• Title/Summary/Keyword: Cross-linked polyethylene

Search Result 78, Processing Time 0.04 seconds

Development of Prefabricated Joint for 66kV Cross Linked Polyethylene Cable. (66kV XLPE Cable용 조립형 접속함의 개발)

  • Oh, E.J.;Kim, K.Y.;Lee, J.Y.;Park, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2123-2125
    • /
    • 1999
  • In recent the XLPE cable has been applied more widely because of its advantages, such as the low-cost and simple installation. For a prefabricated joint, its working time is short, its jointing procedures aγe simple, and its quality control is easy. Electrical performance targets of our developed 66kV cable accessories has been approved through the type test in accordance with IEC publication 840. This paper describes the developmental effort in terms of the design, structure and results of performance verification tests for 66kV XLPE cable system.

  • PDF

The Analysis of Discharge Distribution due to the Inner Void of Extra High Voltage Cable

  • Kim Tag-Yong;Hong Jin-Woong
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.4
    • /
    • pp.155-160
    • /
    • 2005
  • This paper addresses the discharge characteristics of cross-linked polyethylene according to void by the Weibull function. It analyzes discharge number and amount of discharge using Weibull distribution to identify the inter-relationship between partial discharge and defect. We detected a 10 second discharge. The applied voltage increased by 1 [kV] at discharge inception voltage. As a result, in a no-void specimen, the shape parameter was consistent according to the increase of voltage, whereas, in a void specimen, it increased according to the increase of voltage. As the result, the shape parameter expressed a fixed value at no-void specimen. However, in void specimen, according to increasing voltage shape parameter rapidly increases.

Life Expectancy for Power Cable Insulation(XLPE) Using Statistical Method (통계적 기법을 이용한 전력 케이블 절연층(XLPE)의 수명 예측)

  • 이승엽;조대희;이인호;박완기
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.57-61
    • /
    • 1999
  • Electrical stress makes insulating materials aged finally resulting in the dielectric failure. It becomes more and more important to recognize the degree of aging and the life time of the insulating materials since it is directly concerned with the reliability of the insulation system. In this paper, the life time of the Cross-linked Polyethylene(XLPE), the insulation layer in the 154kV-grade power cable, is expected and calculated using statistical and mathematical methods. The simulated results are compared with experimental ones and the life exponent of the material is obtained.

  • PDF

New leakage detection system for the hydraulic system of EHV underground oil-filled cables (초고압 OF 케이블 급유계통의 조기이상검지시스템)

  • Kim, Y.;Seong, J.K.;Han, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1966-1968
    • /
    • 2000
  • Globally, oil-filled paper-insulated cables and cross-linked polyethylene-insulated cables have been mainly applied for a underground power transmission line. The oil-filled cable has the hydraulic system in which insulating oil, expanded and contracted by temperature changes, is absorbed and supplied. This system enable us to detect oil leakages from the cable. But it has some problems such as difficulty in detecting minor leakages and a relatively long period of fault detecting. And so, this paper introduce a new leakage detection system, improved from the current one.

  • PDF

Development of Link Mechanism for a 154kV Cross Linked Polyethylene Cable on Bridge (교량 첨가 전력 케이블 신축균등흡수장치 개발)

  • Oh, J.O.;Ro, K.J.;Heo, H.D.;Lee, S.H.;Kim, W.B.;Kim, C.M.;Lee, T.J.;Kim, C.S.;Baek, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2081-2082
    • /
    • 2000
  • 서강대교와 같은 장경간 교량에 초고압 전력케이블을 설치하는 경우에는 교량의 큰 신축을 흡수하기 위하여 케이블을 장대옵셋으로 설치하는 것이 불가피하게 되고, 장대옵셋 케이블이 균등하게 변형할 수 있도록 신축균등흡수장치를 실증시험을 통하여 국내에서 최초로 개발하고 154kV 중여T/L 구간중 서강대교에 총12기를 설치 완료하였다. 본 고에서는 그 개요를 소개하고자 한다.

  • PDF

Development of Prefabricated Joint for 132kV Cross Linked Polyethylene Cable (132kV XLPE CABLE 조립형 접속함의 개발)

  • Kim, J.H.;Oh, E.J.;Kim, K.Y.;Park, J.K.;Jeong, Y.W.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2017-2019
    • /
    • 2000
  • In recent the XLPE cable has been applied more widely because of its advantages, such as the low-cost and simple installation. For a prefabricated joint, its working time is short, its jointing procedures are simple, and its quality control is easy. Electrical performance targets of our developed 132kV cable accessories has been approved through the type test in accordance with IEC publication 840. This paper describes the developmental effort in terms of the design, structure and results of performance verification tests for 132kV XLPE cable system.

  • PDF

PD Detection and Analysis of Electrical Treeing Progress into XLPE Insulator (XLPE 절연물내의 전기트리 진전 시 PD 검출 및 특성분석)

  • Park, Seong-Hee;Jung, Hae-Eun;Kang, Seong-Hwa;Lim, Kee-Jo
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.215-216
    • /
    • 2006
  • Solid insulation exposed to voltage is degraded by electrical tree process. And the degradation of the insulation is accelerated by voltage application. For this experimental, specimen of e1ectrical tree model is made by XLPE (cross-linked polyethylene). And the size of the specimen is $7*5*7\;mm^3$. Distance of need1e and plane is 2 mm. Voltages applied for acceleration test are 12 kV to 15 kV. And distribution characteristic of degraded stage is studied too. As a PD detecting and data process, discharge data acquire from PD detecting system (Biddle instrument). The system presents statistical distribution as phase resolved. Moreover the processing time of electrical tree is recorded to know the speed of degradation according to voltage.

  • PDF

Partial Discharge Characteristics of Ultra-High Voltage CV Cable Insulators by Electrode Shape (전극형상에 의한 초고압 CV케이블 절연체의 부분방전 특성)

  • Kim Gyun-Sig;Kim Byung-Hyun;Jeong Hyeon-Ki;Cha Kwang-Seok
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.712-717
    • /
    • 2005
  • In this thesis, it is investigated that the effect of the cross linked polyethylene(XLPE) insulator do to breakdown phenomenon by the insertion of the needle and bar electrode into XLPE which is used of electric power cable for the ultra-high voltage. The result of the partial discharge properties in the specimen showed that in case of the insertion of needle or bar electrode into XLPE, the effect of the inner discharge become large when the air void is bigger then the clearance of the electrode of the specimen. The closer the distance between the insulator and needle electrode, it takes less time to the insulation breakdown.

  • PDF

Analysis relationship with PD characteristics and occurrence of electrical treeing (전기트리 발생/열화진행과 PD와의 관계분석)

  • Jeong, Hae-Eun;Park, Seong-Hee;Lim, Kee-Joe;Kang, Seong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1476-1477
    • /
    • 2006
  • Solid insulation exposed to voltage is degraded and by electrical tree process. And the degradation of the insulation is accelerated by voltage application. For this experimental, specimen of electrical tree model is made by XLPE(cross-linked polyethylene). And the size of the specimen is 7*5*7 $mm^3$. Distance of needle and plane is 2mm. Voltage applied for acceleration test are 12kV. And distribution characteristic of degraded stage is studied too. As a PD detecting and data process, discharge data acquire from PD detecting system(Biddle instrument). Their results of PD distribution show good present and are good discriminating skill.

  • PDF

The PD Characteristics and E-field of xLPE according to the Needle Electrode of Appling Voltage (침 전극 인가전압에 따른 xLPE의 전계분포와 부분방전특성)

  • Park, Hee-Doo;Lee, Kang-Won;Lee, Hyuk-Jin;Kim, Tag-Yong;Park, Ha-Young;Hong, Jin-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1377-1378
    • /
    • 2007
  • 본 논문에서는 초고압 케이블에서 절연재료로 사용되고 있는 가교폴리에틸렌(Cross-Linked Polyethylene; xLPE)에 침전극의 기울기와 인가전압의 변화에 따른 전계분포와 방전특성을 경계요소법에 의한 3차원 시뮬레이션과 부분방전장치를 통하여 해석하여, 기울기가 $45^{\circ}$에서 전계가 집중되는 현상을 확인하였다.

  • PDF