• 제목/요약/키워드: Criteria pollutants

검색결과 161건 처리시간 0.022초

실내공기질의 건강성능 평가모델 연구 (A Health Performance Evaluation Model of Building Indoor Air Quality)

  • 정기;이동훈;최재휘;김선국
    • KIEAE Journal
    • /
    • 제10권3호
    • /
    • pp.3-10
    • /
    • 2010
  • As indoor air quality directly affects health and comforts of the residents, researchers from different countries have continued to explore criteria by which indoor air quality can be indicated in a scientific and quantitative manner over the past several decades. However, there are many possibilities that can deteriorate indoor air quality. Due to the uncertainty of influence factors, it is quite difficult to develop a correct evaluation model and quantitative method. Furthermore, the effects from the indoor air pollutants have different levels, leading to the difficulties to apply the regular standard. This study aims to propose evaluation criteria by using the FD-AHP analysis. Obtained findings will be beneficial to construct apartment buildings, commercial buildings and others health performance evaluation framework.

환경성적표지 인증을 위한 한국형 틸팅열차의 전과정평가 (Life Cycle Assessment of Korean Tilting Train eXpress for Environmental Declaration of Product(EDP))

  • 이현배;김용기;이건모
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.2262-2269
    • /
    • 2010
  • A recent Tilting train development operation for existing line high speed, already developed "Korean Tilting Train eXpress(bellow TTX)" and that doing demonstration of operation. And TTX are going to commercial service in 2012. They are preparing Environmental Declaration of Product(bellow EDP) for offering environmental impact of TTX to customer. EDP calculated environmental impact of target product's whole life cycle(raw material and manufacturing, distribution, use, end of life) more quantity for that improving environmental impact and then certification them, it is using for that estimate some part of existence of specific pollutants, GHGs, energy consumption and recycling ratio. In this study, 1) analyze the process of getting EDP, 2) satisfy common criteria and each criteria(plan) in the Product Category Rules(bellow PCRs) provided KEITI, 3) according to ISO 14044, implementation of LCA. 4) These results be shown Characterized Impact(bellow CI) about each life cycle stage and six impact categories(ARD, GWP, OD, AD, EU, POC).

  • PDF

도로청소 수거퇴적물의 특성과 비점오염물질 저감효과 (Characteristics of Collected Sediments from Road Sweeping and Reduction in the Nonpoint Source Pollutants Loading)

  • 정권;강희만;고석오
    • 한국도로학회논문집
    • /
    • 제13권2호
    • /
    • pp.187-193
    • /
    • 2011
  • 도로에서의 강우유출수 내 포함된 오염물은 주요한 비점오염원으로 간주되고 있으며 비점오염물질 저감을 위하여 많은 대책이 적용되고 있다. 도로청소에 의한 방법 또한 오염물의 강우유출에 의한 배출양을 감소시킬 수 있는 대책 중의 하나로 인식되는 추세에 있다. 본 연구에서는 도로청소 시 수거된 토사입자들의 특성을 파악하고 퇴적토사에 함유된 오염물질의 농도를 분석하였다. 분석결과를 바탕으로 하여 도로 구간별로 도로청소에 의하여 저감할 수 있는 오염물의 양을 평가하였다. 도로청소를 통하여 수거된 퇴적토사는 모래질로 분석되었으며 세립토 비중은 낮은 결과를 보였다. 퇴적토사 내 오염물의 양은 토양환경기준을 초과하지 않았으나 청소작업시 물을 살수함으로써 토사에 포함된 오염물이 세척되어 침출수로 미리 배출되는 것에 기인한다고 판단된다. 두 도로구역에 대하여 오염물 농도, 발생 퇴적토사량, 오염물 원단위를 적용하여 저감할 수 있는 오염물 양을 평가한 결과, ${\bigcirc}{\bigcirc}$지역에 대하여 TSS 31.4% 및 ${\triangle}{\triangle}$지역에서는 TSS 7.7%의 TSS 저감량이 도출되었다. 중금속과 같은 타 오염물의 경우 훨씬 낮은 저감량이 평가되었으나 이는 물의 살수로 인하여 퇴적토사 내 오염물이 침출수로 배출된 것에 기인한다고 판단된다. 보다 정확하게 도로청소에 의하여 저감할 수 있는 오염물의 양을 산정하기 위하여 보다 자세하고 체계적인 연구가 필요하다고 판단된다.

충남지역 미적용 다중이용시설의 실내공기질에 관한 연구 (A Study of Indoor Air Quality of Public Facilities in Chung-Nam Area)

  • 홍성철;조혜미;조태진;이치원;정용택;손부순
    • 환경위생공학
    • /
    • 제23권2호
    • /
    • pp.35-45
    • /
    • 2008
  • In order to recommend criteria for the administration law on indoor air quality, this study was conducted to examine the distribution and the concentration of indoor air pollutants ($PM_{10},\;CO_2$, CO, HCHO, TBC, $NO_2$, Rn, VOCs, asbestos, $O_3$) in public facilities in the Chung-Nam area. The concentrations of indoor air pollutants were obtained from sixty seven public facilities such as a cinema, an office, a restaurant, a theater and an academy. This study was performed from August to December, 2005. The results of this study showed that the concentrations of indoor air pollutants such as $PM_{10},\;CO_2$, CO, HCHO, TBC, Rn and $O_3$ were less than the recommended limits. However, the average concentration of VOCs was $521.73{\mu}g/m^3$ (GM : $221.69{\mu}g/m^3$), which was higher than the recommended limit of $400{\mu}g/m^3$. Moreover, the average concentration of $NO_2$ was 345.66ppb (GM : 69.95ppb), which was higher than the recommended limit of 50 ppb. The correlation between the concentrations of indoor air pollutants and the type of facilities with respect to $CO_2$, TBC and Rn was statistically low (p<0.05). However, the correlation was high in terms of the CO and $O_3$ concentrations (p<0.01). No relationship between the indoor air pollutants and the type of facilities was observed for $PM_{10}$, VOCs and $NO_2$. The year of construction was compared to the concentrations of indoor air pollutants. Specifically, when the construction date was less than 3 years, the HCHO, VOCs and TBC concentrations were $44.75{\mu}g/m^3,\;555.07{\mu}g/m^3$ and $337.79CFU/m^3$, respectively. These concentrations were $120{\mu}g/m^3$ and $211.84CFU/m^3$ higher for VOCs and TBC than the concentrations obtained from the facilities more than 3 years. However, the concentration of HCHO was similar between the facilities older and younger than 3 years of age. Year, temperature, humidity and indoor air pollutant correlation analyses showed that temperature and humidity, temperature and TBC, temperature and $O_3,\;PM_{10}$ and $NO_2$, HCHO and VOCs, $CO_2$ and Rn had positive relationships. However temperature and Rn, humidity and $CO_2,\;CO_2$ and $O_3,\;O_3$ and Rn had negative relationships. Accordingly, it will be necessary to manage the factors affecting indoor air quality so that the residents can have a more comfortable and healthier living environment. Ultimately, the results of this study are expected to be utilized as baseline data.

원통형 액체저장탱크 내진설계기준의 비교연구 (A Comparative Study on the Earthquake Resistant Design Criteria for Cylindrical, Liquid-Storage Tanks)

  • 국승규
    • 한국지진공학회논문집
    • /
    • 제2권2호
    • /
    • pp.69-75
    • /
    • 1998
  • 액체저장탱크 구조물은 지진에 의해 붕괴되는 경우 구조물의 파손 및 저장물의 손실에 의한 직접피해보다 파급효과(유독물질이나 오염물질의 유출로 지속적인 재산피해 및 환경파괴를 초래함)가 더욱 심각하므로 이러한 직, 간접적 피해를 최소화하기 위한 내진설계기준의 제정이 시급한 과제이다. 본 논문에서는 원통형 액체저장탱크의 내진설계기준을 마련하기 위한 기초작업으로 뉴질랜드지침과 오스트리아지침의 해석방법을 고찰하고, 수치해석 예의 결과를 비교하여 두 지침의 적용타당성 및 문제점을 제시하였다.

  • PDF

2003년 5월 러시아지역에서 발생한 산불로 인한 스모크 에어로졸 플룸의 영향 (Impact of the Smoke Aerosol from Russian Forest Fires on the Atmospheric Environment over Korea during May 2003)

  • 이권호;김정은;김영준;김준
    • 한국대기환경학회지
    • /
    • 제20권5호
    • /
    • pp.603-613
    • /
    • 2004
  • Extensive forest fires occurred across the border in Russia. particularly east of Lake Baikal between the Amur and Lena rivers in May 2003. These forest fires released large amounts of particulates and gases into the atmosphere. resulting in adverse effects on regional air quality and the global radiation budget. Smoke pollution from the Russian fires near Lake Baikal was sometimes transported to Korea through Mongolia and eastern China. In this study ground based radiation (visible and UV-B) data measured during May 2003 at Seoul and Kwangju were analyzed to estimate smoke aerosol impacts on solar radiation. Surface criteria air pollutants ($PM_{10}$, CO, $O_3$) data were also obtained from National Institute of Environmental Research (NIER) during smoke aerosol event period (19 May~24 May 2003). Large Aerosol Optical Depth (AOD) 1.0~3.0 was observed during this period due to the influence of the long range transport of smoke aerosol plume from the Russian fires, resulting in short-wavelength direct aerosol radiative forcing of -90~ -200W/$m^2$. These smoke aerosol plume caused decrease in surface UV-B radiation up to 80% and increase in PM_(10) concentration up to 200${\mu}g/m^3$ exceeding the 24 hour ambient air quality standard.

오염총량관리 할당부하량 초과지역의 최종 평가기준에 관한 연구 (A Study on the Final Evaluation Criteria of Allocation Exceedance Regional in Total Maximum Daily Load)

  • 오승영;한미덕;김석규;안기홍;김옥선;김용석;박지형
    • 한국물환경학회지
    • /
    • 제32권5호
    • /
    • pp.450-457
    • /
    • 2016
  • The Total Maximum Daily Load (TMDL) is a watershed management system that involves the establishment of the target water quality, the calculation of permission loading (allocation loading), and the control of total pollutants for each unit watershed. Allocation loading is assessed through the comprehensive implementation assessment of the previous year's plan. Assessment results are used for follow-up management measures such as the limit of development and updating of TMDL Management Implementation Plans for the next planning period. Although detailed assessment criteria are important, they are not currently available. Therefore, we suggested assessment criteria by comparing two methods('integration method' and 'separation method') using combination point and non-point discharge loading. We also examined the penalty criteria considering controllable load local government and updating methods of the TMDL Management Implementation Plan for the next planning period.

오염등급과 유형화 분석의 연계에 의한 북한강 최북단 유역 소하천의 수질개선방안 연구 (Water Quality Improvement Plan for Small Streams in the Northernmost Basin of Bukhan River based on Pollution Grade and Typological Analysis Linkage)

  • 이용석;전만식;김문숙
    • 한국물환경학회지
    • /
    • 제32권3호
    • /
    • pp.281-290
    • /
    • 2016
  • In the northernmost basin of the Bukhan River, pollution sources can have a concentrated distribution. In these basins, small streams show low flow with various and rapid water quality change in low pollutants load. Therefore, a water quality improvement plan of small streams and main stem will be necessary to establish the characteristics of small streams. This study selected a representative Hwacheon-gun in the northernmost basin of the Bukhan River. Hydro analysis was performed with GIS tools using DEM. A total of 152 small streams were listed. A total of 51 survey locations were selected after applying the selection criteria. Flow rate and water qualities were investigated. Pollution sources and pollutants loads were calculated for each basin. Pollution grade and typological classification were performed by cluster analysis using standardized environmental condition factors. As a result, G04, G01, H01 locations were found to have the worst pollution grades whereas J01, P01, and P02 had less pollution. Typological analyses were able to classify six types for the surveyed small streams. An effective water quality improvement plan was obtained based on the results of pollution grade and typological analysis using environmental condition factors of this study.

서울지역의 시정 장애 요인에 관한 연구 (On the Origin of Visibility Degradation in Seoul)

  • 윤순창;이강웅
    • 한국대기환경학회지
    • /
    • 제14권3호
    • /
    • pp.229-236
    • /
    • 1998
  • Visibility is a good indicator of comprehensive alto quality. The prevailing visibility in Seoul is no better than the past although the average concentration of SO2 and TSP (total suspended particulate) has decreased quite significantly in the past decade, owing to the government efforts to reduce the emission. Then, a question arises why visibility has not been improved. In order to answer this question we have investigated which components of air pollutants are most responsible for the visibility degradation in Seoul. Analysis on the visibility vs the aerosol sixte distribution measured by an optical particle counter shows that the particles of the size interval between 0.5mm and 2.5mm are most responsible for the visibility degradation. Among the criteria air Pollutants, NOB concentration is found to be moot responsible, rather than PM10. ton analysis of the particulate collected by a high volume sampler shows that the nitrate component increases more significantly than other ions when visibility becomes very poor. Therefore, we conclude that the major causes of visibility degradation in Seoul are the increase of NOB, nitrates and the particles of the size range between 0.5mm and 2.5mm.

  • PDF

연안해역 생태계 건강성 평가의 의미와 국내 적용 방향 (Implications for Coastal Ecosystem Health Assessments and Their Applications in Korea)

  • 김영옥;심원준;염기대
    • Ocean and Polar Research
    • /
    • 제29권4호
    • /
    • pp.319-326
    • /
    • 2007
  • Coastal marine ecosystems continue to suffer unrelenting pressures from human population growth, increased development, and climate change. Moreover, these systems' capacity for self-repair is declining with such increases in anthropogenic production of various pollutants. What is the present health status or condition of the coastal ecosystem? If our coastal areas are unhealthy, which conditions are considered serious? To answer such questions, the United States, Canada, and Australia are currently assessing coastal ecosystem health using systematic monitoring programs as well as identifying and implementing management plans to improve the health of degraded coastal ecosystems. To evaluate marine environments, Korea is currently using a limited number of factors to estimate water quality. In fact, we are ill-prepared for assessing coastal ecosystem health because no biologically specific criteria are in place to measure the responses to various pollutants. We should select ecosystem-specific indicators from physicochemical stressors and evaluate the subsequent biological responses within each ecosystem. Furthermore, a set of practical indicators should be generated by considering the characteristics and uses of a local coastal area and the key issues at hand. The values of indicators should be presented as indices that allow understanding by the general public as well as by practitioners, policy makers, environmental managers and other stakeholders.