The influences of mixed strain mode of bending-tension on the critical current. Ic in externally reinforced Bi-2223 tapes and their interaction were investigated in this study. A test fixture which providing a mixed deformation mode of bending-tension to HTS tapes has been newly devised. When the total strain induced in the tape in the mixed strain mode was expressed by the superposition of the bending and tensile strains the irreversible strain for the critical current degradation of Bi-2223 tapes increased, as compared with the simple bending mode case. The $I_c$ degradation at the region exceeding the irreversible strain showed a medium between the simple bending case and the simple tension case. As the initial bending strain imparted increased , namely as the diameter of mandrel adopted decreased. the apparent irreversible strain in Bi-2223 tapes increased . but the increment became smaller As a result. it can be found that the tension to be applied to bent Bi-2223 tapes during cabling should be smaller. as the mandrel diameter becomes smaller.
Basic studies for the treatment of particulate organic substances contained in wastewater by flotation have been conducted. Four kinds of plastics were chosen as the possibly existing organic particles in wastewater and the Zisman plots for these substances were constructed by measuring the contact angle of liquids on their surfaces. The critical surface tensions for these organic substances were estimated based on the constructed Zisman plot and the floatability of organic substances were regarded to be related with their molecular structure. The existence of dissolved organic substances such as a surfactant was observed to affect the extent of flotation of particulate organics. In addition, the consideration of work of adhesion was thought to be better than adopting the critical surface tension as the analytical basis in the operational design of flotation process of organic particles.
Kim, Jin-Sook;Song, Hee-Sang;Chung, Nam-Hyun;Bang, Won-Gi
Applied Biological Chemistry
/
v.48
no.2
/
pp.109-114
/
2005
A bacterium capable of emulsifying hydrocarbon, n-hexadecane, and decreasing surface tension of the culture media using oil collapsing method was isolated. The bacterium was partially identified as Bacillus sp. and named BJS-51. n-Hexadecane was the most effective carbon source for production of biosurfactant. Surface tension was decreased from 76 dyne/cm to 31 dyne/cm and CMD (critical micelle dilution) had the highest value of 5.7 at 3% n-hexadecane. Ammonium phosphate was the most effective nitrogen source, when C/N ratio was 60, surface tension and CMD were 29 dyne/cm and 9.2, respectively. Optimum pH and temperature were 7.2 and $30^{\circ}C$, respectively. Produced biosurfactant was extracted and purified using organic solvent extraction method and preparative HPLC systems. After analysis by various color reaction, this biosurfactant was identified as lipopolysaccharide. Surface tension and CMC (critical micelle concentration) of purified biosurfactant were 27 dyne/cm and 0.08 g/l, repectively. CMD was 9.2, so the yield of biosurfactant was about 0.74 g/l at the optimal conditions. The biosurfactant was very stable at wide range of $pH\;2{\sim}12$ with surface tension $29{\sim}31\;dyne/cm$ and showed $29{\sim}30\;dyne/cm$ of surface tension after heat treatment at $100^{\circ}C$ for 60 min.
Byun, Hyun Young;Sung, Hyung Kyung;Moon, Joon Sik;Lee, A Young;Kwon, Se Young;Kim, So Ra;Park, Mijung
Journal of Korean Ophthalmic Optics Society
/
v.19
no.1
/
pp.23-30
/
2014
Purpose: The present study was aimed to figure out the correlation amongst the evaluation methods for critical micelle concentration, surface tension and protein cleaning efficacy to evaluate cleaning efficacy of contact lens care products. Methods: The critical micelle concentration of surfactants and the actual concentration of surfactants in contact lens care solutions were investigated by employing references published and related information. Surface tension of contact lens care solutions was measured by surface tension device at $25{\pm}1^{\circ}C$, and contact lenses made of lotrafilcon A, comfilcon A and balafilcon A were washed with contact lens care solutions after the incubation in artificial tears for 14 days and their cleaning efficacy was compared. Results: Among the 22 contact lens care products, 9 products provided the label of the concentration of surfactant, and 7 products showed higher concentration of surfactant than the critical micelle concentration reported in references. As a result of measuring surface tension, the surface tension of lens care products for soft contact lens was generally lower than other care products. When examined the removal effect of protein deposited on lens surface, it was known that the care products having lower surface tension showed higher protein removal efficiency. Conclusions: The surface tension is low when surfactant concentration in contact lens care solutions is high, and the removal effect of protein deposited is accordingly increased with the decrease of surface tension. Thus, these indicate the correlation amongst the evaluation methods for cleaning efficacy.
Tissue 02 tension is an important guide in detection of the general condition in critical patients. The tissue 0, is more difficult to measure with 0, sensor in skeletal muscle and subcutaneous tissues to present. But it is much easier to measure 0, tension in bladder urine with Censini catheter in Foley catheter than in tissue. We have measured 0, tension in bladder urine, main pulmonary artery and radial artery in 16 patients in chest surgical department of Yonsei University. College of Medicine from September 26 to December 22, 1981. Six patients were male and ten patients were female. Their ages ranged from 8 to 43 years. The correlation equation between the simultaneously measured PuO2 and PvO2 was found to be Ypvo2=4.04 + 0.88 Xpuo2 [r=0.88, p<0.0001] in regression curve with computer [HP/3,000, Program: SPSS] in the Yonsei University. Measurement of 0, tension in bladder urine and MPA will be rather simple, rapid and reproducible method than that of the 0, tension in tissues. But the speed of 0, consumption in urine is fast and so the 0, tensions in bladder urine were measured as soon as possible after they were collected. They were no complications or morbidity during measurement of 0, tension in these procedures except spontaneous removal of radial arterial cannulas in 2 patients.
Huang, Xiaogang;Zhou, Zhen;Zhu, Yazhi;Zhu, Dongping;Lu, Lu
International journal of steel structures
/
v.18
no.5
/
pp.1784-1800
/
2018
Tension-shear loading is a common loading condition in steel structures during the earthquake shaking. To study ductile fracture in structural steel under multiple stress states, experimental investigations on the different fracture mechanisms in Chinese Q235 steel were conducted. Different tension-shear loading conditions achieved by using six groups of inclined notch butterfly configurations covering pure shear, tension-shear and pure tension cases. Numerical simulations were carried out for all the specimens to determine the stress and strain fields within the critical sections. Two tension-shear fracture models were calibrated based on the hybrid experimental-numerical procedure. The equivalent fracture strain obtained from the round bar under tensile loading was used for evaluating these two models. The results indicated that the tension-shear criterion as a function of the shear fracture parameter had better performance in predicting the fracture initiation of structural steel under different loading conditions.
In this study, various unsaturated polyester (UPE) resins were prepared from the condensation polymerization of mixtures of saturated (isophthalic acid : IPA) and unsaturated (maleic anhydride : MA) dibasic acids with propylene glycol (PG), neopentyl glycol (NPG). The critical surface tension (Υ$_{c}$) for the surface characteristics of a solid were estimated by Zisman plot, and the structure-property relationship was investigated by measuring the rheology of resins. The values of Υ$_{c}$ for glass of solid were 30.5 mNㆍm$^{-1}$ for UPE resin liquids. As the content of NPG in a PG/NPG glycol mixture increased, both the contact angle and the surface tension of the UPE resin liquids were found to decrease. The dynamic viscoelasticities of UPE resins with different glycol molar ratios were also measured. Shear rate dependence of viscosity and angular frequency dependence of storage, and loss modulus tended to decrease with increasing NPG content.
Journal of the Korea Academia-Industrial cooperation Society
/
v.10
no.9
/
pp.2402-2408
/
2009
This study conducted a static tensile test in order to prevent the lowering of load carrying capacity caused by critical sections made by over bolt holes in the base plate and the cover plate of steel member joints using high-tension bolts. The change of the load carrying capacity of joints was examined by comparison of the maximum load on joint fracture obtained from the tensile test with critical section rate and design strength. According to the results, the rate of decrease in strength was higher when the critical section rate was high, and in particular, decrease in strength was affected much more by critical sections in the base plate than by those in the cover plate. In high-tension bolt joints using over bolt holes for the base plate and the cover plate, load carrying performance was somewhat lower than that in joints using standard bolt holes, but the maximum tensile strength on facture was over 15% higher than design fracture strength. According to the results of this study, the use of over bolt holes in high-tension bolt joints had an insignificant effect on the lowering of load carrying capacity, so the allowance of over bolt holes in the joints of steel members is expected to enhance to the economy and efficiency of the works.
Noh Jang Sook;Lee Kwang Soon;Chang Sae Hee;Ahn Woon-Sun
Journal of the Korean Chemical Society
/
v.18
no.5
/
pp.354-357
/
1974
The critical micelle concentration(CMC) of sucrose monostearate is determined between 20 and $40^{\circ}C$, and the effect caused by the addition of sucrose distearate on the CMC is also studied. It is found that, when both of monoester and diester are dissolved, the curve of surface tension of the solution versus the concentration shows a discontinuity at about 40 dyne $cm^{-1}$ of the surface tension. The discontinuity is interpreted as the associate formed between monoester and diester changes its surface orientation at this region.
This paper investigates the dependency of the critical content for electrical conductivity of carbon powder-filled polymer matrix composites with different matrixes as a function of the carbon powder content (volume fraction) to find the break point of the relationships between the carbon powder content and the electrical conductivity. The electrical conductivity jumps by as much as ten orders of magnitude at the break point. The critical carbon powder content corresponding to the break point in electrical conductivity varies according to the matrix species and tends to increase with an increase in the surface tension of the matrix. In order to explain the dependency of the critical carbon content on the matrix species, a simple equation (${V_c}^*=[1+ 3({{\gamma}_c}^{1/2}-{{\gamma}_m}^{1/2})^2/({\Delta}q_cR]^{-1}$) was derived under some assumptions, the most important of which was that when the interfacial excess energy introduced by particles of carbon powder into the matrix reaches a universal value (${\Delta}q_c$), the particles of carbon powder begin to coagulate so as to avoid any further increase in the energy and to form networks that facilitate electrical conduction. The equation well explains the dependency through surface tension, surface tensions between the particles of carbon powder.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.