• Title/Summary/Keyword: Cross Mode

검색결과 716건 처리시간 0.026초

슬라이딩모드 제어 기법을 이용한 구조-제어 시스템의 통합 최적 설계 (Combined Optimal Design of Structure-Control Systems by Sliding Mode Control)

  • 박중현
    • 한국정밀공학회지
    • /
    • 제19권10호
    • /
    • pp.45-51
    • /
    • 2002
  • To achieve the lightweight and robust design of a structure, it is requested to design a structure and its control system simultaneously, which is called as the combined optimal design. A constant-cross-sectional area cantilever beam was chosen as an example for the applying the optimum design method. An initial load and a time varying disturbance were applied at the free end of the beam. Sliding mode control was selected due to its insensitiveness to the disturbance compared with other modes. It is known that the sliding mode control is robust to the disturbance and the uncertainty only if a matching condition is met, after giving a switching hyper plane. In this study, the optimum method was used for the design of the switching hyper plane and the objective function of the optimum switching hyper plane was assumed to be the objective one of the control system. The total weight of the structure was treated as a constraint and the cross sectional areas of the beam were considered as design variables, which means a nonlinear programming problem. The sequential linear programming method was applied to solve it. As a result of the optimum design, the effect of attenuating vibrations has been improved obviously. Moreover, lightweight design of the structure became possible from the relationship of the weight of the structure and the control objective function.

역세 배출수 처리를 위한 관형막의 전량여과 운전 적용에 대한 연구 (A Study about Applicability of Treatment for Backwash Water Using Tubular Membrane System with Dead-End Operation Mode)

  • 엄정열;김관엽;김영훈;송준섭;김형수;한명애;양형석
    • 상하수도학회지
    • /
    • 제22권4호
    • /
    • pp.437-444
    • /
    • 2008
  • Many other countries have investigated the new backwash water treatment process to save the existing water resource. There are various methods for reusing backwash water, but the membrane system has received the most interest for its efficiency. The objective of this study was to certify the application of membrane filtration system for the backwash water treatment. The experiment equipment was composed of Lab scale tubular membrane filtration system. Generally, cross-flow operation mode is used in the tubular membrane system but cross-flow operation mode demands high electric cost mainly for the pump energy. So to cut off electric cost, dead-end operation mode was used in this experiment. Filtration and bleed operation cycle was used in this membrane system. Backwash water was concentrated during the filtration process and when backwash water reached our target suspended solid concentration, it was discharged from this system. For efficient operation of filtration and bleed, mathematical matrix was drawn up and with this matrix we could simulate various sets of filtration and bleed time.

임계 경사각을 고려한 기계적 체결부 균열의 혼합모드 피로균열성장 거동 (Mixed-Mode Fatigue Crack Growth Behavior of Cracks in Mechanical Joints Considering Critical Inclined Angle)

  • 허성필;양원호;정기현;류명해
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.187-192
    • /
    • 2001
  • Cracks in mechanical joints is generally under mixed-mode and there is the critical inclined angle at which mode I stress intensity factor becomes maximum. In order to evaluate the fatigue life of cracks in mechanical joints, horizontal crack normal to the applied load and located on minimum cross section is major concern but critical inclined crack must also be considered. In this paper mixed-mode fatigue crack growth test is performed for horizontal crack and critical inclined crack in mechanical joints. Fatigue crack growth path is predicted by maximum tangential stress criterion using mode I and mode II stress intensity factors obtained from weight function method, and fatigue crack growth rates of horizontal and inclined crack are compared.

  • PDF

영상-모드 및 Galerkin법을 이용한 전송선 문제 해석 (An Analysis of Transmission Line Structure by Combining Image Mode and Galerkin Methods)

  • 신규현;정현교;한송엽
    • 대한전기학회논문지
    • /
    • 제40권12호
    • /
    • pp.1296-1301
    • /
    • 1991
  • This paper presents a hybrid image mode Galerkin method for the analysis of the transmission line structures suspended between infinite parallel ground planes. A Green's function that consists of numerically accelerated image mode terms is developed, which is used in boundary integral equation. Transmission lines of arbitrary cross section are analyzed using Galerkin's method. Two kinds of configurations of transmission lines are studied in sample problems.

  • PDF

가압경수로용 환형 실린더 연료봉의 단면치수와 스팬길이에 따른 진동특성해석 (Vibration Characteristic Analysis of an Annular Cylindrical PWR Fuel Rod according to the Cross-sectional Dimensions and the Span Length)

  • 이강희;김재용;이영호;윤경호;김형규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.197-201
    • /
    • 2007
  • Vibration characteristics of an annular cylindrical fuel rod, which was proposed as a candidate design of fuel's cross section for the ultra-high burnup nuclear fuel, according to the cross-sectional dimensions and the number of supports or the span length were analytically studied. Finite element(FE) modeling for the annular cross sectional fuel was based on the methodology, that have been proven by the test verification, for the conventional PWR nuclear fuel rod. A commercial FEA code, ABAQUS, was used for the FE modeling and analysis. A planar beam element (B21) that uses a linear interpolation was used for the fuel rod and a linear spring element for the spring and dimple of the SG. Natural frequencies and mode shape were calculated according to the preliminary design candidates for the fuel's cross sectional dimension and the number of span. From the analysis results, the design scheme of the annular fuel compatible to the present PWR nuclear reactor core was discussed in terms of the number of supports and fuel's cross section.

  • PDF

Analysis of cross-talk effects in volume holographic interconnections using perturbative integral expansion method

  • Jin, Sang-Kyu
    • Journal of the Optical Society of Korea
    • /
    • 제2권2호
    • /
    • pp.58-63
    • /
    • 1998
  • Cross-talk effects in high-density volume holographic interconnections are investigated using perturbative iteration method of the integral form of Maxwell's wave equation. In this method, the paraxial approximation and negligence of backward scattering introduced in conventional coupled mode theory is not assumed. Interaction geometries consisting of non-coplanar light waves and multiple index gratings are studied. Arbitrary light polarization is considered. Systematic analysis of cross-talk effects due to multiple index gratings is performed in increasing level of diffraction orders corresponding to successive iterations. Some numerical examples are given for first and third order diffraction.

Interference Alignment Based Transceiver Design in OSG mode of HetNets

  • Niu, Qin;Zeng, Zhimin;Zhang, Tiankui;Hu, Zhirui
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제9권6호
    • /
    • pp.2014-2034
    • /
    • 2015
  • This paper focuses on solving co-channel interference (CCI) issues arising in the open subscriber group (OSG) mode of heterogeneous networks (HetNets). Considering a general framework consisting of arbitrary number of picocells within a macro cell, where the inter-user interference (IUI) is the main CCI to macro user equipments (UEs), while the the inter-cell interference (ICI) is the major CCI to pico UEs. In this paper, three IA based transceiver design schemes are proposed. For macro cell, we uniformly use block diagonalization (BD) scheme to eliminate the IUI. And for picocells, three IA schemes are proposed to mitigate the ICI. The first scheme, named as zero forcing IA (ZF-IA) scheme, aligns the inter picocell interference onto an arbitrary sub-space of the cross-tier interference using ZF scheme. Considering the channel state information (CSI) of the desired channel of pico UEs, the second scheme, named as optimal desired sub-channel selected IA (ODC-IA) scheme, aligns the inter picocell interference onto a certain sub-space of the cross-tier interference, which guarantees the largest channel gain of the desired signal of pico UEs. The third IA scheme, named as maximum cross-tier interference selected IA (MI-IA) scheme, is designed for the system with less receive antennas. The inter picocell interference is aligned onto the space of the strongest cross-tier interference and only the interference on this space is nullified. The complexity analysis and simulations show that the proposed transceiver design schemes outperform the existing IA schemes in the OSG mode of HetNets, and the MI-IA scheme reduces the requirement of the receive antennas number with lower complexity.

Analysis of concrete-filled steel tubular columns with "T" shaped cross section (CFTTS)

  • Wang, Qin-Ting;Chang, Xu
    • Steel and Composite Structures
    • /
    • 제15권1호
    • /
    • pp.41-55
    • /
    • 2013
  • This paper presents a numerical study of axially loaded concrete-filled steel tubular columns with "T" shaped cross section (CFTTS) based on the ABAQUS standard solver. Two types of columns with "T" shaped cross section, the common concrete-filled steel tubular columns with "T" shaped cross section (CCFTTS) and the double concrete-filled steel tubular columns with "T" shaped cross section (DCFTTS), are discussed. The failure modes, confining effects and load-displacement curves are analyzed. The numerical results indicate that both have the similar failure mode that the steel tubes are only outward buckling on all columns' faces. It is found that DCFTTS columns have higher axial capacities than CCFTTS ones duo to the steel tube of DCFTTS columns can plays more significant confining effect on concrete. A parametric study, including influence of tube thickness, concrete strength and friction coefficient of tube-concrete interface on the axial capacities is also carried out. Simplified formulae were also proposed based on this study.

임의의 모드를 가지는 모드적합법을 사용한 원형 단순확장관의 음향해석 (Acoustic Analysis of Simple Expansion Chamber Using Mode Matching Method with Arbitrary Number of Modes)

  • 김봉준;정의봉;이정환
    • 한국음향학회지
    • /
    • 제19권1호
    • /
    • pp.54-60
    • /
    • 2000
  • 고차모드를 고려하여 단순확장관을 해석한 많은 선행연구가 이루어 졌고, 이러한 연구는 모드적합법, 속도포텐셜법, 유한요소법으로 분류할 수 있다. 이들 중 모드적합법은 동심관형확장관을 해석하는 데 유용하다. 일반적으로 입·출구의 단면적이 중간확장관의 단면적보다 작으므로 입·출구에 고려하는 고차모드의 개수는 중간확장관에 고려하는 고차모드의 개수보다 작을 수 있다. 그러나 모드적합법은 입·출구와 중간확장관에 같은 개수의 고차모드를 사용하여야 한다. 그래서 입·출구에 불필요한 고차모드를 포함하게 되어 계산시간을 늘이는 결과를 초래한다. 본 논문에서는 입구, 중간확장관 그리고 출구에 각각 임의의 고차모드의 개수를 선택할 수 있는 새로운 방법을 제시하였다. 그리고 이 방법의 정확성을 검증하기 위하여 전통적인 모드적합법, 유한요소법과 비교하였고, 이 새로운 방법이 계산시간을 줄일 수 있다는 것을 보였다.

  • PDF

이피디엠/폴리프로필렌 열가소성 경화물에서 오일의 블렌드 방식이 경화물의 물성에 미치는 영향 (Influence of Blend Mode of Extender Oil on the Properties of EPDM/PP-Based Thermoplastic Vulcanizates)

  • 나성수;송기찬;김수경
    • Elastomers and Composites
    • /
    • 제44권3호
    • /
    • pp.315-322
    • /
    • 2009
  • 이피디엠/폴리프로필렌 열가소성 경화물을 오일의 배합 순서를 달리한 두 가지 방식(오일 블렌드 후 가교방식과 가교 후 오일 블렌드 방식)으로 제조하여 가교도(겔분율), 경도, 인장강도, 신율, 용융흐름지수 등을 조사, 오일의 블렌드 방식이 열가소성 경화물의 물성에 미치는 영향을 알아보았다. 오일의 블렌드 방식에 따른 두 경화물의 가교도와 기계적 물성의 차는 크지 않았으나, 가공성에 있어서는 가교 후 오일 블렌드 방식으로 제조한 경화물의 용융흐름지수가 현저히 증가한 결과를 보였다.