• Title/Summary/Keyword: Crash test

Search Result 326, Processing Time 0.033 seconds

Secure Jini Service Architecture Providing Ubiquitous Services Having Persistent States (유비쿼터스 서비스 상태지속을 지원하는 안전한 Jini 서비스 구조)

  • Kim, Sung-Ki;Jung, Jin-Chul;Park, Kyung-No;Min, Byoung-Joon
    • The KIPS Transactions:PartC
    • /
    • v.15C no.3
    • /
    • pp.157-166
    • /
    • 2008
  • The ubiquitous service environment is poor in reliability of connection and also has a high probability that the intrusion against a system and the failure of the services may happen. Therefore, It is very important to guarantee that the legitimate users make use of trustable services from the viewpoint of security without discontinuance or obstacle of the services. In this paper, we point out the problems in the standard Jini service environment and analyze the Jgroup/ARM framework that has been developed in order to help fault tolerance of Jini services. In addition, we propose a secure Jini service architecture to satisfy the security, availability and quality of services on the basis of the analysis. The secure Jini service architecture we propose in this paper is able to protect a Jini system not only from faults such as network partition or server crash, but also from attacks exploiting flaws. It provides security mechanism for dynamic trust establishment among the service entities. Moreover, our secure Jini service architecture does not incur high computation costs to merge the user service states because of allocation of the replica based on each session of a user. Through the experiment on a test-bed, we have confirmed that proposed secure Jini service architecture is able to guarantee the persistence of the user service states at the level that the degradation of services quality is ignorable.

The Clinical Study on 77 Traffic Accident Patients (교통사고 환자 77례에 대한 임상적 고찰)

  • Hwang, Hee-Sang;Park, Jae-Yeon;Kim, Min-Seok;Jeon, Jae-Cheon;Jung, Ki-Hoon;Lee, Tae-Ho;Roh, Jeong-Du;Lee, Eun-Yong
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.4 no.2
    • /
    • pp.85-98
    • /
    • 2009
  • Objectives : The purpose of this study was to find out tendency of traffic accident patients treated in korean medicine hospital. Methods : We investigated 77 patients who were treated in Semyung University Korean Medicine Hospital from 1 st, January, 2007 to the 30st September, 2009. Results and Conclusions : 1. In distribution of gender and age, the rate of male was 36.4%, that of female was 63.6% and majority of patients were twenties, thirties and forties. 2. In the traffic accident patterns, the most was car crash from behind(49.4%) and after traffic accident, 42 patients(54.6%) visited our hospital in less than 5 days. 3. 22 patients(28.6%) choose the oriental medical treatment for primary care. And 35 patients(45.4%) visited our hospital due to preference of oriental medicine. 4. In partial pain, most was the neck(76.6%), followed by low back(61.0%). 5. In radiation test(excluded sprain and straightening), the most was HIVD of L-SPINE(14.0%). 6. In the periods of admission, less than 7 days was the 1st(36.4%), 14 days was the 2nd(27.3%). 7. The treatment was effective to 67 patients out of 77 patients who had been hospitalized.

  • PDF

The actual type of domestic safety accident of children and the safety knowledge according to variables of parents (가정내 유아의 안전사고 유형과 부모의 변인에 따른 안전지식)

  • Kim, Ji-Young;Kim, Na-Rim
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.454-461
    • /
    • 2017
  • The purpose of this study is to investigate the types of domestic safety accidents involving children and to verify the difference of safety knowledge according to variables of parents. Subjects include 226 parents who have 3-5 year old infants enrolled in kindergartens and day care centers in I-city, Jeollabuk-do. The study tools are modified and complemented questionnaire for the study purpose referred to the preceding research data and the literature. For the processing of collected data, frequency analysis, descriptive statistics, one-way ANOVA, and the Duncan post-test were utilized using the SPSS program. The results of this study are as follows: First, safety accidents occurred at the majority of homes which have infant children. On average, the occurrence frequency was 1.78 times per six months. The accidents involving infants occurred in the order of drop or slip, crash or impact, stricture or jamming, fall, stab or cut, burn, swallow or inhalation. Second, both parents had an average level of safety knowledge. There was a distinction in the areas of 'fall' and 'first aid' according the mother's age. In addition, stay-at-home mothers had the higher level of safety knowledge compared with working mothers in the areas of 'general safety knowledge' and 'fire'. There was a distinction in the area of 'fire' according to the father's age. Given these findings, safety training programs for parents to improve safety knowledge needs to be developed.

The Clinical Study on 120 Cases with Traffic Accident (교통사고 환자 120례에 대한 임상적 고찰)

  • Lee, Ji-Eun;Jung, Hyo-Keun;Ryu, Chung-Ryul;Cho, Myoung-Rae;Wi, Jun;Ryu, Mi-Seon;Kim, Ja-Young
    • Journal of Acupuncture Research
    • /
    • v.25 no.6
    • /
    • pp.135-143
    • /
    • 2008
  • Objectives : The main purpose of this research is to make a survey of the effective way of the Oriental medical care and to enlarge the range of Oriental medical treatment about traffic accidental patients. Methods : In following research, we surveyed 120 patients of traffic accident who were hospitalized in Dong-Shin Oriental Medical Hospital from October, 1, 2007 to August, 20, 2008 according to medical chart. Results : 1. In distribution of gender and age, the rate of male was 35.8%, that of female was 64.2% and the majority of the patients were twenties and thirties. 2. In the traffic accident patterns, the most was car crash from behind(61.7%) and after traffic accident, 75 patients(62.5%) visited our hospital for oriental medical treatment in less than 5days. 3. 46 patients(38.3%) choose the oriental medical treatment for the primary care and after medical care, 36 patients(31.7%) visited our hospital due to dissatisfaction of current treatment and maintained pain. 4. Partial pain was the chief complaint and the most of painful parts was neck(76.7%), followed by low back(69.2%). 5. Though radiation test, the most was cervical spine sprain(76.7%), followed by straightening of lumbar spine(66.7%). 6. In the periods of admission, less than 7 days was the most(53.3%), followed by less than 14 days(35.9%). 7. The treatment was effective to 93 patient out of 106 who had been hospitalized for less than 14 days. Conclusions : This data suggested that the Oriental medical care could be more effective treatment about traffic accidental patients without surgical injury.

  • PDF

Analytical Assessment of Blast Damage of 270,000-kL LNG Storage Outer Tank According to Explosive Charges (270,000 kL급 LNG 저장 탱크 외조의 폭발량에 따른 손상도 해석적 평가)

  • Kim, Jang-Ho Jay;Choi, Seung-Jai;Choi, Ji-Hun;Kim, Tae-Kyun;Lee, Tae-Hee
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.6
    • /
    • pp.685-693
    • /
    • 2016
  • The outer tank of a liquefied natural gas (LNG) storage tank is a longitudinally and meridionally pre-stressed concrete (PSC) wall structure. Because of the current trend of constructing larger LNG storage tanks, the pre-stressing forces required to increase wall strength must be significantly increased. Because of the increase in tank sizes and pre-stressing forces, an extreme loading scenario such as a bomb blast or an airplane crash needs to be investigated. Therefore, in this study, the blast resistance performance of LNG storage tanks was analyzed by conducting a blast simulation to investigate the safety of larger LNG storage tanks. Test data validation for a blast simulation of reinforced concrete panels was performed using a specific FEM code, LS-DYNA, prior to a full-scale blast simulation of the outer tank of a 270,000-kL LNG storage tank. Another objective of this study was to evaluate the safety and serviceability of an LNG storage tank with respect to varying amounts of explosive charge. The results of this study can be used as basic data for the design and safety evaluation of PSC LNG storage tanks.

Patrol Monitoring Plan for Transmission Towers with a Commercial Drone and its Field Tests (상용화 드론을 이용한 송전선로 점검방안 및 현장시험)

  • Kim, Seok-Tae;Park, Joon-Young;Lee, Jae-Kyung;Ham, Ji-Wan;Choi, Min-Hee
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.4 no.2
    • /
    • pp.115-123
    • /
    • 2018
  • Various types of robots running on power transmission lines have been developed for the purpose of line patrol monitoring. They usually have complex mechanism to run and avoid obstacles on the power line, but nevertheless did not show satisfactory performance for going over the obstacles. Moreover, they were so heavy that they could not be easily installed on the lines. To compensate these problems, flying robots have been developed and recently, multi-copter drones with flight stability have been used in the electric power industry. The drones could be remotely controlled by human operators to monitor power distribution lines. In the case of transmission line patrol, however, transmission towers are huge and their spans are very long, and thus, it is very difficult for the pilot to control the patrol drones with the naked eye from a long distance away. This means that the risk of a drone crash onto electric power facilities always resides. In addition, there exists another danger of electromagnetic interference with the drones on autopilot waypoint tracking under ultra-high voltage environments. This paper presents a patrol monitoring plan of autopilot drones for power transmission lines and its field tests. First, the magnetic field effect on an autopilot patrol drone is investigated. Then, how to build the flight path to avoid the magnetic interference is proposed and our autopilot drone system is introduced. Finally, the effectiveness of the proposed patrol plan is confirmed through its field test results in the 154 kV, 345 kV and 765 kV transmission lines in Chungcheongnam-do.