• Title/Summary/Keyword: Cross-correlation coefficients

Search Result 345, Processing Time 0.022 seconds

Flow Noise in the Outdoor Unit of an Air-conditioner (에어컨 실외기에서의 유동소음)

  • 이승배;이재환;김휘중;최진규;진성훈;박윤서
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.594-601
    • /
    • 1997
  • Propeller fans are commonly equipped in outdoor units of air-conditioners to provide effective cooling in a dried heat exchanger. A new design technique was developed to satisfy requirements of aerodynamic and aeroacoustic performance, which employs the intersection method of two cylinders for mean camber line. Three proto-types of propeller fan including Palm-Shaped, Highly-Swept(PSHS) fan (proto 3)were not only to provide low lift forces for dipole sound, but also to reduce the organized tip vortices interacting with the fan guide causing narrow-banded rotating instabilities. Cross-correlation technique was applied to study flow noise source characteristics for three proto-type fans designed. The cross-correlations between a microphone at far field and a hot-wire sensor at near field show that flows near hub region of proto 3 fan are less organized and the flow structures especially at high flow rate coefficients for proto 3 fan are less correlated with noise generated than other proto-types fans.

  • PDF

Correlation between sagittal condylar guidance angles obtained using radiographic and protrusive occlusal record methods

  • Kwon, Oh-Kyun;Yang, Seung-Won;Kim, Jee-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.302-307
    • /
    • 2017
  • PURPOSE. This study compared the SCGAs measured in three types of radiographic images (panoramic, CBCT panoramic-section, and CBCT cross-section images) with values measured using the protrusive occlusal record. MATERIALS AND METHODS. SCGAs were measured in 20 patients on a semi-adjustable articulator using the protrusive interocclusal record. Panoramic and CBCT images were obtained. SCGAs were measured on CBCT images in panoramic and cross sections. In all of the radiographic images, SCGAs were measured using the Frankfort horizontal reference line and the mean curvature line. The most-superior and most-inferior points of the curvatures were identified to determine the mean curvature line. Each measurement was performed twice by two operators independently. The data were analyzed by the t-test, Pearson's correlation test, and Cronbach's ${\alpha}$ using SPSS (${\alpha}=.05$). RESULTS. The mean right and left SCGAs were as follows: protrusive occlusal record (30.1 and 30.2 degrees, respectively), panoramic (38.9 and 38.7 degrees), CBCT panoramic sections (35.4 and 36.8 degrees), and CBCT cross sections (35.3 and 36.1 degrees). The SCGAs differed significantly among the groups. The Pearson coefficients for the correlations with the protrusive occlusal record measurements on the left and right sides were as follows: panoramic (0.834 and 0.791, respectively), CBCT panoramic-section (0.918 and 0.837), and CBCT cross-section (0.918 and 0.845) images. CONCLUSION. Strong correlations were found between SCGAs obtained using radiographic images and the protrusive occlusal record.

The Relationship Between Activities of Daily Living and Health-Related Quality of Life in Ambulatory Stroke Patients (보행 가능한 뇌졸중 환자의 일상생활 수행능력과 건강관련 삶의 질과의 관계)

  • Won, Jong-Im
    • Physical Therapy Korea
    • /
    • v.15 no.1
    • /
    • pp.12-19
    • /
    • 2008
  • The purpose of this study was to determine the relationship between activities of daily living and health-related quality of life in ambulatory stroke patients. This was a cross-sectional survey study of 60 patients who had survived one year or more after a stroke in community. Activities of daily living were assessed using the Functional Independence Measure (FlM) and health-related quality of life using the Stroke Impact Scale (SIS). The association between FIM and SIS was examined using Pearson' s correlation. The FIM score was higher than the SIS score. Most domains of FIM exhibited a high rate (45-85%) of ceiling effects. However, only the communication and memory domain of SIS exhibited of ceiling effects. The correlation coefficients were .835 (p<.01) for FIM-motor vs. SIS-ADL, .257 (p<,05) for FIM-motor vs. SIS-communication, .596 (p<.01) for FIM-motor vs. SIS-social participation, .635 (p<.01) for FIM-cognition vs. SIS-memory, .369 (p<.01) for FIM-cognition vs. SIS-ADL, and .289 (p<.05) for FlM-cognition vs. SIS-social participation. In conclusion, the correlation between FIM-motor and SIS-social participation was higher than that of FlM-cognition and SIS-social participation. The domains of emotion and hand function of SIS showed no correlation coefficients with FIM-total. To examine the activities of daily living and the quality of life in ambulatory stroke patients in community, it is necessary to use both the FIM and SIS.

  • PDF

Investigation of surface pressures on CAARC tall building concerning effects of turbulence

  • Li, Yonggui;Yan, Jiahui;Chen, Xinzhong;Li, Qiusheng;Li, Yi
    • Wind and Structures
    • /
    • v.31 no.4
    • /
    • pp.287-298
    • /
    • 2020
  • This paper presents an experimental investigation on the surface pressures on the CAARC standard tall building model concerning the effects of freestream turbulence. Two groups of incidence turbulence are generated in the wind tunnel experiment. The first group has an approximately constant turbulence intensity of 10.3% but different turbulence integral scale varying from 0.141 m to 0.599 m or from 0.93 to 5.88 in terms of scale ratio (turbulence integral scale to building dimension). The second group presents similar turbulence integral scale but different turbulence intensity ranging from 7.2% to 13.5%. The experimental results show that the mean pressure coefficients on about half of the axial length of the side faces near the leading edge slightly decrease as the turbulence integral scale ratio that is larger than 4.25 increases, but respond markedly to the changes in turbulence intensity. The root-mean-square (RMS) and peak pressure coefficients depend on both turbulence integral scale and intensity. The RMS pressure coefficients increase with turbulence integral scale and intensity. As the turbulence integral scale increases from 0.141 m to 0.599 m, the mean peak pressure coefficient increases by 7%, 20% and 32% at most on the windward, side faces and leeward of the building model, respectively. As the turbulence intensity increases from 7.2% to 13.5%, the mean value of peak pressure coefficient increases by 47%, 69% and 23% at most on windward, side faces and leeward, respectively. The values of cross-correlations of fluctuating pressures increase as the turbulence integral scale increases, but decrease as turbulence intensity increases in most cases.

Band Estimation using Third-order Statistics and Wavelet Packet Transform (3차 통계기법과 웨이블릿 패킷 변환을 이용한 대역 추정 알고리즘)

  • 박현석;이종희;남상원
    • Proceedings of the IEEK Conference
    • /
    • 2000.09a
    • /
    • pp.923-926
    • /
    • 2000
  • In this paper we address the problem of detecting and estimating an unknown narrow band signal in a noise interference environment A new practical band estimation method, yielding good performance even in case of finite-length data, is presented. More specifically, wavelet packet transform is utilized to detect the more accurate time-variant band, then we estimate the power from wavelet filter-coefficients of the respective band. Also, third-order cumulants, and projection cross-correlation (PCC) criterion are utilized to achieve an effective SNR improvement for the time-variant band estimation. In case of time variant band estimation, the PCC method yields better performance than the correlation method.

  • PDF

A Study on Flow Characteristics and Efficiency in Guide Vane of Diffuser Pump Using PIV Measurement (PIV를 이용한 디퓨저펌프 정익에서의 성능과 유동특성에 관한 연구)

  • 김정환;김범석;김진구;함승덕;이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.633-640
    • /
    • 2003
  • The present experimental study is focused on the application of multi-point simultaneous measurement by PIV(Particle Image Velocimetry) to guide vane region within diffuser pump. Various different kinds of rotational velocity were selected as experimental condition. Optimized cross correlation Identification to obtain velocity vectors is implemented with direct calculation of correlation coefficients. Fine optical setup concerned with PIV performance is arranged for the accurate PIV measurement of high-speed complex flow. Variable flow pattern are represented quantitatively at the stator region.

Measurement of the Velocity field of Rotor-Stator in a Centrifugal Turbine Pump by Using PIV (PIV를 이용한 터빈펌프의 동${\cdot}$정익 속도장 계측)

  • Im, Yu-Cheong;Seo, Min-Sik;Lee, Young-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 1998.12a
    • /
    • pp.11-18
    • /
    • 1998
  • The present experimental study is focused on the application of multi-point simultaneous measurement by PIV(Particle Image Velocimetry) to rotor-stator region within centrifugal turbine pump. Six different kinds of rpm(120, 500, 1000, 1500, 2000 and 2500) are selected as experimental condition. Optimized cross correlation identification to obtain velocity vectors is implemented by direct calculation of correlation coefficients. Fine optical setup deeply concerned with PIV performance is arranged for accurate PIV measurement of high-speed complex flow. The instantaneous and time-mean velocity distribution and velocity profile are represented quantitatively at the rotor and stator region.

  • PDF

A Study on Flow and Efficiency Characteristics in Guide Vane of Diffuser Pump Using PIV Measurement (PIV 계측을 이용한 디퓨져펌프의 정익에서의 성능과 유동특성에 관한 연구)

  • Kim, J. H.;Choi, M. S.;Kim, J. G.;Lee, Young-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.29-35
    • /
    • 2000
  • The present experimental study is focused on the application of multi-point simultaneous measurement by PIV(Particle Image Velocimetry) to guide vane region within diffuser pump. Various different kinds of rotational velocity were selected as experimental condition. Optimized cross correlation identification to obtain velocity vectors is implemented with direct calculation of correlation coefficients. Fine optical setup concerned with PIV performance is arranged for the accurate PIV measurement of high-speed complex flow. Variable flow pattern are represented quantitatively at the stator region.

  • PDF

Flow Characteristics of Guide Vane of Diffuser Pump by PIV Measurement (PIV계측에 의한 디퓨져펌프 안내깃에서의 유동특성)

  • Kim, J.H.;Choi, J.W.;Kim, M.Y.;Lee, H.;Lee, Young-Ho
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.391-396
    • /
    • 2000
  • The present experimental study is focused on the application of multi-point simultaneous measurement by PIV(Particle Image Velocimetry) to guide vane region within a diffuser pump. Various different kinds of clearance were selected as experimental conditions. Optimized cross correlation identification to obtain velocity vectors was implemented with direct calculation of correlation coefficients. Fine optical setup important in PIV performance is arranged for the accurate PIV measurement of high-speed complex flow. Various flow patterns are represented quantitatively at the stator passages.

  • PDF

Measurement of Flow Field in a Domestic Boiler Circulation Pump by PIV (PIV에 의한 가정용보일러용 순환펌프의 내부 유동장 계측)

  • Im, Y.C.;Kim, J.H.;Choi, M.S.;Lee, Y.H.
    • Journal of Power System Engineering
    • /
    • v.3 no.2
    • /
    • pp.13-19
    • /
    • 1999
  • The purpose of the present experimental study is to apply multi-point simultaneous measurement by PIV(Particle Image Velocimetry) to high-speed flow region within a domestic boiler circulation pump. Two different kinds of flow rate($27{\ell}/min,\;19{\ell}/min$)are selected as experimental condition. A volute casing and Impeller made of transparent Polycarbonate were made for the easy access of the illumination laser via fiber optical line and cylinder lens assembly to the measuring region. A CCD camera is syncronized with AOM to acquire clear original particle images. Optimized cross correlation identification to obtain velocity vectors is implemented by direct calculation of correlation coefficients. The instantaneous and time-mean velocity distribution, velocity profile and kinetic energy are represented quantitatively at the full-scale region for the deeper understanding of the unsteady flow characteristics in a commercial circulation pump.

  • PDF