• Title/Summary/Keyword: Cross-sensitivity

Search Result 597, Processing Time 0.03 seconds

Design Sensitivity Analysis and Optimal Design to Control Forced Harmonic Vibration of Structure (구조물 진동제어를 위한 설계 민감도해석 및 최적설계)

  • J.H. Lee;K.H. Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.32 no.4
    • /
    • pp.64-72
    • /
    • 1995
  • Sizing design sensitivity analysis of structures subjected to the harmonic vibration is performed using adjoint variable method. Constraint is the stress and sizing design variables are thickness, bending moment of inertia, and cross-sectional area of structures. Accurate sensitivities are computed and plotted sensitivity can be used as a design guidance tool. The accuracy of sensitivities is verified by the finite difference values. Also, optimal design of three-bar structure is performed using the computed sensitivity and feasible direction method while satisfying constraints and obtaining the minimum weight.

  • PDF

Novel graphene-based optical MEMS accelerometer dependent on intensity modulation

  • Ahmadian, Mehdi;Jafari, Kian;Sharifi, Mohammad Javad
    • ETRI Journal
    • /
    • v.40 no.6
    • /
    • pp.794-801
    • /
    • 2018
  • This paper proposes a novel graphene-based optical microelectromechanical systems MEMS accelerometer that is dependent on the intensity modulation and optical properties of graphene. The designed sensing system includes a multilayer graphene finger, a laser diode (LD) light source, a photodiode, and integrated optical waveguides. The proposed accelerometer provides several advantages, such as negligible cross-axis sensitivity, appropriate linearity behavior in the operation range, a relatively broad measurement range, and a significantly wider bandwidth when compared with other important contributions in the literature. Furthermore, the functional characteristics of the proposed device are designed analytically, and are then confirmed using numerical methods. Based on the simulation results, the functional characteristics are as follows: a mechanical sensitivity of 1,019 nm/g, an optical sensitivity of 145.7 %/g, a resonance frequency of 15,553 Hz, a bandwidth of 7 kHz, and a measurement range of ${\pm}10g$. Owing to the obtained functional characteristics, the proposed device is suitable for several applications in which high sensitivity and wide bandwidth are required simultaneously.

Cultural Knowledge, Empathy and Cultural Sensitivity of University Students Majoring in Health And Welfare (보건의료 및 복지 전공 대학생의 다문화 지식, 공감, 문화적 민감성에 관한 연구)

  • Oh, Won-Oak;Jung, Woo-Sik;Kang, Hyung-Gon;Kim, Eun-Hye;Suk, Min-Hyun
    • Journal of the Korean Society of School Health
    • /
    • v.23 no.2
    • /
    • pp.192-199
    • /
    • 2010
  • Purpose: Multi-cultural families are increasing highly in Korea. Health care professionals and students majoring in health and welfare need to develop their cultural competence for quality of life from multi-cultural families. This study was to be conducted by examining the level of culture knowledge, empathy, and cultural sensitivity of university students majoring in health and welfare. Methods: Convenience sampling method was used and 408 students from 3 universities were evaluated for final analysis. Data collection was conducted through the use of questionnaires. Results: The score of cultural knowledge of students was very low. Empathy and cultural sensitivity showed middle range. There was a significant correlation between cultural knowledge and empathy, empathy and cultural sensitivity. However, there was no significant correlations between cultural knowledge and cultural sensitivity. Conclusion: An understanding of multi-cultural enables health and welfare providers to specialize service in cross- cultural situations of multi-cultural families in Korea. Ways to improve cultural competence for students majoring in health care and welfare is needed.

Sensitivity analysis of melt spinning process by frequency response

  • Hyun, Jae-Chun;Jung, Hyun-Wook;Lee, Joo-Sung
    • Korea-Australia Rheology Journal
    • /
    • v.14 no.2
    • /
    • pp.57-62
    • /
    • 2002
  • The sensitivity of the final filament to the ongoing sinusoidal disturbances has been Investigated in the viscoelastic spinning using frequency response method. Amplification ratios or gains of the spinline cross-sectional area at the take-up to any disturbances show resonant peaks along the frequency regime, where the frequencies at theme points directly correspond to the imaginary parts of the successive leading eigenvalues from the linear stability analysis. As shown in Jung et al. (1999) and Lee et al (2001), the sensitivity results on the effect of various process conditions such as spinline cooling and fluid viscoelasticity, obtained by dynamic transient simulation have been corroborated in this study. That is, increasing spinline cooling makes the system less sensitive to disturbances, thus stabilizes the spinning. Also, an increasing viscoelasticity for extension-thickening fluids decreases the sensitivity of the spinning. i.e., stabilizing the system, where, as it increases the sensitivity of the spinning of extension-thinning fluids. Furthermore, it has been found in the present study that the inertia force as one of secondary forces causes the system to be more stabile or less sensitive to process disturbances.

Efficient DC Power Management Scheme using 60-GHz Rectenna (60-GHz 렉테나를 이용한 효율적 DC 전력 관리 체계)

  • Lim, Sung-Joon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.1032-1035
    • /
    • 2008
  • In this paper, a DC power management scheme is proposed for efficient battery operation of 60-GHz receivers. It consists of a rectenna and a zero-cross detector. The harmonic rejection capability of a circular sector antenna is used to simplify the rectenna. The zero-cross detector is introduced to increase sensitivity. When the received power density is larger than 0.013 $mW/cm^2$, it can generate enough DC power to activate an RF receiver. Experimental data is used to verify the proposed idea.

Cross-sectional comparison on human rights sensitivity changes in nursing students and non-nursing students (간호대학생과 일반대학생의 인권감수성 변화에 관한 횡단적 비교)

  • Kim, Seong-Eun
    • Journal of Digital Convergence
    • /
    • v.14 no.4
    • /
    • pp.355-362
    • /
    • 2016
  • This cross-sectional study examined the differences of the human rights sensitivity changes between freshmen and seniors of nursing and non-nursing Students. The data for this study were collected using a human rights sensitivity questionnaire developed by Moon answered by 178 nursing and non-nursing students from five South Korean universities. A t-test, chi-square test were performed on the collected data. There were no significant differences in the human rights sensitivity scores between freshmen and seniors in nursing and non-nursing students. There were significant differences in the human rights sensitivity scores in the right to privacy of the psychiatric patients and the environmental rights among nursing students. There were significant differences in the human rights sensitivity scores in the disabled person's physical liberty in non-nursing students. The results of this study suggested the direction of educational curriculum revision about ethics and development of educational programs to improve the human rights sensitivity.

Identification of Cross-WLF Viscosity Model Parameters Using Optimization Technique (최적화기법을 이용한 Cross-WLF점도 모델 계수 추정)

  • Kim, Sun-Yong;Park, Si-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.623-632
    • /
    • 2018
  • Predicting the behavior of rheological polymers is highly shear rate- and temperature-dependent. The Cross-WLF viscosity model has become a powerful solution that describes the shear rate- and temperature-dependent characteristics. To estimate the behavior of polymers in computational simulations, the coefficients of the Cross-WLF model should be well identified. An identification technique was proposed to determine the Cross-WLF viscosity model coefficient. The assumption is that the Cross-WLF viscosity model well describes the real characteristics of polymers when the calculated viscosity with the parameters is identical to the reference data. In this study, Auto-desk Moldflow data were used as a reference. The numerical examples showed that the proposed method accurately identifies the Cross-WLF viscosity model coefficients.

Performance Evaluation of the Automated Fluorescent Immunoassay System Rotavirus Assay in Clinical Samples

  • Kim, Jae-Seok;Lee, Su-Kyung;Ko, Dae-Hyun;Hyun, Jungwon;Kim, Hyun Soo
    • Annals of Laboratory Medicine
    • /
    • v.39 no.1
    • /
    • pp.50-57
    • /
    • 2019
  • Background: The Automated Fluorescent Immunoassay System (AFIAS) rotavirus assay (Boditech Med Inc., Chuncheon, Korea) is a new rapid antigen test for rotavirus detection. We evaluated the performance of this assay for detecting rotaviruses and their specific genotypes in clinical stool samples. Methods: AFIAS rotavirus assay was performed in 103 rotavirus-positive and 103 rotavirus-negative stool samples (confirmed by both PCR and ELISA), and its results were compared with those of PCR, ELISA, and immunochromatographic assay (ICA). We evaluated diagnostic sensitivity/specificity, the detectability of rotavirus subtypes, lower limit of detection (LLOD), reproducibility, cross-reactivity, and interference of AFIAS rotavirus assay. Results: Based on PCR and ELISA results, diagnostic sensitivity and specificity of the AFIAS rotavirus assay were both 99.0%. LLOD results showed that the AFIAS assay had sensitivity similar to or greater than ICA and ELISA. High reproducibility was confirmed, and no cross-reactivity or interference was detected. This assay could detect genotypes G1P[8], G2P[4], G3P[8], G4P[6], G4P[8], G8P[4], G8P[8], G9P[4], and G9P[8]. Conclusions: The AFIAS rotavirus assay showed high reproducibility, sensitivity, and specificity as well as excellent agreement with ELISA, PCR, and ICA. It detected the most common as well as unusual genotypes of rotavirus prevalent in Korea. It could be a useful onsite assay for rapid, convenient, and cost-effective detection of rotavirus infection.

Design of High-Sensitivity Compact Resonator using Interdigital-Capacitor Structure for Chipless RFID Applications (인터디지털-커패시터 구조를 이용한 Chipless RFID용 고감도 소형 공진기 설계)

  • Yeo, Junho;Lee, Jong-Ig
    • Journal of Advanced Navigation Technology
    • /
    • v.25 no.1
    • /
    • pp.90-95
    • /
    • 2021
  • In this paper, the design method for a high-sensitivity compact resonator for chipless RFID tags is proposed. Proposed high-sensitivity compact resonator uses an interdigital-capacitor structure instead of a capacitor-shaped strip structure in a conventional ELC resonator. The length of the electrode plate of the IDC structure is longer than that of the conventional capacitor-shaped structure, resulting in a larger equivalent capacitance of the resonator. This can lower the resonant peak frequency of the RCS characteristic. Two resonators with the same length of the square loop and the width of the strip are fabricated on an RF-301 substrate with a thickness of 0.8 mm. The experiment results show that the resonant peak frequency and value of the bistatic RCS for the ELC resonator were 4.305 GHz and -30.39 dBsm, whereas those of the proposed IDC resonator were 3.295 GHz and -36.91 dBsm. Therefore, the size of the resonator is reduced by 23.5% based on the measured resonant peak frequency of the RCS characteristic.

Diagnostic Significance of Combined Detection of Epstein-Barr Virus Antibodies, VCA/IgA, EA/IgA, Rta/IgG and EBNA1/IgA for Nasopharyngeal Carcinoma

  • Cai, Yong-Lin;Li, Jun;Lu, Ai-Ying;Zheng, Yu-Ming;Zhong, Wei-Ming;Wang, Wei;Gao, Jian-Quan;Zeng, Hong;Cheng, Ji-Ru;Tang, Min-Zhong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.5
    • /
    • pp.2001-2006
    • /
    • 2014
  • The objective of this study was to investigate the diagnostic significance of EBV antibody combined detection for nasopharyngeal carcinoma (NPC) in a high incidence region of southern China. Two hundred and eleven untreated NPC patients, 203 non-NPC ENT patients, and 210 healthy controls were recruited for the study. The titers of VCA/IgA and EA/IgA were assessed by immunoenzyme assay, and the levels of Rta/IgG and EBNA1/IgA were determined by enzyme-linked immunosorbent assay. The levels of VCA/IgA, EA/IgA, Rta/IgG and EBNA1/IgA demonstrated no association with gender or age (p>0.05). The receiver operating characteristic curve and the area under the curve were used to evaluate the diagnostic value. The sensitivity of VCA/IgA (98.1%) and the specificity of EA/IgA (98.5%) were the highest. When a logistic regression model was used to combine the results from multiple antibodies to increase the accuracy, the combination of VCA/IgA+Rta/IgG, whose area under the curve was 0.99, had the highest diagnostic efficiency, and its sensitivity, specificity and Youden index were 94.8%, 98.0% and 0.93 respectively. The data suggest that the combination of VCA/IgA+Rta/IgG may be most suitable for NPC serodiagnosis.