• Title/Summary/Keyword: Cr(VI) reduction

Search Result 72, Processing Time 0.025 seconds

Kinetic Analysis and Mathematical Modeling of Cr(VI) Removal in a Differential Reactor Packed with Ecklonia Biomass

  • Park, Dong-Hee;Yun, Yeoung-Sang;Lim, Seong-Rin;Park, Jong-Moon
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.11
    • /
    • pp.1720-1727
    • /
    • 2006
  • To set up a kinetic model that can provide a theoretical basis for developing a new mathematical model of the Cr(VI) biosorption column using brown seaweed Ecklonia biomass, a differential reactor system was used in this study. Based on the fact that the removal process followed a redox reaction between Cr(VI) and the biomass, with no dispersion effect in the differential reactor, a new mathematical model was proposed to describe the removal of Cr(VI) from a liquid stream passing through the differential reactor. The reduction model of Cr(VI) by the differential reactor was zero order with respect to influent Cr(IlI) concentration, and first order with respect to both the biomass and influent Cr(VI) concentrations. The developed model described well the dynamics of Cr(VI) in the effluent. In conclusion, the developed model may be used for the design and performance prediction of the biosorption column process for Cr(VI) detoxification.

Enhanced photocatalytic Cr(VI) reduction using immobilized nanotubular TiO2 on Ti substrates and flat type photoreactor (티타늄 금속지지체에 고정화된 나노튜브 광촉매와 평판형 광반응기를 이용한 Cr(VI) 환원처리 효율 향상 연구)

  • Kim, Youngji;Joo, Hyunku;Yoon, Jaekyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.1
    • /
    • pp.33-38
    • /
    • 2015
  • In this study, flat-type photocatalytic reaction system is applied to reduce toxic hexavalent chromium (Cr(VI)) to trivalent chromium (Cr(III)) in aqueous solution under UV irradiation. To overcome the limitation of conventional photocatalysis, a novel approach toward photocatalytic system for reduction of hexavalent chromium including nanotubular $TiO_2$ (NTT) on two kinds of titanium substrates (foil and mesh) were established. In addition, modified Ti substrates were prepared by bending treatment to increase reaction efficiency of Cr(VI) in the flat-type photocatalytic reactor. For the fabrication of NTT on Ti substrates, Ti foil and mesh was anodized with mixed electrolytes ($NH_4F-H_2O-C_2H_6O_2$) and then annealed in ambient oxygen. The prepared NTT arrays were uniformly grown on two Ti substrates and surface property measurements were performed through SEM and XRD. Hydraulic retention time(HRT) and substrate type were significantly affected the Cr(VI) reduction. Hence, the photocatalytic Cr(VI) reduction was observed to be highest up to 95% at bended(modified) Ti mesh and lowest HRT. Especially, Ti mesh was more effective as NTT substrate in this research.

Comparison of Sampling Filters for Airborne Hexavalent Chromium in Plating Operation (도금공정 공기중 6가 크롬 시료채취여과지 비교에 관한 연구)

  • 이병규;신용철
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.2
    • /
    • pp.69-76
    • /
    • 2003
  • Hexavalent chromium may reduce on polyvinyl chloride (PVC) filter during sampling and storage of sample. Recently, new or modified filters for preventing Cr(VI) from the reduction has been introduced. Thus, this study was performed to compare the reduction behaviors of Cr(VI) on several sampling filters and to find the most appropriate filter for airborne Cr(VI) sampling in plating operation. The results were as follows. 1. There were statistically significant differences among PVC, polytetrafluoroethylene (PTFE). glass fiber (GF) and polyvinylidene fluoride (PVDF) filters in recovery rates of spiked Cr(VI) samples by storage time(p<0.05). There was no significant difference between PVC and PTFE filters(p>0.05). The PVC and PTFE filters showed higher recoveries than GF and PVDF filters(p<0.05). 2. The quartz fiber(QF) filter treated with an alkali solution(2% NaOH/3% Na$_2$CO$_3$, 1% NaOH) showed a significantly higher recovery of Cr(VI) by storage time than other filters(GF and QF filter)(p<0.05). There was no difference in recovery of Cr(VI) between alkali-treated and untreated GF it filters(p>0.05). But the QF filters treated with two alkali solution showed a significantly higher recovery than the untreated QF filter(p<0.05). There was no significant difference in recovery of Cr(VI) between QF filters treated with 1% NaOH and 2% NaOH/3% Na$_2$CO$_3$(p>0.05). In conclusion, treatment of QF fillers with alkali solution was most effective in protecting from the reduction of Cr(VI).

Fabrication of $TiO_2$ Electrode with Seawater; Production of Hydrogen and Cr(VI) Reduction (해수전해질을 활용한 광전극제조 및 광활성 평가)

  • Shim, Eun-Jung;Park, Min-Sung;Her, A-Young;Joo, Hyun-Ku;Yoon, Jae-Kyung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.226-229
    • /
    • 2009
  • The present works were performed that titanium foil was anodized in various dilution ratios of seawater and distilled water with 10V external voltage applied, then annealed at $450^{\circ}C$ to obtain $TiO_2$ on the Ti substrate. The prepared samples were characterized by instruments (XRD, SEM, and photocurrent) and used to investigate rate of hydrogen production in photoelectrochemical cell as well as Cr(VI) reduction. As the results of experiments, the anodized $TiO_2$ in seawater electrolytes, which are ranged from 15 to 50 times dilution of seawater, was showed a relatively higher hydrogen production (ca. 97~110 umol/hr-$cm^2$) and Cr(VI) reduction (ca. 95% reduction).

  • PDF

Reduction of hexavalent chromium (Cr(VI)) under acidic conditions during its determination in cement (시멘트 6가 크롬 (Cr(VI))정량분석법에 관한 고찰 - 분석과정에서 Cr(VI) 의 환원에 따른 오차제어-)

  • Moon, Se-Heum;Jeong, Jae-Hong;Lee, Seung-Hoon;Lee, Seung-Heun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.897-900
    • /
    • 2008
  • Some substances of cement could make underestimate concentration of hexavalent chromium(Cr(VI)) as they reduce Cr(VI) to Cr(III) in acidic condition during the determination of Cr(VI) content in cement. The reduction of Cr(VI) increased with elapsed time after acidification in this study. The reduction rate varied with various cements. From our result, we can conclude that simultaneous additions of acid and DPC were required for the accurate measurement of Cr(VI) in cement. The high recovery rate of 94.3 to 106.7% with the simultaneous acid-DPC addition method can also support our conclusion.

  • PDF

Characterization of Microbial Fuel Cells Enriched Using Cr(VI)-Containing Sludge

  • Ryu, Eun-Yeon;Kim, Mi-A;Lee, Sang-Joon
    • Journal of Microbiology and Biotechnology
    • /
    • v.21 no.2
    • /
    • pp.187-191
    • /
    • 2011
  • Microbial fuel cells (MFCs) were successfully enriched using sludge contaminated with Cr(VI) and their characteristics were investigated. After enrichment, the charge of the final 10 peaks was 0.51 C ${\pm}$ 1.16%, and the anodic electrode was found to be covered with a biofilm. The enriched MFCs removed 93% of 5 mg/l Cr(VI) and 61% of 25 mg/l Cr(VI). 16S rDNA DGGE profiles from the anodic electrode indicated that ${\beta}$-Proteobacteria, Actinobacteria, and Acinetobacter sp. dominated. This study is the first to report that electrochemically active and Cr(VI)-reducing bacteria could be enriched in the anode compartment of MFCs using Cr(VI)-containing sludge and demonstrates the Cr(VI) removal capability of such MFCs.

Selective Removal of Cr (VI) and Cr (III) in Aqueous Solution by Surface Modified Activated Carbon

  • Lee, Jeong-Min;Kim, Min-Il;Lee, Young-Seak
    • Carbon letters
    • /
    • v.9 no.1
    • /
    • pp.23-27
    • /
    • 2008
  • The adsorption and reduction of Cr (VI) to Cr (III) by surface modified activated carbon (AC) in an aqueous solution was studied. The effects of surface modifications on the properties of the carbons were investigated by the analysis of specific surface area, carbon surface pH, acid/base surface values and functional groups. In order to understand the Cr(VI) adsorption and reduction ratio from Cr(VI) to Cr(III), the Cr adsorption capacity of AC was also measured and discussed by using inductively coupled plasma and UV spectrophotometer. The modifications bring about substantial variation in the chemical properties whereas the physical properties such as specific surface area, pore volume and pore size distribution nearly were not changed. Total Cr adsorption efficiency of as-received activated carbon (R-AC) and nitric acid treated activated carbon (N1-AC and N2-AC) were recorded on 98.2, 99.7 and 100%. Cr(III) reduction efficiency of R-AC increased largely from 0.4% to 28.3% compared to N1-AC and N2-AC.

Anodization of $TiO_2$ with Seawater Electrolyte; Evaluation of Hydrogen Production in PEG and Photocatalytic Cr(VI) Reduction (해수전해질을 이용한 양극산화 $TiO_2$ 제조; 광전기화학적 수소제조 및 Cr(VI) 환원처리 연구)

  • Shim, Eun-Jung;Park, Min-Sung;Her, A-Young;Joo, Hyun-Ku;Yoon, Jae-Kyung
    • Journal of Hydrogen and New Energy
    • /
    • v.20 no.5
    • /
    • pp.404-409
    • /
    • 2009
  • The present works were performed that titanium foil was anodized in various dilution ratios of seawater and distilled water with 10V external voltage applied, then annealed at $450^{\circ}C$ to obtain $TiO_2$ on the Ti substrate. The prepared samples were characterized by instruments (XRD, SEM, and photocurrent) and used to investigate rate of hydrogen production in photoelectrochemical cell as well as Cr(VI) reduction. As the results of experiments, the anodized $TiO_2$ in seawater electrolytes, which are ranged from 15 to 50 times dilution of seawater, was showed a relatively higher hydrogen production (ca. 97~110 umol/hr-$cm^2$) and Cr(VI) reduction (ca. 95% reduction).

Cloning of hexavalent chromium reductase gene from E.coli ATCC 33456

  • Lee, Han-Ki;Ahn, Min-Jung;Bae, Woo-Chul;Jeong, Byeong-Chul
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.672-675
    • /
    • 2000
  • E.coli ATCC 33456 has relatively higher activity of Cr(VI) reduction than other microorganism. The purpose of this research is cloning of Cr(V) reductase from E.coli ATCC 33456. Using colony and southern hybridization, we selected two condidates. Among candidates, pNCR9 is higher Cr(VI) reduction activity than E.coli ATCC 33456. Purified Cr(VI) reductase antibody was reacted at estimated 42Kda protein band of candidate's crude extract on 12% SDS-PAGE. This results showed cloned gene's product is very similar to purified Cr(VI) reductase from E.coli ATCC 33456.

  • PDF

Adsorption Characteristics of Cr(VI) on the Oak Sawdust (참나무톱밥에 대한 6가크롬의 흡착특성)

  • Chung, Yongsoon;Lee, Kangwoo;Hwang, Jongyeon
    • Analytical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.254-259
    • /
    • 1998
  • The adsorption and reduction characteristics of chromium(VI) by oak sawdust were studied. The optimum adsorption condition is obtained from the measurement of the distribution coefficient($K_d$) and adsorption capacity of Cr(VI) on the sawdust by changing pH of the solution. As a result, it was found that pH 2.0 was optimum because $K_d$ of Cr(VI) was maximum and reducing quantity was minimum. By the use of these characteristics of the oak sawdust, the removing of Cr(VI) in industrial waste water was examined.

  • PDF