• Title/Summary/Keyword: Covering Thickness

Search Result 142, Processing Time 0.03 seconds

Study on the Sewability of Special Fabrics (특수직물의 봉제에 관한 연구)

  • 장지혜
    • Journal of the Korean Home Economics Association
    • /
    • v.11 no.1
    • /
    • pp.26-43
    • /
    • 1973
  • This study was carried out on the Sewbility of Urethane Foam usually used as coldproof lining. The Sewability was estimated with the Puckering Grade and Seam Efficiency according to the thicknes of urethane foam, fineness and material of sewing thread, and the sort of covering fabric. The result shows the following ; 1. The thick foam proportinally shows the low Puckering Grade. 2. Effect on the sewability is small in fineness of sewing thread but large in material. Especially silk thread shows the greatest sewability in foam sewing. When the material of covering fabric is same as that of sewing thread (for example ; p/c fabric and p/c thread) the sewability is excellent in special. 3. Taffeta in covering foam is not suitable to foam sewing, satin and twill show superior sewability without reagrd to the thickness of foam. 4. In case of sewing foam covered with tricot, optimum thickness of foam and fineness of sewing thread through pretest must determine. 5. The thicker foam is the better seam efficiency tends, and Seam Efficiency largely effects to the strength of the sewing thread itself. 6. The seam Efficiency can heighten with the strength of sewing thread in proportion to that of covering fabric.

  • PDF

Transfer of Arsenic from Soilsto Rice Grains through Reducing the Thickness of Soil Covering in Soil Reclamation in an Abandoned Coal Mine Area (폐석탄광산 농경지(논) 토양개량복원 시 복토두께 조정에 따른 비소의 벼 전이효과 현장실증)

  • Il-Ha Koh;Yo Seb Kwon;Ju In Ko;Won Hyun Ji
    • Journal of Environmental Impact Assessment
    • /
    • v.32 no.3
    • /
    • pp.157-165
    • /
    • 2023
  • In Korea, a major contaminant of farmland soils in the vicinity of abandoned mines is arsenic, for which the general soil reclamation method is contaminated soil stabilization and cover the stabilized soil with clean soil at a thickness of 40 cm. In a previous pot experiment study we confirmed the feasibility of a lower thickness (20 cm) of covering soil for such reclamation in abandoned coal mines, where arsenic contamination levels are generally lower than in metal mines. In this subsequent study a field experiment including rice plant cultivation in field test plots was conducted. For over 4 months, the transfer of arsenic from the contaminated soil to the unpolished rice grains was reduced by 44% when a clean soil covering with a thickness of 20 cm was applied. The maximum decrease (56%) was shown when the stabilization process was performed before the covering. These results reveal a lower thickness of clean soil covering has a high feasibility and it can increase cost-efficiency in the reclamation of an abandoned coal mine.

An Experimental Study on the Fireproof Covering Thickness of High Strength Concrete Members with Spray Coating (뿜칠피복재를 사용한 고강도 콘크리트 부재의 내화피복두께에 관한 실험적 연구)

  • Lee, Tae-Gyu
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.41-46
    • /
    • 2010
  • High strength concrete (HSC) has been mainly used in large SOC structures. HSC have superior property as well as improvement in durability compared with normal strength concrete. In spite of durability of HSC, explosive spalling in concrete front surface near the source of fire occurs serious problem in structural safety. Therefore, this study is concerned with experimentally investigation of fire resistance at high temperature due to fireproof material covering thickness in addition to concrete cover. From the test result, it was appeared that the use of fireproof material results in good performance for fire resistance and spalling prevention, and the optimal fireproof covering thickness is 1~3mm. On the other hand, the temperature was rapidly increased by explosive spalling within 30 minutes and showed very little rise caused by evaporation heat after then. It was also found that the void channel was remained at high temperature as PP fiber melts at about $200^{\circ}C$, and the pore pressure in concrete was decreased.

A Study on Fire Resistance Performance Evaluation for Field Application of Ultra-High Strength Concrete (초고강도 내화 콘크리트의 현장 적용을 위한 내화성능 평가에 관한 연구)

  • Baek, Young-Woon;Yuk, Tae-Won;Park, Dong-Soo;Kim, Han-Sol;Lee, Hang-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.41-42
    • /
    • 2023
  • The physical performance of high-strength concrete deteriorates when exposed to high temperatures such as fire. In particular, in the case of ultra-high-strength concrete, there is a high possibility of explosion due to internal water pressure and thermal expansion due to the tight internal structure. In this paper, a fire resistance certification test was conducted for field application of ultra-high-strength fire-resistant concrete, and the fire resistance performance (temperature rise of main rebar) was compared according to the structural concrete cover thickness. As a result, when the covering thickness was 40 mm, three structures did not meet the certification standards, and when the covering thickness was 50 mm, all structures met the fire resistance certification standards.

  • PDF

Spatting Resistance of High Strength RC Column Covering Spray-on Materials of Fiber Composite Spray Mortar(FCSM) (섬유복합모르터의 뿜칠마감에 의한 고강도콘크리트 기둥부재의 폭렬방지)

  • Song Yong-Won;Han Dong-Yeob;Lee Gun-Cheol;Goh Kyoung-Taek;Kim Jin-Soo;Han Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.05a
    • /
    • pp.5-8
    • /
    • 2006
  • High strength concrete has been increasingly used in high rue building and it is very obvious re consider fire resistance performance of that. Unlike the normal strength concrete, high strength concrete in sudden elevating temperature at fire is susceptible to spalling with severe explosion and surface split, due to high density of concrete. In order to endure the spalling, inner space temperature of concrete should be control less than certain point. Therefore this study investigated the influence of covering materials on high strength concrete finishing spray-on materials of fiber composite spray mortar(FCSM). Both polypropylene(PP) and polyvinyl alcohol(PVA) fiber were used in this test. Test showed that concrete, covering 18mm mortar containing PVA fiber and confining metal lath 2.3mm thickness, decreased 50% of main bar ambient temperature. compared with control concrete. In addition, concrete covering 18mm mortar without fiber caused falling of covering materials and then it was exposed in elevating temperature. As a result, spatting of the concrete occurred same as control concrete. However, concrete covering spray-on mortar containing PVA or PP fiber resisted spatting occurrence.

  • PDF

Influence of thickness and incisal extension of indirect veneers on the biomechanical behavior of maxillary canine teeth

  • Costa, Victoria Luswarghi Souza;Tribst, Joao Paulo Mendes;Uemura, Eduardo Shigueyuki;de Morais, Dayana Campanelli;Borges, Alexandre Luiz Souto
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.4
    • /
    • pp.48.1-48.13
    • /
    • 2018
  • Objectives: To analyze the influence of thickness and incisal extension of indirect veneers on the stress and strain generated in maxillary canine teeth. Materials and Methods: A 3-dimensional maxillary canine model was validated with an in vitro strain gauge and exported to computer-assisted engineering software. Materials were considered homogeneous, isotropic, and elastic. Each canine tooth was then subjected to a 0.3 and 0.8 mm reduction on the facial surface, in preparations with and without incisal covering, and restored with a lithium disilicate veneer. A 50 N load was applied at $45^{\circ}$ to the long axis of the tooth, on the incisal third of the palatal surface of the crown. Results: The results showed a mean of $218.16{\mu}strain$ of stress in the in vitro experiment, and $210.63{\mu}strain$ in finite element analysis (FEA). The stress concentration on prepared teeth was higher at the palatal root surface, with a mean value of 11.02 MPa and varying less than 3% between the preparation designs. The veneers concentrated higher stresses at the incisal third of the facial surface, with a mean of 3.88 MPa and a 40% increase in less-thick veneers. The incisal cover generated a new stress concentration area, with values over 48.18 MPa. Conclusions: The mathematical model for a maxillary canine tooth was validated using FEA. The thickness (0.3 or 0.8 mm) and the incisal covering showed no difference for the tooth structure. However, the incisal covering was harmful for the veneer, of which the greatest thickness was beneficial.

Effects of different covering material on stable winter survival management with edible leaf in ramie (Boehmeria nivea L.).

  • Kim, Myeong Seok;An, Ho Sub;Kim, Gil Ja;Kim, Yong Soon;Choi, Jin Gyung;Kim, Dong Kwan;Park, Heung Gyu;Kim, Hyun Woo;Kim, Seong Il
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.226-226
    • /
    • 2017
  • This study was to evaluate methods to high quality food ramie rice cake, thereby increasing farm income. This study investigated the effects of different covering material on stable winter survival management with edible leaf in Ramie(Boehmeria nivea L.). The method of winter survival with covering material were conducted under three condition compose to Non covering, Rice straw cutting covered with 500kg.10a-1, Rice husks covered with 1,000kg.10a-1(covered 4~5 cm thickness in the soil surface). Method of application were standard application(N-P-K-Compost applied at 27-9-27-600kg.10a-1. Compost and fused phosphate applied at 100% of basal fertilizer in March 25. 20% of top dressing were four times application in March 25 - October 5. Planting year were March 15, 2011. Plants were spaced 60 cm apart in rows 25 cm apart with open cultivation. According to non covering < Rice husks covered with 1,000kg.10a-1 < Rice straw cutting covered with 500kg.10a-1 cultivation this order, aerial part as a result were plenty amount of growth. Sprout time and winter survival rates was uncovering control plot compared to 2 - 5 days quickly, 45-57% highly by rice husks and rice straw covering. Green leaf yields is untreated control plot (12,44 kg.10a-1) compared to rice husks covering 7% higher, and rice straw covering increased to 18% of the most.

  • PDF

The Experimental Study of Inorganic Performanent내s of Fire Resistance Evaluation (무기질계 영구거푸집의 내화성능에 관한 실험적 연구)

  • 김영진;백민수;정근호;김우재;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.495-500
    • /
    • 2002
  • The purpose of this study is to develop and to apply this permanent cement mortar form as one of those system forms to improve existing form's problems. (1) In the fire proof test with combined specimen, the fire proof covering including form section thickness is satisfied with the fire proof criterion. It is considered that form section thickness has no problem (2) The suitable method of normal pressure steam curing for the form's mass production is 4 hours in 65℃ considering production cost, the silica fume admixture is economic.

  • PDF

A Photochromic Dye Activation Method for Measuring the Thickness of Liquid Films

  • Kim, Jeong-Bae;Kim, Moo-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.6
    • /
    • pp.966-970
    • /
    • 2005
  • To measure the thickness of liquid films from 10 to 60 ${\mu}m$, we used photochromic dye activation. And we used silicone oil with 10 centi-Stokes and commercial photochromic dyes. To make films with exact and known thicknesses, we used two glass wafers. A film formed between two wafers after placing a drop of liquid of known volume on one wafer and covering the other. The film thickness could be estimated from the diameter of wafer and the dropped liquid volume. To quantitatively evaluate the result, captured the images using digital camera then analyzed the images using the image tool. The gray scale intensity using the captured images of activated dye with these thicknesses showed the repeatability below ${\pm}$ 1.0% when measured with a silicone oil solution containing 0.1% SO and SO-ANTH dyes. And we showed that photochromic dye activation method could be used to measure our liquid film thickness ranges.

An Experimental Study on the Fire Resistance Performance of the Reinforced Concrete Columns According to the Cross Section Size and Depth of Concrete Cover (단면크기 및 피복두께 변화에 따른 철근콘크리트 기둥의 내화성능에 관한 실험적 연구)

  • Cho, Kyung-Suk;Yeo, In-Hwan;Cho, Bum-Yeon;Kim, Heung-Youl;Min, Byung-Yeol
    • Fire Science and Engineering
    • /
    • v.25 no.1
    • /
    • pp.78-84
    • /
    • 2011
  • Recent researches of the fire resistance in concrete focus on how to secure relevant functions in the high strength concrete. However, the demand of normal strength concrete less than 40 MPa takes most of the total concrete demand. Therefore, fire resistance study needs to cover not only high strength concretes but also normal strength concretes. This study evaluated the fire resistance performance of 40 MPa concrete columns, taking the concrete covering thickness and the size of section as variables. Consequently, the fire resistance performance improved as the section size and the covering thickness became larger.