• 제목/요약/키워드: Critical limit

검색결과 647건 처리시간 0.024초

Optimum design of viscous dampers to prevent pounding of adjacent structures

  • Karabork, Turan;Aydin, Ersin
    • Earthquakes and Structures
    • /
    • 제16권4호
    • /
    • pp.437-453
    • /
    • 2019
  • This study investigates a new optimal placement method for viscous dampers between structures in order to prevent pounding of adjacent structures with different dynamic characteristics under earthquake effects. A relative displacement spectrum is developed in two single degree of freedom system to reveal the critical period ratios for the most risky scenario of collision using El Centro earthquake record (NS). Three different types of viscous damper design, which are classical, stair and X-diagonal model, are considered to prevent pounding on two adjacent building models. The objective function is minimized under the upper and lower limits of the damping coefficient of the damper and a target modal damping ratio. A new algorithm including time history analyses and numerical optimization methods is proposed to find the optimal dampers placement. The proposed design method is tested on two 12-storey adjacent building models. The effects of the type of damper placement on structural models, the critical period ratios of adjacent structures, the permissible relative displacement limit, the mode behavior and the upper limit of damper are investigated in detail. The results of the analyzes show that the proposed method can be used as an effective means of finding the optimum amount and location of the dampers and eliminating the risk of pounding.

Wind loads and wind-resistant behaviour of large cylindrical tanks in square-arrangement group. Part 2: CFD simulation and finite element analysis

  • Liu, Qing;Zhao, Yang;Cai, Shuqi;Dong, Shilin
    • Wind and Structures
    • /
    • 제31권6호
    • /
    • pp.495-508
    • /
    • 2020
  • To investigate the structural behaviour of grouped tanks under wind loads, 2 problems need to be figured out, wind pressures on tank shells and critical loads of the shell under these pressure distribution patterns. Following the wind tunnel tests described in the companion paper, this paper firstly seeks to obtain wind loads on the external wall in a squarely-arranged cylindrical tank group by numerical simulation, considering various layouts. The outcomes demonstrate that the numerical method can provide similar results on wind pressures and better insights on grouping effects through extracted streamlines. Then, geometrically nonlinear analyses are performed using several selected potentially unfavourable wind pressure distributions. It is found that the critical load is controlled by limit point buckling when the tank is empty while excessive deformations when the tank is full. In particular, significant reductions of wind resistance are found on grouped full tanks compared to the isolated tank, considering both serviceability and ultimate limit state, which should receive special attention if the tank is expected to resist severe wind loads with the increase of liquid level.

Influence of interfacial adhesive on the failure mechanisms of truss core sandwich panels under in-plane compression

  • Zarei, Mohammad J.;Hatami, Shahabeddin;Gholami, Mohammad
    • Steel and Composite Structures
    • /
    • 제44권4호
    • /
    • pp.519-529
    • /
    • 2022
  • Sandwich structures with the superior mechanical properties such as high stiffness and strength-to-weight ratio, good thermal insulation, and high energy absorption capacity are used today in aerospace, automotive, marine, and civil engineering industries. These structures are composed of moderately stiff, thin face sheets that withstand the majority of transverse and in-plane loads, separated by a thick, lightweight core that resists shear forces. In this research, the finite element technique is used to simulate a sandwich panel with a truss core under axial compressive stress using ABAQUS software. A review of past experimental studies shows that the bondline between the core and face sheets plays a vital role in the critical failure load. Therefore, this modeling analyzes the damage initiation modes and debonding between face sheet and core by cohesive surface contact with traction-separation model. According to the results obtained from the modeling, it can be observed that the adhesive stiffness has a significant influence on the critical failure load of the specimens. To achieve the full strength of the structure as a continuum, a lower limit is obtained for the adhesive stiffness. By providing this limit stiffness between the core and the panel face sheets, sudden failure of the structure can be prevented.

오스템퍼링처리한 구상흑연주철의 피로한도에 미치는 인공결함의 영향 (Influence of Artificial Defect on Fatigue Limit in Austempered Ductile Iron)

  • 김민건;김진학
    • 대한기계학회논문집A
    • /
    • 제23권11호
    • /
    • pp.1922-1928
    • /
    • 1999
  • Rotary bending fatigue tests were carried out to investigate the influence of artificial defects on fatigue limit in annealed and austempered ductile iron. Obtained main results are as follows : (1) Artificial defect(micro hole type, dia.<0.4 mm) on specimen surface did not bring about a obvious reduction of fatigue limit in austempered ductile iron(ADI) as compared with annealed ductile iron. (2) According to the investigation of $\sqrt{area}_c$ which is the critical defect size to crack initiation at artificial defect, $\sqrt{area}_c$ of ADI is larger than that of annealed ductile iron. This shows that the situation of crack initiation at artificial defect in ADI is more difficult in comparison with annealed ductile iron. (3) One of the reasons for the low rate of crack initiation from artificial defect in ADI is that the resistance of matrix to crack initiation is higher than that of annealed ductile iron. (4) In case that the $\sqrt{area}$ of artificial defect and graphite nodule is the same, the rate of crack initiation from graphite nodule is higher than that from artificial defect. This reason is that the serious ruggedness around graphite nodule is formed by austempering treatment.

유전자 알고리즘을 이용한 사면의 임계파괴면 예측기법에 관한 연구 (A Study on the Prediction Technical for Critical Slip surface Using Genetic Algorithm)

  • 김홍택;강인규;황정순;장원호
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.331-338
    • /
    • 1999
  • In the present study, a searching technique for critical slip surface in two dimensional slope stability analysis is proposed. The failure surface generation and analysis has been usually limited to simple geometric shapes. However, more random surfaces need to be examined for some particular ground conditions. For this purpose, random searching technique is developed using genetic algorithm. The generalized limit equilibrium method is employed as the method of stability analysis. Using this technique, the factor of safety is compared with the result by using simplified Bishop's method. In addition, the convergent trend of fitness value is analyzed.

  • PDF

Implementation of Digital Control for Critical Conduction Mode Power Factor Correction Rectifier

  • Shin, Jong-Won;Baek, Jong-Bok;Cho, Bo-Hyung
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.147-148
    • /
    • 2011
  • In this paper, implementation of digital control for critical conduction mode power factor correction (PFC) rectifier is presented. Critical conduction mode is widely used in medium and low power conversion application due to its minimized MOSFET turn-on loss and diode reverse-recovery problem. However, it needs additional zero current detection circuit and maximum frequency limit to properly turn the MOSFET on and avoid the excessive switching loss in light load operation. This paper explains the digital IC implementation and verifies its operation with 200-W prototype PFC rectifier.

  • PDF

수평 원주형 환형내에서의 정상상태의 공기의 자연대류에 대한 이중해 (Dual Solutions for Steady Natural Convection of Air in Horizontal Cylindrical Annulus)

  • 유주식
    • 대한기계학회논문집B
    • /
    • 제20권9호
    • /
    • pp.2981-2990
    • /
    • 1996
  • Dual solutions for steady natural convection of air between two horizontal concentric cylinders are numerically investigated in the range of $D_i$/TEX>/L(=diameter of inner cylinder/gap width)$\leq$10. It is found that, when the Rayleigh number based on the gap width exceeds a certain critical value, a new flow pattern forming two counter-rotating eddies in the half of the annulus can be realized, which is different from the crescent-shaped flow commonly observed. In the new flow pattern, the fluid near the top of the hot inner cylinder moves downward. This solution is found for D$_{i}$/L.geq.0.3, but not for$D_i$/TEX>/L$\leq$0.2. As $D_i$/TEX>/L increase, the critical Rayleigh number is decreased, and tends to a finite limit.t.

마찰 및 음향방출 신호를 이용한 CrN 코팅의 마모수명 평가 (Life Evaluation of CrN Coatings due to Wear Using Friction and Acoustic Emission Sensor)

  • 조정우;이영제
    • Tribology and Lubricants
    • /
    • 제15권4호
    • /
    • pp.328-334
    • /
    • 1999
  • Acoustic emission (AE) sensor was used to evaluate the wear-life of CrN-coated steel disks with 1 $\mu\textrm{m}$ and 4 $\mu\textrm{m}$ coating thickness. The relationship between Af and friction signal from scratch test and sliding test was investigated. The first spatting of CrN film was detected by AR signals in the early stage of coating failures, and overall failures by friction signals. Therefore, the conservative design for coating-life should be done using the results of AE signals. Using the percent contact load, the ratio of sliding normal load to the critical scratch load and the number of cycles to failure was measured to predict the wear-life of CrN film. On the wear-life dia-gram the percent contact loads and the number of cycles to failure showed a good linear relationship on the log coordinate. As the load percentage was decreased, the diagram showed that the wear-limits, at which the coated steels survived more than 35,000 cycles, were about 4∼5% of the critical scratch loads.

Static and dynamic stability of a single-degree-of-freedom autonomous system with distinct critical points

  • Sophianopoulos, D.S.
    • Structural Engineering and Mechanics
    • /
    • 제4권5호
    • /
    • pp.529-540
    • /
    • 1996
  • The dynamic buckling mechanism of a single-degree-of-freedom dissipative/nondissipative gradient system is thoroughly studied, employing energy criteria. The model is chosen in such a manner, that its corresponding static response is associated with all types of distinct critical points. Under a suddenly applied load of infinite duration, it is found that dynamic buckling, occurring always through a saddle, leads to an escaped motion, which is finally attracted by remote stable equilibrium positions, belonging sometimes also to complementary paths. Moreover, although the existence of initial imperfection changes the static behaviour of the system from limit point instability to bifurcation, it is established that the proposed model is dynamically stable in the large, regardless of the values of all other parameters involved.

A Heuristic Application of Critical Power Ratio to Pressurized Water Reactor Core Design

  • Ahn, Seung-Hoon;Jeun, Gyoo-Dong
    • Nuclear Engineering and Technology
    • /
    • 제34권1호
    • /
    • pp.68-79
    • /
    • 2002
  • The approach for evaluating the critical heat flux (CHF) margin using the departure from nucleate boiling ratio (DNBR) concept has been widely applied to PWR core design, while DNBR in this approach does not indicate appropriately the CHF margin in terms of the attainable power margin-to-CHF against a reactor core condition. The CHF power margin must be calculated by increasing power until the minimum DNBR reaches a DNBR limit. The Critical Power Ratio (CPR), defined as the ratio of the predicted CHF power to the operating power, is considered more reasonable for indicating the CHF margin and can be calculated by a CPR orrelation based on the heat balance of a test bundle. This approach yields directly the CHF power margin, but the calculated CPR must be corrected to compensate for many local effects of the actual core, which are not considered in the CHF test and analysis. In this paper, correction of the calculated CPR is made so that it may become equal to the DNB overpower margin. Exemplary calculations showed that the correction tends to be increased as power distribution is more distorted, but are not unduly large.