• 제목/요약/키워드: Cross Mode

Search Result 716, Processing Time 0.025 seconds

Comparative Studies of Pulsatile and Nonpulsatile Blood Flow during Cardiopulmonary Bypass (박동류 및 비박동류에 의한 체외순환의 비교)

  • Sun, Kyung;Baek, Kwang-Je;Kim, Yo-Han;Kim, Chang-Young;Kim, Kwang-Taek;Kim, Hark-Jei;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.18 no.2
    • /
    • pp.182-192
    • /
    • 1985
  • [here are so many reports that pulsatile blood flow provides physiologic organ perfusions during cardiopulmonary bypass. So, we compared the recent 30 cases undergoing cardiac surgery by Cobe-Stckert pulsatile roller pump with another 30 cases by Polystan nonpulsatile roller pump. Pulsatile flow was applied during aortic-cross clamping period when synchronized to internal EKG simulator, and perfusion mode was changed to continuous nonpulsatile flow after declamping of aorta. Age, sex, weight, and disease entities were comparable and operative techniques were similar between two groups. 1. There were no differences in average ACC time, ECC time, and Operation time. 2. Postoperative artificial respiration time was 6hrs 30mins in nonpulsatile group and 4hrs 48mins in pulsatile group, and detubation time after ventilator weaning was 2hrs 44mins in nonpulsatile group and 1hrs 43mins in pulsatile group. 3. Average pulse pressure was 8mmHg in nonpulsatile group and 55mmHg in pulsatile group, and a mean arterial pressure was 66.0mmHg in nonpulsatile group and 60.7mmHg in pulsatile group. 4. Mean urine-output during ACC;ECC period was 9.717.3;9.913.2ml/kg/hr in nonpulsatile group and 14.215.0;15.817.5 in pulsatile group [p<0, 05], and thereafter progressive decrease of differences in urine output between two groups until POD 2, and lesser amounts of diuretics was needed in pulsatile group during same postoperative period. Serum BUN/Cr level showed no specific difference and urine concentration power was well preserved in both groups. 5. Plasma proteins and other Enzymes showed no differences between two groups, but serum GOT/GPT level was higher in nonpulsatile group till POD 2. 6. Serum Electrolytes showed no differences between two groups. 7. WBC, RBC, Platelet counts, Hgb and Hct were not different and Coagulogram was well preserved in both groups. 8. Plasma free Hgb level was 7.09mg% in pulsatile group compared with 3.48mg% in pulsatile group on POD 1 but was normalized on POD 2. Gross hemoglobinuria after ECC was noted in 6 cases [20%] of pulsatile group and 4 cases [13%] of nonpulsatile group. 9. In both groups, most patients were included in NYHA class III to IV [28 cases;93% in nonpulsatile group, 22 cases;73% in pulsatile group] preoperatively, and well improved to class I to 11[22 cases; 73% in nonpulsatile group, 30 cases; 100% in pulsatile group] postoperatively. There were 7 operative mortalities in nonpulsatile group only, which were 5 cases of TOF with hepatic failure, 1 case of multiple VSDs with low out-put syndrome, and 1 case of mitral valvular heart disease with cardiomyopathy. We concluded that the new, commercially available Cobe-Stckert pulsatile roller pump device was safe, simple, and reliable.

  • PDF

Evaluation of Early Generations of Crosses for Incorporation of Resistance to Phytophthora Blight into Sweet Pepper (감미종(甘味種)고추에 역병저항성(疫病抵抗性)을 도입(導入)하기 위한 교잡(交雜) 초기세대(初期世代) 검정(檢定))

  • Jeong, Ho Jeong;Kim, Byung Soo;Shon, Eun Young
    • Current Research on Agriculture and Life Sciences
    • /
    • v.12
    • /
    • pp.29-34
    • /
    • 1994
  • A leading sweet pepper cultivar, Keystone Resistant Giant #3, was crossed with a line with resistance to Phytophthora capsici, PI201232, for incorporation of the resistance and to study the inheritance of resistance to the disease. Seedlings of parents, $F_1$, $F_2$ and backcross populations of a cross between Keystone Resistant Giant #3 and PI201232 were inoculated with zoospore suspension of P. capsici at 36 days after seeding. Most of the $F_1$ seedlings survied the inoculation and this suggested that resistance is dominant over susceptibility. The number of survived plants in $F_2$ population was, however, much less than the killed. All the plants in a backcross to Keystone Resistant Giant #3 were killed. Therefore, the observed numbers did not fit the expected ratio for segregation of one or two dominant alleles as previously reported. The resistance to P. capsici appeared to be inherited in a quantitative mode in evaluation of root rot. Resistant individuals in $F_2$ population were selected and a breeding program for incorporation of the resistance to P. capsici by backcross method is continued.

  • PDF

Evaluation of Early Generation of Crosses for Incorporation of Resistance to Bacterial Spot into Sweet Pepper (감미종(甘味種) 고추에 더뎅이병(病) 저항성(抵抗性)을 도입(導入)하기 위한 교잡(交雜) 초기세대(初期世代) 검정(檢定))

  • Jeong, Ho Jeong;Kim, Byung Soo;Shon, Eun Young
    • Current Research on Agriculture and Life Sciences
    • /
    • v.12
    • /
    • pp.23-28
    • /
    • 1994
  • A leading sweet pepper cultivar, Keystone Resistant Giant #3, was crossed with a line with resistance to Xanthomonas campestris pv. vesicatoria, PI271322, for incorporation of the resistance and to study the inheritance of resistance to the disease. Seedlings of parents, $F_1$, $F_2$ and backcross populations of a cross between Keystone Resistant Giant #3 and PI271322 were inoculated with race 1 and race 3 of Xanthamonas campestris pv. vesicatoria by infiltrating bacterial suspension into abaxial side of leaves. PI271322 was carrying a gene ($Bs_3$) for hypersensitive resistance to race 1 of X. c. pv. vesicatoria and also a component of non-hypersensitive resistance to race 3 inheriting in a quantitative mode. Correlation coefficient between disease indices to race 1 and race 3 of non-hypersensitive plants in $F_2$ population was highly significant, thus indicating that a component of non-hypersensitive general resistance in PI271322 acted consistently to both races. Individual plants with resistance to both race 1 and race 3 of X. c. pv. vesicatoria were selected and a breeding program for incorporation of the resistance is continued.

  • PDF

Characteristics of Microwave Air Plasma With a Wide Range of Operating Pressures (운전압력 변화에 따른 마이크로파 공기 플라즈마의 특성연구)

  • 조정현;장봉철;박봉경;김윤환;정용호;김곤호
    • Journal of the Korean Vacuum Society
    • /
    • v.11 no.1
    • /
    • pp.68-75
    • /
    • 2002
  • It is observed the characteristic of the microwave air plasma in the wide range of the operating pressure, 1 mTorr ~ 760 Torr. The microwave air plasma was generated by an AC-type microwave source manufactured with a magnetron taken from a commertial microwave oven and the input power was fixed at 370 W. Characteristics of the plasmas were observed by an injection Langmuir probe and an OES(Optical Emission Spectroscopy). The breakdown electric field is drastically changed at 500 mTorr. For < 500 mTorr, the ratio of the breakdown electric field and the pressure decreased inversely to the pressure, $5.7\times10^4$V/m-Torr.However, the ratio increased linearly as 43 V/m-Torr for the operating pressure, > 500 mTorr. The minimum breakdown electric field was observed about 12. kV/m at 500 mTorr. It corresponds that the input frequency equals to the collision frequency. The effective collision cross section of the air at this pressure was calculated as $9.23\times10^{-l6}\textrm{cm}^2$.The results of the OES measurement revealed that the main ions were composed of the oxygen, argon, and nitrogen for > 500 mTorr. In contrast, only oxygen and argon ions were dominated for < 500 mTorr. ion temperature of oxygen (O(II)) in the air was decreased from about 1.2 eV to 0.5 eV as the pressure increased. Langmuir probe data shows that the plasma density for < 500 mTorr was higher that for > 500 mTorr.

MICRO-TENSILE BONDING STRENGTH OF REGIONAL PRIMARY MOLAR DENTIN (유구치 상아질의 각 부위에 적용된 수종의 복합레진 접착제의 미세인장접착강도에 관한 연구)

  • You, Jung-Eun;Choi, Yeong-Chul;Chio, Sung-Chul;Park, Jae-Hong
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.3
    • /
    • pp.348-357
    • /
    • 2009
  • The purpose of this study was to evaluate the micro-tensile bond strength (${\mu}TBS$) of four luting resin to regional dentin of human primary teeth. Dentin from non-carious primary molars were prepared from different regions (s, superficial dentin; d, deep dentin; c, cervical dentin), and divided into groups based on anatomical locations and types of luting resins (Scotchbond Multi-purpose : SB ; One-Step : OS ; AdheSE Bond : ASE ; G-Bond : GB) : SB-s, SB-d, SB-c; OS-s, OS-d, OS-c; ASE-s, ASE-d, ASE-c ; GB-s, GB-d, GB-c. Luting resins were used according to the manufacturers' instructions, to bond $Light-Core^{TM}$ Core Build-Up Composite) to the exposed dentin specimens in the light-curing mode. After storage for 1 day, ${\mu}TBS$ was tested at a cross-head speed of 1 mm/min. Data were analyzed with T-test and two-way ANOVA. The bonding interface and fractography analyses were performed with SEM. The results were as follows : 1. ${\mu}TBS$ to superficial dentin was significantly higher than to deep dentin for SB(p<0.05). But there were no significant differences in regional ${\mu}TBS$ among OS, ASE, GB(p>0.05). 2. There were no significant differences in ${\mu}TBS$ to superficial dentin among each groups. But, in deep dentin, ${\mu}TBS$ of SB-d was significantly lower than those of OS-d, ASE-d, and GB-d(p<0.05). ${\mu}TBS$ of OS-d was significantly higher than those of GB-d(p<0.05), but there were no significant differences in ${\mu}TBS$ of ASEd. There were no significant differences among ${\mu}TBS$ of ASE-d, OS-d, and GB-d.

  • PDF

Association of Blood Pressure Levels with Carotid Intima-Media Thickness and Plaques (혈압 수준과 경동맥 내중막 두께 및 동맥경화반의 관련성)

  • Lee, Young-Hoon;Kweon, Sun-Seog;Choi, Jin-Su;Rhee, Jung-Ae;Choi, Sung-Woo;Ryu, So-Yeon;Shin, Min-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.42 no.5
    • /
    • pp.298-304
    • /
    • 2009
  • Objectives : The aim of this study was to investigate the association of blood pressure levels with the common carotid artery intima-media thickness (CCA-IMT) and carotid plaques. Methods : Data were obtained from 2,635 subjects, aged 50 years and over, who participated in the Community Health Survey (a population-based, cross-sectional study) in Dong-gu, Gwangju city between 2007 and 2008. Participants were categorized into three groups according to blood pressure levels; normotensives (<120/80 mmHg), prehypertensives (120-139/80-89 mmHg), and hypertensives ($\geq$140/90 mmHg). Prehypertensives were further categorized as low prehypertensives (120-129/80-84 mmHg) and high prehypertensives (130-139/85-89 mmHg). Carotid intima-media thickness and plaques were evaluated with a high-resolution B-mode ultrasound. Statistical analyses were performed using chi-square test, ANOVA, and multiple logistic regression. Results : Prehypertensives had significantly greater maximal CCA-IMT values than normotensives, with a multivariate adjusted odds ratio of 1.78 (95% CI=1.36-2.32) for abnormal CCA-IMT (maximal CCA-IMT$\geq$1.0 mm), and 1.45 (95% CI=1.19-1.77) for carotid plaques. The multivariate adjusted odds ratio of low prehypertensives was 1.64 (95% CI=1.21-2.21) for abnormal CCA-IMT, and 1.30 (95% CI=1.04-1.63) for carotid plaques compared with normotensives. Subject with hypertension had higher frequency of abnormal CCA-IMT (odds ratio, 2.18; 95% CI=1.49-3.18), and carotid plaques (odds ratio, 1.98; 95% CI=1.46-2.67) compared with normotensives after adjustment for other cardiovascular risk factors. Conclusions : Our results indicate that there is a significant increase in the prevalence of carotid atherosclerosis in subjects with prehypertension (even in low prehypertensives) compared with normotensive subjects. Further studies are required to confirm the benefits and role of carotid ultrasonography in persons with prehypertension.

Resonance Frequency Analysis of A Baseball Bat by Impact Angle (가진 각도에 따른 야구배트의 공진주파수 분석)

  • Park, Sun-Hyang;Chung, Woo-Yang;Jung, Hwan-Hee;Lee, Sang-Joon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.6
    • /
    • pp.777-783
    • /
    • 2015
  • Wood is an anisotropic material that shows the changes in hardness, quality and dimensions depending on the types of cells on three cross sections, size, array and so on. It can also be used in different ways according to its use, which requires a meticulous research, in order to maximize the utilization by understanding the nature and use; and by clarifying the theory and technologies. The research on relationship among wood's physical properties, density, and elasticity of modulus have been studied in Korea and abroad, but those studies were based on correlation gained through standardized specimen. Rather, the study on complete product is rare. Moreover, the previous reports are mostly concentrating on vibration mode and batting, though the wood's physical properties as a material have not been in the main focus. Therefore, this study will carried out for analyzing MOE through figuring material property out and comparing frequency adapting to the Canadian HardMaple bat. For comparison of material properties, we studied the annual ring and density of the bat; calculated the MOE with resonance frequency and formula (ASTM C1259); and verified the repulsive force of this material. As a result, the relevance of the resonance frequency and annual ring is weak, and in comparison in the grain direction in wood, the MOE value is higher when the grain direction in wood is excited horizontally than when is excited vertically, because the material is repulsive when grain direction is horizontal.

Reliability of Sn-Ag-Cu Solder Joint on ENEPIG Surface Finish: 1. Effects of thickness and roughness of electroless Ni-P deposit (ENEPIG 표면처리에서의 Sn-Ag-Cu 솔더조인트 신뢰성: 1. 무전해 Ni-P도금의 두께와 표면거칠기의 영향)

  • Huh, Seok-Hwan;Lee, Ji-Hye;Ham, Suk-Jin
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.3
    • /
    • pp.43-50
    • /
    • 2014
  • By the trends of electronic package to be smaller, thinner and more integrative, the reliability of interconnection between Si chip and printed circuit board is required. This paper reports on a study of high speed shear energy of Sn-4.0wt%Ag-0.5wt%Cu (SAC405) solder joints with different the thicknesses of electroless Ni-P deposit. A high speed shear testing of solder joints was conducted to find a relationship between the thickness of Ni-P deposit and the brittle fracture in electroless Ni-P deposit/SAC405 solder. A focused ion beam (FIB) was used to polish the cross sections to reveal details of the microstructure of the fractured pad surface with and without $HNO_3$ vapor treatment. The high speed shear energy of SAC405 solder joint with $1{\mu}m$ Ni-P deposit was found to be lower without $HNO_3$ vapor, compared to those of over $3{\mu}m$ Ni-P deposit. This could be due to the edge of solder resist in $1{\mu}m$ Ni-P deposit, which provides a fracture location for the weakened shear energy of solder joints and brittle fracture in high speed shear test. With $HNO_3$ vapor, the brittle fracture mode in high speed shear test decreased with increasing the thickness of Ni-P deposit. Then the roughness (Ra) of Ni-P deposits decreased with increasing its thickness. Thus, this gives the evidence that the decrease in roughness of Ni-P deposit for Eelectroless Ni/ Electroless Pd/ Immersion Au (ENEPIG) surface play a critical role for improving the robustness of SAC405 solder joint.

Patient-Specific Quality Assurance in a Multileaf Collimator-Based CyberKnife System Using the Planar Ion Chamber Array

  • Yoon, Jeongmin;Lee, Eungman;Park, Kwangwoo;Kim, Jin Sung;Kim, Yong Bae;Lee, Ho
    • Progress in Medical Physics
    • /
    • v.29 no.2
    • /
    • pp.59-65
    • /
    • 2018
  • This paper describes the clinical use of the dose verification of multileaf collimator (MLC)-based CyberKnife plans by combining the Octavius 1000SRS detector and water-equivalent RW3 slab phantom. The slab phantom consists of 14 plates, each with a thickness of 10 mm. One plate was modified to support tracking by inserting 14 custom-made fiducials on surface holes positioned at the outer region of $10{\times}10cm^2$. The fiducial-inserted plate was placed on the 1000SRS detector and three plates were additionally stacked up to build the reference depth. Below the detector, 10 plates were placed to avoid longer delivery times caused by proximity detection program alerts. The cross-calibration factor prior to phantom delivery was obtained by performing with 200 monitor units (MU) on the field size of $95{\times}92.5mm^2$. After irradiation, the measured dose distribution of the coronal plane was compared with the dose distribution calculated by the MultiPlan treatment planning system. The results were assessed by comparing the absolute dose at the center point of 1000SRS and the 3-D Gamma (${\gamma}$) index using 220 patient-specific quality assurance (QA). The discrepancy between measured and calculated doses at the center point of 1000SRS detector ranged from -3.9% to 8.2%. In the dosimetric comparison using 3-D ${\gamma}$-function (3%/3 mm criteria), the mean passing rates with ${\gamma}$-parameter ${\leq}1$ were $97.4%{\pm}2.4%$. The combination of the 1000SRS detector and RW3 slab phantom can be utilized for dosimetry validation of patient-specific QA in the CyberKnife MLC system, which made it possible to measure absolute dose distributions regardless of tracking mode.

Flexural Strength Evaluation of Steel Plate-Concrete Composite Beam using Bolted (절곡 강판을 볼트로 체결한 강판-콘크리트 합성보의 휨강도 평가)

  • Han, Myoung-Hwan;Choi, Byong-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.126-136
    • /
    • 2018
  • A steel-plate concrete composite beam is composed of a steel plate, concrete and shear connector to combine inhomogeneous two materials. The steel plate is assembled by welding an existing composite beam. In this study, new steel-plate concrete composite beam, called a SPC Beam, was developed to reduce the shear connector and improve the workability. The SPC Beam was composed of folding steel plates and concrete, without a shear connector. The folding steel plate was assembled using high strength bolt instead of welding. To improve the workability in field construction, a hat-shaped Cap was attached to the junction with a slab. Monotonic load testing under two points was conducted under displacement control mode. The flexural strength of the specimen for positive moment and negative moment was calculated using the plastic stress distribution method. The test results showed that the flexural strength of the new SPC Beam had 80% of the strength of a complete composite beam. In addition, increasing the composite ratio was possible through clearance controls of the cap. In this study, the performance of the SPC Beam was verified through additional experiments and analyses with the cross-sectional shape and cap as variables, because the representative shape in the positive negative moment region is targeted.