AIP-TiN/WC-Co계에서 WC입자크기와 Co함량이 밀착력에 미치는 영향 (Effect of the WC particle size and Co content on the adhesion property between AIP-TiN coating and WC-Co substrate)

  • 한대석;류정민;권식철;김광호
    • 한국표면공학회지
    • /
    • 제35권3호
    • /
    • pp.165-171
    • /
    • 2002
  • TiN coating were deposited onto different WC-Co substrates using arc ion plating (AIP) technique. The structure and morphology for the deposited coating were characterized by x-ray diffraction (XRD) and scanning electron microscopy (SEM). The adhesion behavior of the deposited TiN coating was investigated with a conventional scratch test. Effects of WC particle size and Co content on the adhesion strength between the deposited TiN coating and substrate were studied. During the scratch test, the value of critical load was dependent of WC particle size and Co content on substrate. As the WC particle size and Co content on substrate decreased, the critical load increased. The highest critical load, approximately 110N, was obtained at WC particle size of 1$\mu\textrm{m}$ and Co content of 10wt.%.

침지시험법 및 전기화학적 분극법에 의한 2205 이상 스테인리스강의 임계공식온도 측정 비교 (Critical Pitting Temperature of 2205 Duplex Stainless Steels Using Immersion and Electrochemical Polarization Test Methods)

  • 신재호;이재봉
    • 한국표면공학회지
    • /
    • 제39권1호
    • /
    • pp.18-24
    • /
    • 2006
  • Although stainless steels have the excellent corrosion resistance by passive film, they are susceptible to pitting corrosion in the environment containing halogen elements such as chloride ions. The resistance to pitting corrosion can be evaluated by measuring the critical pitting temperature (CPT). CPT values can be obtained using immersion, potentiodynamic and potentiostatic polarization test methods. Results on duplex 2205 stainless steels showed that CPT values were measured as $50^{\circ}C,\;55^{\circ}C\;and\;61^{\circ}C$, respectively for immersion, potentiodynamic and potentiostatic polarization test methods, depending upon the different test methods, even though the difference between CPT values are not much.

임계평면법을 이용한 거친 표면의 구름접촉시 피로균열 시작수명 (The Fatigue Crack Initiation Life under the Rolling Contact of Rough Surfaces using Critical Plane Approach)

  • 설광조;김태완;조용주
    • Tribology and Lubricants
    • /
    • 제19권1호
    • /
    • pp.26-30
    • /
    • 2003
  • The stresses of surface and substrate under the rough surface contact are irregular. Using rainflow counting method for irregular stresses, the fatigue surface crack initiation lift was calculated. With the surface generated by computer, this paper figures out the random load generated by contacting to the rough surface, analyzes the stress of its subsurface, and calculates the fatigue crack initiation life of the rough surface fatigue theory.

Critical face pressure and backfill pressure in shield TBM tunneling on soft ground

  • Kim, Kiseok;Oh, Juyoung;Lee, Hyobum;Kim, Dongku;Choi, Hangseok
    • Geomechanics and Engineering
    • /
    • 제15권3호
    • /
    • pp.823-831
    • /
    • 2018
  • The most important issue during shield TBM tunneling in soft ground formations is to appropriately control ground surface settlement. Among various operational conditions in shield TBM tunneling, the face pressure and backfill pressure should be the most important and immediate measure to restrain surface settlement during excavation. In this paper, a 3-D hydro-mechanical coupled FE model is developed to numerically simulate the entire process of shield TBM tunneling, which is verified by comparing with real field measurements of ground surface settlement. The effect of permeability and stiffness of ground formations on tunneling-induced surface settlement was discussed in the parametric study. An increase in the face pressure and backfill pressure does not always lead to a decrease in surface settlement, but there are the critical face pressure and backfill pressure. In addition, considering the relatively low permeability of ground formations, the surface settlement consists of two parts, i.e., immediate settlement and consolidation settlement, which shows a distinct settlement behavior to each other.

Ag와 Au가 혼합된 $Bi_{1.84}\;Pb_{0.34}\;Sr_{1.91}\;Ca_{2.03}\;Cu_{3.06}\;O_{10+\delta}$ 산화물 고온초전도체의 초전도특성 (Composite Effect of Ag and Au in the $Bi_{1.84}\;Pb_{0.34}\;Sr_{1.91}\;Ca_{2.03}\;Cu_{3.06}\;O_{10+\delta}$(110K Phase) High-Tc Superconductor)

  • 이민수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권6호
    • /
    • pp.241-248
    • /
    • 2003
  • $Bi_{1.84}Pb_{0.34}Sr_{1.91}Ca_{2.03}Cu_{3.06}O_{10+\delta}$ high $T_{c}$ superconductors containing Ag as an additive were fabricated by a solid-state reaction method. The superconducting properties, such as the structural characteristics, the critical temperatures, the grain size and the image of mapping on the surface were investigated. Samples with Ag and Au of 50 wt% each were sintered at various temperature(820~$850^{\circ}C$). The structural characteristics, the microstructure of surface and the critical temperature with respect to the each samples were analyzed by XRD and SEM, EDS and four-prove methode respectively. The critical temperature showed the result which the Ag additive samples are higher than Au additive samples. The microstructure of the surface showed the tendency which the Ag additive samples become more minuteness than Au additive samples.

Critical heat flux (CHF) in pool boiling under static and rolling conditions

  • Tanjung, Elvira F.;Albdour, Samah A.;Jeong, Yeon Uk;Jo, Daeseong
    • Nuclear Engineering and Technology
    • /
    • 제52권3호
    • /
    • pp.520-529
    • /
    • 2020
  • Experimental investigations were attempted to simultaneously observe the vapor behaviors and critical heat flux under static and rolling conditions. From visualization results, vapor initiated, grew, and detached individually in a vertical direction from the static heated surfaces (at 10, 20, and 30°). While under rolling motion, initiated vapor grew, and interacted with each other, resulting in forming a wider dry spot on the heated surface. Also, it was observed that the vapor drifted upward and stayed on the heated surface longer compared to under static condition. The faster the platform rolls, the longer the vapor stay on the heated surface, significantly decreasing the CHF. On the other hand, as the platform rolls slower (at high rolling period), CHF increases. CHF was decreased with increasing maximum rolling amplitude and inclination angle under both conditions (static and rolling). CHF under rolling conditions was noticed to be lower than under static condition except at maximum rolling amplitude of 10°. The bubble departure frequency at a maximum rolling amplitude of 10° was the highest among all of rolling amplitudes, thereby enhancing the CHF. These results indicate that rolling motion significantly affects vapor behaviors and CHF.

초초임계압 발전용 소재의 표면처리층의 고온 안정성 평가 (High-Temperature Stability Evaluation of Various Surface Treated Layers of Materials for Ultra-Super Critical Power Plants)

  • 류경환;송태권;이재현;김길수;이선호;엄기원
    • 한국재료학회지
    • /
    • 제16권5호
    • /
    • pp.329-335
    • /
    • 2006
  • In order to improve thermal efficiency of the fossil fuel power plants, we need to develop advanced materials with superior durability in the ultra-super critical state, which requires surface modifications for superior surface properties. In this study, we coated the Incoloy 901 and 12-17Cr steels for turbine buckets and valves with nitriding, boriding, and $Cr_3C_2-NiCr$ HVOF(high velocity oxygen flow) method. Then the samples were heat treated at $650^{\circ}C$ for 100 hours in vacuum. We analyzed the evolution behaviors of nitrides such as $Fe_3N,\;Fe_4N$, and CrN and borides such as FeB and $Fe_2B$ with XRD and SEM/EDS by comparing hardnesses and compositions of the coated layers before and after the heat treatments.

CRITICAL HEAT FLUX FOR DOWNWARD-FACING BOILING ON A COATED HEMISPHERICAL VESSEL SURROUNDED BY AN INSULATION STRUCTURE

  • Yang, J.;Cheung, F.B.;Rempe, J.L.;Suh, K.Y.;Kim, S.B.
    • Nuclear Engineering and Technology
    • /
    • 제38권2호
    • /
    • pp.139-146
    • /
    • 2006
  • An experimental study was performed to evaluate the effects of surface coating and an enhanced insulation structure on the downward facing boiling process and the critical heat flux on the outer surface of a hemispherical vessel. Steady-state boiling tests were conducted in the Subscale Boundary Layer Boiling (SBLB) facility using an enhanced vessel/insulation design for the cases with and without vessel coatings. Based on the boiling data, CHF correlations were obtained for both plain and coated vessels. It was found that the nucleate boiling rates and the local CHF limits for the case with micro-porous layer coating were consistently higher than those values for a plain vessel at the same angular location. The enhancement in the local CHF limits and nucleate boiling rates was mainly due to the micro-porous layer coating that increased the local liquid supply rate toward the vaporization sites on the vessel surface. For the case with thermal insulation, the local CHF limit tended to increase from the bottom center at first, then decrease toward the minimum gap location, and finally increase toward the equator. This non-monotonic behavior, which differed significantly from the case without thermal insulation, was evidently due to the local variation of the two-phase motions in the annular channel between the test vessel and the insulation structure.

Critical heat flux in a CANDU end shield - Influence of shielding ball diameter

  • Spencer, Justin
    • Nuclear Engineering and Technology
    • /
    • 제54권4호
    • /
    • pp.1343-1354
    • /
    • 2022
  • Experiments were performed to measure the critical heat flux (CHF) on a vertical surface abutting a coarse packed bed of spherical particles. This geometry is representative of a CANDU reactor calandria tubesheet facing the end shield cavity during the in-vessel retention (IVR) phase of a severe accident. Deionized light water was used as the working fluid. Low carbon steel shielding balls with diameters ranging from 6.4 to 12.7 mm were used, allowing for the development of an empirical correlation of CHF as a function of shielding ball diameter. Previously published data is used to develop a more comprehensive empirical correlation accounting for the impacts of both shielding ball diameter and heating surface height. Tests using borosilicate shielding balls demonstrated that the dependence of CHF on shielding ball thermal conductivity is insignificant. The deposition of iron oxide particles transported from shielding balls to the heating surface is verified to increase CHF non-trivially. The results presented in this paper improve the state of the knowledge base permitting quantitative prediction of CHF in the CANDU end shield, refining our ability to assess the feasibility of IVR. The findings clarify the mechanisms governing CHF in this scenario, permitting identification of potential future research directions.

강우침투에 따른 화강풍화토 사면의 얕은파괴 특성 (Shallow Failure Characteristics of Weathered Granite Soil Slope in accordance with the Rainfall Infiltration)

  • 김선학
    • 한국산학기술학회논문지
    • /
    • 제10권10호
    • /
    • pp.2810-2818
    • /
    • 2009
  • 본 연구는 화강풍화토로 구성된 절토사면에서 얕은파괴의 특성을 규명하고자 우리나라의 강우특성에 따른 한계투수계수를 산정하고, 국내에 분포하는 화강풍화토의 대표적 물성을 기준으로 절토사면의 파괴면까지의 수평거리, 사면의 경사각, 사면높이 그리고 강우로 인한 포화깊이 등에 따른 안정해석을 수행하여 그 결과를 분석하였다. 한계투수계수를 분석한 결과 국내의 지역별 강우특성을 고려한 최대 한계투수계수가 $7.16{\times}10^{-4}cm/sec$의 값으로 나타났다. 최대 한계투수계수 이하의 값을 갖는 국내의 화강풍화토로 구성된 절토사면에서 한계강우강도 이하의 강우가 최소 강우지속시간보다 오랫동안 지속될 때에는 포화깊이에 따른 얕은파괴의 검토가 고려되어져야 할 것으로 판단되었다. 또한, 가상파괴면이 발생하는 수평거리, 포화깊이, 강도정수 변화에 따른 사면안전율의 변화관계를 통해 절토사면의 얕은파괴 특성을 파악 할 수 있었다.