica technique (CART) by calculating its agreement with the replica technique (RT), using statistical agreement analysis. MATERIALS AND METHODS. A prepared metal die and a metal crown were fabricated. The gap between the restoration and abutment was replicated using silicone indicator paste (n = 25). Gap measurements differed in the control (RT) and experimental (CART) groups. In the RT group, the silicone replica was manually sectioned, and the marginal and occlusal gaps were measured using a microscope. In the CART group, the gap was digitized using optical scanning and image superimposition, and the gaps were measured using a software program. The agreement between the measurement techniques was evaluated by using the 95% Bland-Altman limits of agreement and concordance correlation coefficients (CCC). The least acceptable CCC was 0.90. RESULTS. The RT and CART groups showed linear association, with a strong positive correlation in gap measurements, but without significant differences. The 95% limits of agreement between the paired gap measurements were 3.84% and 7.08% of the mean. The lower 95% confidence limits of CCC were 0.9676 and 0.9188 for the marginal and occlusal gap measurements, respectively, and the values were greater than the allowed limit. CONCLUSION. The CART is a reliable digital approach for evaluating the fit accuracy of fixed dental prostheses.

REPOSITIONING OF A LINGUALLY DISPLACED MANDIBULAR FIRST PRIMARY MOLAR BY TRAUMA (외상에 의해 설측 변위된 하악 제1유구치의 가철성 장치를 이용한 치료)

  • Lee, Myung-Sung;Lee, Keung-Ho;Choi, Yeong-Chul;Park, Jae-Hong
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.1
    • /
    • pp.119-125
    • /
    • 2005
  • In the primary dentitions, the majority of dental injuries involve the anterior teeth, especially the maxillary primary central incisors. When injuries affecting primary and permanent teeth are compared, it appears that trauma to the primary dentition is usually confined to the supporting structures, i.e. luxation and exarticulation, while the largest proportion of injuries affecting the permanent dentition is represented by crown fractures. But, cases reporting trauma affecting primary molars are unusual in the literature and several reports describe fractures of posterior teeth. The main goal of this report is to describe the repositioning treatment using removable appliances to an uncommon case of lingual displacement of primary molar that happened to a 4 year 5 month-old female child.

  • PDF

CASE REPORTS : TALON CUSP (증례 보고-Talon Cusp)

  • Min, Yu-Jin;Kim, Jong-Su
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.1
    • /
    • pp.46-51
    • /
    • 2004
  • Talon cusp is cusp-like structure that develops additionally in crown of anterior tooth. And it is one of dental anomalies. Talon cusp can cause various diagnostic, functional, aesthetic problems depending on the size and configuration of cusp. there is a tendency for caries to occur in the developmental grooves, and advanced attrition, periodontal problems, irritation the tongue and temporomandibular pain, occlusal interference and displacement of affected tooth may result. Therefore, early diagnosis and appropriate treatment of each case is important so that it minimize local problems, such as caries, periodontal diseases, and malocclusion. These cases which are in permanent and primary anterior teeth are about gradual reduction forming reparative dentine and complete reduction of talon cusp and root canal therapy which is an alternative and effective form of treatment when gradual reduction of talon cusp may not be possible.

  • PDF

Evaluation of the Time and Pouring Frequency Dependent Dimensional Stability of Additional Silicone Impression Materials. (인상채득 후 시간경과와 반복주입에 따른 부가중합형 실리콘 인상재의 체적변화)

  • Choi, Mee-ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.3
    • /
    • pp.239-248
    • /
    • 2007
  • The accuracy and dimensional stability of rubber impression materials are very important for the fitness of the final restoration. The purpose of this investigation was to evaluate the effects of the storage time and pouring frequency of the additional silicone materials on dimensional stability. Total 30 impressions were made of tooth prepared single crown. The dies had 1 buccolingual, 1 mesiodistal and 1 occlusogingival lines. Two additional silicone materials(examixfine, aquasil) were included. 15 specimens were made of each impression material and poured by type IV stone over times(1hour, 24hours, 72hours) after mixing. 5 impressions poured after 1 hour were used for second pouring after 24hours and third pouring after 72hours. The same examiner measured each specimen 3 times after lazer scanning. All statistical tests were performed with the level of significance set at 0.05. The results indicated that significant difference at any measuring point of stone dies except the buccolingual and mesiodistal lines of the specimen made at 1hour after mixing with examixfine when measurements at 1hour, 24hours and 72hours were campared. There were significant difference between two impression materials and at every measuring point of stone dies made at second and third pouring. The length of measuring point increased significantly as time passed by and increase of the pouring frequency. However, this results are clinically acceptable except the dies of the third pouring. Under the conditions of this study, the shrinkage rate of the additional silicone rubber impression materials significantly increased as time passed by and increase of the pouring frequency.

Investigation of Age and Treatment Modalities in the Periodontally Treated(1981-1995) Patients (치주치료를 받은(1981-1995) 환자들의 연령과 치료술식에 대한 조사 연구)

  • Lee, Young-Seok;Yun, Chang-Yup;Kim, Sang-Mok;Kim, Byung-Ock;Han, kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.1
    • /
    • pp.225-232
    • /
    • 2001
  • The aim of this study was to recommend the optimal age for prevention of periodontal disease and to investigate the trend of treatment modality according to different period. From the chart recordings of the patients who had been treated periodontally from Jan. 1981 to Dec. 1995 in the dept .of periodontics, Chosun University Dental Hospital, those of the periodontally treated patients on more than 4 sixtants were selected for the present study. The distribution of the patients was counted according to the age group and the gender. And they were divided into 3 groups(group 1: 1987-1958, group 2: 1985-1990, group 3: 1991-1995) by 5 year interval according to the treated year. The periodontal treatment modalities were classified into non-surgical therapy, pocket elimination surgery, regenerative periodontal surgery, mucoginigival surgery, clinical crown lengthening, and others. The results were as follows; 1.In the distribution of the periodontally treated patients according to the age group, 40's age group was the highest, and 30's, 40's, and 50's age groups occupied more than two thirds(73%). 2.The sexual distribution of the periodontally treated patients showed that males(53.4%) were a little more than females(46.6%). Within 20's group female was higher, but within 40's male was higher. 3.Regardless of the age group and the gender, pocket elimination surgery was the most frequent treatment modality. 4.In group 1 and 2(1987-1990) the main treatment modality was pocket elimination surgery and non-surgical therapy, but in group 3(1991-1995) it was regenerative periodontal surgery and pocket elimination surgery. The above results suggest that the prevention of periodontal disease should be initiated from early twenties, and the most frequent treatment modality may be closely related with development of new material and method.

  • PDF

Aesthetic restoration n patients with unaesthetic maxillary anterior teeth using double scan : A case report (비심미적인 상악 전치부 환자에서 이중 스캔을 이용한 심미보철 수복 증례)

  • Ko, Chang Woo;Kim, Min-Ji;Yang, Hong-So;Park, Sang-Won;Park, Chan;Yun, Kwi-Dug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.166-172
    • /
    • 2018
  • In case of the treatment of maxillary anterior teeth, it should be taken into account the proper morphology, arrangement and color satisfying patient's esthetic demands. For this purpose, facial composition, dentofacial composition, dental composition and dentogingival composition should be considered making diagnosis and treatment plan in an esthetic point of view. In adjustable temporary crown state, careful evaluation and correction of the esthetic and functional aspect were performed, and the definite restoration was reproduced using double scan.

Wound Healing After Gingivectomy Using Pulsed Nd : YAG Laser In The Rat (백서에서 Pulsed Nd : YAG Laser에 의한 치은절제술후의 치유양상)

  • Kim, Ok-Su;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.293-308
    • /
    • 1996
  • Recently, dental laser have been applied for removal of soft tissues, hemostasis and blood coagulation, removal of benign and malignant tumor, treatment of leukoplakia, aphthous ulcer and herpetic lesion, implant second surgery, removal of granulation tissue, frenectomy, clinical crown lengthening, gingivectomy, gingivoplasty, and treatment of dentin hypersensitivity. Even though the frequency of laser treatment is increasing, the research on the healing process after gingivectomy using pulsed Nd : YAG laser is very rare. The purpose of this study was to observe and compare the wound healing after gingivectomy using scalpel and pulsed Nd : YAG laser in the rat. Gingivectomy was performed using pulsed Nd : YAG laser(SUNRISE Technologies, U.S.A., 1.5 Watts, 10 pps) on the buccal gingiva of right maxillary first molar and using scalpel(No.12) on the contralateral side. Those sites treated by surgical scalpel were designated as the control, and by pulsed Nd : YAG laser as the experimental group. Animals were sacrificed at 1, 2, 3, 5, 7, 11 and 14 days postoperatively, and specimens were histologically observed under light microscope. The results were as follows : 1. Clinical observation Normal color and shape were observed at the 5th day ill the control group and the 7th day in the experimental group. 2. Histologic findings 1) In the control group, denser inflammatory infiltration was observed. 2) Epithelialization started at the 2nd day in the control group, similar to the experimental group, and completed at the 11th to the 14th day postoperatively. 3) In the experimental group, connective tissue showed the vacuole formation and degenerative change during early healing period. Healing of connective tissue was slower in the experimental group than in the control group by 2 days. 4) In the both groups, wound healing was completed at the 2nd week. From this study, gingivectomy using pulsed Nd : YAG laser seems to result in a little delayed wound healing process, compared to the gingivectomy using scalpel. Considering the clinical advantages of laser surgery, pulsed Nd : YAG laser might be useful device for gingivectomy.

  • PDF

A Case Report of Maxillary Complete Edentulous Patient with a Class III Jaw Relations (III급 악골 관계를 가진 상악 편악 무치악 환자의 수복)

  • Park, Mi-hee;Hong, Jun-won;Choi, Jee-ha;Lee, Jung-jun;Park, Ju-mi;Song, Kwang-yeob;Ahn, Seung-geun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.431-436
    • /
    • 2009
  • In a case of class III skeletal patients with severe alveolar bone resorption, it must be a complete denture treatment plan provided stable and durable occlusion. Despite a markedly increased tooth mobility and unfavorable crown-to-root ration due to periodontal tissue breakdown, if the inflammatory process is controlled and an adequate oral hygiene performed, fixed splints will be considered. Patient's discomfort will be eliminated by achievement better clinical tooth mobility using fixed splints. So it can be a cost and time effective treatment option. In this case, it used a T-Scan System for confirmation a bilateral balanced occlusion and a occlusal force distribution reflected a patient's functional mandibular movement.

Investigation of the Regression Analysis Method for a Quantitative Evaluation of Implant Crestal Bone Stresses (회귀분석법에 의한 임플란트 경부골 응력의 정량적 분석에 대한 연구)

  • Kim, Woo-Shik;Jo, Kwang-Hun;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.3
    • /
    • pp.299-310
    • /
    • 2008
  • In this study, the regression analysis method was tested for the estimation of peak stress at stress concentration area in the cervical bone. Submerge type EZ plus implant (Megagen. Daegu, Korea), 4.1 mm in cervical diameter and 9.6 mm in endosseous length, were axisymmetrically modelled together with surrounding alveolar bone of which the width was 10 mm. Vertical force of 100 N was applied to a head of crown above 8.5 mm from the outer surface of the cortical bone. Four different mesh models were composed of differently sized elements in vicinity of sharp corners, and they include 6 stress monitoring points that are located in the same geometrical points regardless of the differences in the meshes. Primary consideration was given to the stresses in the cortical bone surrounding the implant neck. The results showed that virtually all the stresses were concentrated in the cortical bone regardless of mesh designs. The peak stresses were successfully calculated by a regression analysis in a stable manner, as far as the mesh is designed to represent the acute gradient of stresses near the sharp corner.